Skip to main content
Top
Published in: The International Journal of Cardiovascular Imaging 1/2011

01-12-2011 | Original Paper

Individually adapted coronary 64-slice CT angiography based on precontrast attenuation values, using different kVp and tube current settings: evaluation of image quality

Author: Jean-François Paul

Published in: The International Journal of Cardiovascular Imaging | Special Issue 1/2011

Login to get access

Abstract

To evaluate the feasibility of an individually adapted coronary CT protocol based on precontrast attenuation values using different kVp and tube current settings. All images were acquired on a 64-slice CT scanner (Sensation 64, Siemens) in 270 consecutive patients. X-ray tube current and kVp settings were defined in 6 groups depending on the noise measurements at the heart level on pre-control unenhanced CT. The contrast medium was 400 mg/ml of iodine given at 1 ml/kg. The duration of injection was at 17 s in all cases, so the flow rate was adapted accordingly. Contrast enhancement and noise were measured from enhanced scans of the aortic root. The contrast to noise ratio (CNR) was used as an indicator of image quality. The mean contrast enhancement was 391 ± 83 HU. The mean radiation dose was 9.4 mSv (1.4–30.4 mSv). The mean noise was 39.8 ± 7.7 HU; noise was not significantly different between the groups, except for the 80 kVp group (mean noise = 54.5 HU, P < 0.05). The mean CNR was 10.1 ± 2.5, and CNR was similar in groups 1, 3, 4, and 5 (scanned at 80 kVp or 120 kVp), but significantly higher (CNR = 12) in group 2 (100 kVp) and significantly lower (CNR = 7.9) in group 6 (140 kVp). Individual adaptation of radiation dose is feasible in routine clinical coronary multislice CT, at various kVp and mAs settings. Image quality may be preserved with substantial radiation dose savings in patients with low attenuation values on precontrast images.
Literature
1.
go back to reference Cademartiri F, Mollet NR, Lemos PA et al (2006) Higher intracoronary attenuation improves diagnostic accuracy in MDCT coronary angiography. AJR Am J Roentgenol 187(4):W430–W433PubMedCrossRef Cademartiri F, Mollet NR, Lemos PA et al (2006) Higher intracoronary attenuation improves diagnostic accuracy in MDCT coronary angiography. AJR Am J Roentgenol 187(4):W430–W433PubMedCrossRef
2.
go back to reference Kalender WA (2000) Computed tomography—fundamentals, system technology, image quality, applications. Publicis MCD Verlag, Erlangen Kalender WA (2000) Computed tomography—fundamentals, system technology, image quality, applications. Publicis MCD Verlag, Erlangen
3.
go back to reference Sigal-Cinqualbre AB, Hennequin R, Abada HT et al (2004) Low-kilovoltage multi-detector row chest CT in adults: feasibility and effect on image quality and iodine dose. Radiology 231(1):169–174PubMedCrossRef Sigal-Cinqualbre AB, Hennequin R, Abada HT et al (2004) Low-kilovoltage multi-detector row chest CT in adults: feasibility and effect on image quality and iodine dose. Radiology 231(1):169–174PubMedCrossRef
4.
go back to reference Tatsugami F, Husmann L, Herzog BA et al (2009) Evaluation of a body mass index-adapted protocol for low-dose 64-MDCT coronary angiography with prospective ECG triggering. AJR Am J Roentgenol 192(3):635–638PubMedCrossRef Tatsugami F, Husmann L, Herzog BA et al (2009) Evaluation of a body mass index-adapted protocol for low-dose 64-MDCT coronary angiography with prospective ECG triggering. AJR Am J Roentgenol 192(3):635–638PubMedCrossRef
5.
go back to reference Abada HT, Larchez C, Daoud B et al (2006) MDCT of the coronary arteries: feasibility of low-dose CT with ECG-pulsed tube current modulation to reduce radiation dose. AJR Am J Roentgenol 186(6 Suppl 2):S387–S390PubMedCrossRef Abada HT, Larchez C, Daoud B et al (2006) MDCT of the coronary arteries: feasibility of low-dose CT with ECG-pulsed tube current modulation to reduce radiation dose. AJR Am J Roentgenol 186(6 Suppl 2):S387–S390PubMedCrossRef
6.
go back to reference Fujioka C, Horiguchi J, Kiguchi M et al (2009) Survey of aorta and coronary arteries with prospective ECG-triggered 100-kV 64-MDCT angiography. AJR Am J Roentgenol 193(1):227–233PubMedCrossRef Fujioka C, Horiguchi J, Kiguchi M et al (2009) Survey of aorta and coronary arteries with prospective ECG-triggered 100-kV 64-MDCT angiography. AJR Am J Roentgenol 193(1):227–233PubMedCrossRef
