Skip to main content
Top
Published in: International Orthopaedics 5/2004

01-10-2004 | Original Paper

Prosthetic alignment and sizing in computer-assisted total knee arthroplasty

Authors: Tomoyuki Matsumoto, Nobuhiro Tsumura, Masahiro Kurosaka, Hirotsugu Muratsu, Ryosuke Kuroda, Katsuhiko Ishimoto, Kazuo Tsujimoto, Ryoichi Shiba, Shinichi Yoshiya

Published in: International Orthopaedics | Issue 5/2004

Login to get access

Abstract

We implanted 60 posterior stabilized total knee prostheses (P.F.C. Sigma, DePuy, Warsaw, USA). In 30 cases, we used a CT-free navigation system (Vector Vision, Brain LAB, Heimstetten, Germany), and in 30 matched-paired controls, we used a conventional manual implantation. We compared postoperative long-leg radiographs in the two groups. The results revealed a significant difference in favor of navigation. In addition, we compared the preoperative anteroposterior dimension of the femoral condyle with the postoperative value. While there were no significant differences in the preoperative anteroposterior dimension of the femoral condyle between the two groups, the postoperative value in the navigation group was significantly larger than that of the preoperative value. Therefore, surgeons using navigation systems should guard against the possibility of oversizing when determining the size of the femoral component.
Literature
1.
go back to reference Daluga D, Lombardi AV, Mallory TH et al (1991) Knee manipulation following total knee arthroplasty. Analysis of prognostic variables. J Arthroplasty 6:119–128PubMed Daluga D, Lombardi AV, Mallory TH et al (1991) Knee manipulation following total knee arthroplasty. Analysis of prognostic variables. J Arthroplasty 6:119–128PubMed
2.
go back to reference Delp SL, Stulberg SD, Davies B et al (1998) Computer assisted knee replacement. Clin Orthop 354:49–56CrossRefPubMed Delp SL, Stulberg SD, Davies B et al (1998) Computer assisted knee replacement. Clin Orthop 354:49–56CrossRefPubMed
3.
go back to reference Hart R, Jaenecek M, Chaker A et al (2003) Total knee arthroplasty implanted with and without kinematic navigation. Int Orthop 27:366–369CrossRefPubMed Hart R, Jaenecek M, Chaker A et al (2003) Total knee arthroplasty implanted with and without kinematic navigation. Int Orthop 27:366–369CrossRefPubMed
4.
go back to reference Insall JN, Dorr LD, Scott RD et al (1989) Rationale of the Knee Society clinical rating system. Clin Orthop 248:13–14PubMed Insall JN, Dorr LD, Scott RD et al (1989) Rationale of the Knee Society clinical rating system. Clin Orthop 248:13–14PubMed
5.
go back to reference Jeffery RS, Morris RW, Denham RA (1991) Coronal alignment after total knee replacement. J Bone Joint Surg Br 73:709–714PubMed Jeffery RS, Morris RW, Denham RA (1991) Coronal alignment after total knee replacement. J Bone Joint Surg Br 73:709–714PubMed
6.
go back to reference Jenny JY, Boeri C (2001) Computer-assisted implantation of a total knee arthroplasty: a case-controlled study in comparison with classical instrumentation. Rev Chir Orthop Reparatrice Appar Mot 87:645–652PubMed Jenny JY, Boeri C (2001) Computer-assisted implantation of a total knee arthroplasty: a case-controlled study in comparison with classical instrumentation. Rev Chir Orthop Reparatrice Appar Mot 87:645–652PubMed
7.
go back to reference Mielke RK, Clemens U, Jens JH et al (2001) Navigation in knee endoprosthesis implantation-preliminary clinical experiences and prospective comparative study with conventional implantation technique. Z Orthop Ihre Grenzgeb 139:109–116CrossRefPubMed Mielke RK, Clemens U, Jens JH et al (2001) Navigation in knee endoprosthesis implantation-preliminary clinical experiences and prospective comparative study with conventional implantation technique. Z Orthop Ihre Grenzgeb 139:109–116CrossRefPubMed
