Skip to main content
Top
Published in: Journal of Interventional Cardiac Electrophysiology 2/2018

Open Access 01-07-2018

Value of implantable loop recorders in patients with structural or electrical heart disease

Authors: Rafi Sakhi, Dominic A. M. J. Theuns, Rohit E. Bhagwandien, Michelle Michels, Arend F. L. Schinkel, Tamas Szili-Torok, F. Zijlstra, Jolien W. Roos-Hesselink, Sing-Chien Yap

Published in: Journal of Interventional Cardiac Electrophysiology | Issue 2/2018

Login to get access

Abstract

Purpose

In patients with structural heart disease (SHD) or inherited primary arrhythmia syndrome (IPAS), the occurrence of unexplained syncope or palpitations can be worrisome as they are at increased risk of sudden cardiac death. An implantable loop recorder (ILR) can be a useful diagnostic tool. Our purpose was to compare the diagnostic yield, arrhythmia mechanism, and management in patients with SHD, patients with IPAS, and those without heart disease.

Methods

Retrospective single-center study in consecutive patients who underwent an ILR implantation.

Results

Between March 2013 and December 2016, a total of 94 patients received an ILR (SHD, n = 20; IPAS, n = 14; no SHD/IPAS, n = 60). The type of symptoms at the time of implantation was similar between groups. During a median follow-up of 10 months, 45% had an ILR-guided diagnosis. Patients with IPAS had a lower diagnostic yield (14%) in comparison to the other groups (no SHD/IPAS 47%, P = 0.03; SHD 60%, P = 0.01, respectively). Furthermore, patients with SHD had a higher incidence of nonsustained VT in comparison to patients without SHD/IPAS (30 versus 3%, P < 0.01). ILR-guided therapy was comparable between groups. In the SHD group, a high proportion (10%) received an implantable cardioverter-defibrillator; however, this was not statistically significantly higher than the other groups (no SHD/IPAS 3%, IPAS 0%, P = 0.08).

