Skip to main content
Top
Published in: The International Journal of Cardiovascular Imaging 1/2010

01-02-2010 | Original Paper

Retrospective versus prospective ECG-gated dual-source CT in pediatric patients with congenital heart diseases: comparison of image quality and radiation dose

Authors: Kwang Nam Jin, Eun-Ah Park, Cheong-il Shin, Whal Lee, Jin Wook Chung, Jae Hyung Park

Published in: The International Journal of Cardiovascular Imaging | Special Issue 1/2010

Login to get access

Abstract

We wanted to compare the image quality and radiation dose of retrospective versus prospective ECG-gated dual-source CT imaging in pediatric patients with congenital heart diseases. We retrospectively evaluated 44 thorax CT images that were obtained using two different protocols (retrospective helical ECG-gated [n = 22] versus prospective non-helical ECG-triggering [n = 22]) in patients younger than 5 years. Two radiologists evaluated the image quality, using a 3- or 4-point scale, in terms of the degree of homogeneity of vascular enhancement, the stair-step artifacts, the subjective image noise and the overall subjective image quality. We compared the mean score of image quality, the frequency of marked stair-step artifact and the estimated radiation dose. The mean score of the homogeneity of vascular enhancement and the stair-step artifacts tended to be higher for the patients in the retrospective group than that for the patients in the prospective group, but this did not reach statistical significance. However, marked stair-step artifacts were significantly more frequent in the prospective scan group than that in the retrospective scan group (25.8 vs. 7.6%, respectively, P < 0.01). The mean scores for subjective image noise and the overall image quality were better in the retrospective group than those scores in the prospective group (P < 0.01). The mean estimated effective dose was higher for the retrospective ECG-gated helical scan than that for the prospective non-helical scan (0.79 vs. 0.21 mSv, respectively, P < 0.01). Retrospective ECG-gated helical dual-source CT using aggressive ECG pulsing can be obtained with an acceptable radiation dose and superior image quality, as compared to the prospective ECG-triggering technique, for the evaluation of congenital heart diseases in pediatric patients who are younger than 5 years old.
Literature
1.
go back to reference Hayabuchi Y, Mori K, Kitagawa T et al (2007) Accurate quantification of pulmonary artery diameter in patients with cyanotic congenital heart disease using multidetector-row computed tomography. Am Heart J 154(4):783–788CrossRefPubMed Hayabuchi Y, Mori K, Kitagawa T et al (2007) Accurate quantification of pulmonary artery diameter in patients with cyanotic congenital heart disease using multidetector-row computed tomography. Am Heart J 154(4):783–788CrossRefPubMed
2.
go back to reference Goo HW, Park IS, Ko JK et al (2005) Computed tomography for the diagnosis of congenital heart disease in pediatric and adult patients. Int J Cardiovasc Imaging 21(2–3):347–365CrossRefPubMed Goo HW, Park IS, Ko JK et al (2005) Computed tomography for the diagnosis of congenital heart disease in pediatric and adult patients. Int J Cardiovasc Imaging 21(2–3):347–365CrossRefPubMed
3.
go back to reference Greil GF, Schoebinger M, Kuettner A et al (2006) Imaging of aortopulmonary collateral arteries with high-resolution multidetector CT. Pediatr Radiol 36(6):502–509CrossRefPubMed Greil GF, Schoebinger M, Kuettner A et al (2006) Imaging of aortopulmonary collateral arteries with high-resolution multidetector CT. Pediatr Radiol 36(6):502–509CrossRefPubMed
4.
