Skip to main content
Top
Published in: Journal of Clinical Monitoring and Computing 4/2019

01-08-2019 | Original Research

Respiratory measurement using infrared thermography and respiratory volume monitor during sedation in patients undergoing endoscopic urologic procedures under spinal anesthesia

Authors: Jeongmin Kim, Jun Hwan Kwon, Eungjin Kim, Sun Kook Yoo, Cheung-soo Shin

Published in: Journal of Clinical Monitoring and Computing | Issue 4/2019

Login to get access

Abstract

We aimed to evaluate changes in respiratory pattern after sedation by simultaneously applying a respiratory volume monitor (ExSpiron1Xi, RVM) and infrared thermography (IRT) to patients undergoing spinal anesthesia during endoscopic urologic surgeries. After spinal anesthesia was performed, the patient was placed in a lithotomy position for surgery. Then, we established the baseline of the RVM, and started monitoring the mouth and nose with the infrared camera. SpO2 was continuously measured throughout these processes. Once the baseline was set, 0.05 mg/kg midazolam was administered for sedation. Apnea was defined as cessation of airflow for ≥ 10 s with respiratory rate of < 6 breaths/min; hypopnea was defined as a decrease in oxygen hemoglobin of > 4%, compared to baseline. We measured the time at which apnea was detected by IRT, the time at which hypopnea was detected by RVM, and the time at which hypoxia was detected by SpO2. Twenty patients (age: 68.9 ± 11.2 years, body mass index: 24.2 ± 2.6 kg/min2) completed the study. Before sedation, the baseline correlation coefficient of respiratory rate detection between RVM and IRT was 0.866. After midazolam administration, apnea was detected in all subjects within the first 5 min by IRT; the median time required to detect apnea was 102.5 [interquartile range (IQR) 25–75%: 80–155] s. Hypopnea was detected in all subjects within the first 5 min by RVM: the median time required to detect hypopnea was 142.5 (IQR 115–185.2) s. The median time required for SpO2 to decrease > 4% from baseline was 160 (IQR 125–205) s. Our results suggest that IRT can be useful for rapid detection of respiratory changes in patients undergoing sedation following spinal anesthesia for endoscopic urologic procedures.
Literature
1.
go back to reference Miller RD. Miller’s anesthesia. 8th ed. Philadelphia: Elsevier/Saunders; 2015. Miller RD. Miller’s anesthesia. 8th ed. Philadelphia: Elsevier/Saunders; 2015.
5.
go back to reference Bezel R, Russi E, Kronauer H, Mothersill I. Life-threatening apnea after midazolam administration in a patient with obstructive sleep apnea syndrome. Schweiz Med Wochenschr. 1987;117(15):579–83.PubMed Bezel R, Russi E, Kronauer H, Mothersill I. Life-threatening apnea after midazolam administration in a patient with obstructive sleep apnea syndrome. Schweiz Med Wochenschr. 1987;117(15):579–83.PubMed
6.
go back to reference Kiriyama S, Gotoda T, Sano H, Oda I, Nishimoto F, Hirashima T, Kusano C, Kuwano H. Safe and effective sedation in endoscopic submucosal dissection for early gastric cancer: a randomized comparison between propofol continuous infusion and intermittent midazolam injection. J Gastroenterol. 2010;45(8):831–7. https://doi.org/10.1007/s00535-010-0222-8.CrossRefPubMed Kiriyama S, Gotoda T, Sano H, Oda I, Nishimoto F, Hirashima T, Kusano C, Kuwano H. Safe and effective sedation in endoscopic submucosal dissection for early gastric cancer: a randomized comparison between propofol continuous infusion and intermittent midazolam injection. J Gastroenterol. 2010;45(8):831–7. https://​doi.​org/​10.​1007/​s00535-010-0222-8.CrossRefPubMed
7.
