Abstract

Between September 2000 and February 2002 we inserted 120 total knee arthroplasties. In 60 patients we used the standard technique, and in 60 patients we used the OrthoPilot navigation system. Postoperatively all patients had standing long radiographs of the lower extremity from the hip joint to the ankle. We considered the ideal value of the anatomic lateral tibiofemoral angle (LTFA) to be 174°. In the standard group the mean value of LTFA was 174.9° and in the navigation group 174.3°. A deviation between 0° and 2° from the ideal value was seen in 42 cases in the standard group and in 53 cases in the navigation group. In the standard group 18 cases had a deviation of more than 2.1°, whereas there were only seven cases in the navigation group with a deviation exceeding 2.1°. There were no complications related to the use of the navigation system. The system affords a possibility to place femoral and tibial components precisely with less axis deviation than with the conventional technique.
Literature
1.
go back to reference Bargren JH, Blaha JD, Freeman MAR (1983) Alignment in total knee arthroplasty. Clin Orthop 173:178–183PubMed Bargren JH, Blaha JD, Freeman MAR (1983) Alignment in total knee arthroplasty. Clin Orthop 173:178–183PubMed
2.
go back to reference Delp SL, Stulberg SD, Davies B, Picard F, Leitner F (1998) Computer assisted knee replacement. Clin Orthop 354:49–56 Delp SL, Stulberg SD, Davies B, Picard F, Leitner F (1998) Computer assisted knee replacement. Clin Orthop 354:49–56
3.
go back to reference Elloy MA, Manning MP, Johnson R (1992) Accuracy of intramedullary alignment in total knee replacement. J Biomed 14:363–370 Elloy MA, Manning MP, Johnson R (1992) Accuracy of intramedullary alignment in total knee replacement. J Biomed 14:363–370
4.
go back to reference Gossé F, Brack C, Gotte H, Roth M, Ruhmann O, Schweikard A, Vahldiek M (1997) Roboterunterstützung in der Knieendoprothetik. Orthopäde 26:258–266 Gossé F, Brack C, Gotte H, Roth M, Ruhmann O, Schweikard A, Vahldiek M (1997) Roboterunterstützung in der Knieendoprothetik. Orthopäde 26:258–266
5.
go back to reference Jeffery RS, Morris RW, Denham RA (1991) Coronal alignment after total knee replacement. J Bone Joint Surg [Br] 73:709–714 Jeffery RS, Morris RW, Denham RA (1991) Coronal alignment after total knee replacement. J Bone Joint Surg [Br] 73:709–714
6.
go back to reference Jenny JY, Boeri C (2001) Navigiert implantierte Knietotalendoprothesen—eine Vergleichsstudie zum konvetionellen Instrumentarium. Z Orthop 139:117–119CrossRefPubMed Jenny JY, Boeri C (2001) Navigiert implantierte Knietotalendoprothesen—eine Vergleichsstudie zum konvetionellen Instrumentarium. Z Orthop 139:117–119CrossRefPubMed
7.
go back to reference Katz MM, Hungerford DS, Krakow KA, Lennox DW (1987) Results of total knee arthroplasty after failed proximal tibial osteotomy for osteoarthritis. J Bone Joint Surg [Am] 69:225–233 Katz MM, Hungerford DS, Krakow KA, Lennox DW (1987) Results of total knee arthroplasty after failed proximal tibial osteotomy for osteoarthritis. J Bone Joint Surg [Am] 69:225–233
8.
go back to reference Lonner JH, Laird MT, Stuchin SA (1996) Effect of rotation and knee flexion on radiographic alignment in total knee arthroplasties. Clin Orthop 331:102–106 Lonner JH, Laird MT, Stuchin SA (1996) Effect of rotation and knee flexion on radiographic alignment in total knee arthroplasties. Clin Orthop 331:102–106
9.
go back to reference Lotke PA, Ecker ML (1977) Influence of positioning of prosthesis in total knee replacement. J Bone Joint Surg [Am] 59:77–79 Lotke PA, Ecker ML (1977) Influence of positioning of prosthesis in total knee replacement. J Bone Joint Surg [Am] 59:77–79
10.
go back to reference Mielke RK, Clemens U, Jens JH, Kershally S (2001) Navigation in der Knieendoprothetik—vorläufige klinische Erfahrungen und prospektiv vergleichende Studie gegenüber konventioneller Implantationstechnik. Z Orthop 139:100–116 Mielke RK, Clemens U, Jens JH, Kershally S (2001) Navigation in der Knieendoprothetik—vorläufige klinische Erfahrungen und prospektiv vergleichende Studie gegenüber konventioneller Implantationstechnik. Z Orthop 139:100–116