Conclusions

In comparison to patients without heart disease, the diagnostic yield of an ILR was lower in patients with IPAS and the prevalence of ILR-diagnosed nonsustained VT was higher in patients with SHD.
Literature
1.
go back to reference Edvardsson N, Frykman V, van Mechelen R, Mitro P, Mohii-Oskarsson A, Pasquie JL, et al. Use of an implantable loop recorder to increase the diagnostic yield in unexplained syncope: results from the PICTURE registry. Europace. 2011;13(2):262–9.CrossRefPubMed Edvardsson N, Frykman V, van Mechelen R, Mitro P, Mohii-Oskarsson A, Pasquie JL, et al. Use of an implantable loop recorder to increase the diagnostic yield in unexplained syncope: results from the PICTURE registry. Europace. 2011;13(2):262–9.CrossRefPubMed
2.
go back to reference Farwell DJ, Freemantle N, Sulke N. The clinical impact of implantable loop recorders in patients with syncope. Eur Heart J. 2006;27(3):351–6.CrossRefPubMed Farwell DJ, Freemantle N, Sulke N. The clinical impact of implantable loop recorders in patients with syncope. Eur Heart J. 2006;27(3):351–6.CrossRefPubMed
3.
go back to reference Giada F, Gulizia M, Francese M, Croci F, Santangelo L, Santomauro M, et al. Recurrent unexplained palpitations (RUP) study: comparison of implantable loop recorder versus conventional diagnostic strategy. J Am Coll Cardiol. 2007;49(19):1951–6.CrossRefPubMed Giada F, Gulizia M, Francese M, Croci F, Santangelo L, Santomauro M, et al. Recurrent unexplained palpitations (RUP) study: comparison of implantable loop recorder versus conventional diagnostic strategy. J Am Coll Cardiol. 2007;49(19):1951–6.CrossRefPubMed
4.
go back to reference Sanna T, Diener HC, Passman RS, Di Lazzaro V, Bernstein RA, Morillo CA, et al. Cryptogenic stroke and underlying atrial fibrillation. N Engl J Med. 2014;370(26):2478–86.CrossRefPubMed Sanna T, Diener HC, Passman RS, Di Lazzaro V, Bernstein RA, Morillo CA, et al. Cryptogenic stroke and underlying atrial fibrillation. N Engl J Med. 2014;370(26):2478–86.CrossRefPubMed
5.
go back to reference Proclemer A, Lewalter T, Bongiorni MG, Svendsen JH, Pison L, Lundqvist CB, et al. Screening and risk evaluation for sudden cardiac death in ischaemic and non-ischaemic cardiomyopathy: results of the European Heart Rhythm Association survey. Europace. 2013;15(7):1059–62.CrossRefPubMed Proclemer A, Lewalter T, Bongiorni MG, Svendsen JH, Pison L, Lundqvist CB, et al. Screening and risk evaluation for sudden cardiac death in ischaemic and non-ischaemic cardiomyopathy: results of the European Heart Rhythm Association survey. Europace. 2013;15(7):1059–62.CrossRefPubMed
6.
go back to reference Brignole M, Vardas P, Hoffman E, Huikuri H, Moya A, Ricci R, et al. Indications for the use of diagnostic implantable and external ECG loop recorders. Europace. 2009;11(5):671–87.CrossRefPubMed Brignole M, Vardas P, Hoffman E, Huikuri H, Moya A, Ricci R, et al. Indications for the use of diagnostic implantable and external ECG loop recorders. Europace. 2009;11(5):671–87.CrossRefPubMed
7.
go back to reference Moya A, Sutton R, Ammirati F, Blanc JJ, Brignole M, Dahm JB, et al. Guidelines for the diagnosis and management of syncope (version 2009). Eur Heart J. 2009;30(21):2631–71.CrossRefPubMedPubMedCentral Moya A, Sutton R, Ammirati F, Blanc JJ, Brignole M, Dahm JB, et al. Guidelines for the diagnosis and management of syncope (version 2009). Eur Heart J. 2009;30(21):2631–71.CrossRefPubMedPubMedCentral
8.
go back to reference Antzelevitch C, Yan GX, Ackerman MJ, Borggrefe M, Corrado D, Guo J, et al. J-wave syndromes expert consensus conference report: emerging concepts and gaps in knowledge. Europace. 2017;19(4):665–94.PubMed Antzelevitch C, Yan GX, Ackerman MJ, Borggrefe M, Corrado D, Guo J, et al. J-wave syndromes expert consensus conference report: emerging concepts and gaps in knowledge. Europace. 2017;19(4):665–94.PubMed
9.
go back to reference Pezawas T, Stix G, Kastner J, Schneider B, Wolzt M, Schmidinger H. Implantable loop recorder in unexplained syncope: classification, mechanism, transient loss of consciousness and role of major depressive disorder in patients with and without structural heart disease. Heart. 2008;94(4):e17.CrossRefPubMed Pezawas T, Stix G, Kastner J, Schneider B, Wolzt M, Schmidinger H. Implantable loop recorder in unexplained syncope: classification, mechanism, transient loss of consciousness and role of major depressive disorder in patients with and without structural heart disease. Heart. 2008;94(4):e17.CrossRefPubMed
10.
go back to reference Solano A, Menozzi C, Maggi R, Donateo P, Bottoni N, Lolli G, et al. Incidence, diagnostic yield and safety of the implantable loop-recorder to detect the mechanism of syncope in patients with and without structural heart disease. Eur Heart J. 2004;25(13):1116–9.CrossRefPubMed Solano A, Menozzi C, Maggi R, Donateo P, Bottoni N, Lolli G, et al. Incidence, diagnostic yield and safety of the implantable loop-recorder to detect the mechanism of syncope in patients with and without structural heart disease. Eur Heart J. 2004;25(13):1116–9.CrossRefPubMed
11.
go back to reference Priori SG, Blomstrom-Lundqvist C, Mazzanti A, Blom N, Borggrefe M, Camm J, et al. ESC Guidelines for the management of patients with ventricular arrhythmias and the prevention of sudden cardiac death: the Task Force for the Management of Patients with Ventricular Arrhythmias and the Prevention of Sudden Cardiac Death of the European Society of Cardiology (ESC). Endorsed by: Association for European Paediatric and Congenital Cardiology (AEPC). Eur Heart J. 2015;36(41):2793–867.CrossRefPubMed Priori SG, Blomstrom-Lundqvist C, Mazzanti A, Blom N, Borggrefe M, Camm J, et al. ESC Guidelines for the management of patients with ventricular arrhythmias and the prevention of sudden cardiac death: the Task Force for the Management of Patients with Ventricular Arrhythmias and the Prevention of Sudden Cardiac Death of the European Society of Cardiology (ESC). Endorsed by: Association for European Paediatric and Congenital Cardiology (AEPC). Eur Heart J. 2015;36(41):2793–867.CrossRefPubMed
