Published in: The International Journal of Cardiovascular Imaging 10/2018

01-10-2018 | Orginal Paper

Semi-automatic CT-angiography based evaluation of the aortic annulus in patients prior to TAVR: interchangeability with manual measurements

Authors: Dominik Zinsser, Alena B Baumann, Katharina Stella Winter, Fabian Bamberg, Philipp Lange, Konstantin Nikolaou, Maximilian Reiser, Christian Kupatt, Thomas Kröncke, Florian Schwarz

Published in: The International Journal of Cardiovascular Imaging | Issue 10/2018

Login to get access

Abstract

To compare a semi-automatic software tool for the measurement of aortic annulus dimensions with manual measurements by expert readers and to analyze whether and to what extent interchangeability exists between semi-automatic and manual measurements. We retrospectively included 374 consecutive patients with high-grade aortic stenosis who had undergone CT-angiography of the heart prior to trans-catheter aortic valve replacement (TAVR). In independent analyses, two expert readers manually measured aortic annulus dimensions (long axis, short axis, circumference, area) as well as the distance of the coronary ostia from the annulus plane. A third independent reader performed annulus evaluation using a software tool for semi-automatic detection and measurement of the annulus plane. Intraclass correlation coefficients (ICC) and Bland–Altman analysis was used to compare both manual measurements as well as manual and semi-automatic measurements of annulus parameters. Using the respective measurements we simulated size selection for a Sapien XT transcatheter heart valve (THV). Interchangeability of methods was addressed by calculation of the estimated individual equivalence index γ. There was excellent agreement between both expert observers in manual measurements of the annulus with ICC’s in the range 0.89–0.94 for all anatomic parameters. Similar high agreements were observed between semi-automatic and manual measurements, with ICC’s in the range of 0.89–0.95. THV size recommendation based on manual versus semiautomatic measurements agreed in 80.7% of cases while agreement between both expert readers concerning THV size recommendation was 80.6%. Semi-automatic measurements of anatomic parameters of the aortic root show high agreement and interchangeability with manual measurements in CT-angiography prior to TAVR.
Appendix
Available only for authorised users
Literature
16.
go back to reference Obuchowski NA (2001) Can electronic medical images replace hard-copy film? Defining and testing the equivalence of diagnostic tests. Stat Med 20:2845–2863CrossRefPubMed Obuchowski NA (2001) Can electronic medical images replace hard-copy film? Defining and testing the equivalence of diagnostic tests. Stat Med 20:2845–2863CrossRefPubMed
Metadata
Title
Semi-automatic CT-angiography based evaluation of the aortic annulus in patients prior to TAVR: interchangeability with manual measurements
Authors
Dominik Zinsser
Alena B Baumann
Katharina Stella Winter
Fabian Bamberg
Philipp Lange
Konstantin Nikolaou
Maximilian Reiser
Christian Kupatt
Thomas Kröncke
Florian Schwarz
Publication date
01-10-2018
Publisher
Springer Netherlands
Published in
The International Journal of Cardiovascular Imaging / Issue 10/2018
Print ISSN: 1569-5794
Electronic ISSN: 1875-8312
DOI
https://doi.org/10.1007/s10554-018-1377-2

Other articles of this Issue 10/2018

The International Journal of Cardiovascular Imaging 10/2018 Go to the issue