Skip to main content
Top
Published in: Journal of Interventional Cardiac Electrophysiology 3/2021

01-04-2021 | Sudden Cardiac Death

Defibrillation threshold testing during implantable cardioverter defibrillator implantation: 5-year follow-up

Authors: Sung Soo Kim, Hyung Wook Park, Hyung Ki Jeong, Ki Hong Lee, Nam Sik Yoon, Jeong Gwan Cho

Published in: Journal of Interventional Cardiac Electrophysiology | Issue 3/2021

Login to get access

Abstract

Purpose

Defibrillation threshold (DFT) testing is a routine practice in some Asian countries for patients receiving an implantable cardioverter defibrillator (ICD). However, there are few long-term data about the necessity of intraoperative DFT testing in an Asian population. We investigated the safety of DFT testing and the long-term clinical outcomes in Asian patients undergoing ICD implantation.

Methods

All patients undergoing de novo transvenous ICD implantation were randomized to undergo periprocedural DFT testing. The study included 67 patients (50 males; 51.5 ± 16.9 years) who underwent ICD implantation with (n = 33) or without (n = 34) intraoperative DFT testing between March 2012 and February 2014. We compared first-shock success, composite safety end points (the sum of complications recorded at 30 days), arrhythmic death, and all-cause mortality.

Results

The baseline clinical characteristics and the procedural-related adverse event rate (3.0% with DFT vs. 0% with non-DFT, p = 0.214) did not differ between groups. The programmed output of the first shock was lower in the DFT testing group (22.9 ± 4.4 J vs. 25.3 ± 5.4 J, p = 0.007). However, there were no significant differences between groups for all-cause mortality (12.1% vs. 17.6%, p = 0.526) or first-shock success rate for ventricular arrhythmia (100% vs. 88.2%, p = 0.471).

