Skip to main content
Top
Published in: Journal of Digital Imaging 4/2013

01-08-2013

Impact of Voxel Size Variation on CBCT-Based Diagnostic Outcome in Dentistry: a Systematic Review

Authors: Rubens Spin-Neto, Erik Gotfredsen, Ann Wenzel

Published in: Journal of Imaging Informatics in Medicine | Issue 4/2013

Login to get access

Abstract

The objective of this study was to make a systematic review on the impact of voxel size in cone beam computed tomography (CBCT)-based image acquisition, retrieving evidence regarding the diagnostic outcome of those images. The MEDLINE bibliographic database was searched from 1950 to June 2012 for reports comparing diverse CBCT voxel sizes. The search strategy was limited to English-language publications using the following combined terms in the search strategy: (voxel or FOV or field of view or resolution) and (CBCT or cone beam CT). The results from the review identified 20 publications that qualitatively or quantitatively assessed the influence of voxel size on CBCT-based diagnostic outcome, and in which the methodology/results comprised at least one of the expected parameters (image acquisition, reconstruction protocols, type of diagnostic task, and presence of a gold standard). The diagnostic task assessed in the studies was diverse, including the detection of root fractures, the detection of caries lesions, and accuracy of 3D surface reconstruction and of bony measurements, among others. From the studies assessed, it is clear that no general protocol can be yet defined for CBCT examination of specific diagnostic tasks in dentistry. Rationale in this direction is an important step to define the utility of CBCT imaging.
Literature
1.
go back to reference Qu X, Li G, Zhang Z, Ma X: Detection accuracy of in vitro approximal caries by cone beam computed tomography images. Eur J Radiol 79:24–27, 2011CrossRef Qu X, Li G, Zhang Z, Ma X: Detection accuracy of in vitro approximal caries by cone beam computed tomography images. Eur J Radiol 79:24–27, 2011CrossRef
2.
go back to reference Scarfe WC, Farman AG, Levin MD, Gane D: Essentials of maxillofacial cone beam computed tomography. Alpha Omegan 103:62–67, 2010PubMedCrossRef Scarfe WC, Farman AG, Levin MD, Gane D: Essentials of maxillofacial cone beam computed tomography. Alpha Omegan 103:62–67, 2010PubMedCrossRef
3.
go back to reference Scarfe WC, Farman AG: What is cone-beam CT and how does it work? Dent Clin North Am 52:707–730, 2008PubMedCrossRef Scarfe WC, Farman AG: What is cone-beam CT and how does it work? Dent Clin North Am 52:707–730, 2008PubMedCrossRef
4.
go back to reference Grauer D, Cevidanes LS, Proffit WR: Working with DICOM craniofacial images. Am J Orthod Dentofacial Orthop 136:460–470, 2009PubMedCrossRef Grauer D, Cevidanes LS, Proffit WR: Working with DICOM craniofacial images. Am J Orthod Dentofacial Orthop 136:460–470, 2009PubMedCrossRef
5.
go back to reference Tsiklakis K, Donta C, Gavala S, Karayianni K, Kamenopoulou V, Hourdakis CJ: Dose reduction in maxillofacial imaging using low dose cone beam CT. Eur J Radiol 56:413–417, 2005PubMedCrossRef Tsiklakis K, Donta C, Gavala S, Karayianni K, Kamenopoulou V, Hourdakis CJ: Dose reduction in maxillofacial imaging using low dose cone beam CT. Eur J Radiol 56:413–417, 2005PubMedCrossRef
6.
go back to reference White SC, Pharoah MJ: The evolution and application of dental maxillofacial imaging modalities. Dent Clin North Am 52:689–705, 2008PubMedCrossRef White SC, Pharoah MJ: The evolution and application of dental maxillofacial imaging modalities. Dent Clin North Am 52:689–705, 2008PubMedCrossRef
7.