go back to reference Beitz A, Riphaus A, Meining A, Kronshage T, Geist C, Wagenpfeil S, Weber A, Jung A, Bajbouj M, Pox C, Schneider G, Schmid RM, Wehrmann T, von Delius S. Capnographic monitoring reduces the incidence of arterial oxygen desaturation and hypoxemia during propofol sedation for colonoscopy: a randomized, controlled study (ColoCap Study). Am J Gastroenterol. 2012;107(8):1205–12. https://doi.org/10.1038/ajg.2012.136.CrossRefPubMed Beitz A, Riphaus A, Meining A, Kronshage T, Geist C, Wagenpfeil S, Weber A, Jung A, Bajbouj M, Pox C, Schneider G, Schmid RM, Wehrmann T, von Delius S. Capnographic monitoring reduces the incidence of arterial oxygen desaturation and hypoxemia during propofol sedation for colonoscopy: a randomized, controlled study (ColoCap Study). Am J Gastroenterol. 2012;107(8):1205–12. https://​doi.​org/​10.​1038/​ajg.​2012.​136.CrossRefPubMed
9.
go back to reference Qadeer MA, Vargo JJ, Dumot JA, Lopez R, Trolli PA, Stevens T, Parsi MA, Sanaka MR, Zuccaro G. Capnographic monitoring of respiratory activity improves safety of sedation for endoscopic cholangiopancreatography and ultrasonography. Gastroenterology. 2009;136(5):1568–76. quiz 819–20.CrossRefPubMed Qadeer MA, Vargo JJ, Dumot JA, Lopez R, Trolli PA, Stevens T, Parsi MA, Sanaka MR, Zuccaro G. Capnographic monitoring of respiratory activity improves safety of sedation for endoscopic cholangiopancreatography and ultrasonography. Gastroenterology. 2009;136(5):1568–76. quiz 819–20.CrossRefPubMed
15.
go back to reference Chekmenev SY, Rara H, Farag AA. Non-contact, wavelet-based measurement of vital signs using thermal imaging. In: Proceedings of the The first international conference on graphics, vision, and image processing (GVIP), Cairo, Egypt, 2005. Chekmenev SY, Rara H, Farag AA. Non-contact, wavelet-based measurement of vital signs using thermal imaging. In: Proceedings of the The first international conference on graphics, vision, and image processing (GVIP), Cairo, Egypt, 2005.
16.
go back to reference Murthy R, Pavlidis I, Tsiamyrtzis P. Touchless Monitoring of Breathing Function. In: Proceedings of the 26th Annual International Conference of the IEEE EMBS. San Francisco, CA, USA, September 1–5, 2004. Murthy R, Pavlidis I, Tsiamyrtzis P. Touchless Monitoring of Breathing Function. In: Proceedings of the 26th Annual International Conference of the IEEE EMBS. San Francisco, CA, USA, September 1–5, 2004.
18.
go back to reference Fei J, Pavlidis I. Virtual Thermistor. In: Proceedings of the 29th Annual International Conference of the IEEE EMBS. Cité Internationale, Lyon, France, August 23–26, 2007. Fei J, Pavlidis I. Virtual Thermistor. In: Proceedings of the 29th Annual International Conference of the IEEE EMBS. Cité Internationale, Lyon, France, August 23–26, 2007.
19.
go back to reference Murthy R, Pavlidis I, Tsiamyrtzis P. Touchless monitoring of breathing function 2004. Murthy R, Pavlidis I, Tsiamyrtzis P. Touchless monitoring of breathing function 2004.
23.
go back to reference Wareham R, Lasenby J, Cameron P, Iles R. Structured light plethysmography (SLP) compared to spirometry: a pilot study. In: Proceedings of the European Respiratory Society Annual Congress, 2009. Wareham R, Lasenby J, Cameron P, Iles R. Structured light plethysmography (SLP) compared to spirometry: a pilot study. In: Proceedings of the European Respiratory Society Annual Congress, 2009.
24.
go back to reference Aoki H, Koshiji K, Nakamura H, Takemura Y, Nakajima M. Study on respiration monitoring method using near-infrared multiple slit-lights projection. In: Proceedings of the Micro-NanoMechatronics and Human Science, 2005 IEEE International Symposium on, 2005. Aoki H, Koshiji K, Nakamura H, Takemura Y, Nakajima M. Study on respiration monitoring method using near-infrared multiple slit-lights projection. In: Proceedings of the Micro-NanoMechatronics and Human Science, 2005 IEEE International Symposium on, 2005.
26.
go back to reference Cala S, Kenyon C, Ferrigno G, Carnevali P, Aliverti A, Pedotti A, Macklem P, Rochester D. Chest wall and lung volume estimation by optical reflectance motion analysis. J Appl Physiol. 1996;81(6):2680–9.CrossRefPubMed Cala S, Kenyon C, Ferrigno G, Carnevali P, Aliverti A, Pedotti A, Macklem P, Rochester D. Chest wall and lung volume estimation by optical reflectance motion analysis. J Appl Physiol. 1996;81(6):2680–9.CrossRefPubMed
