Effects of corneal irregular astigmatism on visual acuity after conventional and femtosecond laser-assisted Descemet’s stripping automated endothelial keratoplasty

Authors: Daisuke Tomida, Takefumi Yamaguchi, Akiko Ogawa, Yumiko Hirayama, Seika Shimazaki-Den, Yoshiyuki Satake, Jun Shimazaki

Published in: Japanese Journal of Ophthalmology | Issue 4/2015

Login to get access

Abstract

Purpose

To compare short-term outcomes of Descemet’s stripping automated endothelial keratoplasty (DSAEK) using a graft prepared with either a femtosecond laser or a microkeratome.

Methods

Thirty-eight patients underwent DSAEK with grafts prepared with either a femtosecond laser (f-DSAEK; 21 eyes) or a microkeratome (m-DSAEK; 17 eyes). Visual acuity, endothelial cell density, regular astigmatism and irregular astigmatism were compared between the two groups preoperatively and at 1, 3, and 6 months post-operatively. Fourier analysis was conducted to calculate astigmatism of the anterior and posterior surfaces, and total cornea, using anterior segment optical coherence tomography (AS-OCT).

Results

Visual acuity (logMAR) improved from 1.20 ± 0.60 to 0.43 ± 0.25 after m-DSAEK (P < 0.001) and from 1.20 ± 0.57 to 0.77 ± 0.33 after f-DSAEK (P = 0.0028) at 6 months following DSAEK. Visual acuity after m-DSAEK was significantly better than after f-DSAEK at 1, 3, and 6 months (P < 0.05). AS-OCT corneal images revealed greater irregularities on the posterior surfaces of f-DSAEK grafts compared to m-DSAEK grafts. Irregular astigmatism of the total cornea and the posterior surface was significantly larger after f-DSAEK than after m-DSAEK, although there was no significant difference in irregular astigmatism of the anterior surface at 6 months. Postoperative visual acuity was significantly correlated with the postoperative irregular astigmatism of the total cornea (r = 0.6657 and P < 0.001) and the anterior (r = 0.416, P = 0.016) and posterior surfaces (r = 0.7046, P < 0.001).