12.
go back to reference Champagne J, Philippon F, Gilbert M, Molin F, Blier L, Nault I, et al. The Brugada syndrome in Canada: a unique French-Canadian experience. Can J Cardiol. 2007;23(Suppl B):71B–5B.CrossRefPubMedPubMedCentral Champagne J, Philippon F, Gilbert M, Molin F, Blier L, Nault I, et al. The Brugada syndrome in Canada: a unique French-Canadian experience. Can J Cardiol. 2007;23(Suppl B):71B–5B.CrossRefPubMedPubMedCentral
13.
go back to reference Kubala M, Aissou L, Traulle S, Gugenheim AL, Hermida JS. Use of implantable loop recorders in patients with Brugada syndrome and suspected risk of ventricular arrhythmia. Europace. 2012;14(6):898–902.CrossRefPubMed Kubala M, Aissou L, Traulle S, Gugenheim AL, Hermida JS. Use of implantable loop recorders in patients with Brugada syndrome and suspected risk of ventricular arrhythmia. Europace. 2012;14(6):898–902.CrossRefPubMed
14.
go back to reference Sacher F, Arsac F, Wilton SB, Derval N, Denis A, de Guillebon M, et al. Syncope in Brugada syndrome patients: prevalence, characteristics, and outcome. Heart Rhythm. 2012;9(8):1272–9.CrossRefPubMed Sacher F, Arsac F, Wilton SB, Derval N, Denis A, de Guillebon M, et al. Syncope in Brugada syndrome patients: prevalence, characteristics, and outcome. Heart Rhythm. 2012;9(8):1272–9.CrossRefPubMed
15.
go back to reference Avari Silva JN, Bromberg BI, Emge FK, Bowman TM, Van Hare GF. Implantable loop recorder monitoring for refining management of children with inherited arrhythmia syndromes. J Am Heart Assoc. 2016;5(6):e003632.CrossRefPubMedPubMedCentral Avari Silva JN, Bromberg BI, Emge FK, Bowman TM, Van Hare GF. Implantable loop recorder monitoring for refining management of children with inherited arrhythmia syndromes. J Am Heart Assoc. 2016;5(6):e003632.CrossRefPubMedPubMedCentral
16.
go back to reference Frangini PA, Cecchin F, Jordao L, Martuscello M, Alexander ME, Triedman JK, et al. How revealing are insertable loop recorders in pediatrics? Pacing Clin Electrophysiol. 2008;31(3):338–43.CrossRefPubMed Frangini PA, Cecchin F, Jordao L, Martuscello M, Alexander ME, Triedman JK, et al. How revealing are insertable loop recorders in pediatrics? Pacing Clin Electrophysiol. 2008;31(3):338–43.CrossRefPubMed
17.
go back to reference Stollberger C, Keller H, Steger C, Finsterer J. Implantable loop-recorders in myopathic and non-myopathic patients with left ventricular hypertrabeculation/noncompaction. Int J Cardiol. 2013;163(2):146–8.CrossRefPubMed Stollberger C, Keller H, Steger C, Finsterer J. Implantable loop-recorders in myopathic and non-myopathic patients with left ventricular hypertrabeculation/noncompaction. Int J Cardiol. 2013;163(2):146–8.CrossRefPubMed
18.
go back to reference Kenny D, Chakrabarti S, Ranasinghe A, Chambers A, Martin R, Stuart G. Single-centre use of implantable loop recorders in patients with congenital heart disease. Europace. 2009;11(3):303–7.CrossRefPubMed Kenny D, Chakrabarti S, Ranasinghe A, Chambers A, Martin R, Stuart G. Single-centre use of implantable loop recorders in patients with congenital heart disease. Europace. 2009;11(3):303–7.CrossRefPubMed
19.
go back to reference Sanatani S, Peirone A, Chiu C, Human DG, Gross GJ, Hamilton RM. Use of an implantable loop recorder in the evaluation of children with congenital heart disease. Am Heart J. 2002;143(2):366–72.CrossRefPubMed Sanatani S, Peirone A, Chiu C, Human DG, Gross GJ, Hamilton RM. Use of an implantable loop recorder in the evaluation of children with congenital heart disease. Am Heart J. 2002;143(2):366–72.CrossRefPubMed
20.
go back to reference Weidemann F, Maier SK, Stork S, Brunner T, Liu D, Hu K, et al. Usefulness of an implantable loop recorder to detect clinically relevant arrhythmias in patients with advanced Fabry cardiomyopathy. Am J Cardiol. 2016;118(2):264–74.CrossRefPubMed Weidemann F, Maier SK, Stork S, Brunner T, Liu D, Hu K, et al. Usefulness of an implantable loop recorder to detect clinically relevant arrhythmias in patients with advanced Fabry cardiomyopathy. Am J Cardiol. 2016;118(2):264–74.CrossRefPubMed
21.
go back to reference Schernthaner C, Danmayr F, Altenberger J, Pichler M, Strohmer B. High incidence of tachyarrhythmias detected by an implantable loop recorder in patients with unexplained syncope. Kardiol Pol. 2008;66(1):37–44. discussion 5-6PubMed Schernthaner C, Danmayr F, Altenberger J, Pichler M, Strohmer B. High incidence of tachyarrhythmias detected by an implantable loop recorder in patients with unexplained syncope. Kardiol Pol. 2008;66(1):37–44. discussion 5-6PubMed
Metadata
Title
Value of implantable loop recorders in patients with structural or electrical heart disease
Authors
Rafi Sakhi
Dominic A. M. J. Theuns
Rohit E. Bhagwandien
Michelle Michels
Arend F. L. Schinkel
Tamas Szili-Torok
F. Zijlstra
Jolien W. Roos-Hesselink
Sing-Chien Yap
Publication date
01-07-2018
Publisher
Springer US
Published in
Journal of Interventional Cardiac Electrophysiology / Issue 2/2018
Print ISSN: 1383-875X
Electronic ISSN: 1572-8595
DOI
https://doi.org/10.1007/s10840-018-0354-y

Other articles of this Issue 2/2018

Journal of Interventional Cardiac Electrophysiology 2/2018 Go to the issue