Continuous noninvasive cardiac output determination using the CNAP system: evaluation of a cardiac output algorithm for the analysis of volume clamp method-derived pulse contour

Authors: Julia Y. Wagner, Julian Grond, Jürgen Fortin, Ileana Negulescu, Miriam Schöfthaler, Bernd Saugel

Published in: Journal of Clinical Monitoring and Computing | Issue 4/2016

Login to get access

Abstract

The CNAP system (CNSystems Medizintechnik AG, Graz, Austria) provides noninvasive continuous arterial pressure measurements by using the volume clamp method. Recently, an algorithm for the determination of cardiac output by pulse contour analysis of the arterial waveform recorded with the CNAP system became available. We evaluated the agreement of the continuous noninvasive cardiac output (CNCO) measurements by CNAP in comparison with cardiac output measurements invasively obtained using transpulmonary thermodilution (TDCO). In this proof-of-concept analysis we studied 38 intensive care unit patients from a previously set up database containing CNAP-derived arterial pressure data and TDCO values obtained with the PiCCO system (Pulsion Medical Systems SE, Feldkirchen, Germany). We applied the new CNCO algorithm retrospectively to the arterial pressure waveforms recorded with CNAP and compared CNCO with the corresponding TDCO values (criterion standard). Analyses were performed separately for (1) CNCO calibrated to the first TDCO (CNCO-cal) and (2) CNCO autocalibrated to biometric patient data (CNCO-auto). We did not perform an analysis of trending capabilities because the patients were hemodynamically stable. The median age and APACHE II score of the 22 male and 16 female patients was 63 years and 18 points, respectively. 18 % were mechanically ventilated and in 29 % vasopressors were administered. Mean ± standard deviation for CNCO-cal, CNCO-auto, and TDCO was 8.1 ± 2.7, 6.4 ± 1.9, and 7.8 ± 2.4 L/min, respectively. For CNCO-cal versus TDCO, Bland–Altman analysis demonstrated a mean difference of +0.2 L/min (standard deviation 1.0 L/min; 95 % limits of agreement −1.7 to +2.2 L/min, percentage error 25 %). For CNCO-auto versus TDCO, the mean difference was −1.4 L/min (standard deviation 1.8 L/min; 95 % limits of agreement −4.9 to +2.1 L/min, percentage error 45 %). This pilot analysis shows that CNCO determination is feasible in critically ill patients. A percentage error of 25 % indicates acceptable agreement between CNCO-cal and TDCO. The mean difference, the standard deviation, and the percentage error between CNCO-auto and TDCO were higher than between CNCO-cal and TDCO. A hyperdynamic cardiocirculatory state in a substantial number of patients and the hemodynamic stability making trending analysis impossible are main limitations of our study.
Literature
1.
go back to reference Fortin J, Marte W, Grullenberger R, Hacker A, Habenbacher W, Heller A, Wagner C, Wach P, Skrabal F. Continuous non-invasive blood pressure monitoring using concentrically interlocking control loops. Comput Biol Med. 2006;36:941–57.CrossRefPubMed Fortin J, Marte W, Grullenberger R, Hacker A, Habenbacher W, Heller A, Wagner C, Wach P, Skrabal F. Continuous non-invasive blood pressure monitoring using concentrically interlocking control loops. Comput Biol Med. 2006;36:941–57.CrossRefPubMed
2.
go back to reference Saugel B, Dueck R, Wagner JY. Measurement of blood pressure. Best Pract Res Clin Anaesthesiol. 2014;28:309–22.CrossRefPubMed Saugel B, Dueck R, Wagner JY. Measurement of blood pressure. Best Pract Res Clin Anaesthesiol. 2014;28:309–22.CrossRefPubMed
3.
go back to reference Penaz J. Current photoelectric recording of blood flow through the finger. Cesk Fysiol. 1975;24:349–52.PubMed Penaz J. Current photoelectric recording of blood flow through the finger. Cesk Fysiol. 1975;24:349–52.PubMed
4.