Conclusions

Visual outcomes after f-DSAEK were poor compared to conventional m-DSAEK due to an increase in irregular astigmatism caused by posterior surface irregularities.
Literature
1.
go back to reference Price FW Jr., Price MO. Descemet’s stripping with endothelial keratoplasty in 50 eyes: a refractive neutral corneal transplant. J Refract Surg. 2005;21:339–45.PubMed Price FW Jr., Price MO. Descemet’s stripping with endothelial keratoplasty in 50 eyes: a refractive neutral corneal transplant. J Refract Surg. 2005;21:339–45.PubMed
2.
3.
go back to reference Koenig SB, Covert DJ, Dupps WJ Jr., Meisler DM. Visual acuity, refractive error, and endothelial cell density 6 months after Descemet stripping and automated endothelial keratoplasty (DSAEK). Cornea. 2007;26:670–4.PubMedCrossRef Koenig SB, Covert DJ, Dupps WJ Jr., Meisler DM. Visual acuity, refractive error, and endothelial cell density 6 months after Descemet stripping and automated endothelial keratoplasty (DSAEK). Cornea. 2007;26:670–4.PubMedCrossRef
4.
go back to reference Price MO, Gorovoy M, Price FW Jr., Benetz BA, Menegay HJ, Lass JH. Descemet’s stripping automated endothelial keratoplasty: three-year graft and endothelial cell survival compared to penetrating keratoplasty. Ophthalmology. 2013;120:246–51.PubMedCentralPubMedCrossRef Price MO, Gorovoy M, Price FW Jr., Benetz BA, Menegay HJ, Lass JH. Descemet’s stripping automated endothelial keratoplasty: three-year graft and endothelial cell survival compared to penetrating keratoplasty. Ophthalmology. 2013;120:246–51.PubMedCentralPubMedCrossRef
5.
go back to reference Li JY, Terry MA, Goshe J, Shamie N, Davis-Boozer D. Graft rejection after Descemet’s stripping automated endothelial keratoplasty: graft survival and endothelial cell loss. Ophthalmology. 2012;119:90–4.PubMedCrossRef Li JY, Terry MA, Goshe J, Shamie N, Davis-Boozer D. Graft rejection after Descemet’s stripping automated endothelial keratoplasty: graft survival and endothelial cell loss. Ophthalmology. 2012;119:90–4.PubMedCrossRef
6.
go back to reference Yamaguchi T, Negishi K, Yamaguchi K, Dogru M, Uchino Y, Shimmura S, et al. Comparison of anterior and posterior corneal surface irregularity in Descemet stripping automated endothelial keratoplasty and penetrating keratoplasty. Cornea. 2010;29:1086–90.PubMedCrossRef Yamaguchi T, Negishi K, Yamaguchi K, Dogru M, Uchino Y, Shimmura S, et al. Comparison of anterior and posterior corneal surface irregularity in Descemet stripping automated endothelial keratoplasty and penetrating keratoplasty. Cornea. 2010;29:1086–90.PubMedCrossRef
7.
go back to reference Patel SV, Baratz KH, Hodge DO, Maquire LJ, McLaren JW. The effect of corneal light scatter on vision after Descemet stripping with endothelial keratoplasty. Arch Ophthalmol. 2009;127:153–60.PubMedCrossRef Patel SV, Baratz KH, Hodge DO, Maquire LJ, McLaren JW. The effect of corneal light scatter on vision after Descemet stripping with endothelial keratoplasty. Arch Ophthalmol. 2009;127:153–60.PubMedCrossRef
8.
go back to reference Rudolph M, Laaser K, Bachmann BO, Cursiefen C, Epstein D, Kruse FE. Corneal higher-order aberrations after Descemet’s membrane endothelial keratoplasty. Ophthalmology. 2012;119:528–35.PubMedCrossRef Rudolph M, Laaser K, Bachmann BO, Cursiefen C, Epstein D, Kruse FE. Corneal higher-order aberrations after Descemet’s membrane endothelial keratoplasty. Ophthalmology. 2012;119:528–35.PubMedCrossRef
9.
go back to reference Yamaguchi T, Negishi K, Yamaguchi K, Murat D, Uchino Y, Shimmura S, et al. Effect of anterior and posterior corneal surface irregularity on vision after Descemet-stripping endothelial keratoplasty. J Cataract Refract Surg. 2009;35:688–94.PubMedCrossRef Yamaguchi T, Negishi K, Yamaguchi K, Murat D, Uchino Y, Shimmura S, et al. Effect of anterior and posterior corneal surface irregularity on vision after Descemet-stripping endothelial keratoplasty. J Cataract Refract Surg. 2009;35:688–94.PubMedCrossRef
