Skip to main content
Top
Published in: Sleep and Breathing 3/2019

Open Access 01-09-2019 | Sleep Breathing Physiology and Disorders • Original Article

Utility of transthoracic impedance and novel algorithm for sleep apnea screening in pacemaker patient

Authors: RuoHan Chen, KePing Chen, Yan Dai, Shu Zhang

Published in: Sleep and Breathing | Issue 3/2019

Login to get access

Abstract

Background

Pacing patients was revealed with a high prevalence of sleep disorder, but mostly undiagnosed. The pacemaker with transthoracic impedance sensor and novel algorithm could identify sleep apnea (SA) event. This study aimed to evaluate accuracy of pacemaker in sleep apnea diagnosis.

Methods

This is a prospective study which enrolled patients implanted with pacemakers integrated with transthoracic impedance sensor and SA-identified algorithm (AP Scan). All patients underwent a polysomnography (PSG). The apnea and hypopnea index (AHI) of the PSG (PSG-AHI) and the respiratory disturbance index (RDI) of the pacemaker (PM-RDI) were recorded on the same night. The correlation between two methods was evaluated by the kappa coefficient, receiver operating characteristic (ROC) curves, and Bland and Altman statistics.

Results

Sixty-four patients were enrolled, who had never been diagnosed with SAS or underwent PSG exam. After PSG examination, 76.4% patients were diagnosed as combining with SA (20% severe, 18.2% moderate, and 38.2% mild). RDI calculated by PM has a strong positive correlation with PSG-AHI (r = 0.76, p < 0.001, 95% CI 0.61–0.85). The optimal cutoff value of PM-RDI for advanced SAS (PSG-AHI ≥ 15) diagnosis was 26, with AUC of 0.89 (95% CI 0.77 to 0.96, p < 0.001). The best cutoff value for severe SA (PSG-AHI ≥ 30) identification was 41, with a sensitivity of 81.6%, a specificity of 88.6%.