11.
go back to reference Oswald MH, Jakob RP, Schneider E, Hoogewood HM (1993) Radiological analysis of normal axial alignment of femur and tibia in view of total knee arthroplasty. J Arthroplasty 8:419–426PubMed Oswald MH, Jakob RP, Schneider E, Hoogewood HM (1993) Radiological analysis of normal axial alignment of femur and tibia in view of total knee arthroplasty. J Arthroplasty 8:419–426PubMed
12.
go back to reference Patel DV, Ferris BD, Aichroth PM (1991) Radiological study of alignment after total knee replacement. Int Ortop 15:209–210 Patel DV, Ferris BD, Aichroth PM (1991) Radiological study of alignment after total knee replacement. Int Ortop 15:209–210
13.
go back to reference Petersen TL, Engh GA (1988) Radiographic assessment of knee alignment after total knee arthroplasty. J Arthroplasty 1:67–72 Petersen TL, Engh GA (1988) Radiographic assessment of knee alignment after total knee arthroplasty. J Arthroplasty 1:67–72
14.
go back to reference Prakash U, Wigderowitz CA, McGurty DW, Rowley DI (2001) Computerised measurement of tibiofemoral alignment. J Bone Joint Surg [Br] 83:819–824 Prakash U, Wigderowitz CA, McGurty DW, Rowley DI (2001) Computerised measurement of tibiofemoral alignment. J Bone Joint Surg [Br] 83:819–824
15.
go back to reference Ritter MA, Faris PM, Keating EM, Meding JB (1994) Postoperative alignment of total knee replacement. Its effect on survival. Clin Orthop 299:153–156PubMed Ritter MA, Faris PM, Keating EM, Meding JB (1994) Postoperative alignment of total knee replacement. Its effect on survival. Clin Orthop 299:153–156PubMed
16.
go back to reference Saleh KJ, Sherman P, Katkin P, Windsor R et al (2001) Total knee arthroplasty after open reduction and internal fixation of fractures of the tibial plateau. J Bone Joint Surg [Am] 83:1144–1148 Saleh KJ, Sherman P, Katkin P, Windsor R et al (2001) Total knee arthroplasty after open reduction and internal fixation of fractures of the tibial plateau. J Bone Joint Surg [Am] 83:1144–1148
17.
go back to reference Stulberg SD, Loan P, Sarin V (2002) Computer-assisted navigation in total knee replacement: results of an initial experience in thirty-five patients. J Bone Joint Surg [Am] 84:90–98 Stulberg SD, Loan P, Sarin V (2002) Computer-assisted navigation in total knee replacement: results of an initial experience in thirty-five patients. J Bone Joint Surg [Am] 84:90–98
18.
go back to reference Toksvig-Larsen S et al (1998) Fixation of the tibial component of total knee arthroplasty after high tibial osteotomy. J Bone Joint Surg [Br] 80:295–297 Toksvig-Larsen S et al (1998) Fixation of the tibial component of total knee arthroplasty after high tibial osteotomy. J Bone Joint Surg [Br] 80:295–297
19.
go back to reference Townley ChO (1985) The anatomic total knee resurfacing arthroplasty. Clin Orthop 192:82–96PubMed Townley ChO (1985) The anatomic total knee resurfacing arthroplasty. Clin Orthop 192:82–96PubMed
20.
go back to reference Waugh MTW (1985) Tibiofemoral alignment and the results of knee replacement. J Bone Joint Surg [Br] 67:551–556 Waugh MTW (1985) Tibiofemoral alignment and the results of knee replacement. J Bone Joint Surg [Br] 67:551–556
21.
go back to reference Windsor RE, Insall JN, Vince KG (1988) Technical considerations of total knee arthroplasty after proximal tibial osteotomy. J Bone Joint Surg [Am] 70:547–555 Windsor RE, Insall JN, Vince KG (1988) Technical considerations of total knee arthroplasty after proximal tibial osteotomy. J Bone Joint Surg [Am] 70:547–555
Metadata
Title
Total knee arthroplasty implanted with and without kinematic navigation
Authors
R. Hart
M. Janeček
A. Chaker
P. Buček
Publication date
01-12-2003
Publisher
Springer-Verlag
Published in
International Orthopaedics / Issue 6/2003
Print ISSN: 0341-2695
Electronic ISSN: 1432-5195
DOI
https://doi.org/10.1007/s00264-003-0501-6

Other articles of this Issue 6/2003

International Orthopaedics 6/2003 Go to the issue