Skip to main content
Top
Published in: Journal of Digital Imaging 3/2019

01-06-2019

Restoration of Full Data from Sparse Data in Low-Dose Chest Digital Tomosynthesis Using Deep Convolutional Neural Networks

Authors: Donghoon Lee, Hee-Joung Kim

Published in: Journal of Imaging Informatics in Medicine | Issue 3/2019

Login to get access

Abstract

Chest digital tomosynthesis (CDT) provides more limited image information required for diagnosis when compared to computed tomography. Moreover, the radiation dose received by patients is higher in CDT than in chest radiography. Thus, CDT has not been actively used in clinical practice. To increase the usefulness of CDT, the radiation dose should reduce to the level used in chest radiography. Given the trade-off between image quality and radiation dose in medical imaging, a strategy to generating high-quality images from limited data is need. We investigated a novel approach for acquiring low-dose CDT images based on learning-based algorithms, such as deep convolutional neural networks. We used both simulation and experimental imaging data and focused on restoring reconstructed images from sparse to full sampling data. We developed a deep learning model based on end-to-end image translation using U-net. We used 11 and 81 CDT reconstructed input and output images, respectively, to develop the model. To measure the radiation dose of the proposed method, we investigated effective doses using Monte Carlo simulations. The proposed deep learning model effectively restored images with degraded quality due to lack of sampling data. Quantitative evaluation using structure similarity index measure (SSIM) confirmed that SSIM was increased by approximately 20% when using the proposed method. The effective dose required when using sparse sampling data was approximately 0.11 mSv, similar to that used in chest radiography (0.1 mSv) based on a report by the Radiation Society of North America. We investigated a new approach for reconstructing tomosynthesis images using sparse projection data. The model-based iterative reconstruction method has previously been used for conventional sparse sampling reconstruction. However, model-based computing requires high computational power, which limits fast three-dimensional image reconstruction and thus clinical applicability. We expect that the proposed learning-based reconstruction strategy will generate images with excellent quality quickly and thus have the potential for clinical use.
Literature
1.
go back to reference Vikgren J, Zachrisson S, Svalkvist A, Johnsson AA, Boijsen M, Flinck A, Kheddache S, Båth M: Comparison of chest tomosynthesis and chest radiography for detection of pulmonary nodules: human observer study of clinical cases. Radiology 249:1031–1041, 2008CrossRef Vikgren J, Zachrisson S, Svalkvist A, Johnsson AA, Boijsen M, Flinck A, Kheddache S, Båth M: Comparison of chest tomosynthesis and chest radiography for detection of pulmonary nodules: human observer study of clinical cases. Radiology 249:1031–1041, 2008CrossRef
3.
go back to reference Tingberg A: X-ray tomosynthesis: a review of its use for breast and chest imaging. Radiat Prot Dosim 139:100–107, 2010CrossRef Tingberg A: X-ray tomosynthesis: a review of its use for breast and chest imaging. Radiat Prot Dosim 139:100–107, 2010CrossRef
4.
go back to reference Dobbins, III JT, McAdams HP, Godfrey JD, Li CM: Digital tomosynthesis of the chest. J Thorac Imaging 23:86–92, 2008CrossRefPubMed Dobbins, III JT, McAdams HP, Godfrey JD, Li CM: Digital tomosynthesis of the chest. J Thorac Imaging 23:86–92, 2008CrossRefPubMed
5.
go back to reference Katsura M, Matsuda I, Akahane M, Yasaka K, Hanaoka S, Akai H, Sato J, Kunimatsu A, Ohtomo K: Model-based iterative reconstruction technique for radiation dose reduction in chest CT: comparison with the adaptive statistical iterative reconstruction technique. Eur Radiol 22:1613–1623, 2012CrossRefPubMed Katsura M, Matsuda I, Akahane M, Yasaka K, Hanaoka S, Akai H, Sato J, Kunimatsu A, Ohtomo K: Model-based iterative reconstruction technique for radiation dose reduction in chest CT: comparison with the adaptive statistical iterative reconstruction technique. Eur Radiol 22:1613–1623, 2012CrossRefPubMed
6.