go back to reference Oztunc F, Baris S, Adaletli I et al (2009) Coronary events and anatomy after arterial switch operation for transposition of the great arteries: detection by 16-row multislice computed tomography angiography in pediatric patients. Cardiovasc Intervent Radiol 32(2):206–212CrossRefPubMed Oztunc F, Baris S, Adaletli I et al (2009) Coronary events and anatomy after arterial switch operation for transposition of the great arteries: detection by 16-row multislice computed tomography angiography in pediatric patients. Cardiovasc Intervent Radiol 32(2):206–212CrossRefPubMed
5.
go back to reference Wang XM, Wu LB, Sun C et al (2007) Clinical application of 64-slice spiral CT in the diagnosis of the Tetralogy of Fallot. Eur J Radiol 64(2):296–301CrossRefPubMed Wang XM, Wu LB, Sun C et al (2007) Clinical application of 64-slice spiral CT in the diagnosis of the Tetralogy of Fallot. Eur J Radiol 64(2):296–301CrossRefPubMed
6.
go back to reference Hollingsworth CL, Yoshizumi TT, Frush DP et al (2007) Pediatric cardiac-gated CT angiography: assessment of radiation dose. Am J Roentgenol 189(1):12–18CrossRef Hollingsworth CL, Yoshizumi TT, Frush DP et al (2007) Pediatric cardiac-gated CT angiography: assessment of radiation dose. Am J Roentgenol 189(1):12–18CrossRef
7.
go back to reference Hein F, Meyer T, Hadamitzky M et al (2009) Prospective ECG-triggered sequential scan protocol for coronary dual-source CT angiography: initial experience. Int J Cardiovasc Imaging 25(suppl 2):S231–S239CrossRef Hein F, Meyer T, Hadamitzky M et al (2009) Prospective ECG-triggered sequential scan protocol for coronary dual-source CT angiography: initial experience. Int J Cardiovasc Imaging 25(suppl 2):S231–S239CrossRef
8.
go back to reference Petersilka M, Bruder H, Krauss B et al (2008) Technical principles of dual source CT. Eur J Radiol 68(3):362–368CrossRefPubMed Petersilka M, Bruder H, Krauss B et al (2008) Technical principles of dual source CT. Eur J Radiol 68(3):362–368CrossRefPubMed
9.
go back to reference Stolzmann P, Scheffel H, Schertler T et al (2008) Radiation dose estimates in dual-source computed tomography coronary angiography. Eur Radiol 18(3):592–599CrossRefPubMed Stolzmann P, Scheffel H, Schertler T et al (2008) Radiation dose estimates in dual-source computed tomography coronary angiography. Eur Radiol 18(3):592–599CrossRefPubMed
11.
go back to reference Ben Saad M, Rohnean A, Sigal-Cinqualbre A et al (2009) Evaluation of image quality and radiation dose of thoracic and coronary dual-source CT in 110 infants with congenital heart disease. Pediatr Radiol 39(7):668–676CrossRefPubMed Ben Saad M, Rohnean A, Sigal-Cinqualbre A et al (2009) Evaluation of image quality and radiation dose of thoracic and coronary dual-source CT in 110 infants with congenital heart disease. Pediatr Radiol 39(7):668–676CrossRefPubMed
12.
go back to reference Kuettner A, Gehann B, Spolnik J et al (2009) Strategies for dose-optimized imaging in pediatric cardiac dual source CT. Rofo 181(4):339–348PubMed Kuettner A, Gehann B, Spolnik J et al (2009) Strategies for dose-optimized imaging in pediatric cardiac dual source CT. Rofo 181(4):339–348PubMed
13.
go back to reference Lerner CB, Frush DP, Boll DT (2008) Evaluation of a coronary-cameral fistula: benefits of coronary dual-source MDCT angiography in children. Pediatr Radiol 38(8):874–878CrossRefPubMed Lerner CB, Frush DP, Boll DT (2008) Evaluation of a coronary-cameral fistula: benefits of coronary dual-source MDCT angiography in children. Pediatr Radiol 38(8):874–878CrossRefPubMed
14.
go back to reference Landis JR, Koch GG (1977) The measurement of observer agreement for categorical data. Biometrics 33(1):159–174CrossRefPubMed Landis JR, Koch GG (1977) The measurement of observer agreement for categorical data. Biometrics 33(1):159–174CrossRefPubMed
15.