10.
go back to reference Muftuoglu O, Prasher P, Bowman RW, McCulley JP, Mootha VV. Corneal higher-order aberrations after Descemet’s stripping automated endothelial keratoplasty. Ophthalmology. 2010;117:878–84.PubMedCrossRef Muftuoglu O, Prasher P, Bowman RW, McCulley JP, Mootha VV. Corneal higher-order aberrations after Descemet’s stripping automated endothelial keratoplasty. Ophthalmology. 2010;117:878–84.PubMedCrossRef
11.
go back to reference Uchino Y, Shimmura S, Yamaguchi T, Kawakita T, Matsumoto Y, Negishi K, et al. Comparison of corneal thickness and haze in DSAEK and penetrating keratoplasty. Cornea. 2011;30:287–90.PubMedCrossRef Uchino Y, Shimmura S, Yamaguchi T, Kawakita T, Matsumoto Y, Negishi K, et al. Comparison of corneal thickness and haze in DSAEK and penetrating keratoplasty. Cornea. 2011;30:287–90.PubMedCrossRef
12.
go back to reference Dubbelman M, Sicam VA, van der Heijde RG. The contribution of the posterior surface to the coma aberration of the human cornea. J Vis. 2007;7(10):1–8.CrossRef Dubbelman M, Sicam VA, van der Heijde RG. The contribution of the posterior surface to the coma aberration of the human cornea. J Vis. 2007;7(10):1–8.CrossRef
13.
go back to reference Yamaguchi T, Ohnuma K, Tomida D, Konomi K, Satake Y, Negishi K, et al. The contribution of the posterior surface to the corneal aberrations in eyes after keratoplasty. Invest Ophthalmol Vis Sci. 2011;52:6222–9.PubMedCrossRef Yamaguchi T, Ohnuma K, Tomida D, Konomi K, Satake Y, Negishi K, et al. The contribution of the posterior surface to the corneal aberrations in eyes after keratoplasty. Invest Ophthalmol Vis Sci. 2011;52:6222–9.PubMedCrossRef
14.
go back to reference Dickman MM, Cheng YY, Berendschot TT, van den Biggelaar FJ, Nuijts RM. Effects of graft thickness and asymmetry on visual gain and aberrations after Descemet stripping automated endothelial keratoplasty. JAMA Ophthalmol. 2013;131:737–44.PubMedCrossRef Dickman MM, Cheng YY, Berendschot TT, van den Biggelaar FJ, Nuijts RM. Effects of graft thickness and asymmetry on visual gain and aberrations after Descemet stripping automated endothelial keratoplasty. JAMA Ophthalmol. 2013;131:737–44.PubMedCrossRef
15.
go back to reference Kezirian GM, Stonecipher KG. Comparison of the IntraLase femtosecond laser and mechanical keratomes for laser in situ keratomileusis. J Cataract Refract Surg. 2004;30:804–11.PubMedCrossRef Kezirian GM, Stonecipher KG. Comparison of the IntraLase femtosecond laser and mechanical keratomes for laser in situ keratomileusis. J Cataract Refract Surg. 2004;30:804–11.PubMedCrossRef
16.
go back to reference Kubaloglu A, Sari ES, Cinar Y, Cingu K, Koytak K, Coskun E, et al. Comparison of mechanical and femtosecond laser tunnel creation for intrastromal corneal ring segment implantation in keratoconus: prospective randomized clinical trial. J Cataract Refract Surg. 2011;36:1556–61.CrossRef Kubaloglu A, Sari ES, Cinar Y, Cingu K, Koytak K, Coskun E, et al. Comparison of mechanical and femtosecond laser tunnel creation for intrastromal corneal ring segment implantation in keratoconus: prospective randomized clinical trial. J Cataract Refract Surg. 2011;36:1556–61.CrossRef
17.
go back to reference Shousha MA, Yoo SH, Kymionis GD, Ide T, Feuer W, Carp CL, et al. Long-term results of femtosecond laser-assisted sutureless anterior lamellar keratoplasty. Ophthalmology. 2011;118:315–23.PubMedCrossRef Shousha MA, Yoo SH, Kymionis GD, Ide T, Feuer W, Carp CL, et al. Long-term results of femtosecond laser-assisted sutureless anterior lamellar keratoplasty. Ophthalmology. 2011;118:315–23.PubMedCrossRef
18.
go back to reference Gaster RN, Dumitrascu O, Rabinowitz YS. Penetrating keratoplasty using femtosecond laser-enabled keratoplasty with zig-zag incisions versus a mechanical trephine in patients with keratoconus. Br J Ophthalmol. 2012;96:1195–9.PubMedCentralPubMedCrossRef Gaster RN, Dumitrascu O, Rabinowitz YS. Penetrating keratoplasty using femtosecond laser-enabled keratoplasty with zig-zag incisions versus a mechanical trephine in patients with keratoconus. Br J Ophthalmol. 2012;96:1195–9.PubMedCentralPubMedCrossRef
