Abstract

To evaluate the accuracy and feasibility of right ventricular function parameters measurement using 320-slice volume cardiac CT. Retrospective analysis of 50 consecutive patients (23 men, 27 women) with suspected pulmonary diseases was performed in electrocardiogram (ECG)-gated cardiac CT and cardiac magnetic resonance (CMR). Parameters including right ventricular end-diastolic volume (RVEDV), right ventricular end- systolic volume (RVESV), right ventricular stroke volume (RVSV), right ventricular cardiac output (RVCO), and right ventricular ejection fraction (RVEF) were semi-automatically and separately calculated from both CT and CMR data. Significant difference between measurements was measured by paired t test and two-variable linear regression analysis with Pearson’s correlation coefficient. Bland–Altman analysis was performed in each pair of parameters. There was little variability between the measurements by the two observers (kappa = 0.895–0.980, P < 0.05). There was good correlation between all parameters obtained by CT and CMR (P < 0.001): RVEDV (108.5 ± 21.9 ml, 113.5 ± 24.8 ml, r = 0.944), RVESV (69.8 ± 33.4 ml, 73.2 ± 35.4 ml, r = 0.972), RVSV (39.0 ± 13.2 ml, 40.2 ± 13.3 ml, r = 0.977), RVCO (2.6 ± 0.7 l, 2.6 ± 0.7 l. r = 0.958), RVEF (38.8 ± 19.1 %, 39.1 ± 19.3 %, r = 0.990), and there was no significant difference between CT and CMR measurements in RVEF (n = 50, t = −0.677, P > 0.05). 320-slice volume cardiac CT is an accurate non-invasive technique to evaluate RV function.
Literature
1.
go back to reference Menzel T, Kramm T, Bruckner A, Mohr-Kahaly S, Mayer E, Meyer J (2002) Quantitative assessment of right ventricular volumes in severe chronic thromboembolic pulmonary hypertension using transthoracic three-dimensional echocardiography: changes due to pulmonary thromboendarterectomy. Eur J Echocardiogr 3(1):67–72PubMedCrossRef Menzel T, Kramm T, Bruckner A, Mohr-Kahaly S, Mayer E, Meyer J (2002) Quantitative assessment of right ventricular volumes in severe chronic thromboembolic pulmonary hypertension using transthoracic three-dimensional echocardiography: changes due to pulmonary thromboendarterectomy. Eur J Echocardiogr 3(1):67–72PubMedCrossRef
2.
go back to reference Liang L, Xu W, Li K, Du X, Gao Y (2009) Assessment of right ventricular function with 64-detector CT. Chin J Med Imaging Technology 25(6):1025–1028 Liang L, Xu W, Li K, Du X, Gao Y (2009) Assessment of right ventricular function with 64-detector CT. Chin J Med Imaging Technology 25(6):1025–1028
3.
go back to reference Oldershaw P (1992) Assessment of right ventricular function and its role in clinical practice. Br Heart J 68(1):12–15PubMedCrossRef Oldershaw P (1992) Assessment of right ventricular function and its role in clinical practice. Br Heart J 68(1):12–15PubMedCrossRef
4.
go back to reference Goldstein J (2005) The right entricle: what’s right and what’s wrong. Coron Artery Dis 16:1–3CrossRef Goldstein J (2005) The right entricle: what’s right and what’s wrong. Coron Artery Dis 16:1–3CrossRef
5.
go back to reference Barkhausen J, Ruehm SG, Goyen M, Buck T, Laub G, Debatin JF (2001) MR evaluation of ventricular function: true fast imaging with steady-state precession versus fast low-angle shot cine MR imaging: feasibility study. Radiology 219(1):264–269PubMed Barkhausen J, Ruehm SG, Goyen M, Buck T, Laub G, Debatin JF (2001) MR evaluation of ventricular function: true fast imaging with steady-state precession versus fast low-angle shot cine MR imaging: feasibility study. Radiology 219(1):264–269PubMed
6.
go back to reference Mogelvang J, Stubgaard M, Thomsen C, Henriksen O (1988) Evaluation of right ventricular volumes measured by magnetic resonance imaging. Eur Heart J 9(5):529–533PubMed Mogelvang J, Stubgaard M, Thomsen C, Henriksen O (1988) Evaluation of right ventricular volumes measured by magnetic resonance imaging. Eur Heart J 9(5):529–533PubMed