go back to reference Kamburoglu K, Murat S, Kolsuz E, Kurt H, Yuksel S, Paksoy C: Comparative assessment of subjective image quality of cross-sectional cone-beam computed tomography scans. J Oral Sci 53:501–508, 2011PubMedCrossRef Kamburoglu K, Murat S, Kolsuz E, Kurt H, Yuksel S, Paksoy C: Comparative assessment of subjective image quality of cross-sectional cone-beam computed tomography scans. J Oral Sci 53:501–508, 2011PubMedCrossRef
8.
go back to reference Hatcher DC: Operational principles for cone-beam computed tomography. J Am Dent Assoc 141:3–6, 2010 Hatcher DC: Operational principles for cone-beam computed tomography. J Am Dent Assoc 141:3–6, 2010
9.
go back to reference Palomo JM, Rao PS, Hans MG: Influence of CBCT exposure conditions on radiation dose. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 105:773–782, 2008PubMedCrossRef Palomo JM, Rao PS, Hans MG: Influence of CBCT exposure conditions on radiation dose. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 105:773–782, 2008PubMedCrossRef
10.
go back to reference Davies J, Johnson B, Drage N: Effective doses from cone beam CT investigation of the jaws. Dentomaxillofac Radiol 41:30–36, 2012PubMedCrossRef Davies J, Johnson B, Drage N: Effective doses from cone beam CT investigation of the jaws. Dentomaxillofac Radiol 41:30–36, 2012PubMedCrossRef
11.
go back to reference Patcas R, Muller L, Ullrich O, Peltomaki T: Accuracy of cone-beam computed tomography at different resolutions assessed on the bony covering of the mandibular anterior teeth. Am J Orthod Dentofacial Orthop 141:41–50, 2012PubMedCrossRef Patcas R, Muller L, Ullrich O, Peltomaki T: Accuracy of cone-beam computed tomography at different resolutions assessed on the bony covering of the mandibular anterior teeth. Am J Orthod Dentofacial Orthop 141:41–50, 2012PubMedCrossRef
12.
go back to reference Anderson SW, Soto JA: Multi-detector row CT of acute non-traumatic abdominal pain: contrast and protocol considerations. Radiol Clin North Am 50:137–147, 2012PubMedCrossRef Anderson SW, Soto JA: Multi-detector row CT of acute non-traumatic abdominal pain: contrast and protocol considerations. Radiol Clin North Am 50:137–147, 2012PubMedCrossRef
13.
go back to reference Miles KA: Perfusion CT for the assessment of tumour vascularity: which protocol. Br J Radiol 76:36–42, 2003CrossRef Miles KA: Perfusion CT for the assessment of tumour vascularity: which protocol. Br J Radiol 76:36–42, 2003CrossRef
14.
go back to reference Neves FS, Vasconcelos TV, Vaz SL, Freitas DQ, Haiter-Neto F: Evaluation of reconstructed images with different voxel sizes of acquisition in the diagnosis of simulated external root resorption using cone beam computed tomography. Int Endod J 45:234–239, 2012PubMedCrossRef Neves FS, Vasconcelos TV, Vaz SL, Freitas DQ, Haiter-Neto F: Evaluation of reconstructed images with different voxel sizes of acquisition in the diagnosis of simulated external root resorption using cone beam computed tomography. Int Endod J 45:234–239, 2012PubMedCrossRef
15.
go back to reference Hassan B, Couto Souza P, Jacobs R, de Azambuja Berti S, van der Stelt P: Influence of scanning and reconstruction parameters on quality of three-dimensional surface models of the dental arches from cone beam computed tomography. Clin Oral Investig 14:303–310, 2010PubMedCrossRef Hassan B, Couto Souza P, Jacobs R, de Azambuja Berti S, van der Stelt P: Influence of scanning and reconstruction parameters on quality of three-dimensional surface models of the dental arches from cone beam computed tomography. Clin Oral Investig 14:303–310, 2010PubMedCrossRef
16.