Conclusions

There were no between-group differences in periprocedural safety, complications, and long-term clinical outcomes. Our results suggest that DFT testing in Asian patients allows reduction of the programmed output of the first shock, but does not affect long-term clinical outcomes.
Literature
1.
go back to reference Moss AJ, Hall WJ, Cannom DS, Daubert JP, Higgins SL, Klein H, et al. Improved survival with an implanted defibrillator in patients with coronary disease at high risk for ventricular arrhythmia. Multicenter Automatic Defibrillator Implantation Trial Investigators. N Engl J Med. 1996;335:1933–40.CrossRef Moss AJ, Hall WJ, Cannom DS, Daubert JP, Higgins SL, Klein H, et al. Improved survival with an implanted defibrillator in patients with coronary disease at high risk for ventricular arrhythmia. Multicenter Automatic Defibrillator Implantation Trial Investigators. N Engl J Med. 1996;335:1933–40.CrossRef
2.
go back to reference The antiarrhythmics versus implantable defibrillators (AVID) investigators. A comparison of antiarrhythmic-drug therapy with implantable defibrillators in patients resuscitated from near-fatal ventricular arrhythmias. N Engl J Med. 1997;337:1576–83.CrossRef The antiarrhythmics versus implantable defibrillators (AVID) investigators. A comparison of antiarrhythmic-drug therapy with implantable defibrillators in patients resuscitated from near-fatal ventricular arrhythmias. N Engl J Med. 1997;337:1576–83.CrossRef
3.
go back to reference Moss AJ, Zareba W, Hall WJ, Klein H, Wilber DJ, Cannom DS, et al. Prophylactic implantation of a defibrillator in patients with myocardial infarction and reduced ejection fraction. N Engl J Med. 2002;346:877–83.CrossRef Moss AJ, Zareba W, Hall WJ, Klein H, Wilber DJ, Cannom DS, et al. Prophylactic implantation of a defibrillator in patients with myocardial infarction and reduced ejection fraction. N Engl J Med. 2002;346:877–83.CrossRef
4.
go back to reference Winkle RA, Stinson EB, Bach SM Jr, Echt DS, Oyer P, Armstrong K. Measurement of cardioversion/defibrillation thresholds in man by a truncated exponential waveform and an apical patch-superior vena caval spring electrode configuration. Circulation. 1984;69:766–71.CrossRef Winkle RA, Stinson EB, Bach SM Jr, Echt DS, Oyer P, Armstrong K. Measurement of cardioversion/defibrillation thresholds in man by a truncated exponential waveform and an apical patch-superior vena caval spring electrode configuration. Circulation. 1984;69:766–71.CrossRef
5.
go back to reference Singer I, Lang D. Defibrillation threshold: clinical utility and therapeutic implications. Pacing Clin Electrophysiol. 1992;15:932–49.CrossRef Singer I, Lang D. Defibrillation threshold: clinical utility and therapeutic implications. Pacing Clin Electrophysiol. 1992;15:932–49.CrossRef
6.
go back to reference Marchlinski FE, Flores B, Miller JM, Gottlieb CD, Hargrove WC 3rd. Relation of the intraoperative defibrillation threshold to successful postoperative defibrillation with an automatic implantable cardioverter defibrillator. Am J Cardiol. 1988;62:393–8.CrossRef Marchlinski FE, Flores B, Miller JM, Gottlieb CD, Hargrove WC 3rd. Relation of the intraoperative defibrillation threshold to successful postoperative defibrillation with an automatic implantable cardioverter defibrillator. Am J Cardiol. 1988;62:393–8.CrossRef
7.
go back to reference Tokano T, Bach D, Chang J, Davis J, Souza JJ, Zivin A, et al. Effect of ventricular shock strength on cardiac hemodynamics. J Cardiovasc Electrophysiol. 1998;9:791–7.CrossRef Tokano T, Bach D, Chang J, Davis J, Souza JJ, Zivin A, et al. Effect of ventricular shock strength on cardiac hemodynamics. J Cardiovasc Electrophysiol. 1998;9:791–7.CrossRef
8.