8.
go back to reference Helbing WA, Bosch HG, Maliepaard C, Rebergen SA, van der Geest RJ, Hansen B, Ottenkamp J, Reiber JH, de Roos A (1995) Comparison of echocardiographic methods with magnetic resonance imaging for assessment of right ventricular function in children. Am J Cardiol 76(8):589–594PubMedCrossRef Helbing WA, Bosch HG, Maliepaard C, Rebergen SA, van der Geest RJ, Hansen B, Ottenkamp J, Reiber JH, de Roos A (1995) Comparison of echocardiographic methods with magnetic resonance imaging for assessment of right ventricular function in children. Am J Cardiol 76(8):589–594PubMedCrossRef
9.
go back to reference Danilouchkine MG, Westenberg JJ, de Roos A, Reiber JH, Lelieveldt BP (2005) Operator induced variability in cardiovascular MR: left ventricular measurements and their reproducibility. J Cardiovasc Magn Reson 7(2):447–457PubMedCrossRef Danilouchkine MG, Westenberg JJ, de Roos A, Reiber JH, Lelieveldt BP (2005) Operator induced variability in cardiovascular MR: left ventricular measurements and their reproducibility. J Cardiovasc Magn Reson 7(2):447–457PubMedCrossRef
10.
go back to reference Ghaye B, Ghuysen A, Bruyere PJ, D’Orio V, Dondelinger RF (2006) Can CT pulmonary angiography allow assessment of severity and prognosis in patients presenting with pulmonary embolism? What the radiologist needs to know. Radiographics 26(1):23–39. doi:10.1148/rg.261055062 discussion 39–40PubMedCrossRef Ghaye B, Ghuysen A, Bruyere PJ, D’Orio V, Dondelinger RF (2006) Can CT pulmonary angiography allow assessment of severity and prognosis in patients presenting with pulmonary embolism? What the radiologist needs to know. Radiographics 26(1):23–39. doi:10.​1148/​rg.​261055062 discussion 39–40PubMedCrossRef
12.
go back to reference Spencer KT, Garcia MJ, Weinart L, Vignon P, Lang R (1999) Assessment of right ventricular and right atrial systolic and diastolic performance using automated border detection. Echocardiography 16(7, Pt 1):643–652PubMedCrossRef Spencer KT, Garcia MJ, Weinart L, Vignon P, Lang R (1999) Assessment of right ventricular and right atrial systolic and diastolic performance using automated border detection. Echocardiography 16(7, Pt 1):643–652PubMedCrossRef
13.
go back to reference Thorne MC (1992) 1990 Recommendations of the International Commission on Radiological Protection. Ann ICRP 21(1–3):51–52. doi:0306-4549(92)90053-E Thorne MC (1992) 1990 Recommendations of the International Commission on Radiological Protection. Ann ICRP 21(1–3):51–52. doi:0306-4549(92)90053-E
14.
go back to reference Manzke R, Grass M, Nielsen T, Shechter G, Hawkes D (2003) Adaptive temporal resolution optimization in helical cardiac cone beam CT reconstruction. Med Phys 30(12):3072–3080PubMedCrossRef Manzke R, Grass M, Nielsen T, Shechter G, Hawkes D (2003) Adaptive temporal resolution optimization in helical cardiac cone beam CT reconstruction. Med Phys 30(12):3072–3080PubMedCrossRef
15.
go back to reference Wintersperger BJ, Nikolaou K (2005) Basics of cardiac MDCT: techniques and contrast application. Eur Radiol 15(Suppl 2):B2–B9PubMed Wintersperger BJ, Nikolaou K (2005) Basics of cardiac MDCT: techniques and contrast application. Eur Radiol 15(Suppl 2):B2–B9PubMed
Metadata
Title
Assessment of right ventricular function with 320-slice volume cardiac CT: comparison with cardiac magnetic resonance imaging
Authors
Xiaoyong Huang
Xin Pu
Ruiyu Dou
Xi Guo
Zixu Yan
Zhaoqi Zhang
Meng Li
Hong Jiang
Biao Lu
Publication date
01-12-2012
Publisher
Springer Netherlands
Published in
The International Journal of Cardiovascular Imaging / Issue Special Issue 2/2012
Print ISSN: 1569-5794
Electronic ISSN: 1875-8312
DOI
https://doi.org/10.1007/s10554-012-0156-8

Other articles of this Special Issue 2/2012

The International Journal of Cardiovascular Imaging 2/2012 Go to the issue