go back to reference Cademartiri F, Mollet NR, Runza G et al (2006) Improving diagnostic accuracy of MDCT coronary angiography in patients with mild heart rhythm irregularities using ECG editing. Am J Roentgenol 186(3):634–638CrossRef Cademartiri F, Mollet NR, Runza G et al (2006) Improving diagnostic accuracy of MDCT coronary angiography in patients with mild heart rhythm irregularities using ECG editing. Am J Roentgenol 186(3):634–638CrossRef
16.
go back to reference Hirai N, Horiguchi J, Fujioka C et al (2008) Prospective versus retrospective ECG-gated 64-detector coronary CT angiography: assessment of image quality, stenosis, and radiation dose. Radiology 248(2):424–430CrossRefPubMed Hirai N, Horiguchi J, Fujioka C et al (2008) Prospective versus retrospective ECG-gated 64-detector coronary CT angiography: assessment of image quality, stenosis, and radiation dose. Radiology 248(2):424–430CrossRefPubMed
17.
go back to reference Arnoldi E, Johnson TR, Rist C et al (2009) Adequate image quality with reduced radiation dose in prospectively triggered coronary CTA compared with retrospective techniques. Eur Radiol 19(9):2147–2155CrossRefPubMed Arnoldi E, Johnson TR, Rist C et al (2009) Adequate image quality with reduced radiation dose in prospectively triggered coronary CTA compared with retrospective techniques. Eur Radiol 19(9):2147–2155CrossRefPubMed
18.
go back to reference Stolzmann P, Leschka S, Scheffel H et al (2008) Dual-source CT in step-and-shoot mode: noninvasive coronary angiography with low radiation dose. Radiology 249(1):71–80CrossRefPubMed Stolzmann P, Leschka S, Scheffel H et al (2008) Dual-source CT in step-and-shoot mode: noninvasive coronary angiography with low radiation dose. Radiology 249(1):71–80CrossRefPubMed
19.
go back to reference McCollough CH, Primak AN, Saba O et al (2007) Dose performance of a 64-channel dual-source CT scanner. Radiology 243(3):775–784CrossRefPubMed McCollough CH, Primak AN, Saba O et al (2007) Dose performance of a 64-channel dual-source CT scanner. Radiology 243(3):775–784CrossRefPubMed
20.
go back to reference Herzog C, Mulvihill DM, Nguyen SA et al (2008) Pediatric cardiovascular CT angiography: radiation dose reduction using automatic anatomic tube current modulation. Am J Roentgenol 190(5):1232–1240CrossRef Herzog C, Mulvihill DM, Nguyen SA et al (2008) Pediatric cardiovascular CT angiography: radiation dose reduction using automatic anatomic tube current modulation. Am J Roentgenol 190(5):1232–1240CrossRef
21.
go back to reference Pages J, Buls N, Osteaux M (2003) CT doses in children: a multicentre study. Br J Radiol 76(911):803–811CrossRefPubMed Pages J, Buls N, Osteaux M (2003) CT doses in children: a multicentre study. Br J Radiol 76(911):803–811CrossRefPubMed
22.
go back to reference Poll LW, Cohnen M, Brachten S et al (2002) Dose reduction in multi-slice CT of the heart by use of ECG-controlled tube current modulation (“ECG pulsing”): phantom measurements. Rofo 174(12):1500–1505PubMed Poll LW, Cohnen M, Brachten S et al (2002) Dose reduction in multi-slice CT of the heart by use of ECG-controlled tube current modulation (“ECG pulsing”): phantom measurements. Rofo 174(12):1500–1505PubMed
Metadata
Title
Retrospective versus prospective ECG-gated dual-source CT in pediatric patients with congenital heart diseases: comparison of image quality and radiation dose
Authors
Kwang Nam Jin
Eun-Ah Park
Cheong-il Shin
Whal Lee
Jin Wook Chung
Jae Hyung Park
Publication date
01-02-2010
Publisher
Springer Netherlands
Published in
The International Journal of Cardiovascular Imaging / Issue Special Issue 1/2010
Print ISSN: 1569-5794
Electronic ISSN: 1875-8312
DOI
https://doi.org/10.1007/s10554-009-9579-2

Other articles of this Special Issue 1/2010

The International Journal of Cardiovascular Imaging 1/2010 Go to the issue