go back to reference Runsio M, Bergfeldt L, Brodin LA, Ribeiro A, Samuelsson S, Rosenqvist M. Left ventricular function after repeated episodes of ventricular fibrillation and defibrillation assessed by transoesophageal echocardiography. Eur Heart J. 1997;18:124–31.CrossRef Runsio M, Bergfeldt L, Brodin LA, Ribeiro A, Samuelsson S, Rosenqvist M. Left ventricular function after repeated episodes of ventricular fibrillation and defibrillation assessed by transoesophageal echocardiography. Eur Heart J. 1997;18:124–31.CrossRef
9.
go back to reference Birnie D, Tung S, Simpson C, Crystal E, Exner D, Ayala Paredes FA, et al. Complications associated with defibrillation threshold testing: the Canadian experience. Heart Rhythm. 2008;5:387–90.CrossRef Birnie D, Tung S, Simpson C, Crystal E, Exner D, Ayala Paredes FA, et al. Complications associated with defibrillation threshold testing: the Canadian experience. Heart Rhythm. 2008;5:387–90.CrossRef
10.
go back to reference Roh SY, Choi JI, Kim MS, Cho EY, Kim YG, Lee KN, et al. Trends in the use of implantable cardioverter-defibrillators for prevention of sudden cardiac arrest: a South Korean nationwide population-based study. Pacing Clin Electrophysiol. 2019;42:1086–94.CrossRef Roh SY, Choi JI, Kim MS, Cho EY, Kim YG, Lee KN, et al. Trends in the use of implantable cardioverter-defibrillators for prevention of sudden cardiac arrest: a South Korean nationwide population-based study. Pacing Clin Electrophysiol. 2019;42:1086–94.CrossRef
11.
go back to reference Ellenbogen KA, Wood MA, Stambler BS, Welch WJ, Damiano RJ. Measurement of ventricular electrogram amplitude during intraoperative induction of ventricular tachyarrhythmias. Am J Cardiol. 1992;70:1017–22.CrossRef Ellenbogen KA, Wood MA, Stambler BS, Welch WJ, Damiano RJ. Measurement of ventricular electrogram amplitude during intraoperative induction of ventricular tachyarrhythmias. Am J Cardiol. 1992;70:1017–22.CrossRef
12.
go back to reference Swerdlow CD. Implantation of cardioverter defibrillators without induction of ventricular fibrillation. Circulation. 2001;103:2159–64.CrossRef Swerdlow CD. Implantation of cardioverter defibrillators without induction of ventricular fibrillation. Circulation. 2001;103:2159–64.CrossRef
13.
go back to reference Wilkoff BL, Fauchier L, Stiles MK, Morillo CA, Al-Khatib SM, Almendral J, et al. 2015 HRS/EHRA/APHRS/SOLAECE expert consensus statement on optimal implantable cardioverter-defibrillator programming and testing. Heart Rhythm. 2016;13:e50–86.CrossRef Wilkoff BL, Fauchier L, Stiles MK, Morillo CA, Al-Khatib SM, Almendral J, et al. 2015 HRS/EHRA/APHRS/SOLAECE expert consensus statement on optimal implantable cardioverter-defibrillator programming and testing. Heart Rhythm. 2016;13:e50–86.CrossRef
14.
go back to reference Healey JS, Dorian P, Mitchell LB, Talajic M, Philippon F, Simpson C, et al. Canadian Registry of ICD Implant Testing procedures (CREDIT): current practice, risks, and costs of intraoperative defibrillation testing. J Cardiovasc Electrophysiol. 2010;21:177–82.CrossRef Healey JS, Dorian P, Mitchell LB, Talajic M, Philippon F, Simpson C, et al. Canadian Registry of ICD Implant Testing procedures (CREDIT): current practice, risks, and costs of intraoperative defibrillation testing. J Cardiovasc Electrophysiol. 2010;21:177–82.CrossRef
15.
go back to reference Lin EF, Dalal D, Cheng A, Marine JE, Nazarian S, Sinha S, et al. Predictors of high defibrillation threshold in the modern era. Pacing Clin Electrophysiol. 2013;36:231–7.CrossRef Lin EF, Dalal D, Cheng A, Marine JE, Nazarian S, Sinha S, et al. Predictors of high defibrillation threshold in the modern era. Pacing Clin Electrophysiol. 2013;36:231–7.CrossRef
16.
go back to reference Bansch D, Bonnemeier H, Brandt J, Bode F, Svendsen JH, Taborsky M, et al. Intra-operative defibrillation testing and clinical shock efficacy in patients with implantable cardioverter-defibrillators: the NORDIC ICD randomized clinical trial. Eur Heart J. 2015;36:2500–7.CrossRef Bansch D, Bonnemeier H, Brandt J, Bode F, Svendsen JH, Taborsky M, et al. Intra-operative defibrillation testing and clinical shock efficacy in patients with implantable cardioverter-defibrillators: the NORDIC ICD randomized clinical trial. Eur Heart J. 2015;36:2500–7.CrossRef
