Skip to main content
Top
Published in: The International Journal of Cardiovascular Imaging 2/2012

01-12-2012

Dual-source coronary CT angiography in patients with high heart rates using a prospectively ECG-triggered axial mode at end-systole

Authors: Hee Yeong Kim, Ji Won Lee, Yoo Jin Hong, Hye-Jeong Lee, Jin Hur, Ji Eun Nam, Byoung Wook Choi, Young Jin Kim

Published in: The International Journal of Cardiovascular Imaging | Special Issue 2/2012

Login to get access

Abstract

To determine the feasibility of dual-source coronary CT angiography (CTA) using a prospectively electrocardiogram (ECG)-triggered axial mode to target end-systole in patients with high heart rates (HR) as compared with the retrospective mode. One hundred fifty consecutive patients with regular HR > 75 bpm who underwent coronary CTA were enrolled; 75 patients underwent prospectively ECG-triggered coronary CTA targeting only end-systole (Prospective Axial Group) and 75 patients underwent retrospectively ECG-gated coronary CTA (Retrospective Helical Group). The image quality of multiple coronary artery segments was evaluated and radiation doses were recorded. The diagnostic performance of coronary CTA was compared to the reference standard of invasive coronary angiography in 52 patients (35 %) (28 patients in Prospective Axial Group and 24 patients in Retrospective Helical Group). Image quality was not significantly different between the 2 groups (P = 0.784). In subgroup analysis, segment-based sensitivity, specificity, and positive and negative predictive values of coronary CTA were 98, 96, 88 and 99 %, respectively, in the Prospective Axial Group and were 97, 95, 82, and 99 %, respectively, in the Retrospective Helical Group. Mean radiation dose was significantly lower for the Prospective Axial Group than for the Retrospective Helical Group (2.9 ± 1.4 vs. 7.4 ± 3.3 mSv; P < 0.0001). Dual source coronary CTA with a prospective ECG-triggered axial mode targeting end-systole is feasible in patients with regular high HRs for evaluation of coronary artery disease. It provides comparable image quality and diagnostic value with substantially lower radiation exposure as compared to the retrospective ECG–gated helical technique.
Literature
6.
go back to reference Shuman WP, Branch KR, May JM, Mitsumori LM, Lockhart DW, Dubinsky TJ, Warren BH, Caldwell JH (2008) Prospective versus retrospective ECG gating for 64-detector CT of the coronary arteries: comparison of image quality and patient radiation dose. Radiology 248(2):431–437. doi:10.1148/radiol.2482072192 PubMedCrossRef Shuman WP, Branch KR, May JM, Mitsumori LM, Lockhart DW, Dubinsky TJ, Warren BH, Caldwell JH (2008) Prospective versus retrospective ECG gating for 64-detector CT of the coronary arteries: comparison of image quality and patient radiation dose. Radiology 248(2):431–437. doi:10.​1148/​radiol.​2482072192 PubMedCrossRef
7.
go back to reference Abbara S, Arbab-Zadeh A, Callister TQ, Desai MY, Mamuya W, Thomson L, Weigold WG (2009) SCCT guidelines for performance of coronary computed tomographic angiography: a report of the society of cardiovascular computed tomography guidelines committee. J Cardiovasc Comput Tomogr 3(3):190–204. doi:10.1016/j.jcct.2009.03.004 PubMedCrossRef Abbara S, Arbab-Zadeh A, Callister TQ, Desai MY, Mamuya W, Thomson L, Weigold WG (2009) SCCT guidelines for performance of coronary computed tomographic angiography: a report of the society of cardiovascular computed tomography guidelines committee. J Cardiovasc Comput Tomogr 3(3):190–204. doi:10.​1016/​j.​jcct.​2009.​03.​004 PubMedCrossRef
8.
go back to reference Blanke P, Baumann T, Bulla S, Schaefer O, Kotter E, Langer M, Pache G (2010) Prospective ECG-triggered CT angiography of the thoracic aorta in patients with atrial fibrillation or accelerated heart rates: feasibility and image quality. Am J Roentgenol 194(1):W111–114. doi:10.2214/AJR.09.3153 CrossRef Blanke P, Baumann T, Bulla S, Schaefer O, Kotter E, Langer M, Pache G (2010) Prospective ECG-triggered CT angiography of the thoracic aorta in patients with atrial fibrillation or accelerated heart rates: feasibility and image quality. Am J Roentgenol 194(1):W111–114. doi:10.​2214/​AJR.​09.​3153 CrossRef
