Skip to main content
Top
Published in: Archives of Osteoporosis 1/2021

01-12-2021 | Magnetic Resonance Imaging | Original Article

Fast kilovoltage (KV)-switching dual-energy CT virtual noncalcium technique using different reconstruction kernels for identifying acute and chronic vertebral compression fractures

Authors: Luyou Yan, Zeya Zhong, Hui Gao, Yewen He, Ping Li, Hongrong Shen, Shuwei Zhou, Ying Guo, Liangying Liao, Kun Zhang

Published in: Archives of Osteoporosis | Issue 1/2021

Login to get access

Abstract

Summary

The vertebral compression fractures (VCFs) represent an incidental finding on thoracic and abdominal dual-energy CT examinations (which use STND reconstruction kernel), which are associated with increased mortality. While the BONE reconstruction kernel shows a superior diagnostic accuracy to find fractures. This study showed STND and BONE reconstruction kernel both had excellent diagnostic performance to detect abnormal edema in acute VCFs.

Purpose

To investigate whether different reconstruction kernels (STND V.S. BONE) affect the diagnostic performance of dual-energy CT virtual noncalcium technique (VNCa) for identifying acute and chronic vertebral compression fractures (VCFs).

Methods

This retrospective study included 31 consecutive patients with 79 VCFs who underwent both a dual-energy CT and a 3-T MR examination of the spine between August 2018 and March 2019. MR images served as the reference standard. Two independent and blinded radiologists evaluated all vertebral bodies for the presence of abnormal edema on color-coded overlay VNCa images. Two additional radiologists performed a quantitative analysis on VNCa images by calculating water content of vertebral bodies. Receiver operating characteristic curve (ROC) analysis was conducted. Area under the curve (AUC) was calculated.

Results

MR imaging depicted 44 edematous and 35 nonedematous VCFs. In visual analysis, the AUCSTND and AUCBONE were 0.932 and 0.943. In quantitative analysis, water content results were significantly different between vertebrae with and without bone marrow edema on MR (P < 0.001). And the AUCSTND and AUCBONE were 0.851 and 0.850 respectively.

