Skip to main content
Top
Published in: Journal of Interventional Cardiac Electrophysiology 2/2020

01-11-2020 | Atrial Fibrillation

Temperature drop in thawing phase reflects sufficient ice formation and better outcome of pulmonary vein isolation using second-generation cryoballoon

Authors: Takashi Kaneshiro, Naoko Hijioka, Yoshiyuki Matsumoto, Minoru Nodera, Shinya Yamada, Masashi Kamioka, Yasuchika Takeishi

Published in: Journal of Interventional Cardiac Electrophysiology | Issue 2/2020

Login to get access

Abstract

Background

Few reports exist regarding the details of ice formation on second-generation cryoballoon (CB) surface during pulmonary vein isolation (PVI). We propose a new parameter “temperature drop” in thawing phase for predicting sufficient ice formation and CB-PVI outcome.

Methods

Consecutive 106 patients who underwent successful CB-PVI for atrial fibrillation (AF) were analyzed. We defined “temperature drop” as a temperature drop of more than 3 °C just after CB catheter bending. We compared the previously known parameters predicting durable PVI between PVs with or without temperature drop. Then, we compared the PVI outcome among three groups: group 1 with temperature drop in all PVs, group 2 with temperature drop in 1–3 PVs, and group 3 without temperature drop in any PV.

Results

Temperature drop was present in 206 out of 424 isolated PVs. In those, PV occlusion score was significantly higher (3.7 ± 0.5 vs. 3.5 ± 0.6, P <0.001), and thawing time was significantly longer (55 ± 20 vs. 46 ± 21 s, P < 0.001) in PVs with temperature drop than those without. With a mean follow up period of 376 ± 217 days, Kaplan-Meier survival analysis revealed that no patients in group 1 experienced AF recurrence, 14 out of 86 patients (16%) experienced AF recurrence in group 2, and 5 out of 10 (50%) patients experienced AF recurrence in group 3 (Log-Rank P = 0.003).