30.
go back to reference Bromage PR. Epidural analgesia. Philadelphia: WB Saunders; 1978. Bromage PR. Epidural analgesia. Philadelphia: WB Saunders; 1978.
31.
go back to reference Lucas BD, Kanade T. An iterative image registration technique with an application to stereo vision. 1981. Lucas BD, Kanade T. An iterative image registration technique with an application to stereo vision. 1981.
32.
go back to reference Tomasi C, Kanade T. Detection and tracking of point features. 1991. Tomasi C, Kanade T. Detection and tracking of point features. 1991.
33.
go back to reference Li H, Lu J, Shi G, Zhang Y. Tracking features in retinal images of adaptive optics confocal scanning laser ophthalmoscope using KLT-SIFT algorithm. Biomed Opt Express. 2010;1(1):31–40.CrossRefPubMedPubMedCentral Li H, Lu J, Shi G, Zhang Y. Tracking features in retinal images of adaptive optics confocal scanning laser ophthalmoscope using KLT-SIFT algorithm. Biomed Opt Express. 2010;1(1):31–40.CrossRefPubMedPubMedCentral
35.
go back to reference Al-Najdawi N, Tedmori S, Edirisinghe E, Bez H. An automated real-time people tracking system based on KLT Features Detection. Int Arab J Inf Technol. 2012;9:100–107 Al-Najdawi N, Tedmori S, Edirisinghe E, Bez H. An automated real-time people tracking system based on KLT Features Detection. Int Arab J Inf Technol. 2012;9:100–107
36.
go back to reference Lin G, Tsai T. A face tracking method using feature point tracking. In: Proceedings of the 2012 International Conference on Information Security and Intelligent Control, 14–16 Aug. 2012. Lin G, Tsai T. A face tracking method using feature point tracking. In: Proceedings of the 2012 International Conference on Information Security and Intelligent Control, 14–16 Aug. 2012.
37.
go back to reference Bourel F, Chibelushi CC, Low AA. Robust facial feature tracking. In: Proceedings of the BMVC, 2000. Bourel F, Chibelushi CC, Low AA. Robust facial feature tracking. In: Proceedings of the BMVC, 2000.
38.
go back to reference Adelson EH, Anderson CH, Bergen JR, Burt PJ, Ogden JM. Pyramid methods in image processing. RCA Eng. 1984;29(6):33–41. Adelson EH, Anderson CH, Bergen JR, Burt PJ, Ogden JM. Pyramid methods in image processing. RCA Eng. 1984;29(6):33–41.
39.
go back to reference Kalal Z, Mikolajczyk K, Matas J. Forward-backward error: Automatic detection of tracking failures. In: Proceedings of the Pattern recognition (ICPR), 2010 20th international conference on, 2010. Kalal Z, Mikolajczyk K, Matas J. Forward-backward error: Automatic detection of tracking failures. In: Proceedings of the Pattern recognition (ICPR), 2010 20th international conference on, 2010.
41.
go back to reference Anonymous. Practice guidelines for sedation and analgesia by non-anesthesiologists. Anesthesiology. 2002;96(4):1004–17.CrossRef Anonymous. Practice guidelines for sedation and analgesia by non-anesthesiologists. Anesthesiology. 2002;96(4):1004–17.CrossRef
43.
go back to reference Dini V, Salvo P, Janowska A, Di Francesco F, Barbini A, Romanelli M. Correlation between wound temperature obtained with an infrared camera and clinical wound bed score in venous leg ulcers. Wounds. 2015;27(10):274–8.PubMed Dini V, Salvo P, Janowska A, Di Francesco F, Barbini A, Romanelli M. Correlation between wound temperature obtained with an infrared camera and clinical wound bed score in venous leg ulcers. Wounds. 2015;27(10):274–8.PubMed
Metadata
Title
Respiratory measurement using infrared thermography and respiratory volume monitor during sedation in patients undergoing endoscopic urologic procedures under spinal anesthesia
Authors
Jeongmin Kim
Jun Hwan Kwon
Eungjin Kim
Sun Kook Yoo
Cheung-soo Shin
Publication date
01-08-2019
Publisher
Springer Netherlands
Published in
Journal of Clinical Monitoring and Computing / Issue 4/2019
Print ISSN: 1387-1307
Electronic ISSN: 1573-2614
DOI
https://doi.org/10.1007/s10877-018-0214-4

Other articles of this Issue 4/2019

Journal of Clinical Monitoring and Computing 4/2019 Go to the issue