Conclusions

Pacemaker patients present a high prevalence of undiagnosed SA. Detection of SA by pacemaker is feasible and accurate in SA screening and monitoring.
Literature
1.
go back to reference Heinzer R, Vat S, Marques-Vidal P et al (2015) Prevalence of sleep-disordered breathing in the general population: the HypnoLaus study. Lancet Respir Med 3(4):310e8CrossRef Heinzer R, Vat S, Marques-Vidal P et al (2015) Prevalence of sleep-disordered breathing in the general population: the HypnoLaus study. Lancet Respir Med 3(4):310e8CrossRef
2.
go back to reference Peppard PE, Young T, Palta M, Skatrud J (2000) Prospective study of the association between sleep-disordered breathing and hypertension. N Engl J Med 342:1378–1384CrossRefPubMed Peppard PE, Young T, Palta M, Skatrud J (2000) Prospective study of the association between sleep-disordered breathing and hypertension. N Engl J Med 342:1378–1384CrossRefPubMed
3.
go back to reference Bradley TD, Floras JS (2003) Sleep apnea and heart failure: part I: obstructive sleep apnea. Circulation 107:1671–1678CrossRefPubMed Bradley TD, Floras JS (2003) Sleep apnea and heart failure: part I: obstructive sleep apnea. Circulation 107:1671–1678CrossRefPubMed
4.
go back to reference Bradley TD, Floras JS (2003) Sleep apnea and heart failure: part II: central sleep apnea. Circulation 107:1822–1826CrossRefPubMed Bradley TD, Floras JS (2003) Sleep apnea and heart failure: part II: central sleep apnea. Circulation 107:1822–1826CrossRefPubMed
5.
go back to reference Garrigue S, Pepin JL, Defaye P et al (2007) High prevalence of sleep apnea syndrome in patients with long-term pacing: the European multicenter polysomnographic study. Circulation 115(13):1703e9CrossRef Garrigue S, Pepin JL, Defaye P et al (2007) High prevalence of sleep apnea syndrome in patients with long-term pacing: the European multicenter polysomnographic study. Circulation 115(13):1703e9CrossRef
6.
go back to reference Cole CR, Jensen DN, Cho Y et al (2001) Correlation of impedance minute ventilation with measured minute ventilation in a rate responsive pacemaker. Pacing Clin Electrophysiol 24:989–993CrossRefPubMed Cole CR, Jensen DN, Cho Y et al (2001) Correlation of impedance minute ventilation with measured minute ventilation in a rate responsive pacemaker. Pacing Clin Electrophysiol 24:989–993CrossRefPubMed
7.
go back to reference Fox H, Nölker G, Gutleben KJ, Bitter T, Horstkotte D, Oldenburg O (2014) Reliability and accuracy of sleep apnea scans in novel cardiac resynchronization therapy devices: an independent report of two cases. Herzschrittmacherther Elektrophysiol 25(1):53–55CrossRefPubMed Fox H, Nölker G, Gutleben KJ, Bitter T, Horstkotte D, Oldenburg O (2014) Reliability and accuracy of sleep apnea scans in novel cardiac resynchronization therapy devices: an independent report of two cases. Herzschrittmacherther Elektrophysiol 25(1):53–55CrossRefPubMed
8.
go back to reference Defaye P, de la Cruz I, Martí-Almor J et al (2014) A pacemaker transthoracic impedance sensor with an advanced algorithm to identify severe sleep apnea: the DREAM European study. Heart Rhythm 11(5):842e8CrossRef Defaye P, de la Cruz I, Martí-Almor J et al (2014) A pacemaker transthoracic impedance sensor with an advanced algorithm to identify severe sleep apnea: the DREAM European study. Heart Rhythm 11(5):842e8CrossRef
9.
go back to reference Zhang S, Hua W, Huang D et al (2010) Current knowledge and recommendations of implantable pacemaker therapy (update 2010). Chin J Card Arrhthm 14(4):245–267 Zhang S, Hua W, Huang D et al (2010) Current knowledge and recommendations of implantable pacemaker therapy (update 2010). Chin J Card Arrhthm 14(4):245–267
10.
go back to reference Bhat S, Upadhyay H, DeBari VA et al (2016) The utility of patient-completed and partner-completed Epworth Sleepiness Scale scores in the evaluation of obstructive sleep apnea. Sleep Breath 20(4):1347–1354CrossRefPubMed Bhat S, Upadhyay H, DeBari VA et al (2016) The utility of patient-completed and partner-completed Epworth Sleepiness Scale scores in the evaluation of obstructive sleep apnea. Sleep Breath 20(4):1347–1354CrossRefPubMed
11.