9.
go back to reference Hou Y, Yue Y, Guo W, Feng G, Yu T, Li G, Vembar M, Olszewski ME, Guo Q (2012) Prospectively versus retrospectively ECG-gated 256-slice coronary CT angiography: image quality and radiation dose over expanded heart rates. Int J Cardiovasc Imaging 28(1):153–162. doi:10.1007/s10554-010-9760-7 PubMedCrossRef Hou Y, Yue Y, Guo W, Feng G, Yu T, Li G, Vembar M, Olszewski ME, Guo Q (2012) Prospectively versus retrospectively ECG-gated 256-slice coronary CT angiography: image quality and radiation dose over expanded heart rates. Int J Cardiovasc Imaging 28(1):153–162. doi:10.​1007/​s10554-010-9760-7 PubMedCrossRef
10.
go back to reference Xu L, Yang L, Zhang Z, Li Y, Fan Z, Ma X, Lv B, Yu W (2010) Low-dose adaptive sequential scan for dual-source CT coronary angiography in patients with high heart rate: comparison with retrospective ECG gating. Eur J Radiol 76(2):183–187. doi:10.1016/j.ejrad.2009.06.003 PubMedCrossRef Xu L, Yang L, Zhang Z, Li Y, Fan Z, Ma X, Lv B, Yu W (2010) Low-dose adaptive sequential scan for dual-source CT coronary angiography in patients with high heart rate: comparison with retrospective ECG gating. Eur J Radiol 76(2):183–187. doi:10.​1016/​j.​ejrad.​2009.​06.​003 PubMedCrossRef
11.
go back to reference Austen WG, Edwards JE, Frye RL, Gensini GG, Gott VL, Griffith LS, McGoon DC, Murphy ML, Roe BB (1975) A reporting system on patients evaluated for coronary artery disease. Report of the Ad Hoc Committee for Grading of Coronary Artery Disease, Council on Cardiovascular Surgery, American Heart Association. Circulation 51(4 Suppl):5–40PubMedCrossRef Austen WG, Edwards JE, Frye RL, Gensini GG, Gott VL, Griffith LS, McGoon DC, Murphy ML, Roe BB (1975) A reporting system on patients evaluated for coronary artery disease. Report of the Ad Hoc Committee for Grading of Coronary Artery Disease, Council on Cardiovascular Surgery, American Heart Association. Circulation 51(4 Suppl):5–40PubMedCrossRef
12.
go back to reference Matt D, Scheffel H, Leschka S, Flohr TG, Marincek B, Kaufmann PA, Alkadhi H (2007) Dual-source CT coronary angiography: image quality, mean heart rate, and heart rate variability. AJR Am J Roentgenol 189(3):567–573. doi:10.2214/AJR.07.2078 PubMedCrossRef Matt D, Scheffel H, Leschka S, Flohr TG, Marincek B, Kaufmann PA, Alkadhi H (2007) Dual-source CT coronary angiography: image quality, mean heart rate, and heart rate variability. AJR Am J Roentgenol 189(3):567–573. doi:10.​2214/​AJR.​07.​2078 PubMedCrossRef
14.
go back to reference Brodoefel H, Burgstahler C, Tsiflikas I, Reimann A, Schroeder S, Claussen CD, Heuschmid M, Kopp AF (2008) Dual-source CT: effect of heart rate, heart rate variability, and calcification on image quality and diagnostic accuracy. Radiology 247(2):346–355. doi:10.1148/radiol.2472070906 PubMedCrossRef Brodoefel H, Burgstahler C, Tsiflikas I, Reimann A, Schroeder S, Claussen CD, Heuschmid M, Kopp AF (2008) Dual-source CT: effect of heart rate, heart rate variability, and calcification on image quality and diagnostic accuracy. Radiology 247(2):346–355. doi:10.​1148/​radiol.​2472070906 PubMedCrossRef
15.
Metadata
Title
Dual-source coronary CT angiography in patients with high heart rates using a prospectively ECG-triggered axial mode at end-systole
Authors
Hee Yeong Kim
Ji Won Lee
Yoo Jin Hong
Hye-Jeong Lee
Jin Hur
Ji Eun Nam
Byoung Wook Choi
Young Jin Kim
Publication date
01-12-2012
Publisher
Springer Netherlands
Published in
The International Journal of Cardiovascular Imaging / Issue Special Issue 2/2012
Print ISSN: 1569-5794
Electronic ISSN: 1875-8312
DOI
https://doi.org/10.1007/s10554-012-0142-1

Other articles of this Special Issue 2/2012

The International Journal of Cardiovascular Imaging 2/2012 Go to the issue