go back to reference Fortin J, Wellisch A, Maier K. CNAP—evolution of continuous non-invasive arterial blood pressure monitoring. Biomed Tech. 2013;. doi:10.1515/bmt-2013-4179 (Berl). Fortin J, Wellisch A, Maier K. CNAP—evolution of continuous non-invasive arterial blood pressure monitoring. Biomed Tech. 2013;. doi:10.​1515/​bmt-2013-4179 (Berl).
5.
go back to reference Jeleazcov C, Krajinovic L, Munster T, Birkholz T, Fried R, Schuttler J, Fechner J. Precision and accuracy of a new device (CNAPTM) for continuous non-invasive arterial pressure monitoring: assessment during general anaesthesia. Br J Anaesth. 2010;105:264–72.CrossRefPubMed Jeleazcov C, Krajinovic L, Munster T, Birkholz T, Fried R, Schuttler J, Fechner J. Precision and accuracy of a new device (CNAPTM) for continuous non-invasive arterial pressure monitoring: assessment during general anaesthesia. Br J Anaesth. 2010;105:264–72.CrossRefPubMed
6.
go back to reference Ilies C, Bauer M, Berg P, Rosenberg J, Hedderich J, Bein B, Hinz J, Hanss R. Investigation of the agreement of a continuous non-invasive arterial pressure device in comparison with invasive radial artery measurement. Br J Anaesth. 2012;108:202–10.CrossRefPubMed Ilies C, Bauer M, Berg P, Rosenberg J, Hedderich J, Bein B, Hinz J, Hanss R. Investigation of the agreement of a continuous non-invasive arterial pressure device in comparison with invasive radial artery measurement. Br J Anaesth. 2012;108:202–10.CrossRefPubMed
7.
go back to reference Kumar GA, Jagadeesh AM, Singh NG, Prasad SR. Evaluation of continuous non-invasive arterial pressure monitoring during induction of general anaesthesia in patients undergoing cardiac surgery. Indian J Anaesth. 2015;59:21–5.CrossRefPubMedPubMedCentral Kumar GA, Jagadeesh AM, Singh NG, Prasad SR. Evaluation of continuous non-invasive arterial pressure monitoring during induction of general anaesthesia in patients undergoing cardiac surgery. Indian J Anaesth. 2015;59:21–5.CrossRefPubMedPubMedCentral
8.
go back to reference Wagner JY, Negulescu I, Schofthaler M, Hapfelmeier A, Meidert AS, Huber W, Schmid RM, Saugel B. Continuous noninvasive arterial pressure measurement using the volume clamp method: an evaluation of the CNAP device in intensive care unit patients. J Clin Monit Comput. 2015;. doi:10.1007/s10877-015-9670-2. Wagner JY, Negulescu I, Schofthaler M, Hapfelmeier A, Meidert AS, Huber W, Schmid RM, Saugel B. Continuous noninvasive arterial pressure measurement using the volume clamp method: an evaluation of the CNAP device in intensive care unit patients. J Clin Monit Comput. 2015;. doi:10.​1007/​s10877-015-9670-2.
9.
go back to reference Jagadeesh AM, Singh NG, Mahankali S. A comparison of a continuous noninvasive arterial pressure (CNAP) monitor with an invasive arterial blood pressure monitor in the cardiac surgical ICU. Ann Card Anaesth. 2012;15:180–4.CrossRefPubMed Jagadeesh AM, Singh NG, Mahankali S. A comparison of a continuous noninvasive arterial pressure (CNAP) monitor with an invasive arterial blood pressure monitor in the cardiac surgical ICU. Ann Card Anaesth. 2012;15:180–4.CrossRefPubMed
10.
go back to reference Wagner JY, Prantner JS, Meidert AS, Hapfelmeier A, Schmid RM, Saugel B. Noninvasive continuous versus intermittent arterial pressure monitoring: evaluation of the vascular unloading technique (CNAP device) in the emergency department. Scand J Trauma Resusc Emerg Med. 2014;22:8.CrossRefPubMedPubMedCentral Wagner JY, Prantner JS, Meidert AS, Hapfelmeier A, Schmid RM, Saugel B. Noninvasive continuous versus intermittent arterial pressure monitoring: evaluation of the vascular unloading technique (CNAP device) in the emergency department. Scand J Trauma Resusc Emerg Med. 2014;22:8.CrossRefPubMedPubMedCentral
11.
go back to reference Saugel B, Kirsche SV, Hapfelmeier A, Phillip V, Schultheiss C, Schmid RM, Huber W. Prediction of fluid responsiveness in patients admitted to the medical intensive care unit. J Crit Care. 2013;28(537):e531–9. Saugel B, Kirsche SV, Hapfelmeier A, Phillip V, Schultheiss C, Schmid RM, Huber W. Prediction of fluid responsiveness in patients admitted to the medical intensive care unit. J Crit Care. 2013;28(537):e531–9.