17.
go back to reference Hinkle LE Jr, Thaler HT. Clinical classification of cardiac deaths. Circulation. 1982;65:457–64.CrossRef Hinkle LE Jr, Thaler HT. Clinical classification of cardiac deaths. Circulation. 1982;65:457–64.CrossRef
18.
go back to reference Healey JS, Hohnloser SH, Glikson M, Neuzner J, Mabo P, Vinolas X, et al. Cardioverter defibrillator implantation without induction of ventricular fibrillation: a single-blind, non-inferiority, randomised controlled trial (SIMPLE). Lancet. 2015;385:785–91.CrossRef Healey JS, Hohnloser SH, Glikson M, Neuzner J, Mabo P, Vinolas X, et al. Cardioverter defibrillator implantation without induction of ventricular fibrillation: a single-blind, non-inferiority, randomised controlled trial (SIMPLE). Lancet. 2015;385:785–91.CrossRef
19.
go back to reference Nagai T, Kurita T, Satomi K, Noda T, Okamura H, Shimizu W, et al. QRS prolongation is associated with high defibrillation thresholds during cardioverter-defibrillator implantations in patients with hypertrophic cardiomyopathy. Circ J. 2009;73:1028–32.CrossRef Nagai T, Kurita T, Satomi K, Noda T, Okamura H, Shimizu W, et al. QRS prolongation is associated with high defibrillation thresholds during cardioverter-defibrillator implantations in patients with hypertrophic cardiomyopathy. Circ J. 2009;73:1028–32.CrossRef
20.
go back to reference Mizukami K, Yokoshiki H, Mitsuyama H, Watanabe M, Tenma T, Matsui Y, et al. Predictors of high defibrillation threshold in patients with implantable cardioverter-defibillator using a transvenous dual-coil lead. Circ J. 2015;79:77–84.CrossRef Mizukami K, Yokoshiki H, Mitsuyama H, Watanabe M, Tenma T, Matsui Y, et al. Predictors of high defibrillation threshold in patients with implantable cardioverter-defibillator using a transvenous dual-coil lead. Circ J. 2015;79:77–84.CrossRef
21.
go back to reference Connolly SJ, Hallstrom AP, Cappato R, Schron EB, Kuck KH, Zipes DP, et al. Meta-analysis of the implantable cardioverter defibrillator secondary prevention trials. AVID, CASH and CIDS studies. Antiarrhythmics vs Implantable Defibrillator study. Cardiac Arrest Study Hamburg . Canadian Implantable Defibrillator Study. Eur Heart J. 2000;21:2071–8.CrossRef Connolly SJ, Hallstrom AP, Cappato R, Schron EB, Kuck KH, Zipes DP, et al. Meta-analysis of the implantable cardioverter defibrillator secondary prevention trials. AVID, CASH and CIDS studies. Antiarrhythmics vs Implantable Defibrillator study. Cardiac Arrest Study Hamburg . Canadian Implantable Defibrillator Study. Eur Heart J. 2000;21:2071–8.CrossRef
22.
go back to reference Crossley GH, Boyce K, Roelke M, Evans J, Yousuf D, Syed Z, et al. A prospective randomized trial of defibrillation thresholds from the right ventricular outflow tract and the right ventricular apex. Pacing Clin Electrophysiol. 2009;32:166–71.CrossRef Crossley GH, Boyce K, Roelke M, Evans J, Yousuf D, Syed Z, et al. A prospective randomized trial of defibrillation thresholds from the right ventricular outflow tract and the right ventricular apex. Pacing Clin Electrophysiol. 2009;32:166–71.CrossRef
23.
go back to reference Blatt JA, Poole JE, Johnson GW, Callans DJ, Raitt MH, Reddy RK, et al. No benefit from defibrillation threshold testing in the SCD-HeFT (Sudden Cardiac Death in Heart Failure Trial). J Am Coll Cardiol. 2008;52:551–6.CrossRef Blatt JA, Poole JE, Johnson GW, Callans DJ, Raitt MH, Reddy RK, et al. No benefit from defibrillation threshold testing in the SCD-HeFT (Sudden Cardiac Death in Heart Failure Trial). J Am Coll Cardiol. 2008;52:551–6.CrossRef
24.
go back to reference Brignole M, Occhetta E, Bongiorni MG, Proclemer A, Favale S, Iacopino S, et al. Clinical evaluation of defibrillation testing in an unselected population of 2,120 consecutive patients undergoing first implantable cardioverter-defibrillator implant. J Am Coll Cardiol. 2012;60:981–7.CrossRef Brignole M, Occhetta E, Bongiorni MG, Proclemer A, Favale S, Iacopino S, et al. Clinical evaluation of defibrillation testing in an unselected population of 2,120 consecutive patients undergoing first implantable cardioverter-defibrillator implant. J Am Coll Cardiol. 2012;60:981–7.CrossRef