19.
go back to reference Shehadeh-Mashor R, Chan C, Yeung SN, Lichtinger A, Amiran M, Rootman DS. Long-term outcomes of femtosecond laser-assisted mushroom configuration deep anterior lamellar keratoplasty. Cornea. 2013;32:390–5.PubMedCrossRef Shehadeh-Mashor R, Chan C, Yeung SN, Lichtinger A, Amiran M, Rootman DS. Long-term outcomes of femtosecond laser-assisted mushroom configuration deep anterior lamellar keratoplasty. Cornea. 2013;32:390–5.PubMedCrossRef
20.
go back to reference Kymionis GD, Kontadakis GA, Grentzelos MA, Panagopoulou SI, Stojanovic N, Kankariya VP, et al. Thin-flap laser in situ keratomileusis with femtosecond-laser technology. J Cataract Refract Surg. 2013;39:1366–71.PubMedCrossRef Kymionis GD, Kontadakis GA, Grentzelos MA, Panagopoulou SI, Stojanovic N, Kankariya VP, et al. Thin-flap laser in situ keratomileusis with femtosecond-laser technology. J Cataract Refract Surg. 2013;39:1366–71.PubMedCrossRef
21.
go back to reference Cheng YY, Hendrikse F, Pels E, Widjh RJ, van Cleynenbreugel H, Eggink CA, et al. Preliminary results of femtosecond laser-assisted Descemet stripping endothelial keratoplasty. Arch Ophthalmol. 2008;126:1351–6.PubMedCrossRef Cheng YY, Hendrikse F, Pels E, Widjh RJ, van Cleynenbreugel H, Eggink CA, et al. Preliminary results of femtosecond laser-assisted Descemet stripping endothelial keratoplasty. Arch Ophthalmol. 2008;126:1351–6.PubMedCrossRef
22.
go back to reference Heinzelmann S, Maier P, Bohringer D, Auw-Hadrich C, Reinhard T. Visual outcome and histological findings following femtosecond laser-assisted versus microkeratome-assisted DSAEK. Graefes Arch Clin Exp Ophthalmol. 2013;251:1979–85.PubMedCrossRef Heinzelmann S, Maier P, Bohringer D, Auw-Hadrich C, Reinhard T. Visual outcome and histological findings following femtosecond laser-assisted versus microkeratome-assisted DSAEK. Graefes Arch Clin Exp Ophthalmol. 2013;251:1979–85.PubMedCrossRef
23.
go back to reference Kobayashi A, Yokogawa H, Sugiyama K. Descemet stripping with automated endothelial keratoplasty for bullous keratopathies secondary to argon laser iridotomy—preliminary results and usefulness of double-glide donor insertion technique. Cornea. 2008;27(Suppl 1):S62–9.PubMedCrossRef Kobayashi A, Yokogawa H, Sugiyama K. Descemet stripping with automated endothelial keratoplasty for bullous keratopathies secondary to argon laser iridotomy—preliminary results and usefulness of double-glide donor insertion technique. Cornea. 2008;27(Suppl 1):S62–9.PubMedCrossRef
24.
go back to reference Tanabe T, Tomidokoro A, Samejima T, Miyata K, Sato M, Kaji Y, et al. Corneal regular and irregular astigmatism assessed by Fourier analysis of videokeratography data in normal and pathologic eyes. Ophthalmology. 2004;111:752–7.PubMedCrossRef Tanabe T, Tomidokoro A, Samejima T, Miyata K, Sato M, Kaji Y, et al. Corneal regular and irregular astigmatism assessed by Fourier analysis of videokeratography data in normal and pathologic eyes. Ophthalmology. 2004;111:752–7.PubMedCrossRef
25.
go back to reference Cheng YY, van den Berg TJ, Schouten JS, Pels E, Wijdh RJ, van Cleynenbreugel H, et al. Quality of vision after femtosecond laser-assisted descemet stripping endothelial keratoplasty and penetrating keratoplasty: a randomized, multicenter clinical trial. Am J Ophthalmol. 2011;152:556–66.PubMedCrossRef Cheng YY, van den Berg TJ, Schouten JS, Pels E, Wijdh RJ, van Cleynenbreugel H, et al. Quality of vision after femtosecond laser-assisted descemet stripping endothelial keratoplasty and penetrating keratoplasty: a randomized, multicenter clinical trial. Am J Ophthalmol. 2011;152:556–66.PubMedCrossRef
26.
