The feasibility of contrast-enhanced spectral mammography immediately after contrast-enhanced CT

Authors: Nobuko Okada, Fuminari Tatsugami, Mai Sugai, Izumi Okita, Mitsuya Ito, Shoichiro Ohtani, Kouichi Ichimura, Masaki Urashima, Kazuo Awai

Published in: Radiological Physics and Technology | Issue 3/2019

Login to get access

Abstract

Contrast-enhanced spectral mammography (CESM) is a digital mammography method that requires an intravenous injection of iodinated contrast material to detect hypervascular lesions. In patients undergoing evaluation for metastases before breast tumor surgery, a contrast material must be injected for computed tomography (CT) and CESM studies. The purpose of our study was to investigate the feasibility of performing CESM immediately after contrast-enhanced CT, without injecting additional contrast material. We enrolled 77 women with 88 breast carcinomas. Immediately after contrast-enhanced CT, we performed CESM without injecting additional contrast material. The patients were divided into two groups based on the length of the interval between contrast material injection and the start of mammography. In group A (n = 51), it was less, and in group B (n = 26) it was more than 7 min. We measured the tumor gland contrast of each tumor on the CESM images and recorded the tumor opacification on a 4-point visual scale. The mean interval between the start of contrast material injection for CT and the acquisition of mammograms in groups A and B was 5.41 and 10.40 min, respectively. All lesions were detectable on the CESM images. There was no significant difference in the visual evaluation between the two groups (p = 0.21). CESM immediately after contrast-enhanced CT without the injection of additional contrast material is feasible and cost-effective.
Literature
7.
go back to reference Luczynska E, Niemiec J, Hendrick E, Heinze S, Jaszczynski J, Jakubowicz J, et al. Degree of enhancement on contrast enhanced spectral mammography (CESM) and lesion type on mammography (MG): comparison based on histological results. Med Sci Monit Int Med J Exp Clin Res. 2016;22:3886–933. Luczynska E, Niemiec J, Hendrick E, Heinze S, Jaszczynski J, Jakubowicz J, et al. Degree of enhancement on contrast enhanced spectral mammography (CESM) and lesion type on mammography (MG): comparison based on histological results. Med Sci Monit Int Med J Exp Clin Res. 2016;22:3886–933.
14.
go back to reference Shiraishi A, Kurosaki Y, Maehara T, Suzuki M, Kurosumi M. Extension of ductal carcinoma in situ: histopathological association with MR imaging and mammography. Magn Reson Med Sci. 2003;2(4):159–63.CrossRefPubMed Shiraishi A, Kurosaki Y, Maehara T, Suzuki M, Kurosumi M. Extension of ductal carcinoma in situ: histopathological association with MR imaging and mammography. Magn Reson Med Sci. 2003;2(4):159–63.CrossRefPubMed
Metadata
Title
The feasibility of contrast-enhanced spectral mammography immediately after contrast-enhanced CT
Authors
Nobuko Okada
Fuminari Tatsugami
Mai Sugai
Izumi Okita
Mitsuya Ito
Shoichiro Ohtani
Kouichi Ichimura
Masaki Urashima
Kazuo Awai
Publication date
01-09-2019
Publisher
Springer Singapore
Published in
Radiological Physics and Technology / Issue 3/2019
Print ISSN: 1865-0333
Electronic ISSN: 1865-0341
DOI
https://doi.org/10.1007/s12194-019-00518-6

Other articles of this Issue 3/2019

Radiological Physics and Technology 3/2019 Go to the issue