26.
go back to reference Murakoshi N, Aonuma K. Epidemiology of arrhythmias and sudden cardiac death in Asia. Circ J. 2013;77:2419–31.CrossRef Murakoshi N, Aonuma K. Epidemiology of arrhythmias and sudden cardiac death in Asia. Circ J. 2013;77:2419–31.CrossRef
27.
go back to reference Russo AM, Chung MK. Is defibrillation testing necessary for implantable transvenous defibrillators?: defibrillation testing is necessary at the time of implantable cardioverter defibrillator implantation. Circ Arrhythm Electrophysiol. 2014;7:337–46.CrossRef Russo AM, Chung MK. Is defibrillation testing necessary for implantable transvenous defibrillators?: defibrillation testing is necessary at the time of implantable cardioverter defibrillator implantation. Circ Arrhythm Electrophysiol. 2014;7:337–46.CrossRef
28.
go back to reference Gold MR, Higgins S, Klein R, Gilliam FR, Kopelman H, Hessen S, et al. Efficacy and temporal stability of reduced safety margins for ventricular defibrillation: primary results from the Low Energy Safety Study (LESS). Circulation. 2002;105:2043–8.CrossRef Gold MR, Higgins S, Klein R, Gilliam FR, Kopelman H, Hessen S, et al. Efficacy and temporal stability of reduced safety margins for ventricular defibrillation: primary results from the Low Energy Safety Study (LESS). Circulation. 2002;105:2043–8.CrossRef
29.
go back to reference Wathen MS, DeGroot PJ, Sweeney MO, Stark AJ, Otterness MF, Adkisson WO, et al. Prospective randomized multicenter trial of empirical antitachycardia pacing versus shocks for spontaneous rapid ventricular tachycardia in patients with implantable cardioverter-defibrillators: Pacing Fast Ventricular Tachycardia Reduces Shock Therapies (PainFREE Rx II) trial results. Circulation. 2004;110:2591–6.CrossRef Wathen MS, DeGroot PJ, Sweeney MO, Stark AJ, Otterness MF, Adkisson WO, et al. Prospective randomized multicenter trial of empirical antitachycardia pacing versus shocks for spontaneous rapid ventricular tachycardia in patients with implantable cardioverter-defibrillators: Pacing Fast Ventricular Tachycardia Reduces Shock Therapies (PainFREE Rx II) trial results. Circulation. 2004;110:2591–6.CrossRef
30.
go back to reference Pires LA, Johnson KM. Intraoperative testing of the implantable cardioverter-defibrillator: how much is enough? J Cardiovasc Electrophysiol. 2006;17:140–5.CrossRef Pires LA, Johnson KM. Intraoperative testing of the implantable cardioverter-defibrillator: how much is enough? J Cardiovasc Electrophysiol. 2006;17:140–5.CrossRef
31.
go back to reference Russo AM, Sauer W, Gerstenfeld EP, Hsia HH, Lin D, Cooper JM, et al. Defibrillation threshold testing: is it really necessary at the time of implantable cardioverter-defibrillator insertion? Heart Rhythm. 2005;2:456–61.CrossRef Russo AM, Sauer W, Gerstenfeld EP, Hsia HH, Lin D, Cooper JM, et al. Defibrillation threshold testing: is it really necessary at the time of implantable cardioverter-defibrillator insertion? Heart Rhythm. 2005;2:456–61.CrossRef
32.
go back to reference Radbill AE, Triedman JK, Berul CI, Walsh EP, Alexander ME, Webster G, et al. Prospective evaluation of defibrillation threshold and postshock rhythm in young ICD recipients. Pacing Clin Electrophysiol. 2012;35:1487–93.CrossRef Radbill AE, Triedman JK, Berul CI, Walsh EP, Alexander ME, Webster G, et al. Prospective evaluation of defibrillation threshold and postshock rhythm in young ICD recipients. Pacing Clin Electrophysiol. 2012;35:1487–93.CrossRef
Metadata
Title
Defibrillation threshold testing during implantable cardioverter defibrillator implantation: 5-year follow-up
Authors
Sung Soo Kim
Hyung Wook Park
Hyung Ki Jeong
Ki Hong Lee
Nam Sik Yoon
Jeong Gwan Cho
Publication date
01-04-2021

Other articles of this Issue 3/2021