12.
go back to reference Saugel B, Phillip V, Gaa J, Berger H, Lersch C, Schultheiss C, Thies P, Schneider H, Hollthaler J, Herrmann A, Schmid RM, Huber W. Advanced hemodynamic monitoring before and after transjugular intrahepatic portosystemic shunt: implications for selection of patients—a prospective study. Radiology. 2012;262:343–52.CrossRefPubMed Saugel B, Phillip V, Gaa J, Berger H, Lersch C, Schultheiss C, Thies P, Schneider H, Hollthaler J, Herrmann A, Schmid RM, Huber W. Advanced hemodynamic monitoring before and after transjugular intrahepatic portosystemic shunt: implications for selection of patients—a prospective study. Radiology. 2012;262:343–52.CrossRefPubMed
13.
go back to reference Bland JM, Altman DG. Agreement between methods of measurement with multiple observations per individual. J Biopharm Stat. 2007;17:571–82.CrossRefPubMed Bland JM, Altman DG. Agreement between methods of measurement with multiple observations per individual. J Biopharm Stat. 2007;17:571–82.CrossRefPubMed
14.
go back to reference Critchley LA, Critchley JA. A meta-analysis of studies using bias and precision statistics to compare cardiac output measurement techniques. J Clin Monit Comput. 1999;15:85–91.CrossRefPubMed Critchley LA, Critchley JA. A meta-analysis of studies using bias and precision statistics to compare cardiac output measurement techniques. J Clin Monit Comput. 1999;15:85–91.CrossRefPubMed
15.
go back to reference Marik PE. Noninvasive cardiac output monitors: a state-of the-art review. J Cardiothorac Vasc Anesth. 2013;27:121–34.CrossRefPubMed Marik PE. Noninvasive cardiac output monitors: a state-of the-art review. J Cardiothorac Vasc Anesth. 2013;27:121–34.CrossRefPubMed
17.
go back to reference Saugel B, Cecconi M, Wagner JY, Reuter DA. Noninvasive continuous cardiac output monitoring in perioperative and intensive care medicine. Br J Anaesth. 2014;114:562–75.CrossRef Saugel B, Cecconi M, Wagner JY, Reuter DA. Noninvasive continuous cardiac output monitoring in perioperative and intensive care medicine. Br J Anaesth. 2014;114:562–75.CrossRef
19.
go back to reference Wagner JY, Saugel B. When should we adopt continuous noninvasive hemodynamic monitoring technologies into clinical routine? J Clin Monit Comput. 2014;29:1–3.CrossRef Wagner JY, Saugel B. When should we adopt continuous noninvasive hemodynamic monitoring technologies into clinical routine? J Clin Monit Comput. 2014;29:1–3.CrossRef
20.
go back to reference Peyton PJ, Chong SW. Minimally invasive measurement of cardiac output during surgery and critical care: a meta-analysis of accuracy and precision. Anesthesiology. 2010;113:1220–35.CrossRefPubMed Peyton PJ, Chong SW. Minimally invasive measurement of cardiac output during surgery and critical care: a meta-analysis of accuracy and precision. Anesthesiology. 2010;113:1220–35.CrossRefPubMed
21.
go back to reference Saugel B, Reuter DA. Are we ready for the age of non-invasive haemodynamic monitoring? Br J Anaesth. 2014;113:340–3.CrossRefPubMed Saugel B, Reuter DA. Are we ready for the age of non-invasive haemodynamic monitoring? Br J Anaesth. 2014;113:340–3.CrossRefPubMed
22.
go back to reference Broch O, Renner J, Gruenewald M, Meybohm P, Schottler J, Caliebe A, Steinfath M, Malbrain M, Bein B. A comparison of the Nexfin(R) and transcardiopulmonary thermodilution to estimate cardiac output during coronary artery surgery. Anaesthesia. 2012;67:377–83.CrossRefPubMed Broch O, Renner J, Gruenewald M, Meybohm P, Schottler J, Caliebe A, Steinfath M, Malbrain M, Bein B. A comparison of the Nexfin(R) and transcardiopulmonary thermodilution to estimate cardiac output during coronary artery surgery. Anaesthesia. 2012;67:377–83.CrossRefPubMed
23.