go back to reference Samei E, Ricahrd S: Assessment of the dose reduction potential of a model-based iterative reconstruction algorithm using a task-based performance metrology. Med Phys 41:314–323, 2015 Samei E, Ricahrd S: Assessment of the dose reduction potential of a model-based iterative reconstruction algorithm using a task-based performance metrology. Med Phys 41:314–323, 2015
7.
go back to reference Nishida J, Kitagawa K, Nagata M, Yamazaki A, Nagasawa N, Sakuma H: Model-based iterative reconstruction for multi-detector row CT assessment of the adamkiewicz artery. Radiology 270:282–291, 2014CrossRefPubMed Nishida J, Kitagawa K, Nagata M, Yamazaki A, Nagasawa N, Sakuma H: Model-based iterative reconstruction for multi-detector row CT assessment of the adamkiewicz artery. Radiology 270:282–291, 2014CrossRefPubMed
8.
go back to reference Xu L, Ren JSJ, Liu C, Jia J: Deep convolutional neural network for image deconvolution. Adv Neural Inf Proces Syst 27:1790–1798, 2014 Xu L, Ren JSJ, Liu C, Jia J: Deep convolutional neural network for image deconvolution. Adv Neural Inf Proces Syst 27:1790–1798, 2014
9.
go back to reference Han X: MR-based synthetic CT generation using a deep convolutional neural network method. Med Phys 44:1408–1419, 2017CrossRefPubMed Han X: MR-based synthetic CT generation using a deep convolutional neural network method. Med Phys 44:1408–1419, 2017CrossRefPubMed
10.
go back to reference Kang E, Min J, Ye JC: A deep convolutional neural network using directional wavelets for low-dose X-ray CT reconstruction. Med Phys 44:e360–e375, 2017CrossRefPubMed Kang E, Min J, Ye JC: A deep convolutional neural network using directional wavelets for low-dose X-ray CT reconstruction. Med Phys 44:e360–e375, 2017CrossRefPubMed
11.
go back to reference Giesteby L, Yang Q, Xi Y, Zhou Y, Zhang J, Wang G: Deep learning methods to guide CT image reconstruction and reduce metal artifacts, Proc Vol 10132 Med Imag. Phys of Med Imag 10132, 2017 Giesteby L, Yang Q, Xi Y, Zhou Y, Zhang J, Wang G: Deep learning methods to guide CT image reconstruction and reduce metal artifacts, Proc Vol 10132 Med Imag. Phys of Med Imag 10132, 2017
12.
go back to reference Dong C, Loy CC, He K, Tang X: Image super-resolution using deep convolutional networks. IEEE Trans Pattern Anal Mach Intell 38:295–307, 2015CrossRef Dong C, Loy CC, He K, Tang X: Image super-resolution using deep convolutional networks. IEEE Trans Pattern Anal Mach Intell 38:295–307, 2015CrossRef
13.
go back to reference Liu J, Zarshenas A, Qadir A, Wei Z, Yang L, Fajardo L, Suzuki K: Radiation dose reduction in digital breast tomosynthesis (DBT) by means of deep learning-based supervised image processing. Proc Vol 10574 Med Imag, Imag Process 10574, 2018 Liu J, Zarshenas A, Qadir A, Wei Z, Yang L, Fajardo L, Suzuki K: Radiation dose reduction in digital breast tomosynthesis (DBT) by means of deep learning-based supervised image processing. Proc Vol 10574 Med Imag, Imag Process 10574, 2018
15.
go back to reference Choi S, Lee S, Lee H, Lee D, Choi S, Shin J, Seo C-W, Kim H-J: Development of a prototype chest digital tomosynthesis (CDT) R/F system with fast image reconstruction using graphic processing unit (GPU) programming. Nucl Inst Methods Phys Res A 848:174–181, 2017CrossRef Choi S, Lee S, Lee H, Lee D, Choi S, Shin J, Seo C-W, Kim H-J: Development of a prototype chest digital tomosynthesis (CDT) R/F system with fast image reconstruction using graphic processing unit (GPU) programming. Nucl Inst Methods Phys Res A 848:174–181, 2017CrossRef
16.
go back to reference Lee D, Choi S, Lee H, Kim D, Choi S, Kim H-J: Quantitative evaluation of anatomical noise in chest digital tomosynthesis, digital radiography, and computed tomography. J Instrum 12:T04006, 2017CrossRef Lee D, Choi S, Lee H, Kim D, Choi S, Kim H-J: Quantitative evaluation of anatomical noise in chest digital tomosynthesis, digital radiography, and computed tomography. J Instrum 12:T04006, 2017CrossRef
17.
go back to reference Ronneberger O, Fischer P, Brox T: U-Net: Convolutional networks for biomedical image segmentation. Med Image Comput Comput Assist Interv 234–241, 2015 Ronneberger O, Fischer P, Brox T: U-Net: Convolutional networks for biomedical image segmentation. Med Image Comput Comput Assist Interv 234–241, 2015
19.