go back to reference Waltrick KB, de Abreu Junior MJ, Correa M, Zastrow MD, D'Avila Dutra V: Accuracy of linear measurements and visibility of the mandibular canal on cone-beam computed tomography images with different voxel sizes: an in vitro study. J Periodontol, 2012, doi:10.1902/jop.2012.110524 Waltrick KB, de Abreu Junior MJ, Correa M, Zastrow MD, D'Avila Dutra V: Accuracy of linear measurements and visibility of the mandibular canal on cone-beam computed tomography images with different voxel sizes: an in vitro study. J Periodontol, 2012, doi:10.​1902/​jop.​2012.​110524
17.
go back to reference Damstra J, Fourie Z, Huddleston Slater JJ, Ren Y: Accuracy of linear measurements from cone-beam computed tomography-derived surface models of different voxel sizes. Am J Orthod Dentofacial Orthop 137:16–17, 2010PubMedCrossRef Damstra J, Fourie Z, Huddleston Slater JJ, Ren Y: Accuracy of linear measurements from cone-beam computed tomography-derived surface models of different voxel sizes. Am J Orthod Dentofacial Orthop 137:16–17, 2010PubMedCrossRef
18.
go back to reference da Silveira PF, Vizzotto MB, Liedke GS, da Silveira HL, Montagner F, da Silveira HE: Detection of vertical root fractures by conventional radiographic examination and cone beam computed tomography—an in vitro analysis. Dent Traumatol, 2012, doi:10.1111/j.1600-9657.2012.01126.x da Silveira PF, Vizzotto MB, Liedke GS, da Silveira HL, Montagner F, da Silveira HE: Detection of vertical root fractures by conventional radiographic examination and cone beam computed tomography—an in vitro analysis. Dent Traumatol, 2012, doi:10.​1111/​j.​1600-9657.​2012.​01126.​x
19.
go back to reference Melo SL, Bortoluzzi EA, Abreu Jr, M, Correa LR, Correa M: Diagnostic ability of a cone-beam computed tomography scan to assess longitudinal root fractures in prosthetically treated teeth. J Endod 36:1879–1882, 2010PubMedCrossRef Melo SL, Bortoluzzi EA, Abreu Jr, M, Correa LR, Correa M: Diagnostic ability of a cone-beam computed tomography scan to assess longitudinal root fractures in prosthetically treated teeth. J Endod 36:1879–1882, 2010PubMedCrossRef
20.
go back to reference Ozer SY: Detection of vertical root fractures by using cone beam computed tomography with variable voxel sizes in an in vitro model. J Endod 37:75–79, 2011PubMedCrossRef Ozer SY: Detection of vertical root fractures by using cone beam computed tomography with variable voxel sizes in an in vitro model. J Endod 37:75–79, 2011PubMedCrossRef
21.
go back to reference Wenzel A, Haiter-Neto F, Frydenberg M, Kirkevang LL: Variable-resolution cone-beam computerized tomography with enhancement filtration compared with intraoral photostimulable phosphor radiography in detection of transverse root fractures in an in vitro model. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 108:939–945, 2009PubMedCrossRef Wenzel A, Haiter-Neto F, Frydenberg M, Kirkevang LL: Variable-resolution cone-beam computerized tomography with enhancement filtration compared with intraoral photostimulable phosphor radiography in detection of transverse root fractures in an in vitro model. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 108:939–945, 2009PubMedCrossRef
22.
go back to reference Dalili Z, Taramsari M, Mousavi Mehr SZ, Salamat F: Diagnostic value of two modes of cone-beam computed tomography in evaluation of simulated external root resorption: an in vitro study. Imaging Sci Dent 42:19–24, 2012PubMedCrossRef Dalili Z, Taramsari M, Mousavi Mehr SZ, Salamat F: Diagnostic value of two modes of cone-beam computed tomography in evaluation of simulated external root resorption: an in vitro study. Imaging Sci Dent 42:19–24, 2012PubMedCrossRef
23.
go back to reference Kamburoglu K, Kursun S: A comparison of the diagnostic accuracy of CBCT images of different voxel resolutions used to detect simulated small internal resorption cavities. Int Endod J 43:798–807, 2010PubMedCrossRef Kamburoglu K, Kursun S: A comparison of the diagnostic accuracy of CBCT images of different voxel resolutions used to detect simulated small internal resorption cavities. Int Endod J 43:798–807, 2010PubMedCrossRef
24.
