Abstract

The aim of the study is to present the diagnostic feasibility, usefulness, and safety of a novel technique for coaxial CT-guided fine-needle aspiration biopsy of small (≤20 mm in diameter) lung nodules. A 18-gauge (G) (1.2 × 40 mm) needle is inserted through the skin in the depth of the thoracic wall tissues remaining outside the pleura. Its positioning is planned and adjusted using multiplanar reconstruction (MPR) images along the 18-G guide needle axis tracing a reference outline extended from the needle tip to the target nodule. When the insertion of the 18-G extra-pleuric needle (EPN) proves to be precise, a 22-G Chiba needle is then passed through the outer 18-G EPN until it reaches the thoracic lesion for the sampling procedure. Patient population included 153 males and 94 females, with a mean age of 61.3 ± 21.6 years. Mean nodule diameter was 14.1 ± 2.2 mm. The lesion depth from pleural plane ranged from 0 mm to 127 mm. An average of 1.29 aspirates were performed per lesion. The most common complication was pneumothorax in 27 cases; there were no cases of PNX requiring chest tube insertion. Intrapulmonary bleeding along the needle track was observed in 32 patients. Exploiting the advantage of MPR images, our novel technique of extra-pleuric coaxial system with a 18-G EPN allows the operator to multiple samplings of small (≤20 mm) target lesions in various locations with a thinner (22-G Chiba) needle, thus reducing the degree of pleural, parenchymal, or adjacent organs damage.
Literature
1.
go back to reference Otto S, Mensel B, Friedrich N, Schäfer S, Mahlke C, von Bernstorff W, et al. Predictors of technical success and rate of complications of image-guided percutaneous transthoracic lung needle biopsy of pulmonary tumors. PLoS ONE. 2015;10:e0124947.CrossRefPubMedPubMedCentral Otto S, Mensel B, Friedrich N, Schäfer S, Mahlke C, von Bernstorff W, et al. Predictors of technical success and rate of complications of image-guided percutaneous transthoracic lung needle biopsy of pulmonary tumors. PLoS ONE. 2015;10:e0124947.CrossRefPubMedPubMedCentral
2.
go back to reference Rui H, Nan-Chuan J, Hao-Hao L, Yu-Hui W, Li H, He-Shui S, et al. Precision of coaxial needle placement in computed tomography-guided transthoracic needle biopsy. Exp Ther Med. 2013;6:1307–11. Rui H, Nan-Chuan J, Hao-Hao L, Yu-Hui W, Li H, He-Shui S, et al. Precision of coaxial needle placement in computed tomography-guided transthoracic needle biopsy. Exp Ther Med. 2013;6:1307–11.
3.
go back to reference Ierardi AM, Mangini M, Fontana F, Floridi C, De Marchi G, Petrillo M, et al. Usefulness and safety of biliary percutaneous transluminal forceps biopsy (PTFB): our experience. Minim Invasive Ther Allied Technol. 2014;23:96–101.CrossRefPubMed Ierardi AM, Mangini M, Fontana F, Floridi C, De Marchi G, Petrillo M, et al. Usefulness and safety of biliary percutaneous transluminal forceps biopsy (PTFB): our experience. Minim Invasive Ther Allied Technol. 2014;23:96–101.CrossRefPubMed
4.
go back to reference Sa YJ, Kim JJ, Du Kim Y, Sim SB, Moon SW. A new protocol for concomitant needle aspiration biopsy and localization of solitary pulmonary nodules. J Cardiothorac Surg. 2015;10:104.CrossRefPubMedPubMedCentral Sa YJ, Kim JJ, Du Kim Y, Sim SB, Moon SW. A new protocol for concomitant needle aspiration biopsy and localization of solitary pulmonary nodules. J Cardiothorac Surg. 2015;10:104.CrossRefPubMedPubMedCentral
5.
go back to reference Schulze R, Seebacher G, Enderes B, Kugler G, Fischer JR, Graeter TP. Complications in CT-guided, semi-automatic coaxial core biopsy of potentially malignant pulmonary lesions. RöFo Fortschr auf dem Geb der Röntgenstr und der Nukl. 2015;187:697–702.CrossRef Schulze R, Seebacher G, Enderes B, Kugler G, Fischer JR, Graeter TP. Complications in CT-guided, semi-automatic coaxial core biopsy of potentially malignant pulmonary lesions. RöFo Fortschr auf dem Geb der Röntgenstr und der Nukl. 2015;187:697–702.CrossRef
6.
go back to reference Yaffe D, Koslow M, Haskiya H, Shitrit D. A novel technique for CT-guided transthoracic biopsy of lung lesions: improved biopsy accuracy and safety. Eur Radiol. 2015;25(11):3354–60.CrossRefPubMed Yaffe D, Koslow M, Haskiya H, Shitrit D. A novel technique for CT-guided transthoracic biopsy of lung lesions: improved biopsy accuracy and safety. Eur Radiol. 2015;25(11):3354–60.CrossRefPubMed
7.