go back to reference Rosa AM, Silva MF, Quadrado MJ, Costa E, Margues I, Murta JN. Femtosecond laser and microkeratome-assisted Descemet stripping endothelial keratoplasty: first clinical results. Br J Ophthalmol. 2013;97:1104–7.PubMedCrossRef Rosa AM, Silva MF, Quadrado MJ, Costa E, Margues I, Murta JN. Femtosecond laser and microkeratome-assisted Descemet stripping endothelial keratoplasty: first clinical results. Br J Ophthalmol. 2013;97:1104–7.PubMedCrossRef
27.
go back to reference Vetter JM, Butsch C, Faust M, Schimidtmann I, Hoffmann EM, Sekundo W, et al. Irregularity of the posterior corneal surface after curved interface femtosecond laser-assisted versus microkeratome-assisted Descemet stripping automated endothelial keratoplasty. Cornea. 2013;32:118–24.PubMedCrossRef Vetter JM, Butsch C, Faust M, Schimidtmann I, Hoffmann EM, Sekundo W, et al. Irregularity of the posterior corneal surface after curved interface femtosecond laser-assisted versus microkeratome-assisted Descemet stripping automated endothelial keratoplasty. Cornea. 2013;32:118–24.PubMedCrossRef
28.
go back to reference Price MO, Price FW Jr. Descemet’s stripping with endothelial keratoplasty: comparative outcomes with microkeratome-dissected and manually dissected donor tissue. Ophthalmology. 2006;113:1936–42.PubMedCrossRef Price MO, Price FW Jr. Descemet’s stripping with endothelial keratoplasty: comparative outcomes with microkeratome-dissected and manually dissected donor tissue. Ophthalmology. 2006;113:1936–42.PubMedCrossRef
29.
go back to reference Dapena I, Ham L, Melles GR. Endothelial keratoplasty: DSEK/DSAEK or DMEK–the thinner the better? Curr Opin Ophthalmol. 2009;20:299–307.PubMedCrossRef Dapena I, Ham L, Melles GR. Endothelial keratoplasty: DSEK/DSAEK or DMEK–the thinner the better? Curr Opin Ophthalmol. 2009;20:299–307.PubMedCrossRef
30.
go back to reference Hayashi T, Hirayama Y, Yamada N, Shimazaki-Den S, Shimazaki J. Descemet stripping automated endothelial keratoplasty for bullous keratopathy with an irregular posterior surface. Cornea. 2013;32:1183–8.PubMedCrossRef Hayashi T, Hirayama Y, Yamada N, Shimazaki-Den S, Shimazaki J. Descemet stripping automated endothelial keratoplasty for bullous keratopathy with an irregular posterior surface. Cornea. 2013;32:1183–8.PubMedCrossRef
31.
go back to reference Mootha VV, Heck E, Verity SM, Lakshman N, Mufluoglu O, Bowman RW, et al. Comparative study of Descemet stripping automated endothelial keratoplasty donor preparation by Moria CBm microkeratome, Horizon microkeratome, and Intralase FS60. Cornea. 2011;30:320–4.PubMedCentralPubMed Mootha VV, Heck E, Verity SM, Lakshman N, Mufluoglu O, Bowman RW, et al. Comparative study of Descemet stripping automated endothelial keratoplasty donor preparation by Moria CBm microkeratome, Horizon microkeratome, and Intralase FS60. Cornea. 2011;30:320–4.PubMedCentralPubMed
32.
go back to reference Rossi M, Misto R, Gatto C, Garimoldi P, Campanelli M, D’Amato Thothova J. Protective effects of deswelling on stromal collagen denaturation after a corneal femtosecond laser cut. Invest Ophthalmol Vis Sci. 2013;54:4148–57.PubMedCrossRef Rossi M, Misto R, Gatto C, Garimoldi P, Campanelli M, D’Amato Thothova J. Protective effects of deswelling on stromal collagen denaturation after a corneal femtosecond laser cut. Invest Ophthalmol Vis Sci. 2013;54:4148–57.PubMedCrossRef
Metadata
Title
Effects of corneal irregular astigmatism on visual acuity after conventional and femtosecond laser-assisted Descemet’s stripping automated endothelial keratoplasty
Authors
Daisuke Tomida
Takefumi Yamaguchi
Akiko Ogawa
Yumiko Hirayama
Seika Shimazaki-Den
Yoshiyuki Satake
Jun Shimazaki
Publication date
01-07-2015
Publisher
Springer Japan
Published in
Japanese Journal of Ophthalmology / Issue 4/2015
Print ISSN: 0021-5155
Electronic ISSN: 1613-2246
DOI
https://doi.org/10.1007/s10384-015-0388-y

Other articles of this Issue 4/2015

Japanese Journal of Ophthalmology 4/2015 Go to the issue