Abstract

The standard protocol in multislice spiral CT (MSCT) angiography for coronary arteries with fixed tube current-time settings leads to an overexposure and thus to an unnecessary high radiation dose in patients with lower weight when compared to heavier patients. The purpose of this study was to estimate the effect of reducing the radiation dose by adapting the tube current-time settings individually. Fifty patients underwent retrospectively ECG-gated MSCT of the heart. In 25 patients (group A1) a standard protocol with constant tube current-time settings was used (4×1-mm collimation, 120 kV, 400 mAseff). Subsequently, artificial image noise was added to the data of these patients simulating a directive for weight-adapted tube current-time settings (group A2). In the other 25 patients (group B) an alternative protocol with individually weight-adapted tube current-time settings was applied. The data of all groups were evaluated by a regression analysis. The image quality was assessed objectively by measuring the CT attenuation in standardised regions of interest and subjectively by three radiologists using a five-point scoring system in a consensus reading. Applying the weight-adapted tube current-time settings the effective radiation dose was reduced by 17.9% for men and 26.3% for women. The standard protocol leads to an overexposure in light patients as seen in the plot of noise vs weight (slope 0.16±0.07 HU/kg). By applying the weight-adapted tube current-time settings a weight-independent, constant image noise is achieved (slope 0.04±0.1 HU/kg). Diagnostic image quality was preserved in all patients. Individually weight-adapted tube current-time settings allow for a substantial dose reduction when performing retrospectively ECG-gated MSCT angiography for coronary arteries without impairment of diagnostic image quality.
Literature
1.
go back to reference Schmidt T (2000) A few remarks on radiation exposure in CT. In: Nagel HD (ed) Radiation exposure in computed tomography. European Coordination committee on the radiological and electromedical industries (COCIR), Hamburg, pp 1–4 Schmidt T (2000) A few remarks on radiation exposure in CT. In: Nagel HD (ed) Radiation exposure in computed tomography. European Coordination committee on the radiological and electromedical industries (COCIR), Hamburg, pp 1–4
2.
go back to reference Kaul A, Bauer J, Bernhardt D, Nosske D, Veit R (1997) Effective doses to members of the public from the diagnostic application of the ionizing radiation in Germany. Eur Radiol 7:1127–1132CrossRefPubMed Kaul A, Bauer J, Bernhardt D, Nosske D, Veit R (1997) Effective doses to members of the public from the diagnostic application of the ionizing radiation in Germany. Eur Radiol 7:1127–1132CrossRefPubMed
3.
go back to reference Commission of the European Community (1998) Quality criteria for computed tomography. Working document EUR 16262. European Commission, Luxembourg Commission of the European Community (1998) Quality criteria for computed tomography. Working document EUR 16262. European Commission, Luxembourg
4.
go back to reference Kopp AF, Ohnesorge B, Flohr T, Georg C, Schroder S, Kuttner A, Martensen J, Claussen CD (2000) Cardiac multidetector-row CT: first clinical results of retrospectively ECG-gated spiral with optimized temporal and spatial resolution. Fortschr Röntgenstr 172:429–435 (in German) Kopp AF, Ohnesorge B, Flohr T, Georg C, Schroder S, Kuttner A, Martensen J, Claussen CD (2000) Cardiac multidetector-row CT: first clinical results of retrospectively ECG-gated spiral with optimized temporal and spatial resolution. Fortschr Röntgenstr 172:429–435 (in German)
5.
go back to reference Nieman K, Oudkerk M, Rensing BJ, van Ooijen P, Munne A, van Geuns RJ, de Feyter PJ (2001) Coronary angiography with multi-slice computed tomography. Lancet 357:599–603PubMed Nieman K, Oudkerk M, Rensing BJ, van Ooijen P, Munne A, van Geuns RJ, de Feyter PJ (2001) Coronary angiography with multi-slice computed tomography. Lancet 357:599–603PubMed
6.
go back to reference Achenbach S, Ulzheimer S, Baum U, Kachelriess M, Ropers D, Giesler T, Bautz W, Daniel WG, Kalender WA, Moshage W (2000) Noninvasive coronary angiography by retrospectively ECG-gated multislice spiral CT. Circulation 102:2823–2828PubMed Achenbach S, Ulzheimer S, Baum U, Kachelriess M, Ropers D, Giesler T, Bautz W, Daniel WG, Kalender WA, Moshage W (2000) Noninvasive coronary angiography by retrospectively ECG-gated multislice spiral CT. Circulation 102:2823–2828PubMed
7.
go back to reference Ohnesorge B, Flohr T, Becker C, Knez A, Knopp AF, Fukuda K, Reiser MF (2000) Cardiac imaging with rapid, retrospective ECG synchronized multilevel spiral CT. Radiologe 40:111–117 (in German)PubMed Ohnesorge B, Flohr T, Becker C, Knez A, Knopp AF, Fukuda K, Reiser MF (2000) Cardiac imaging with rapid, retrospective ECG synchronized multilevel spiral CT. Radiologe 40:111–117 (in German)PubMed
8.