Conclusion

The temperature drop in thawing phase might reflect the state of ice formation and can be used to predict clinical outcome after CB-PVI.
Literature
1.
go back to reference Haïssaguerre M, Jaïs P, Shah DC, Takahashi A, Hocini M, Quiniou G, et al. Spontaneous initiation of atrial fibrillation by ectopic beats originating in the pulmonary veins. N Engl J Med. 1998;339:659–66.CrossRefPubMed Haïssaguerre M, Jaïs P, Shah DC, Takahashi A, Hocini M, Quiniou G, et al. Spontaneous initiation of atrial fibrillation by ectopic beats originating in the pulmonary veins. N Engl J Med. 1998;339:659–66.CrossRefPubMed
2.
go back to reference Calkins H, Reynolds MR, Spector P, Sondhi M, Xu Y, Martin A, et al. Treatment of atrial fibrillation with antiarrhythmic drugs or radiofrequency ablation: two systematic literature reviews and meta-analyses. Circ Arrhythm Electrophysiol. 2009;2:349–61.CrossRefPubMed Calkins H, Reynolds MR, Spector P, Sondhi M, Xu Y, Martin A, et al. Treatment of atrial fibrillation with antiarrhythmic drugs or radiofrequency ablation: two systematic literature reviews and meta-analyses. Circ Arrhythm Electrophysiol. 2009;2:349–61.CrossRefPubMed
3.
go back to reference Ciconte G, de Asmundis C, Sieira J, Conte G, Di Giovanni G, Mugnai G, et al. Single 3-minute freeze for second-generation cryoballoon ablation: one-year follow-up after pulmonary vein isolation. Heart Rhythm. 2015;12:673–80.CrossRefPubMed Ciconte G, de Asmundis C, Sieira J, Conte G, Di Giovanni G, Mugnai G, et al. Single 3-minute freeze for second-generation cryoballoon ablation: one-year follow-up after pulmonary vein isolation. Heart Rhythm. 2015;12:673–80.CrossRefPubMed
4.
go back to reference Su W, Kowal R, Kowalski M, Metzner A, Svinarich JT, Wheelan K, et al. Best practice guide for cryoballoon ablation in atrial fibrillation: the complication experience of more than 3000 procedures. Heart Rhythm. 2015;12:1658–166.CrossRefPubMed Su W, Kowal R, Kowalski M, Metzner A, Svinarich JT, Wheelan K, et al. Best practice guide for cryoballoon ablation in atrial fibrillation: the complication experience of more than 3000 procedures. Heart Rhythm. 2015;12:1658–166.CrossRefPubMed
5.
go back to reference Kenigsberg DN, Martin N, Lim HW, Kowalski M, Ellenbogen K. Quantification of the cryoablation zone demarcated by pre and postprocedural electroanatomic mapping in atrial fibrillation patients using the 28-mm second-generation cryoballoon. Heart Rhythm. 2015;12:283–90.PubMed Kenigsberg DN, Martin N, Lim HW, Kowalski M, Ellenbogen K. Quantification of the cryoablation zone demarcated by pre and postprocedural electroanatomic mapping in atrial fibrillation patients using the 28-mm second-generation cryoballoon. Heart Rhythm. 2015;12:283–90.PubMed
6.
go back to reference Bordignon S, Fürnkranz A, Dugo D, Perrotta L, Gunawardene M, Bode F, et al. Improved lesion formation using the novel 28 mm cryoballoon in atrial fibrillation ablation: analysis of biomarker release. Europace. 2014;16:987–93.CrossRefPubMed Bordignon S, Fürnkranz A, Dugo D, Perrotta L, Gunawardene M, Bode F, et al. Improved lesion formation using the novel 28 mm cryoballoon in atrial fibrillation ablation: analysis of biomarker release. Europace. 2014;16:987–93.CrossRefPubMed
7.
go back to reference Ghosh J, Martin A, Keech AC, Chan KH, Gomes S, Singarayar S, et al. Balloon warming time is the strongest predictor of late pulmonary vein electrical reconnection following cryoballoon ablation for atrial fibrillation. Heart Rhythm. 2013;10:1311–7.PubMed Ghosh J, Martin A, Keech AC, Chan KH, Gomes S, Singarayar S, et al. Balloon warming time is the strongest predictor of late pulmonary vein electrical reconnection following cryoballoon ablation for atrial fibrillation. Heart Rhythm. 2013;10:1311–7.PubMed
8.
go back to reference Ciconte G, Mugnai G, Sieira J, Velagić V, Saitoh Y, Irfan G, et al. On the quest for the best freeze: predictors of late pulmonary vein reconnections after second-generation cryoballoon ablation. Circ Arrhythm Electrophysiol. 2015;8:1359–65.PubMed Ciconte G, Mugnai G, Sieira J, Velagić V, Saitoh Y, Irfan G, et al. On the quest for the best freeze: predictors of late pulmonary vein reconnections after second-generation cryoballoon ablation. Circ Arrhythm Electrophysiol. 2015;8:1359–65.PubMed