Conclusion

Visual and quantitative analysis of dual-energy CT VNCa technique had excellent diagnostic performance for identifying acute and chronic compression fractures; different reconstruction kernels did not matter.
Appendix
Available only for authorised users
Literature
1.
go back to reference Burns JE, Yao J, Summers RM (2017) Vertebral body compression fractures and bone density: automated detection and classification on CT images. Radiology 284(3):788–797CrossRef Burns JE, Yao J, Summers RM (2017) Vertebral body compression fractures and bone density: automated detection and classification on CT images. Radiology 284(3):788–797CrossRef
2.
go back to reference Center JR, Nguyen TV, Schneider D, Sambrook PN, Eisman JA (1999) Mortality after all major types of osteoporotic fracture in men and women: an observational study. The Lancet 353(9156):878–882CrossRef Center JR, Nguyen TV, Schneider D, Sambrook PN, Eisman JA (1999) Mortality after all major types of osteoporotic fracture in men and women: an observational study. The Lancet 353(9156):878–882CrossRef
3.
go back to reference McCarthy J, Davis A (2016) Diagnosis and management of vertebral compression fractures. Am Fam Physician 94(1):44–50PubMed McCarthy J, Davis A (2016) Diagnosis and management of vertebral compression fractures. Am Fam Physician 94(1):44–50PubMed
4.
go back to reference Chan PL, Reddy T, Milne D et al (2012) Incidental vertebral fractures on computed tomography. N Z Med J 125(1350):45–50PubMed Chan PL, Reddy T, Milne D et al (2012) Incidental vertebral fractures on computed tomography. N Z Med J 125(1350):45–50PubMed
5.
go back to reference Goldstein CL, Chutkan NB, Choma TJ, Douglas OR (2015) Management of the elderly with vertebral compression fractures. Neurosurgery 77(Suppl 4):S33-45CrossRef Goldstein CL, Chutkan NB, Choma TJ, Douglas OR (2015) Management of the elderly with vertebral compression fractures. Neurosurgery 77(Suppl 4):S33-45CrossRef
6.
go back to reference Williams AL, Al-Busaidi A, Sparrow PJ, Adams JE, Whitehouse RW (2009) Under-reporting of osteoporotic vertebral fractures on computed tomography. Eur J Radiol 69(1):179–183CrossRef Williams AL, Al-Busaidi A, Sparrow PJ, Adams JE, Whitehouse RW (2009) Under-reporting of osteoporotic vertebral fractures on computed tomography. Eur J Radiol 69(1):179–183CrossRef
7.
go back to reference Bartalena T, Giannelli G, Rinaldi MF et al (2009) Prevalence of thoracolumbar vertebral fractures on multidetector CT: Underreporting by radiologists. Eur J Radiol 69(3):555–559CrossRef Bartalena T, Giannelli G, Rinaldi MF et al (2009) Prevalence of thoracolumbar vertebral fractures on multidetector CT: Underreporting by radiologists. Eur J Radiol 69(3):555–559CrossRef
8.
go back to reference Frellesen C, Azadegan M, Martin SS, Otani K, Wichmann JL (2018) Dual-energy computed tomography–based display of bone marrow edema in incidental vertebral compression fractures: diagnostic accuracy and characterization in oncological patients undergoing routine staging computed tomography. Invest Radiol 53(7):409–416CrossRef Frellesen C, Azadegan M, Martin SS, Otani K, Wichmann JL (2018) Dual-energy computed tomography–based display of bone marrow edema in incidental vertebral compression fractures: diagnostic accuracy and characterization in oncological patients undergoing routine staging computed tomography. Invest Radiol 53(7):409–416CrossRef
9.
go back to reference Dewar C (2015) Diagnosis and treatment of vertebral compression fractures. Radiol Technol 86(3):301–320 (quiz 321–303)PubMed Dewar C (2015) Diagnosis and treatment of vertebral compression fractures. Radiol Technol 86(3):301–320 (quiz 321–303)PubMed
10.
go back to reference Carberry GA, Pooler BD, Binkley N, Lauder TB, Bruce RJ, Pickhardt PJ (2013) Unreported vertebral body compression fractures at abdominal multidetector CT. Radiology 268(1):120–126CrossRef Carberry GA, Pooler BD, Binkley N, Lauder TB, Bruce RJ, Pickhardt PJ (2013) Unreported vertebral body compression fractures at abdominal multidetector CT. Radiology 268(1):120–126CrossRef
11.
go back to reference Epstein NE, Hollingsworth R (2015) Diagnosis and management of traumatic cervical central spinal cord injury: a review. Surg Neurol Int 6(Suppl 4):S140-153CrossRef Epstein NE, Hollingsworth R (2015) Diagnosis and management of traumatic cervical central spinal cord injury: a review. Surg Neurol Int 6(Suppl 4):S140-153CrossRef
12.
go back to reference Kellock TT, Nicolaou S, Kim SSY et al (2017) Detection of bone marrow edema in nondisplaced hip fractures: utility of a virtual noncalcium dual-energy CT application. Radiology 284(3):798–805CrossRef Kellock TT, Nicolaou S, Kim SSY et al (2017) Detection of bone marrow edema in nondisplaced hip fractures: utility of a virtual noncalcium dual-energy CT application. Radiology 284(3):798–805CrossRef
13.
