Skip to main content
Top
Published in: The International Journal of Cardiovascular Imaging 10/2016

01-10-2016 | Original Paper

Asymmetric pulsation of rat carotid artery bifurcation in three-dimension observed by ultrasound imaging

Authors: Changzhu Jin, Kweon-Ho Nam, Dong-Guk Paeng

Published in: The International Journal of Cardiovascular Imaging | Issue 10/2016

Login to get access

Abstract

The arterial structure cyclically fluctuates in three-dimensions (3-D) caused by pulsatile blood flow. The evaluation of arterial wall motion and hemodynamics contributes to early diagnosis of carotid atherosclerosis. Ultrasound is one of the most appropriate imaging modalities to evaluate arterial wall motion in real time. Although many previous studies have discussed the mechanical properties of the carotid artery bifurcation (CAB) from the two-dimensional (2-D) view, the spatio-temporal variation of carotid artery geometry in 3-D has not yet been investigated in detail. In this study, the 3-D data set of CAB from rats was acquired using a high spatio-temporal resolution ultrasound imaging system with a 40 MHz probe using mechanical sector scanning. A total of 31 slices of cross-section images were stored and a spoke scan algorithm was implemented to radially scan the lumen area in polar coordinates based on a pre-tracked seed point. The boundary of the arterial lumen was segmented using intensity-threshold-based boundary detection and fitted by polynomial regression. Two operators, who were trained with the same protocol to minimize inter- and intra-operator variability, manually segmented the lumen boundary on systolic and diastolic phase from the gray-scale images. Finally, the 3-D lumen geometries of CAB during one cardiac cycle were constructed based on the segmented lumen boundaries. From this constructed 3-D geometry, we observed that the CAB geometry favorably expanded to the anterior/posterior direction, parallel to the sagittal plane; and the manually segmented geometry also confirmed the asymmetrical change in bifurcation geometry. This is the first study on visualization and quantification on the asymmetrical variation of the CAB geometry of a rat in 3-D during a whole cardiac cycle. This finding may be useful in understanding hemodynamic etiology of various cardiovascular diseases such as arterial stenosis and its complications, and also provides reference information for numerical simulation studies on arterial wall motion.
Appendix
Available only for authorised users
Literature
1.
go back to reference Robinson JG, Leon AS (1994) The prevention of cardiovascular disease. Emphasis on secondary prevention. Med Clin North Am 78(1):69–98CrossRefPubMed Robinson JG, Leon AS (1994) The prevention of cardiovascular disease. Emphasis on secondary prevention. Med Clin North Am 78(1):69–98CrossRefPubMed
2.
go back to reference Novo S, Pernice C, Geraci AM, Longo B, Barbagallo CM, Caruso R, Liquori M, Putignano E, Barbagallo Sangiorgi G, Strano A (1995) Risk factors, ageing, and asymptomatic carotid plaque. Cardiologia 40(12 Suppl 1):263–272PubMed Novo S, Pernice C, Geraci AM, Longo B, Barbagallo CM, Caruso R, Liquori M, Putignano E, Barbagallo Sangiorgi G, Strano A (1995) Risk factors, ageing, and asymptomatic carotid plaque. Cardiologia 40(12 Suppl 1):263–272PubMed
3.
go back to reference Schulz UG, Rothwell PM (2001) Major variation in carotid bifurcation anatomy: a possible risk factor for plaque development? Stroke 32(11):2522–2529CrossRefPubMed Schulz UG, Rothwell PM (2001) Major variation in carotid bifurcation anatomy: a possible risk factor for plaque development? Stroke 32(11):2522–2529CrossRefPubMed
4.
go back to reference Al-Rafiah A, AA EL-H, Aal IH, Zaki AI (2011) Anatomical study of the carotid bifurcation and origin variations of the ascending pharyngeal and superior thyroid arteries. Folia Morphol (Warsz) 70(1):47–55 Al-Rafiah A, AA EL-H, Aal IH, Zaki AI (2011) Anatomical study of the carotid bifurcation and origin variations of the ascending pharyngeal and superior thyroid arteries. Folia Morphol (Warsz) 70(1):47–55
5.
go back to reference Spelde AG, de Vos RA, Hoogendam IJ, Heethaar RM (1990) Pathological-anatomical study concerning the geometry and atherosclerosis of the carotid bifurcation. Eur J Vasc Surg 4(4):345–348CrossRefPubMed Spelde AG, de Vos RA, Hoogendam IJ, Heethaar RM (1990) Pathological-anatomical study concerning the geometry and atherosclerosis of the carotid bifurcation. Eur J Vasc Surg 4(4):345–348CrossRefPubMed
6.
