Purpose

To investigate the utility of selected pattern electroretinogram (PERG) parameters—including N95 amplitude and N95/P50 ratio, and a BL-N95 amplitude—in the analysis of visual function(s) and for predicting changes in retinal ganglion cell structures in traumatic optic neuropathy.

Study design

A retrospective, observational case series performed at a single center.

Methods

Forty-four eyes from 36 patients diagnosed with optic neuropathy were included. A BL-N95 amplitude was defined as the amplitude measured from baseline to the trough of N95. PERG and pattern visual evoked potential (pVEP) measures were acquired within 1 week after onset of optic neuropathies. To compare functional and anatomical changes, mean temporal peripapillary retinal nerve fiber layer (pRNFL) and average and minimum ganglion cell-inner plexiform layer (GC-IPL) thicknesses were measured using optical coherence tomography.

Results

Thirty-six patients (20 men, 16 women; mean age 37.5 ± 17.6 years) were evaluated. The BL-N95 amplitude was significantly smaller than the N95 amplitude (1.01 ± 0.56 μV and 2.45 ± 1.02 μV, respectively; p  < 0.0001). Both the N95 (r  = − 0.38, p  = 0.010) and BL-N95 r  = − 0.32, p  = 0.029) amplitudes were significantly correlated with visual acuity. Although P100 latency was not correlated with all PERG parameters, the N95 (r  = 0.32, p  = 0.032) and BL-N95 (r  = 0.41, p  = 0.005) amplitudes demonstrated a positive correlation with P100 amplitude in pVEP. PERG parameters, including the N95 and BL-N95 amplitudes, and N95/P50 ratio, were not correlated with pRNFL thickness in optical coherence tomography. Only the BL-N95 amplitude demonstrated a significant correlation with GC-IPL.