go back to reference Liedke GS, da Silveira HE, da Silveira HL, Dutra V, de Figueiredo JA: Influence of voxel size in the diagnostic ability of cone beam tomography to evaluate simulated external root resorption. J Endod 35:233–235, 2009PubMedCrossRef Liedke GS, da Silveira HE, da Silveira HL, Dutra V, de Figueiredo JA: Influence of voxel size in the diagnostic ability of cone beam tomography to evaluate simulated external root resorption. J Endod 35:233–235, 2009PubMedCrossRef
25.
go back to reference Cheng JG, Zhang ZL, Wang XY, Zhang ZY, Ma XC, Li G: Detection accuracy of proximal caries by phosphor plate and cone-beam computerized tomography images scanned with different resolutions. Clin Oral Investig 16:1015–1021, 2011PubMedCrossRef Cheng JG, Zhang ZL, Wang XY, Zhang ZY, Ma XC, Li G: Detection accuracy of proximal caries by phosphor plate and cone-beam computerized tomography images scanned with different resolutions. Clin Oral Investig 16:1015–1021, 2011PubMedCrossRef
26.
go back to reference Haiter-Neto F, Wenzel A, Gotfredsen E: Diagnostic accuracy of cone beam computed tomography scans compared with intraoral image modalities for detection of caries lesions. Dentomaxillofac Radiol 37:18–22, 2008PubMedCrossRef Haiter-Neto F, Wenzel A, Gotfredsen E: Diagnostic accuracy of cone beam computed tomography scans compared with intraoral image modalities for detection of caries lesions. Dentomaxillofac Radiol 37:18–22, 2008PubMedCrossRef
27.
go back to reference Kamburoglu K, Murat S, Yuksel SP, Cebeci AR, Paksoy CS: Occlusal caries detection by using a cone-beam CT with different voxel resolutions and a digital intraoral sensor. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 109:63–69, 2010 Kamburoglu K, Murat S, Yuksel SP, Cebeci AR, Paksoy CS: Occlusal caries detection by using a cone-beam CT with different voxel resolutions and a digital intraoral sensor. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 109:63–69, 2010
28.
go back to reference Librizzi ZT, Tadinada AS, Valiyaparambil JV, Lurie AG, Mallya SM: Cone-beam computed tomography to detect erosions of the temporomandibular joint: effect of field of view and voxel size on diagnostic efficacy and effective dose. Am J Orthod Dentofacial Orthop 140:25–30, 2011CrossRef Librizzi ZT, Tadinada AS, Valiyaparambil JV, Lurie AG, Mallya SM: Cone-beam computed tomography to detect erosions of the temporomandibular joint: effect of field of view and voxel size on diagnostic efficacy and effective dose. Am J Orthod Dentofacial Orthop 140:25–30, 2011CrossRef
29.
go back to reference Bauman R, Scarfe W, Clark S, Morelli J, Scheetz J, Farman A: Ex vivo detection of mesiobuccal canals in maxillary molars using CBCT at four different isotropic voxel dimensions. Int Endod J 44:752–758, 2011PubMedCrossRef Bauman R, Scarfe W, Clark S, Morelli J, Scheetz J, Farman A: Ex vivo detection of mesiobuccal canals in maxillary molars using CBCT at four different isotropic voxel dimensions. Int Endod J 44:752–758, 2011PubMedCrossRef
30.
go back to reference Al-Rawi B, Hassan B, Vandenberge B, Jacobs R: Accuracy assessment of three-dimensional surface reconstructions of teeth from cone beam computed tomography scans. J Oral Rehabil 37:352–358, 2010PubMedCrossRef Al-Rawi B, Hassan B, Vandenberge B, Jacobs R: Accuracy assessment of three-dimensional surface reconstructions of teeth from cone beam computed tomography scans. J Oral Rehabil 37:352–358, 2010PubMedCrossRef
31.