7.
go back to reference Leschka S, Stinn B, Schmid F et al (2009) Dual source CT coronary angiography in severely obese patients: trading off temporal resolution and image noise. Invest Radiol 44(11):720–727PubMedCrossRef Leschka S, Stinn B, Schmid F et al (2009) Dual source CT coronary angiography in severely obese patients: trading off temporal resolution and image noise. Invest Radiol 44(11):720–727PubMedCrossRef
8.
go back to reference Zanzonico P, Rothenberg LN, Strauss HW (2006) Radiation exposure of computed tomography and direct intracoronary angiography: risk has its reward. J Am Coll Cardiol 47(9):1846–1849PubMedCrossRef Zanzonico P, Rothenberg LN, Strauss HW (2006) Radiation exposure of computed tomography and direct intracoronary angiography: risk has its reward. J Am Coll Cardiol 47(9):1846–1849PubMedCrossRef
9.
go back to reference Morin RL, Gerber TC, McCollough CH (2003) Radiation dose in computed tomography of the heart. Circulation 107(6):917–922PubMedCrossRef Morin RL, Gerber TC, McCollough CH (2003) Radiation dose in computed tomography of the heart. Circulation 107(6):917–922PubMedCrossRef
10.
go back to reference Das M, Mahnken AH, Muhlenbruch G et al (2005) Individually adapted examination protocols for reduction of radiation exposure for 16-MDCT chest examinations. AJR Am J Roentgenol 184(5):1437–1443PubMed Das M, Mahnken AH, Muhlenbruch G et al (2005) Individually adapted examination protocols for reduction of radiation exposure for 16-MDCT chest examinations. AJR Am J Roentgenol 184(5):1437–1443PubMed
11.
go back to reference Gamsu G, Held BT, Czum JM (2004) Reduced radiation for adult thoracic CT: a practical approach. J Thorac Imaging 19(2):93–97PubMedCrossRef Gamsu G, Held BT, Czum JM (2004) Reduced radiation for adult thoracic CT: a practical approach. J Thorac Imaging 19(2):93–97PubMedCrossRef
12.
go back to reference Tack D, De Maertelaer V, Gevenois PA (2003) Dose reduction in multidetector CT using attenuation-based online tube current modulation. AJR Am J Roentgenol 181(2):331–334PubMed Tack D, De Maertelaer V, Gevenois PA (2003) Dose reduction in multidetector CT using attenuation-based online tube current modulation. AJR Am J Roentgenol 181(2):331–334PubMed
13.
go back to reference Jung B, Mahnken AH, Stargardt A et al (2003) Individually weight-adapted examination protocol in retrospectively ECG-gated MSCT of the heart. Eur Radiol 13(12):2560–2566PubMedCrossRef Jung B, Mahnken AH, Stargardt A et al (2003) Individually weight-adapted examination protocol in retrospectively ECG-gated MSCT of the heart. Eur Radiol 13(12):2560–2566PubMedCrossRef
14.
go back to reference Paul JF, Wartski M, Caussin C, Sigal-Cinqualbre A, Lancelin B, Angel C, Dambrin G (2005) Late defect on delayed contrast-enhanced multi-detector row CT scans in the prediction of SPECT infarct size after reperfused acute myocardial infarction: initial experience. Radiology 236:485–489PubMedCrossRef Paul JF, Wartski M, Caussin C, Sigal-Cinqualbre A, Lancelin B, Angel C, Dambrin G (2005) Late defect on delayed contrast-enhanced multi-detector row CT scans in the prediction of SPECT infarct size after reperfused acute myocardial infarction: initial experience. Radiology 236:485–489PubMedCrossRef
15.
go back to reference Mahnken AH, Koos R, Katoh M, Wildberger JE, Spuentrup E, Buecker A, Gunther RW, Kuhl HP (2005) Assessment of myocardial viability in reperfused acute myocardial infarction using 16-slice computed tomography in comparison to magnetic resonance imaging. J Am Coll Cardiol 45:2042–2047PubMedCrossRef Mahnken AH, Koos R, Katoh M, Wildberger JE, Spuentrup E, Buecker A, Gunther RW, Kuhl HP (2005) Assessment of myocardial viability in reperfused acute myocardial infarction using 16-slice computed tomography in comparison to magnetic resonance imaging. J Am Coll Cardiol 45:2042–2047PubMedCrossRef
16.