Conclusion

The BL-N95 amplitude―measured from baseline to the trough of N95―was valuable in the analysis of visual function(s) and for predicting changes in retinal ganglion cell structures in traumatic optic neuropathy.
Literature
2.
go back to reference Viswanathan S, Frishman LJ, Robson JG. The uniform field and pattern ERG in macaques with experimental glaucoma: removal of spiking activity. Invest Ophthalmol Vis Sci. 2000;41:2797–810.PubMed Viswanathan S, Frishman LJ, Robson JG. The uniform field and pattern ERG in macaques with experimental glaucoma: removal of spiking activity. Invest Ophthalmol Vis Sci. 2000;41:2797–810.PubMed
3.
go back to reference Bach M, Brigell MG, Hawlina M, Holder GE, Johnson MA, McCulloch DL, et al. ISCEV standard for clinical pattern electroretinography (PERG): 2012 update. Doc Ophthalmol. 2013;126:1–7.CrossRefPubMed Bach M, Brigell MG, Hawlina M, Holder GE, Johnson MA, McCulloch DL, et al. ISCEV standard for clinical pattern electroretinography (PERG): 2012 update. Doc Ophthalmol. 2013;126:1–7.CrossRefPubMed
4.
go back to reference Holder GE. Pattern electroretinography (PERG) and an integrated approach to visual pathway diagnosis. Prog Retinal Eye Res. 2001;20:531–61.CrossRef Holder GE. Pattern electroretinography (PERG) and an integrated approach to visual pathway diagnosis. Prog Retinal Eye Res. 2001;20:531–61.CrossRef
5.
go back to reference Odom JV, Bach M, Brigell M, Holder GE, McCulloch DL, Mizota A, et al. ISCEV standard for clinical visual evoked potentials: (2016 update). Doc Ophthalmol. 2016;133:1–9.CrossRefPubMed Odom JV, Bach M, Brigell M, Holder GE, McCulloch DL, Mizota A, et al. ISCEV standard for clinical visual evoked potentials: (2016 update). Doc Ophthalmol. 2016;133:1–9.CrossRefPubMed
6.
go back to reference Atilla H, Tekeli O, Ornek K, Batioglu F, Elhan AH, Eryilmaz T. Pattern electroretinography and visual evoked potentials in optic nerve diseases. J Clin Neurosci. 2006;13:55–9.CrossRefPubMed Atilla H, Tekeli O, Ornek K, Batioglu F, Elhan AH, Eryilmaz T. Pattern electroretinography and visual evoked potentials in optic nerve diseases. J Clin Neurosci. 2006;13:55–9.CrossRefPubMed
7.
go back to reference Holder GE. The incidence of abnormal pattern electroretinography in optic nerve demyelination. Electroencephalogr Clin Neurophysiol. 1991;78:18–26.CrossRefPubMed Holder GE. The incidence of abnormal pattern electroretinography in optic nerve demyelination. Electroencephalogr Clin Neurophysiol. 1991;78:18–26.CrossRefPubMed
8.
go back to reference Berninger TA, Heider W. Pattern electroretinograms in optic neuritis during the acute stage and after remission. Graefes Arch Clin Exp Ophthalmol. 1990;228:410–4.CrossRefPubMed Berninger TA, Heider W. Pattern electroretinograms in optic neuritis during the acute stage and after remission. Graefes Arch Clin Exp Ophthalmol. 1990;228:410–4.CrossRefPubMed
9.
go back to reference Lowitzsch K. Welt R [Pattern-reversal visual evoked potentials and electroretinography in the early diagnosis of chronic simple glaucoma]. EEG EMG Z Elektroenzephalogr Elektromyogr Verwandte Geb. 1991;22:217–23 in German.PubMed Lowitzsch K. Welt R [Pattern-reversal visual evoked potentials and electroretinography in the early diagnosis of chronic simple glaucoma]. EEG EMG Z Elektroenzephalogr Elektromyogr Verwandte Geb. 1991;22:217–23 in German.PubMed
10.
go back to reference Benedek K, Pálffy A, Bencsik K, Fejes I, Rajda C, Tuboly G, et al. Combined use of pattern electroretinography and pattern visual evoked potentials in neuroophthalmological practice. Ideggyl Sz. 2008;61:33–41 In Hungarian. Benedek K, Pálffy A, Bencsik K, Fejes I, Rajda C, Tuboly G, et al. Combined use of pattern electroretinography and pattern visual evoked potentials in neuroophthalmological practice. Ideggyl Sz. 2008;61:33–41 In Hungarian.
11.
go back to reference Ikejiri M, Adachi-Usami E, Mizota A, Tsuyama Y, Miyauchi O, Suehiro S. Pattern visual evoked potentials in traumatic optic neuropathy. Ophthalmologica. 2002;216:415–9.CrossRefPubMed Ikejiri M, Adachi-Usami E, Mizota A, Tsuyama Y, Miyauchi O, Suehiro S. Pattern visual evoked potentials in traumatic optic neuropathy. Ophthalmologica. 2002;216:415–9.CrossRefPubMed
12.
go back to reference Kanamori A, Nakamura M, Yamada Y, Negi A. Longitudinal study of retinal nerve fiber layer thickness and ganglion cell complex in traumatic optic neuropathy. Arch Ophthalmol. 2012;130:1067–9.CrossRefPubMed Kanamori A, Nakamura M, Yamada Y, Negi A. Longitudinal study of retinal nerve fiber layer thickness and ganglion cell complex in traumatic optic neuropathy. Arch Ophthalmol. 2012;130:1067–9.CrossRefPubMed
13.
go back to reference Yukita M, Machida S, Nishiguchi KM, Tsuda S, Yokoyama Y, Yasuda M, et al. Molecular, anatomical and functional changes in the retinal ganglion cells after optic nerve crush in mice. Doc Ophthalmol. 2015;130:149–56.CrossRefPubMed Yukita M, Machida S, Nishiguchi KM, Tsuda S, Yokoyama Y, Yasuda M, et al. Molecular, anatomical and functional changes in the retinal ganglion cells after optic nerve crush in mice. Doc Ophthalmol. 2015;130:149–56.CrossRefPubMed
15.
go back to reference Sehi M, Pinzon-Plazas M, Feuer WJ, Greenfield DS. Relationship between pattern electroretinogram, standard automated perimetry, and optic nerve structural assessments. J Glaucoma. 2009;18:608–17.CrossRefPubMedPubMedCentral Sehi M, Pinzon-Plazas M, Feuer WJ, Greenfield DS. Relationship between pattern electroretinogram, standard automated perimetry, and optic nerve structural assessments. J Glaucoma. 2009;18:608–17.CrossRefPubMedPubMedCentral
16.
go back to reference Bowd C, Tafreshi A, Zangwill LM, Medeiros FA, Sample PA, Weinreb RN. Pattern electroretinogram association with spectral domain-OCT structural measurements in glaucoma. Eye. 2011;25:224–32.CrossRefPubMed Bowd C, Tafreshi A, Zangwill LM, Medeiros FA, Sample PA, Weinreb RN. Pattern electroretinogram association with spectral domain-OCT structural measurements in glaucoma. Eye. 2011;25:224–32.CrossRefPubMed
17.
go back to reference Goyal JL, Ghosh B, Sangit V, Kumar S, Jain P, Veerwal V, et al. Pattern ERG in central serous retinopathy. Doc Ophthalmol. 2015;130:141–7.CrossRefPubMed Goyal JL, Ghosh B, Sangit V, Kumar S, Jain P, Veerwal V, et al. Pattern ERG in central serous retinopathy. Doc Ophthalmol. 2015;130:141–7.CrossRefPubMed
18.
go back to reference Berninger T, Arden GB. The Pattern Electroretinogram. In: Heckenlively JR, Arden GB, editors. Principles and practice of clinical electrophysiology of vision. Cambridge: MIT press; 2006. p. 291–300. Berninger T, Arden GB. The Pattern Electroretinogram. In: Heckenlively JR, Arden GB, editors. Principles and practice of clinical electrophysiology of vision. Cambridge: MIT press; 2006. p. 291–300.
Metadata
Title
Efficacy of N95 amplitude of pattern electroretinogram measured from baseline to N95 trough in the traumatic optic neuropathy
Authors
Kun Hae Kim
Ungsoo Samuel Kim
Publication date
01-05-2019
Publisher
Springer Japan
Published in
Japanese Journal of Ophthalmology / Issue 3/2019
Print ISSN: 0021-5155
Electronic ISSN: 1613-2246
DOI
https://doi.org/10.1007/s10384-019-00664-9

Other articles of this Issue 3/2019

Japanese Journal of Ophthalmology 3/2019 Go to the issue