go back to reference McCollough CH (2003) Patient dose in cardiac computed tomography. Herz 28:1–6PubMed McCollough CH (2003) Patient dose in cardiac computed tomography. Herz 28:1–6PubMed
9.
go back to reference Greess H, Nomayr A, Wolf H, Baum U, Lell M, Bowing B, Kalender W, Bautz WA (2002) Dose reduction in CT examination of children by an attenuation-based on-line modulation of tube current (CARE Dose). Eur Radiol 12:1571–1576PubMed Greess H, Nomayr A, Wolf H, Baum U, Lell M, Bowing B, Kalender W, Bautz WA (2002) Dose reduction in CT examination of children by an attenuation-based on-line modulation of tube current (CARE Dose). Eur Radiol 12:1571–1576PubMed
10.
go back to reference Jakobs TF, Becker CR, Ohnesorge B, Flohr T, Suess C, Schoepf UJ, Reiser MF (2002) Multislice helical CT of the heart with retrospective ECG gating: reduction of radiation exposure by ECG-controlled tube current modulation. Eur Radiol 12:1081–1086PubMed Jakobs TF, Becker CR, Ohnesorge B, Flohr T, Suess C, Schoepf UJ, Reiser MF (2002) Multislice helical CT of the heart with retrospective ECG gating: reduction of radiation exposure by ECG-controlled tube current modulation. Eur Radiol 12:1081–1086PubMed
11.
go back to reference Wildberger JE, Mahnken AH, Schmitz-Rode T, Flohr T, Stargardt A, Haage P, Schaller S, Günther RW (2001) Individually adapted examination protocols for reduction of radiation exposure in chest CT. Invest Radiol 36:604–611CrossRefPubMed Wildberger JE, Mahnken AH, Schmitz-Rode T, Flohr T, Stargardt A, Haage P, Schaller S, Günther RW (2001) Individually adapted examination protocols for reduction of radiation exposure in chest CT. Invest Radiol 36:604–611CrossRefPubMed
12.
go back to reference Donnelly LF, Emery KH, Brody AS, Laor T, Gylys-Morin VM, Anton CG, Thomas SR, Frush DP (2001) Minimizing radiation dose for pediatric body applications of single-detector helical CT: strategies at a large children’s hospital. Am J Roentgenol 176:303–306PubMed Donnelly LF, Emery KH, Brody AS, Laor T, Gylys-Morin VM, Anton CG, Thomas SR, Frush DP (2001) Minimizing radiation dose for pediatric body applications of single-detector helical CT: strategies at a large children’s hospital. Am J Roentgenol 176:303–306PubMed
13.
go back to reference Coppenrath E, Schmid C, Brandl R, Szeimis U, Hahn K (2001) Spiral CT of the abdomen: weight-adjusted dose reduction. Fortschr Röntgenstr 173:52–56 (in German) Coppenrath E, Schmid C, Brandl R, Szeimis U, Hahn K (2001) Spiral CT of the abdomen: weight-adjusted dose reduction. Fortschr Röntgenstr 173:52–56 (in German)
14.
go back to reference Greess H, Wolf H, Baum U, Lell M, Pirkl M, Kalender W, Bautz WA (2000) Dose reduction in computed tomography by attenuation-based on-line modulation of tube current: evaluation of six anatomical regions. Eur Radiol 10:391–394PubMed Greess H, Wolf H, Baum U, Lell M, Pirkl M, Kalender W, Bautz WA (2000) Dose reduction in computed tomography by attenuation-based on-line modulation of tube current: evaluation of six anatomical regions. Eur Radiol 10:391–394PubMed
15.
go back to reference Mahnken AH, Wildberger JE, Simon J, Koos R, Flohr TG, Schaller S, Günther RW (2003) Detection of coronary calcifications: feasibility of dose reduction with a body weight-adapted examination protocol. Am J Roentgenol 181:533–538 Mahnken AH, Wildberger JE, Simon J, Koos R, Flohr TG, Schaller S, Günther RW (2003) Detection of coronary calcifications: feasibility of dose reduction with a body weight-adapted examination protocol. Am J Roentgenol 181:533–538
16.
go back to reference Poll LW, Cohnen M, Brachten S, Ewen K, Modder U (2002) Dose reduction in multi-slice CT of the heart by use of ECG-controlled tube current modulation (“ECG pulsing”): phantom measurements. Fortschr Röntgenstr 174:1500–1505 (in German) Poll LW, Cohnen M, Brachten S, Ewen K, Modder U (2002) Dose reduction in multi-slice CT of the heart by use of ECG-controlled tube current modulation (“ECG pulsing”): phantom measurements. Fortschr Röntgenstr 174:1500–1505 (in German)
17.
go back to reference Flohr T, Ohnesorge B (2001) Heart rate adaptive optimization of spatial and temporal resolution for electrocardiogram-gated multislice spiral CT of the heart. J Comput Assist Tomogr 25:907–923CrossRefPubMed Flohr T, Ohnesorge B (2001) Heart rate adaptive optimization of spatial and temporal resolution for electrocardiogram-gated multislice spiral CT of the heart. J Comput Assist Tomogr 25:907–923CrossRefPubMed
18.