8.
go back to reference Nizard R, the GUEPAR group (2002) Computer assisted surgery for total knee arthroplasty. Acta Orthop Belgica 68:215–230 Nizard R, the GUEPAR group (2002) Computer assisted surgery for total knee arthroplasty. Acta Orthop Belgica 68:215–230
9.
go back to reference Oswald MH, Jakob RP, Schneider E et al (1993) Radiological analysis of normal axial alignment of femur and tibia in view of total knee arthroplasty. J Arthroplasty 8:419–426PubMed Oswald MH, Jakob RP, Schneider E et al (1993) Radiological analysis of normal axial alignment of femur and tibia in view of total knee arthroplasty. J Arthroplasty 8:419–426PubMed
10.
go back to reference Saragaglia D, Picard F, Chaussard C et al (2001) Computer-assisted knee arthroplasty: comparison with a conventional procedure. Results of 50 cases in a prospective randomized study. Rev Chir Orthop Reparatrice Appar Mot 87:18–28PubMed Saragaglia D, Picard F, Chaussard C et al (2001) Computer-assisted knee arthroplasty: comparison with a conventional procedure. Results of 50 cases in a prospective randomized study. Rev Chir Orthop Reparatrice Appar Mot 87:18–28PubMed
11.
go back to reference Sparmann M, Wolke B, Czupalla H et al (2003) Positioning of total knee arthroplasty with and without navigation support. J Bone Joint Surg Br 85:830–835PubMed Sparmann M, Wolke B, Czupalla H et al (2003) Positioning of total knee arthroplasty with and without navigation support. J Bone Joint Surg Br 85:830–835PubMed
12.
go back to reference Stindel E, Briard JL, Merloz P et al (2002) Bone morphing: 3D morphological data for total knee arthroplasty. Comput Aided Surg 7:156–168CrossRefPubMed Stindel E, Briard JL, Merloz P et al (2002) Bone morphing: 3D morphological data for total knee arthroplasty. Comput Aided Surg 7:156–168CrossRefPubMed
13.
go back to reference Stulberg SD (2003) How accurate is current TKR instrumentation? Clin Orthop 416:177–189PubMed Stulberg SD (2003) How accurate is current TKR instrumentation? Clin Orthop 416:177–189PubMed
14.
go back to reference Stulberg SD, Picard F, Saragaglia D (2000) Computer-assisted total knee replacement arthroplasty. Op Tech Orthop 10:25–39 Stulberg SD, Picard F, Saragaglia D (2000) Computer-assisted total knee replacement arthroplasty. Op Tech Orthop 10:25–39
15.
go back to reference Stulberg SD, Beng PL, Sarin V (2002) Computer-assisted navigation in total knee replacement: results of an initial experience in thirty-five patients. J Bone Joint Surg Am Suppl 84:90–98 Stulberg SD, Beng PL, Sarin V (2002) Computer-assisted navigation in total knee replacement: results of an initial experience in thirty-five patients. J Bone Joint Surg Am Suppl 84:90–98
16.
go back to reference Tillet E, Engh G, Petersen T (1988) A comparative study of extramedullary and intramedullary alignment systems in total knee arthroplasty. Clin Orthop 230:176–181PubMed Tillet E, Engh G, Petersen T (1988) A comparative study of extramedullary and intramedullary alignment systems in total knee arthroplasty. Clin Orthop 230:176–181PubMed
Metadata
Title
Prosthetic alignment and sizing in computer-assisted total knee arthroplasty
Authors
Tomoyuki Matsumoto
Nobuhiro Tsumura
Masahiro Kurosaka
Hirotsugu Muratsu
Ryosuke Kuroda
Katsuhiko Ishimoto
Kazuo Tsujimoto
Ryoichi Shiba
Shinichi Yoshiya
Publication date
01-10-2004
Publisher
Springer-Verlag
Published in
International Orthopaedics / Issue 5/2004
Print ISSN: 0341-2695
Electronic ISSN: 1432-5195
DOI
https://doi.org/10.1007/s00264-004-0562-1

Other articles of this Issue 5/2004

International Orthopaedics 5/2004 Go to the issue