go back to reference De Filippo M, Onniboni M, Rusca M, Carbognani P, Ferrari L, Guazzi A, et al. Advantages of multidetector-row CT with multiplanar reformation in guiding percutaneous lung biopsies. Radiol Med. 2008;113:945–53.CrossRefPubMed De Filippo M, Onniboni M, Rusca M, Carbognani P, Ferrari L, Guazzi A, et al. Advantages of multidetector-row CT with multiplanar reformation in guiding percutaneous lung biopsies. Radiol Med. 2008;113:945–53.CrossRefPubMed
8.
go back to reference Li Y, Du Y, Yang HF, Yu JH, Xu XX. CT-guided percutaneous core needle biopsy for small (≤20 mm) pulmonary lesions. Clin Radiol. 2013;68:e43–8.CrossRefPubMed Li Y, Du Y, Yang HF, Yu JH, Xu XX. CT-guided percutaneous core needle biopsy for small (≤20 mm) pulmonary lesions. Clin Radiol. 2013;68:e43–8.CrossRefPubMed
9.
go back to reference Rotolo N, Floridi C, Imperatori A, Fontana F, Ierardi AM, Mangini M, et al. Comparison of cone-beam CT-guided and CT fluoroscopy-guided transthoracic needle biopsy of lung nodules. Eur Radiol. 2016;26:381–9.CrossRefPubMed Rotolo N, Floridi C, Imperatori A, Fontana F, Ierardi AM, Mangini M, et al. Comparison of cone-beam CT-guided and CT fluoroscopy-guided transthoracic needle biopsy of lung nodules. Eur Radiol. 2016;26:381–9.CrossRefPubMed
10.
go back to reference De Filippo M, Saba L, Rossi E, Nizzoli R, Tiseo M, Pedrazzi G, et al. Curved needles in CT-guided fine needle biopsies of abdominal and retroperitoneal small lesions. Cardiovasc Intervent Radiol. 2015;38:1611–6.CrossRefPubMed De Filippo M, Saba L, Rossi E, Nizzoli R, Tiseo M, Pedrazzi G, et al. Curved needles in CT-guided fine needle biopsies of abdominal and retroperitoneal small lesions. Cardiovasc Intervent Radiol. 2015;38:1611–6.CrossRefPubMed
11.
go back to reference De FilippoM, Saba L, Silva M, Zagaria R, Concari G, Nizzoli R, et al. CT-guided biopsy of pulmonary nodules: is pulmonary hemorrhage a complication or an advantage? Diagn Interv Radiol. 2014;20:421–5.CrossRef De FilippoM, Saba L, Silva M, Zagaria R, Concari G, Nizzoli R, et al. CT-guided biopsy of pulmonary nodules: is pulmonary hemorrhage a complication or an advantage? Diagn Interv Radiol. 2014;20:421–5.CrossRef
12.
go back to reference De Filippo M, Saba L, Azzali E, Milanese G, Mostardi M, Borgia D, et al. CT-guided fine-needle aspiration of abdominal and retroperitoneal small lesions with the coaxial technique using MPR images. Acta Biomed. 2016;87(Suppl 3):57–62.PubMed De Filippo M, Saba L, Azzali E, Milanese G, Mostardi M, Borgia D, et al. CT-guided fine-needle aspiration of abdominal and retroperitoneal small lesions with the coaxial technique using MPR images. Acta Biomed. 2016;87(Suppl 3):57–62.PubMed
13.
go back to reference Reginelli A, Rossi C, Capasso R, Urraro F, Cagini L, Di Crescenzo V, et al. Evaluation with multislice CT of the hilar pulmonary nodules for probable infiltration of vascular-bronchial structures. Recenti Prog Med. 2013;104:403–5.PubMed Reginelli A, Rossi C, Capasso R, Urraro F, Cagini L, Di Crescenzo V, et al. Evaluation with multislice CT of the hilar pulmonary nodules for probable infiltration of vascular-bronchial structures. Recenti Prog Med. 2013;104:403–5.PubMed
14.
go back to reference De Filippo M, Saba L, Concari G, Nizzoli R, Ferrari L, Tiseo M, et al. Predictive factors of diagnostic accuracy of CT-guided transthoracic fine-needle aspiration for solid noncalcified, subsolid and mixed pulmonary nodules. Radiol Med. 2013;118:1071–81.CrossRefPubMed De Filippo M, Saba L, Concari G, Nizzoli R, Ferrari L, Tiseo M, et al. Predictive factors of diagnostic accuracy of CT-guided transthoracic fine-needle aspiration for solid noncalcified, subsolid and mixed pulmonary nodules. Radiol Med. 2013;118:1071–81.CrossRefPubMed
15.
go back to reference Guimaraes M, Marchiori E, Hochhegger B, Chojniak R, Gross J. CT-guided biopsy of lung lesions: defining the best needle option for a specific diagnosis. Clinics. 2014;69:335–40.CrossRefPubMedPubMedCentral Guimaraes M, Marchiori E, Hochhegger B, Chojniak R, Gross J. CT-guided biopsy of lung lesions: defining the best needle option for a specific diagnosis. Clinics. 2014;69:335–40.CrossRefPubMedPubMedCentral
16.