go back to reference Siemens Inc. (2001) SOMATOM volume zoom application guide: special protocols. Software version A40. Siemens, Forchheim, p 28 Siemens Inc. (2001) SOMATOM volume zoom application guide: special protocols. Software version A40. Siemens, Forchheim, p 28
19.
go back to reference Frush DP, Slack CC, Hollingsworth CL, Bisset G, Donnelly LF, Hsieh J, Lavin-Wensell T, Mayo JR (2002) Computer-simulated radiation dose reduction for abdominal multidetector CT of pediatric patients. Am J Roentgenol 179:1107–1113 Frush DP, Slack CC, Hollingsworth CL, Bisset G, Donnelly LF, Hsieh J, Lavin-Wensell T, Mayo JR (2002) Computer-simulated radiation dose reduction for abdominal multidetector CT of pediatric patients. Am J Roentgenol 179:1107–1113
20.
go back to reference Kalender WA (2000) Computed tomography, 1st edn. Publicis MCD, Munich, pp 84–85 Kalender WA (2000) Computed tomography, 1st edn. Publicis MCD, Munich, pp 84–85
21.
go back to reference Kalender WA, Schmidt B, Zankl M, Schmidt M (1999) A PC program for estimating organ dose and effective dose values in computed tomography. Eur Radiol 9:552–562CrossRefPubMed Kalender WA, Schmidt B, Zankl M, Schmidt M (1999) A PC program for estimating organ dose and effective dose values in computed tomography. Eur Radiol 9:552–562CrossRefPubMed
22.
go back to reference Cohnen M, Poll L, Puttmann C, Ewen K, Modder U (2001) Radiation exposure in multi-slice CT of the heart. Fortschr Röntgenstr 173:295–299 Cohnen M, Poll L, Puttmann C, Ewen K, Modder U (2001) Radiation exposure in multi-slice CT of the heart. Fortschr Röntgenstr 173:295–299
23.
go back to reference Becker CR, Kleffel T, Crispin A, Knez A, Young J, Schoepf UJ, Haberl R, Reiser MF (2001) Coronary artery calcium measurement: agreement of multirow detector and electron-beam CT. Am J Roentgenol 176:1295–1298 Becker CR, Kleffel T, Crispin A, Knez A, Young J, Schoepf UJ, Haberl R, Reiser MF (2001) Coronary artery calcium measurement: agreement of multirow detector and electron-beam CT. Am J Roentgenol 176:1295–1298
24.
go back to reference Kopp AF, Kuttner A, Heuschmid M, Schroder S, Ohnesorge B, Claussen CD (2002) Multidetector-row CT cardiac imaging with 4 and 16 slices for coronary CTA and imaging of atherosclerotic plaques. Eur Radiol 12 (Suppl 2):S17–S24CrossRefPubMed Kopp AF, Kuttner A, Heuschmid M, Schroder S, Ohnesorge B, Claussen CD (2002) Multidetector-row CT cardiac imaging with 4 and 16 slices for coronary CTA and imaging of atherosclerotic plaques. Eur Radiol 12 (Suppl 2):S17–S24CrossRefPubMed
25.
go back to reference Knez A, Becker C, Ohnesorge B, Haberl R, Reiser M, Steinbeck G (2000) Noninvasive detection of coronary artery stenosis by multislice helical computed tomography. Circulation 101:E221–E222PubMed Knez A, Becker C, Ohnesorge B, Haberl R, Reiser M, Steinbeck G (2000) Noninvasive detection of coronary artery stenosis by multislice helical computed tomography. Circulation 101:E221–E222PubMed
26.
go back to reference Sevkurov A, Pratap A, Doss C, Jelnin V, Hoff JA, Kondos GT (2002) Electron-beam tomography imaging of coronary calcium: the effect of body mass index on radiologic noise. J Comput Assist Tomogr 26:592–597CrossRefPubMed Sevkurov A, Pratap A, Doss C, Jelnin V, Hoff JA, Kondos GT (2002) Electron-beam tomography imaging of coronary calcium: the effect of body mass index on radiologic noise. J Comput Assist Tomogr 26:592–597CrossRefPubMed
Metadata
Title
Individually weight-adapted examination protocol in retrospectively ECG-gated MSCT of the heart
Authors
B. Jung
A. H. Mahnken
A. Stargardt
J. Simon
T. G. Flohr
S. Schaller
R. Koos
R. W. Günther
J. E. Wildberger
Publication date
01-12-2003
Publisher
Springer-Verlag
Published in
European Radiology / Issue 12/2003
Print ISSN: 0938-7994
Electronic ISSN: 1432-1084
DOI
https://doi.org/10.1007/s00330-003-2111-5

Other articles of this Issue 12/2003

European Radiology 12/2003 Go to the issue