go back to reference Kaup M, Wichmann JL, Scholtz JE et al (2016) Dual-energy CT-based display of bone marrow edema in osteoporotic vertebral compression fractures: impact on diagnostic accuracy of radiologists with varying levels of experience in correlation to MR imaging. Radiology 280(2):510–519CrossRef Kaup M, Wichmann JL, Scholtz JE et al (2016) Dual-energy CT-based display of bone marrow edema in osteoporotic vertebral compression fractures: impact on diagnostic accuracy of radiologists with varying levels of experience in correlation to MR imaging. Radiology 280(2):510–519CrossRef
14.
go back to reference Wang CK, Tsai JM, Chuang MT, Wang MT, Huang KY, Lin RM (2013) Bone marrow edema in vertebral compression fractures: detection with dual-energy CT. Radiology 269(2):525–533CrossRef Wang CK, Tsai JM, Chuang MT, Wang MT, Huang KY, Lin RM (2013) Bone marrow edema in vertebral compression fractures: detection with dual-energy CT. Radiology 269(2):525–533CrossRef
15.
go back to reference Guggenberger R, Gnannt R, Hodler J et al (2012) Diagnostic performance of dual-energy CT for the detection of traumatic bone marrow lesions in the ankle: comparison with MR imaging. Radiology 264(1):164–173CrossRef Guggenberger R, Gnannt R, Hodler J et al (2012) Diagnostic performance of dual-energy CT for the detection of traumatic bone marrow lesions in the ankle: comparison with MR imaging. Radiology 264(1):164–173CrossRef
16.
go back to reference Petritsch B, Kosmala A, Weng AM et al (2017) Vertebral compression fractures: third-generation dual-energy CT for detection of bone marrow edema at visual and quantitative analyses. Radiology 284(1):161–168CrossRef Petritsch B, Kosmala A, Weng AM et al (2017) Vertebral compression fractures: third-generation dual-energy CT for detection of bone marrow edema at visual and quantitative analyses. Radiology 284(1):161–168CrossRef
17.
go back to reference Akisato K et al (2020) Dual-energy CT of material decomposition analysis for detection with bone marrow edema in patients with vertebral compression fractures. Acad Radiol 27(2):227–232CrossRef Akisato K et al (2020) Dual-energy CT of material decomposition analysis for detection with bone marrow edema in patients with vertebral compression fractures. Acad Radiol 27(2):227–232CrossRef
18.
go back to reference Eastell R, Cedel SC, Wahner HW et al (1991) Classification of vertebral fractures. J Bone Miner Res 6:207–215CrossRef Eastell R, Cedel SC, Wahner HW et al (1991) Classification of vertebral fractures. J Bone Miner Res 6:207–215CrossRef
19.
go back to reference Black DM, Cummings SR, Karpf DB et al (1996) For the Fracture Intervention Trial Research Group. Randomised trial of the effect of alendronate on risk of fracture in women with existing vertebral fractures. Lancet 348:1535–1541CrossRef Black DM, Cummings SR, Karpf DB et al (1996) For the Fracture Intervention Trial Research Group. Randomised trial of the effect of alendronate on risk of fracture in women with existing vertebral fractures. Lancet 348:1535–1541CrossRef
20.
go back to reference Black DM, Palermo L, Nevitt MC et al (1991) Defining incident vertebral deformity: a prospective comparison of several approaches. J Bone Miner Res 14:90–101CrossRef Black DM, Palermo L, Nevitt MC et al (1991) Defining incident vertebral deformity: a prospective comparison of several approaches. J Bone Miner Res 14:90–101CrossRef
21.
go back to reference Riggs BL, Seeman E, Hodgson SF et al (1982) Effect of the fluoride/calcium regimen on vertebral fracture occurrence in postmenopausal osteoporosis. N Engl J Med 306:446–450CrossRef Riggs BL, Seeman E, Hodgson SF et al (1982) Effect of the fluoride/calcium regimen on vertebral fracture occurrence in postmenopausal osteoporosis. N Engl J Med 306:446–450CrossRef
22.
go back to reference Watts NB, Harris SF, Genant HK (1990) Intermittent cyclical etidronate treatment of post-menopausal osteoporosis. N Engl J Med 323:73–79CrossRef Watts NB, Harris SF, Genant HK (1990) Intermittent cyclical etidronate treatment of post-menopausal osteoporosis. N Engl J Med 323:73–79CrossRef
23.
go back to reference Minne HW, Leidig G, Wuster C et al (1988) A newly developed spine deformity index (SDI) to quantitate vertebral crush fractures in patients with osteoporosis. Bone Miner 3:335–349PubMed Minne HW, Leidig G, Wuster C et al (1988) A newly developed spine deformity index (SDI) to quantitate vertebral crush fractures in patients with osteoporosis. Bone Miner 3:335–349PubMed
24.
go back to reference Schwartz EN, Steinberg D (2005) Detection of vertebral fractures. Curr Osteoporos Rep 3(4):126–135CrossRef Schwartz EN, Steinberg D (2005) Detection of vertebral fractures. Curr Osteoporos Rep 3(4):126–135CrossRef
25.
go back to reference Kalender WA, Perman WH, Vetter JR, Klotz E (1986) Evaluation of a prototype dual-energy computed tomographic apparatus I. Phantom studies. Med Phys 13(3):334–339CrossRef Kalender WA, Perman WH, Vetter JR, Klotz E (1986) Evaluation of a prototype dual-energy computed tomographic apparatus I. Phantom studies. Med Phys 13(3):334–339CrossRef