go back to reference Horé A, Ziou D: Image quality metrics: PSNR vs. SSIM. Int Conf Pattern Recog 2366–2369, 2010 Horé A, Ziou D: Image quality metrics: PSNR vs. SSIM. Int Conf Pattern Recog 2366–2369, 2010
20.
go back to reference Eskicioglu AM, Fisher PS: Image quality measures and their performance. IEEE Trans Commun 43:2959–2965, 1995CrossRef Eskicioglu AM, Fisher PS: Image quality measures and their performance. IEEE Trans Commun 43:2959–2965, 1995CrossRef
22.
go back to reference Khelassi-Toutaoui N, Berkani Y, Tsapaki V, Toutaoui AE, Merad A, Frahi-Amroun A, Brahimi Z: Experimental evaluation of PCXMC and prepare codes used in conventional radiology. Radiat Prot Dosim 131:374–378, 2008CrossRef Khelassi-Toutaoui N, Berkani Y, Tsapaki V, Toutaoui AE, Merad A, Frahi-Amroun A, Brahimi Z: Experimental evaluation of PCXMC and prepare codes used in conventional radiology. Radiat Prot Dosim 131:374–378, 2008CrossRef
23.
go back to reference Ladia A, Messaris G, Delis H, Panayiotakis G: Organ dose and risk assessment in paediatric radiography using the PCXMC 2.0. J Phys Conf Ser 637:012014, 2015CrossRef Ladia A, Messaris G, Delis H, Panayiotakis G: Organ dose and risk assessment in paediatric radiography using the PCXMC 2.0. J Phys Conf Ser 637:012014, 2015CrossRef
24.
go back to reference Sabol JM: A Monte Carlo estimation of effective dose in chest tomosynthesis. Med Phys 36:5480–5487, 2009CrossRefPubMed Sabol JM: A Monte Carlo estimation of effective dose in chest tomosynthesis. Med Phys 36:5480–5487, 2009CrossRefPubMed
25.
go back to reference Lee C, Park S, Lee JK: Specific absorbed fraction for Korean adult voxel phantom from internal photon source. Radiat Prot Dosim 123:360–368, 2007CrossRef Lee C, Park S, Lee JK: Specific absorbed fraction for Korean adult voxel phantom from internal photon source. Radiat Prot Dosim 123:360–368, 2007CrossRef
26.
go back to reference Sechopoluos I: A review of breast tomosynthesis. Part II. Image reconstruction, processing and analysis, and advanced applications. Med Phys 40:014302, 2013CrossRef Sechopoluos I: A review of breast tomosynthesis. Part II. Image reconstruction, processing and analysis, and advanced applications. Med Phys 40:014302, 2013CrossRef
27.
go back to reference Fahrig R, Dixon R, Payne T, Morin RL, Ganguly A, Strobel N: Dose and image quality for a cone-beam C-arm CT system. Med Phys 33:4541–4550, 2006CrossRefPubMed Fahrig R, Dixon R, Payne T, Morin RL, Ganguly A, Strobel N: Dose and image quality for a cone-beam C-arm CT system. Med Phys 33:4541–4550, 2006CrossRefPubMed
28.
go back to reference Goldman LW: Principles of CT: radiation dose and image quality. J Nucl Med Technol 35:213–225, 2007CrossRefPubMed Goldman LW: Principles of CT: radiation dose and image quality. J Nucl Med Technol 35:213–225, 2007CrossRefPubMed
29.
30.
go back to reference Abbas S, Lee T, Shin S, Lee R, Cho S: Effects of sparse sampling schemes on image quality in low-dose CT. Med Phys 40:111915, 2013CrossRefPubMed Abbas S, Lee T, Shin S, Lee R, Cho S: Effects of sparse sampling schemes on image quality in low-dose CT. Med Phys 40:111915, 2013CrossRefPubMed
31.
go back to reference Hara AK, Paden RG, Silva AC, Kujak JL, Lawder HJ, Pavlicek W: Iterative reconstruction technique for reducing body radiation dose at CT: feasibility study. AJR Am J Roentgenol 193:764–771, 2009CrossRefPubMed Hara AK, Paden RG, Silva AC, Kujak JL, Lawder HJ, Pavlicek W: Iterative reconstruction technique for reducing body radiation dose at CT: feasibility study. AJR Am J Roentgenol 193:764–771, 2009CrossRefPubMed
32.
go back to reference Beister M, Kolditz D, Kalender WA: Iterative reconstruction methods in X-ray CT. Phys Med 28:94–108, 2012CrossRefPubMed Beister M, Kolditz D, Kalender WA: Iterative reconstruction methods in X-ray CT. Phys Med 28:94–108, 2012CrossRefPubMed
Metadata
Title
Restoration of Full Data from Sparse Data in Low-Dose Chest Digital Tomosynthesis Using Deep Convolutional Neural Networks
Authors
Donghoon Lee
Hee-Joung Kim
Publication date
01-06-2019
Publisher
Springer International Publishing
Published in
Journal of Imaging Informatics in Medicine / Issue 3/2019
Print ISSN: 2948-2925
Electronic ISSN: 2948-2933
DOI
https://doi.org/10.1007/s10278-018-0124-5

Other articles of this Issue 3/2019

Journal of Digital Imaging 3/2019 Go to the issue