Abstract

Background

Acetabular component position is associated with joint function and bearing wear. Current techniques for determining acetabular component version on standard radiographs lack reliability. Other, more consistent techniques are time-consuming and require additional equipment or software.

Questions/purposes

We compared three methods of acetabular component position assessment: (1) Einzel-Bild-Roentgen-Analyse (EBRA), (2) Woo and Morrey, and (3) the new ischiolateral method.

Patients and Methods

We assessed axial component position for 52 hips, with at least three radiographic series, using EBRA, and on true lateral radiographs using the Woo and Morrey method and a new method that uses the ischium as a skeletal landmark, the ischiolateral method.

Results

The mean SDs of the ischiolateral (2.15°) and EBRA (2.06°) methods were lower than that of the Woo and Morrey method (3.65°) but were not different from one another. We observed a SD of greater than 4° in 19 (36.5%) hip series using the Woo and Morrey method, compared to six series (11.5%) for both the ischiolateral and EBRA methods. Twenty-four (12.6%) Woo and Morrey measurements were greater than 4° from the mean for the hip series, compared to seven (3.8%) for ischiolateral and nine (4.7%) for EBRA. The intraclass correlation coefficients for intra- and interobserver reliability for the ischiolateral method and EBRA were the same (0.9).

Conclusions

Referencing the ischium standardizes pelvic position on each lateral radiograph and provides a simple and reliable means to assess axial component position, which is a surrogate for the planar anteversion measured by EBRA.
Literature
1.
go back to reference Arai N, Nakamura S, Matsushita T. Difference between 2 measurement methods of version angles of the acetabular component. J Arthroplasty. 2007;22:715–720.PubMedCrossRef Arai N, Nakamura S, Matsushita T. Difference between 2 measurement methods of version angles of the acetabular component. J Arthroplasty. 2007;22:715–720.PubMedCrossRef
2.
go back to reference Barrack RL, Schmalzried TP. Impingement and rim wear associated with early osteolysis after a total hip replacement. J Bone Joint Surg Am. 2002;84:1218–1220.PubMed Barrack RL, Schmalzried TP. Impingement and rim wear associated with early osteolysis after a total hip replacement. J Bone Joint Surg Am. 2002;84:1218–1220.PubMed
3.
go back to reference Danelius G, Miller LF. Lateral view of the hip. AJR Am J Roentgenol. 1936;35:282–284. Danelius G, Miller LF. Lateral view of the hip. AJR Am J Roentgenol. 1936;35:282–284.
4.
go back to reference Hing CB, Back DL, Bailey M, Young DA, Dalziel RE, Shimmin AJ. The results of primary Birmingham hip resurfacings at a mean of five years: an independent prospective review of the first 230 hips. J Bone Joint Surg Br. 2007;89:1431–1438.PubMedCrossRef Hing CB, Back DL, Bailey M, Young DA, Dalziel RE, Shimmin AJ. The results of primary Birmingham hip resurfacings at a mean of five years: an independent prospective review of the first 230 hips. J Bone Joint Surg Br. 2007;89:1431–1438.PubMedCrossRef
5.
go back to reference Johnson CR. A new method for roentgenographic examination of the upper end of the femur. J Bone Joint Surg. 1932;14:859–866. Johnson CR. A new method for roentgenographic examination of the upper end of the femur. J Bone Joint Surg. 1932;14:859–866.
6.
go back to reference Laage H, Barnett JC, Brady JM, Dulligan PJ Jr, Fett HC, Gallagher TF, Schneider BA. Horizontal roentgenography of the hip in children. J Bone Joint Surg Am. 1953;35:387–398.PubMed Laage H, Barnett JC, Brady JM, Dulligan PJ Jr, Fett HC, Gallagher TF, Schneider BA. Horizontal roentgenography of the hip in children. J Bone Joint Surg Am. 1953;35:387–398.PubMed
7.
go back to reference Langton DJ, Jameson SS, Joyce TJ, Hallab NJ, Natu S, Nargol AV. Early failure of metal-on-metal bearings in hip resurfacing and large-diameter total hip replacement: a consequence of excess wear. J Bone Joint Surg Br. 2010;92:38–46.PubMedCrossRef Langton DJ, Jameson SS, Joyce TJ, Hallab NJ, Natu S, Nargol AV. Early failure of metal-on-metal bearings in hip resurfacing and large-diameter total hip replacement: a consequence of excess wear. J Bone Joint Surg Br. 2010;92:38–46.PubMedCrossRef
8.
go back to reference Langton DJ, Jameson SS, Joyce TJ, Webb J, Nargol AV. The effect of component size and orientation on the concentrations of metal ions after resurfacing arthroplasty of the hip. J Bone Joint Surg Br. 2008;90:1143–1151.PubMed Langton DJ, Jameson SS, Joyce TJ, Webb J, Nargol AV. The effect of component size and orientation on the concentrations of metal ions after resurfacing arthroplasty of the hip. J Bone Joint Surg Br. 2008;90:1143–1151.PubMed
9.