26.
go back to reference Mallinson PI (2016) Dual-energy CT for the musculoskeletal system. Radiology 281(3):690–707CrossRef Mallinson PI (2016) Dual-energy CT for the musculoskeletal system. Radiology 281(3):690–707CrossRef
27.
go back to reference Bierry G, Venkatasamy A, Kremer S, Dosch JC, Dietemann JL (2014) Dual-energy CT in vertebral compression fractures: performance of visual and quantitative analysis for bone marrow edema demonstration with comparison to MRI. Skeletal Radiol 43(4):485–492CrossRef Bierry G, Venkatasamy A, Kremer S, Dosch JC, Dietemann JL (2014) Dual-energy CT in vertebral compression fractures: performance of visual and quantitative analysis for bone marrow edema demonstration with comparison to MRI. Skeletal Radiol 43(4):485–492CrossRef
28.
go back to reference Akisato K, Nishihara R, Okazaki H et al (2019) Dual-energy CT of material decomposition analysis for detection with bone marrow edema in patients with vertebral compression fractures. Acad Radiol 27(2):227–232CrossRef Akisato K, Nishihara R, Okazaki H et al (2019) Dual-energy CT of material decomposition analysis for detection with bone marrow edema in patients with vertebral compression fractures. Acad Radiol 27(2):227–232CrossRef
29.
go back to reference Diekhoff T, Engelhard N, Fuchs M et al (2019) Single-source dual-energy computed tomography for the assessment of bone marrow oedema in vertebral compression fractures: a prospective diagnostic accuracy study. Eur Radiol 29(1):31–39CrossRef Diekhoff T, Engelhard N, Fuchs M et al (2019) Single-source dual-energy computed tomography for the assessment of bone marrow oedema in vertebral compression fractures: a prospective diagnostic accuracy study. Eur Radiol 29(1):31–39CrossRef
30.
go back to reference Kosmala A, Weng AM, Heidemeier A et al (2018) Multiple myeloma and dual-energy CT: diagnostic accuracy of virtual noncalcium technique for detection of bone marrow infiltration of the spine and pelvis. Radiology 286(1):205–213CrossRef Kosmala A, Weng AM, Heidemeier A et al (2018) Multiple myeloma and dual-energy CT: diagnostic accuracy of virtual noncalcium technique for detection of bone marrow infiltration of the spine and pelvis. Radiology 286(1):205–213CrossRef
31.
go back to reference Schwaiger BJ, Gersing AS, Hammel J et al (2018) Three-material decomposition with dual-layer spectral CT compared to MRI for the detection of bone marrow edema in patients with acute vertebral fractures. Skeletal Radiol 47:1533–1540CrossRef Schwaiger BJ, Gersing AS, Hammel J et al (2018) Three-material decomposition with dual-layer spectral CT compared to MRI for the detection of bone marrow edema in patients with acute vertebral fractures. Skeletal Radiol 47:1533–1540CrossRef
32.
go back to reference Neuhaus V, Lennartz S, Abdullayev N et al (2018) Bone marrow edema in traumatic vertebral compression fractures: diagnostic accuracy of dual-layer detector CT using calcium suppressed images. Eur J Radiol 105:216–220CrossRef Neuhaus V, Lennartz S, Abdullayev N et al (2018) Bone marrow edema in traumatic vertebral compression fractures: diagnostic accuracy of dual-layer detector CT using calcium suppressed images. Eur J Radiol 105:216–220CrossRef
33.
go back to reference Mandalia V, Henson JH (2008) Traumatic bone bruising–a review article. Eur J Radiol 67(1):54–61CrossRef Mandalia V, Henson JH (2008) Traumatic bone bruising–a review article. Eur J Radiol 67(1):54–61CrossRef
34.
go back to reference Suh CH, Yun SJ, Jin W, Lee SH, Park SY, Ryu CW (2018) Diagnostic performance of dual-energy CT for the detection of bone marrow oedema: a systematic review and meta-analysis. Eur Radiol 28(10):4182–4194CrossRef Suh CH, Yun SJ, Jin W, Lee SH, Park SY, Ryu CW (2018) Diagnostic performance of dual-energy CT for the detection of bone marrow oedema: a systematic review and meta-analysis. Eur Radiol 28(10):4182–4194CrossRef
35.
go back to reference Pache G, Bulla S, Baumann T et al (2012) Dose reduction does not affect detection of bone marrow lesions with dual-energy CT virtual noncalcium technique. Acad Radiol 19(12):1539–1545CrossRef Pache G, Bulla S, Baumann T et al (2012) Dose reduction does not affect detection of bone marrow lesions with dual-energy CT virtual noncalcium technique. Acad Radiol 19(12):1539–1545CrossRef
Metadata
Title
Fast kilovoltage (KV)-switching dual-energy CT virtual noncalcium technique using different reconstruction kernels for identifying acute and chronic vertebral compression fractures
Authors
Luyou Yan
Zeya Zhong
Hui Gao
Yewen He
Ping Li
Hongrong Shen
Shuwei Zhou
Ying Guo
Liangying Liao
Kun Zhang
Publication date
01-12-2021
Publisher
Springer London
Published in
Archives of Osteoporosis / Issue 1/2021
Print ISSN: 1862-3522
Electronic ISSN: 1862-3514
DOI
https://doi.org/10.1007/s11657-021-00948-z

Other articles of this Issue 1/2021

Archives of Osteoporosis 1/2021 Go to the issue