go back to reference Berry RB, Budhiraja R, Gottlieb DJ, Gozal D, Iber C, Kapur VK, Marcus CL, Mehra R, Parthasarathy S, Quan SF, Redline S, Strohl KP, Davidson Ward SL, Tangredi MM, American Academy of Sleep Medicine (2012) Rules for scoring respiratory events in sleep: update of the 2007 AASM manual for the scoring of sleep and associated events. Deliberations of the sleep apnea definitions task force of the American Academy of sleep medicine. J Clin Sleep Med 8:597–619PubMedPubMedCentral Berry RB, Budhiraja R, Gottlieb DJ, Gozal D, Iber C, Kapur VK, Marcus CL, Mehra R, Parthasarathy S, Quan SF, Redline S, Strohl KP, Davidson Ward SL, Tangredi MM, American Academy of Sleep Medicine (2012) Rules for scoring respiratory events in sleep: update of the 2007 AASM manual for the scoring of sleep and associated events. Deliberations of the sleep apnea definitions task force of the American Academy of sleep medicine. J Clin Sleep Med 8:597–619PubMedPubMedCentral
12.
go back to reference Shalaby A, Atwood C, Hansen C et al (2006) Feasibility of automated detection of advanced sleep disordered breathing utilizing an implantable pacemaker ventilation sensor. Pace 29(8):1036–1043CrossRefPubMed Shalaby A, Atwood C, Hansen C et al (2006) Feasibility of automated detection of advanced sleep disordered breathing utilizing an implantable pacemaker ventilation sensor. Pace 29(8):1036–1043CrossRefPubMed
13.
go back to reference Zou D, Grote L, Peker Y et al (2006) Validation a portable monitoring device for sleep apnea diagnosis in a population based cohort using synchronized home polysomnography. Sleep 29(3):367–374CrossRefPubMed Zou D, Grote L, Peker Y et al (2006) Validation a portable monitoring device for sleep apnea diagnosis in a population based cohort using synchronized home polysomnography. Sleep 29(3):367–374CrossRefPubMed
14.
go back to reference Weimin L, Rongguang W, Dongyan H, Xiaoli L, Wei J, Shiming Y (2013) Assessment of portable monitoring device WatchPAT 200 in the diagnosis of obstructive sleep apnea. Eur Arch Otorhinolaryngol 270(12):3099–3105CrossRefPubMed Weimin L, Rongguang W, Dongyan H, Xiaoli L, Wei J, Shiming Y (2013) Assessment of portable monitoring device WatchPAT 200 in the diagnosis of obstructive sleep apnea. Eur Arch Otorhinolaryngol 270(12):3099–3105CrossRefPubMed
15.
go back to reference Cao Y, Zhang Y, Su Y, Bai J, Wang W, Ge J (2015) Assessment of adaptive rate response provided by accelerometer, minute ventilation and dual sensor compared with normal sinus rhythm during exercise: a self-controlled study in chronotropically competent subjects. Chin Med J 128(1):25–31CrossRefPubMedPubMedCentral Cao Y, Zhang Y, Su Y, Bai J, Wang W, Ge J (2015) Assessment of adaptive rate response provided by accelerometer, minute ventilation and dual sensor compared with normal sinus rhythm during exercise: a self-controlled study in chronotropically competent subjects. Chin Med J 128(1):25–31CrossRefPubMedPubMedCentral
16.
go back to reference Yu CM, Wang L, Chau E, Chan RHW, Kong SL, Tang MO, Christensen J, Stadler RW, Lau CP (2005) Intrathoracic impedance monitoring in patients with heart failure: correlation with fluid status and feasibility of early warning preceding hospitalization. Circulation 112:841–848CrossRefPubMed Yu CM, Wang L, Chau E, Chan RHW, Kong SL, Tang MO, Christensen J, Stadler RW, Lau CP (2005) Intrathoracic impedance monitoring in patients with heart failure: correlation with fluid status and feasibility of early warning preceding hospitalization. Circulation 112:841–848CrossRefPubMed
17.
go back to reference Marzia G, Giuseppe M, Andrea G et al (2017) Severe obstructive sleep apnea: first screening with an implanted pacemaker. Clin Case Rep 5(9):1465–1467 Marzia G, Giuseppe M, Andrea G et al (2017) Severe obstructive sleep apnea: first screening with an implanted pacemaker. Clin Case Rep 5(9):1465–1467
Metadata
Title
Utility of transthoracic impedance and novel algorithm for sleep apnea screening in pacemaker patient
Authors
RuoHan Chen
KePing Chen
Yan Dai
Shu Zhang
Publication date
01-09-2019
Publisher
Springer International Publishing
Published in
Sleep and Breathing / Issue 3/2019
Print ISSN: 1520-9512
Electronic ISSN: 1522-1709
DOI
https://doi.org/10.1007/s11325-018-1755-y

Other articles of this Issue 3/2019

Sleep and Breathing 3/2019 Go to the issue

Sleep Breathing Physiology and Disorders • Letter to the Editors

Response to: The association between retinal thickness variations and restless leg syndrome (RLS)