go back to reference Langton DJ, Joyce TJ, Jameson SS, Lord J, Van Orsouw M, Holland JP, Nargol AV, De Smet KA. Adverse reaction to metal debris following hip resurfacing: the influence of component type, orientation and volumetric wear. J Bone Joint Surg Br. 2011;93:164–171.PubMedCrossRef Langton DJ, Joyce TJ, Jameson SS, Lord J, Van Orsouw M, Holland JP, Nargol AV, De Smet KA. Adverse reaction to metal debris following hip resurfacing: the influence of component type, orientation and volumetric wear. J Bone Joint Surg Br. 2011;93:164–171.PubMedCrossRef
10.
go back to reference Langton DJ, Sprowson AP, Mahadeva D, Bhatnagar S, Holland JP, Nargol AV. Cup anteversion in hip resurfacing: validation of EBRA and the presentation of a simple clinical grading system. J Arthroplasty. 2010;25:607–613.PubMedCrossRef Langton DJ, Sprowson AP, Mahadeva D, Bhatnagar S, Holland JP, Nargol AV. Cup anteversion in hip resurfacing: validation of EBRA and the presentation of a simple clinical grading system. J Arthroplasty. 2010;25:607–613.PubMedCrossRef
11.
go back to reference Lewinnek GE, Lewis JL, Tarr R, Compere CL, Zimmerman JR. Dislocations after total hip-replacement arthroplasties. J Bone Joint Surg Am. 1978;60:217–220.PubMed Lewinnek GE, Lewis JL, Tarr R, Compere CL, Zimmerman JR. Dislocations after total hip-replacement arthroplasties. J Bone Joint Surg Am. 1978;60:217–220.PubMed
12.
go back to reference Massin P, Schmidt L, Engh CA. Evaluation of cementless acetabular component migration: an experimental study. J Arthroplasty. 1989;4:245–251.PubMedCrossRef Massin P, Schmidt L, Engh CA. Evaluation of cementless acetabular component migration: an experimental study. J Arthroplasty. 1989;4:245–251.PubMedCrossRef
13.
go back to reference McKee GK. Development of total prosthetic replacement of the hip. Clin Orthop Relat Res. 1970;72:85–103.PubMed McKee GK. Development of total prosthetic replacement of the hip. Clin Orthop Relat Res. 1970;72:85–103.PubMed
14.
go back to reference Murray DW. The definition and measurement of acetabular orientation. J Bone Joint Surg Br. 1993;75:228–232.PubMed Murray DW. The definition and measurement of acetabular orientation. J Bone Joint Surg Br. 1993;75:228–232.PubMed
15.
go back to reference Pollard JA, Daum WJ, Uchida T. Can simple radiographs be predictive of total hip dislocation? J Arthroplasty. 1995;10:800–804.PubMedCrossRef Pollard JA, Daum WJ, Uchida T. Can simple radiographs be predictive of total hip dislocation? J Arthroplasty. 1995;10:800–804.PubMedCrossRef
16.
go back to reference Pulos N, Tiberi JV 3rd, Schmalzried TP. Measuring acetabular component position on lateral radiographs: ischio-lateral method. Bull NYU Hosp Jt Dis. 2011;69(Suppl 1):S84–S89.PubMed Pulos N, Tiberi JV 3rd, Schmalzried TP. Measuring acetabular component position on lateral radiographs: ischio-lateral method. Bull NYU Hosp Jt Dis. 2011;69(Suppl 1):S84–S89.PubMed
17.
go back to reference Shrout PE, Fleiss JL. Intraclass correlations: uses in assessing rater reliability. Psychol Bull. 1979;86:420–428.PubMedCrossRef Shrout PE, Fleiss JL. Intraclass correlations: uses in assessing rater reliability. Psychol Bull. 1979;86:420–428.PubMedCrossRef
18.
go back to reference Walter WL, O’toole GC, Walter WK, Ellis A, Zicat BA. Squeaking in ceramic-on-ceramic hips: the importance of acetabular component orientation. J Arthroplasty. 2007;22:496–503.PubMedCrossRef Walter WL, O’toole GC, Walter WK, Ellis A, Zicat BA. Squeaking in ceramic-on-ceramic hips: the importance of acetabular component orientation. J Arthroplasty. 2007;22:496–503.PubMedCrossRef
19.
go back to reference Wan Z, Boutary M, Dorr LD. The influence of acetabular component position on wear in total hip arthroplasty. J Arthroplasty. 2008;23:51–56.PubMedCrossRef Wan Z, Boutary M, Dorr LD. The influence of acetabular component position on wear in total hip arthroplasty. J Arthroplasty. 2008;23:51–56.PubMedCrossRef
20.
go back to reference Woo RY, Morrey BF. Dislocations after total hip arthroplasty. J Bone Joint Surg Am. 1982;64:1295–1306.PubMed Woo RY, Morrey BF. Dislocations after total hip arthroplasty. J Bone Joint Surg Am. 1982;64:1295–1306.PubMed
Metadata
Title
A More Reliable Method to Assess Acetabular Component Position
Authors
John V. Tiberi, MD
Nicholas Pulos, MD
Michael Kertzner, BS
Thomas P. Schmlazried, MD
Publication date
01-02-2012
Publisher
Springer-Verlag
Published in
Clinical Orthopaedics and Related Research® / Issue 2/2012
Print ISSN: 0009-921X
Electronic ISSN: 1528-1132
DOI
https://doi.org/10.1007/s11999-011-2006-8

Other articles of this Issue 2/2012

Clinical Orthopaedics and Related Research® 2/2012 Go to the issue

Symposium: Papers Presented at the Annual Meetings of The Hip Society

Papers Presented at the Annual Meetings of the Hip Society 2011: Editorial Comment