go back to reference Bakheit MA, Gahatani FM (2014) Low bifurcation of the common carotid arteries: an anatomical and radiological study. East Mediterr Health J 19(Suppl3):S227–S228PubMed Bakheit MA, Gahatani FM (2014) Low bifurcation of the common carotid arteries: an anatomical and radiological study. East Mediterr Health J 19(Suppl3):S227–S228PubMed
8.
go back to reference Milner JS, Moore JA, Rutt BK, Steinman DA (1998) Hemodynamics of human carotid artery bifurcations: computational studies with models reconstructed from magnetic resonance imaging of normal subjects. J Vasc Surg 28(1):143–156CrossRefPubMed Milner JS, Moore JA, Rutt BK, Steinman DA (1998) Hemodynamics of human carotid artery bifurcations: computational studies with models reconstructed from magnetic resonance imaging of normal subjects. J Vasc Surg 28(1):143–156CrossRefPubMed
9.
10.
go back to reference Uemiya N, Lee CJ, Ishihara S, Yamane F, Zhang Y, Qian Y (2013) Analysis of restenosis after carotid artery stenting: preliminary results using computational fluid dynamics based on three-dimensional angiography. J Clin Neurosci 20(11):1582–1587. doi:10.1016/j.jocn.2013.03.042 CrossRefPubMed Uemiya N, Lee CJ, Ishihara S, Yamane F, Zhang Y, Qian Y (2013) Analysis of restenosis after carotid artery stenting: preliminary results using computational fluid dynamics based on three-dimensional angiography. J Clin Neurosci 20(11):1582–1587. doi:10.​1016/​j.​jocn.​2013.​03.​042 CrossRefPubMed
12.
go back to reference Moyle KR, Antiga L, Steinman DA (2006) Inlet conditions for image-based CFD models of the carotid bifurcation: is it reasonable to assume fully developed flow? J Biomech Eng 128(3):371–379. doi:10.1115/1.2187035 CrossRefPubMed Moyle KR, Antiga L, Steinman DA (2006) Inlet conditions for image-based CFD models of the carotid bifurcation: is it reasonable to assume fully developed flow? J Biomech Eng 128(3):371–379. doi:10.​1115/​1.​2187035 CrossRefPubMed
13.
go back to reference Barratt DC, Ariff BB, Humphries KN, Thom SA, Hughes AD (2004) Reconstruction and quantification of the carotid artery bifurcation from 3-D ultrasound images. IEEE Trans Med Imaging 23(5):567–583CrossRefPubMed Barratt DC, Ariff BB, Humphries KN, Thom SA, Hughes AD (2004) Reconstruction and quantification of the carotid artery bifurcation from 3-D ultrasound images. IEEE Trans Med Imaging 23(5):567–583CrossRefPubMed
22.
go back to reference Ku DN, Giddens DP, Zarins CK, Glagov S (1985) Pulsatile flow and atherosclerosis in the human carotid bifurcation. Positive correlation between plaque location and low oscillating shear stress. Arteriosclerosis 5(3):293–302CrossRefPubMed Ku DN, Giddens DP, Zarins CK, Glagov S (1985) Pulsatile flow and atherosclerosis in the human carotid bifurcation. Positive correlation between plaque location and low oscillating shear stress. Arteriosclerosis 5(3):293–302CrossRefPubMed
23.
go back to reference Heiss C, Sievers RE, Amabile N, Momma TY, Chen Q, Natarajan S, Yeghiazarians Y, Springer ML (2008) In vivo measurement of flow-mediated vasodilation in living rats using high-resolution ultrasound. Am J Physiol Heart Circu Physiol 294(2):H1086–H1093. doi:10.1152/ajpheart.00811.2007 CrossRef Heiss C, Sievers RE, Amabile N, Momma TY, Chen Q, Natarajan S, Yeghiazarians Y, Springer ML (2008) In vivo measurement of flow-mediated vasodilation in living rats using high-resolution ultrasound. Am J Physiol Heart Circu Physiol 294(2):H1086–H1093. doi:10.​1152/​ajpheart.​00811.​2007 CrossRef
25.
go back to reference Chow TY, Cheung JS, Wu Y, Guo H, Chan KC, Hui ES, Wu EX (2008) Measurement of common carotid artery lumen dynamics during the cardiac cycle using magnetic resonance TrueFISP cine imaging. J Magn Reson Imaging 28(6):1527–1532. doi:10.1002/jmri.21527 CrossRefPubMed Chow TY, Cheung JS, Wu Y, Guo H, Chan KC, Hui ES, Wu EX (2008) Measurement of common carotid artery lumen dynamics during the cardiac cycle using magnetic resonance TrueFISP cine imaging. J Magn Reson Imaging 28(6):1527–1532. doi:10.​1002/​jmri.​21527 CrossRefPubMed
Metadata
Title
Asymmetric pulsation of rat carotid artery bifurcation in three-dimension observed by ultrasound imaging
Authors
Changzhu Jin
Kweon-Ho Nam
Dong-Guk Paeng
Publication date
01-10-2016
Publisher
Springer Netherlands
Published in
The International Journal of Cardiovascular Imaging / Issue 10/2016
Print ISSN: 1569-5794
Electronic ISSN: 1875-8312
DOI
https://doi.org/10.1007/s10554-016-0934-9

Other articles of this Issue 10/2016

The International Journal of Cardiovascular Imaging 10/2016 Go to the issue