go back to reference Nour-Eldin N-EA, Alsubhi M, Emam A, Lehnert T, Beeres M, Jacobi V, et al. Pneumothorax complicating coaxial and non-coaxial CT-guided lung biopsy: comparative analysis of determining risk factors and management of pneumothorax in a retrospective review of 650 patients. Cardiovasc Intervent Radiol. 2016;39(2):261–70.CrossRefPubMed Nour-Eldin N-EA, Alsubhi M, Emam A, Lehnert T, Beeres M, Jacobi V, et al. Pneumothorax complicating coaxial and non-coaxial CT-guided lung biopsy: comparative analysis of determining risk factors and management of pneumothorax in a retrospective review of 650 patients. Cardiovasc Intervent Radiol. 2016;39(2):261–70.CrossRefPubMed
17.
go back to reference Geraghty PR, Kee ST, McFarlane G, Razavi MK, Sze DY, Dake MD. CT-guided transthoracic needle aspiration biopsy of pulmonary nodules: needle size and pneumothorax rate. Radiology. 2003;229:475–81.CrossRefPubMed Geraghty PR, Kee ST, McFarlane G, Razavi MK, Sze DY, Dake MD. CT-guided transthoracic needle aspiration biopsy of pulmonary nodules: needle size and pneumothorax rate. Radiology. 2003;229:475–81.CrossRefPubMed
18.
go back to reference Carrafiello G, Mangini M, Fontana F, Di Massa A, Ierardi AM, Cotta E, et al. Complications of microwave and radiofrequency lung ablation: personal experience and review of the literature. Radiol Med. 2012;117(2):201–13.CrossRefPubMed Carrafiello G, Mangini M, Fontana F, Di Massa A, Ierardi AM, Cotta E, et al. Complications of microwave and radiofrequency lung ablation: personal experience and review of the literature. Radiol Med. 2012;117(2):201–13.CrossRefPubMed
19.
go back to reference Kuban JD, Tam AL, Huang SY, Ensor JE, Philip AS, Chen GJ, et al. The effect of needle gauge on the risk of pneumothorax and chest tube placement after percutaneous computed tomographic (CT)-guided lung biopsy. Cardiovasc Intervent Radiol. 2015;38:1595–602.CrossRefPubMed Kuban JD, Tam AL, Huang SY, Ensor JE, Philip AS, Chen GJ, et al. The effect of needle gauge on the risk of pneumothorax and chest tube placement after percutaneous computed tomographic (CT)-guided lung biopsy. Cardiovasc Intervent Radiol. 2015;38:1595–602.CrossRefPubMed
20.
go back to reference Priola AM, Priola SM, Cataldi A, Di Franco M, Pazè F, Marci V, et al. Diagnostic accuracy and complication rate of CT-guided fine needle aspiration biopsy of lung lesions: a study based on the experience of the cytopathologist. Acta Radiol. 2010;51:527–33.CrossRefPubMed Priola AM, Priola SM, Cataldi A, Di Franco M, Pazè F, Marci V, et al. Diagnostic accuracy and complication rate of CT-guided fine needle aspiration biopsy of lung lesions: a study based on the experience of the cytopathologist. Acta Radiol. 2010;51:527–33.CrossRefPubMed
21.
go back to reference Ko JP, Shepard JO, Drucker EA, Aquino SL, Sharma A, Sabloff B, et al. Factors influencing pneumothorax rate at lung biopsy: are dwell time and angle of pleural puncture contributing factors? Radiology. 2001;218:491–6.CrossRefPubMed Ko JP, Shepard JO, Drucker EA, Aquino SL, Sharma A, Sabloff B, et al. Factors influencing pneumothorax rate at lung biopsy: are dwell time and angle of pleural puncture contributing factors? Radiology. 2001;218:491–6.CrossRefPubMed
22.
go back to reference Yeow KM, Su IH, Pan KT, Tsay PK, Lui KW, Cheung YC, et al. Risk factors of pneumothorax and bleeding: Multivariate analysis of 660 CT-guided coaxial cutting needle lung biopsies. Chest. 2004;126:748–54.CrossRefPubMed Yeow KM, Su IH, Pan KT, Tsay PK, Lui KW, Cheung YC, et al. Risk factors of pneumothorax and bleeding: Multivariate analysis of 660 CT-guided coaxial cutting needle lung biopsies. Chest. 2004;126:748–54.CrossRefPubMed
Metadata
Title
Extra-pleuric coaxial system for CT-guided percutaneous fine-needle aspiration biopsy (FNAB) of small (≤20 mm) lung nodules: a novel technique using multiplanar reconstruction (MPR) images
Authors
Raffaella Capasso
Rita Nizzoli
Marcello Tiseo
Giuseppe Pedrazzi
Luca Brunese
Antonio Rotondo
Massimo De Filippo
Publication date
01-02-2017
Publisher
Springer US
Published in
Medical Oncology / Issue 2/2017
Print ISSN: 1357-0560
Electronic ISSN: 1559-131X
DOI
https://doi.org/10.1007/s12032-016-0871-4

Other articles of this Issue 2/2017

Medical Oncology 2/2017 Go to the issue