go back to reference Fischer MO, Avram R, Carjaliu I, Massetti M, Gerard JL, Hanouz JL, Fellahi JL. Non-invasive continuous arterial pressure and cardiac index monitoring with Nexfin after cardiac surgery. Br J Anaesth. 2012;109:514–21.CrossRefPubMed Fischer MO, Avram R, Carjaliu I, Massetti M, Gerard JL, Hanouz JL, Fellahi JL. Non-invasive continuous arterial pressure and cardiac index monitoring with Nexfin after cardiac surgery. Br J Anaesth. 2012;109:514–21.CrossRefPubMed
24.
go back to reference Fischer MO, Coucoravas J, Truong J, Zhu L, Gerard JL, Hanouz JL, Fellahi JL. Assessment of changes in cardiac index and fluid responsiveness: a comparison of Nexfin and transpulmonary thermodilution. Acta Anaesthesiol Scand. 2013;57:704–12.CrossRefPubMed Fischer MO, Coucoravas J, Truong J, Zhu L, Gerard JL, Hanouz JL, Fellahi JL. Assessment of changes in cardiac index and fluid responsiveness: a comparison of Nexfin and transpulmonary thermodilution. Acta Anaesthesiol Scand. 2013;57:704–12.CrossRefPubMed
25.
go back to reference Hofhuizen C, Lansdorp B, van der Hoeven JG, Scheffer GJ, Lemson J. Validation of noninvasive pulse contour cardiac output using finger arterial pressure in cardiac surgery patients requiring fluid therapy. J Crit Care. 2014;29:161–5.CrossRefPubMed Hofhuizen C, Lansdorp B, van der Hoeven JG, Scheffer GJ, Lemson J. Validation of noninvasive pulse contour cardiac output using finger arterial pressure in cardiac surgery patients requiring fluid therapy. J Crit Care. 2014;29:161–5.CrossRefPubMed
26.
go back to reference Bubenek-Turconi SI, Craciun M, Miclea I, Perel A. Noninvasive continuous cardiac output by the Nexfin before and after preload-modifying maneuvers: a comparison with intermittent thermodilution cardiac output. Anesth Analg. 2013;117:366–72.CrossRefPubMed Bubenek-Turconi SI, Craciun M, Miclea I, Perel A. Noninvasive continuous cardiac output by the Nexfin before and after preload-modifying maneuvers: a comparison with intermittent thermodilution cardiac output. Anesth Analg. 2013;117:366–72.CrossRefPubMed
27.
go back to reference Ameloot K, Van De Vijver K, Broch O, Van Regenmortel N, De Laet I, Schoonheydt K, Dits H, Bein B, Malbrain ML. Nexfin noninvasive continuous hemodynamic monitoring: validation against continuous pulse contour and intermittent transpulmonary thermodilution derived cardiac output in critically ill patients. Scientific World J. 2013;2013:519080.CrossRef Ameloot K, Van De Vijver K, Broch O, Van Regenmortel N, De Laet I, Schoonheydt K, Dits H, Bein B, Malbrain ML. Nexfin noninvasive continuous hemodynamic monitoring: validation against continuous pulse contour and intermittent transpulmonary thermodilution derived cardiac output in critically ill patients. Scientific World J. 2013;2013:519080.CrossRef
28.
go back to reference Monnet X, Picard F, Lidzborski E, Mesnil M, Duranteau J, Richard C, Teboul JL. The estimation of cardiac output by the Nexfin device is of poor reliability for tracking the effects of a fluid challenge. Crit Care. 2012;16:R212.CrossRefPubMedPubMedCentral Monnet X, Picard F, Lidzborski E, Mesnil M, Duranteau J, Richard C, Teboul JL. The estimation of cardiac output by the Nexfin device is of poor reliability for tracking the effects of a fluid challenge. Crit Care. 2012;16:R212.CrossRefPubMedPubMedCentral
Metadata
Title
Continuous noninvasive cardiac output determination using the CNAP system: evaluation of a cardiac output algorithm for the analysis of volume clamp method-derived pulse contour
Authors
Julia Y. Wagner
Julian Grond
Jürgen Fortin
Ileana Negulescu
Miriam Schöfthaler
Bernd Saugel
Publication date
01-08-2016
Publisher
Springer Netherlands
Published in
Journal of Clinical Monitoring and Computing / Issue 4/2016
Print ISSN: 1387-1307
Electronic ISSN: 1573-2614
DOI
https://doi.org/10.1007/s10877-015-9744-1

Other articles of this Issue 4/2016

Journal of Clinical Monitoring and Computing 4/2016 Go to the issue