9.
go back to reference Aryana A, Mugnai G, Singh SM, Pujara DK, de Asmundis C, Singh SK, et al. Procedural and biophysical indicators of durable pulmonary vein isolation during cryoballoon ablation of atrial fibrillation. Heart Rhythm. 2016;13:424–32.PubMed Aryana A, Mugnai G, Singh SM, Pujara DK, de Asmundis C, Singh SK, et al. Procedural and biophysical indicators of durable pulmonary vein isolation during cryoballoon ablation of atrial fibrillation. Heart Rhythm. 2016;13:424–32.PubMed
10.
go back to reference Matsumoto Y, Kaneshiro T, Hijioka N, Nodera M, Yamada S, Kamioka M, et al. Predicting factors of transmural thermal injury after cryoballoon pulmonary vein isolation. J Interv Card Electrophysiol. 2019;54:101–8.PubMed Matsumoto Y, Kaneshiro T, Hijioka N, Nodera M, Yamada S, Kamioka M, et al. Predicting factors of transmural thermal injury after cryoballoon pulmonary vein isolation. J Interv Card Electrophysiol. 2019;54:101–8.PubMed
11.
go back to reference Neumann T, Vogt J, Schumacher B, Dorszewski A, Kuniss M, Neuser H, et al. Circumferential pulmonary vein isolation with the cryoballoon technique results from a prospective 3-center study. J Am Coll Cardiol. 2008;52:273–8.PubMed Neumann T, Vogt J, Schumacher B, Dorszewski A, Kuniss M, Neuser H, et al. Circumferential pulmonary vein isolation with the cryoballoon technique results from a prospective 3-center study. J Am Coll Cardiol. 2008;52:273–8.PubMed
12.
go back to reference Mugnai G, Moran D, Ströker E, Ruggiero D, Coutino-Moreno HE, Takarada K, et al. Cryoballoon ablation during atrial fibrillation is associated with faster temperature drop and lower freezing temperatures. J Interv Card Electrophysiol. 2016;47:357–64.PubMed Mugnai G, Moran D, Ströker E, Ruggiero D, Coutino-Moreno HE, Takarada K, et al. Cryoballoon ablation during atrial fibrillation is associated with faster temperature drop and lower freezing temperatures. J Interv Card Electrophysiol. 2016;47:357–64.PubMed
14.
go back to reference Inamura Y, Nitta J, Inaba O, Kono T, Ikenouchi T, Murata k, et al. Differences in the electrophysiological findings of repeat ablation between patients who first underwent cryoballoon ablation and radiofrequency catheter ablation for paroxysmal atrial fibrillation. J Cardiovasc Electrophysiol. 2019. https://doi.org/10.1111/jce.14065. Inamura Y, Nitta J, Inaba O, Kono T, Ikenouchi T, Murata k, et al. Differences in the electrophysiological findings of repeat ablation between patients who first underwent cryoballoon ablation and radiofrequency catheter ablation for paroxysmal atrial fibrillation. J Cardiovasc Electrophysiol. 2019. https://​doi.​org/​10.​1111/​jce.​14065.
15.
go back to reference Ho SY, Sanchez-Quintana D, Cabrera JA, Anderson RH. Anatomy of the left atrium: implications for radiofrequency ablation of atrial fibrillation. J Cardiovasc Electrophysiol. 1999;10:1525–33.PubMed Ho SY, Sanchez-Quintana D, Cabrera JA, Anderson RH. Anatomy of the left atrium: implications for radiofrequency ablation of atrial fibrillation. J Cardiovasc Electrophysiol. 1999;10:1525–33.PubMed
16.
go back to reference Ichihara N, Miyazaki S, Kuroi A, Hachiya H, Nakamura H, Taniguchi H, et al. Impact of pulmonary vein isolation on superior vena cava potentials with a second-generation cryoballoon. J Cardiovasc Electrophysiol. 2015;26:1321–6.PubMed Ichihara N, Miyazaki S, Kuroi A, Hachiya H, Nakamura H, Taniguchi H, et al. Impact of pulmonary vein isolation on superior vena cava potentials with a second-generation cryoballoon. J Cardiovasc Electrophysiol. 2015;26:1321–6.PubMed
Metadata
Title
Temperature drop in thawing phase reflects sufficient ice formation and better outcome of pulmonary vein isolation using second-generation cryoballoon
Authors
Takashi Kaneshiro
Naoko Hijioka
Yoshiyuki Matsumoto
Minoru Nodera
Shinya Yamada
Masashi Kamioka
Yasuchika Takeishi
Publication date
01-11-2020
Publisher
Springer US
Published in
Journal of Interventional Cardiac Electrophysiology / Issue 2/2020
Print ISSN: 1383-875X
Electronic ISSN: 1572-8595
DOI
https://doi.org/10.1007/s10840-019-00659-z

Other articles of this Issue 2/2020

Journal of Interventional Cardiac Electrophysiology 2/2020 Go to the issue