go back to reference Brodoefel H, Klumpp B, Reimann A, Ohmer M, Fenchel M, Schroeder S, Miller S, Claussen C, Kopp AF, Scheule AM (2007) Late myocardial enhancement assessed by 64-MSCT in reperfused porcine myocardial infarction: diagnostic accuracy of low-dose CT protocols in comparison with magnetic resonance imaging. Eur Radiol 17(2):475–483PubMedCrossRef Brodoefel H, Klumpp B, Reimann A, Ohmer M, Fenchel M, Schroeder S, Miller S, Claussen C, Kopp AF, Scheule AM (2007) Late myocardial enhancement assessed by 64-MSCT in reperfused porcine myocardial infarction: diagnostic accuracy of low-dose CT protocols in comparison with magnetic resonance imaging. Eur Radiol 17(2):475–483PubMedCrossRef
17.
go back to reference d’Agostino AG, Remy-Jardin M, Khalil C et al (2006) Low-dose ECG-gated 64-slices helical CT angiography of the chest: evaluation of image quality in 105 patients. Eur Radiol 16(10):2137–2146PubMedCrossRef d’Agostino AG, Remy-Jardin M, Khalil C et al (2006) Low-dose ECG-gated 64-slices helical CT angiography of the chest: evaluation of image quality in 105 patients. Eur Radiol 16(10):2137–2146PubMedCrossRef
18.
go back to reference EC99 (1999) European guidelines on quality criteria for computed tomography. Report EUR 16262. European Commission, Brussels EC99 (1999) European guidelines on quality criteria for computed tomography. Report EUR 16262. European Commission, Brussels
19.
go back to reference Hausleiter J, Meyer T, Hadamitzky M et al (2006) Radiation dose estimates from cardiac multislice computed tomography in daily practice: impact of different scanning protocols on effective dose estimates. Circulation 113(10):1305–1310PubMedCrossRef Hausleiter J, Meyer T, Hadamitzky M et al (2006) Radiation dose estimates from cardiac multislice computed tomography in daily practice: impact of different scanning protocols on effective dose estimates. Circulation 113(10):1305–1310PubMedCrossRef
20.
go back to reference Poll LW, Cohnen M, Brachten S et al (2002) Dose reduction in multi-slice CT of the heart by use of ECG-controlled tube current modulation (“ECG pulsing”): phantom measurements. Rofo 174(12):1500–1505PubMedCrossRef Poll LW, Cohnen M, Brachten S et al (2002) Dose reduction in multi-slice CT of the heart by use of ECG-controlled tube current modulation (“ECG pulsing”): phantom measurements. Rofo 174(12):1500–1505PubMedCrossRef
21.
go back to reference Gerber TC, Kuzo RS, Morin RL (2005) Techniques and parameters for estimating radiation exposure and dose in cardiac computed tomography. Int J Cardiovasc Imaging 21(1):165–176PubMedCrossRef Gerber TC, Kuzo RS, Morin RL (2005) Techniques and parameters for estimating radiation exposure and dose in cardiac computed tomography. Int J Cardiovasc Imaging 21(1):165–176PubMedCrossRef
22.
go back to reference Trabold T, Buchgeister M, Kuttner A et al (2003) Estimation of radiation exposure in 16-detector row computed tomography of the heart with retrospective ECG-gating. Rofo 175(8):1051–1055PubMedCrossRef Trabold T, Buchgeister M, Kuttner A et al (2003) Estimation of radiation exposure in 16-detector row computed tomography of the heart with retrospective ECG-gating. Rofo 175(8):1051–1055PubMedCrossRef
23.
go back to reference Hunold P, Vogt FM, Schmermund A et al (2003) Radiation exposure during cardiac CT: effective doses at multi-detector row CT and electron-beam CT. Radiology 226(1):145–152PubMedCrossRef Hunold P, Vogt FM, Schmermund A et al (2003) Radiation exposure during cardiac CT: effective doses at multi-detector row CT and electron-beam CT. Radiology 226(1):145–152PubMedCrossRef
24.
go back to reference Coles DR, Smail MA, Negus IS et al (2006) Comparison of radiation doses from multislice computed tomography coronary angiography and conventional diagnostic angiography. J Am Coll Cardiol 47(9):1840–1845PubMedCrossRef Coles DR, Smail MA, Negus IS et al (2006) Comparison of radiation doses from multislice computed tomography coronary angiography and conventional diagnostic angiography. J Am Coll Cardiol 47(9):1840–1845PubMedCrossRef
Metadata
Title
Individually adapted coronary 64-slice CT angiography based on precontrast attenuation values, using different kVp and tube current settings: evaluation of image quality
Author
Jean-François Paul
Publication date
01-12-2011
Publisher
Springer Netherlands
Published in
The International Journal of Cardiovascular Imaging / Issue Special Issue 1/2011
Print ISSN: 1569-5794
Electronic ISSN: 1875-8312
DOI
https://doi.org/10.1007/s10554-011-9960-9

Other articles of this Special Issue 1/2011

The International Journal of Cardiovascular Imaging 1/2011 Go to the issue