go back to reference Maret D, et al: Effect of voxel size on accuracy of 3D reconstructions with cone beam CT. Dentomaxillofac Radiol 41:649–655, 2012PubMedCrossRef Maret D, et al: Effect of voxel size on accuracy of 3D reconstructions with cone beam CT. Dentomaxillofac Radiol 41:649–655, 2012PubMedCrossRef
32.
go back to reference Sun Z, Smith T, Kortam S, Kim DG, Tee BC, Fields H: Effect of bone thickness on alveolar bone-height measurements from cone-beam computed tomography images. Am J Orthod Dentofacial Orthop 139:117–127, 2011CrossRef Sun Z, Smith T, Kortam S, Kim DG, Tee BC, Fields H: Effect of bone thickness on alveolar bone-height measurements from cone-beam computed tomography images. Am J Orthod Dentofacial Orthop 139:117–127, 2011CrossRef
33.
go back to reference Torres MG, Campos PS, Segundo NP, Navarro M, Crusoe-Rebello I: Accuracy of linear measurements in cone beam computed tomography with different voxel sizes. Implant Dent 21:150–155, 2012PubMedCrossRef Torres MG, Campos PS, Segundo NP, Navarro M, Crusoe-Rebello I: Accuracy of linear measurements in cone beam computed tomography with different voxel sizes. Implant Dent 21:150–155, 2012PubMedCrossRef
34.
go back to reference Fourie Z, Damstra J, Gerrits PO, Ren Y: Accuracy and reliability of facial soft tissue depth measurements using cone beam computer tomography. Forensic Sci Int 199:9–14, 2010PubMedCrossRef Fourie Z, Damstra J, Gerrits PO, Ren Y: Accuracy and reliability of facial soft tissue depth measurements using cone beam computer tomography. Forensic Sci Int 199:9–14, 2010PubMedCrossRef
35.
go back to reference Sherrard JF, Rossouw PE, Benson BW, Carrillo R, Buschang PH: Accuracy and reliability of tooth and root lengths measured on cone-beam computed tomographs. Am J Orthod Dentofacial Orthop 137:100–108, 2010CrossRef Sherrard JF, Rossouw PE, Benson BW, Carrillo R, Buschang PH: Accuracy and reliability of tooth and root lengths measured on cone-beam computed tomographs. Am J Orthod Dentofacial Orthop 137:100–108, 2010CrossRef
36.
go back to reference Yeni YN, Christopherson GT, Dong XN, Kim DG, Fyhrie DP: Effect of microcomputed tomography voxel size on the finite element model accuracy for human cancellous bone. J Biomech Eng 127:1–8, 2005PubMedCrossRef Yeni YN, Christopherson GT, Dong XN, Kim DG, Fyhrie DP: Effect of microcomputed tomography voxel size on the finite element model accuracy for human cancellous bone. J Biomech Eng 127:1–8, 2005PubMedCrossRef
37.
go back to reference Chadwick JW, Lam EW: The effects of slice thickness and interslice interval on reconstructed cone beam computed tomographic images. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 110:e37–e42, 2010PubMed Chadwick JW, Lam EW: The effects of slice thickness and interslice interval on reconstructed cone beam computed tomographic images. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 110:e37–e42, 2010PubMed
38.
go back to reference Spin-Neto R, Marcantonio Jr, E, Gotfredsen E, Wenzel A: Exploring CBCT-based DICOM files. A systematic review on the properties of images used to evaluate maxillofacial bone grafts. J Digit Imaging 24:959–966, 2011PubMedCrossRef Spin-Neto R, Marcantonio Jr, E, Gotfredsen E, Wenzel A: Exploring CBCT-based DICOM files. A systematic review on the properties of images used to evaluate maxillofacial bone grafts. J Digit Imaging 24:959–966, 2011PubMedCrossRef
39.
go back to reference Ludlow JB, Davies-Ludlow LE, Brooks SL, Howerton WB: Dosimetry of 3 CBCT devices for oral and maxillofacial radiology: Cb Mercuray, Newtom 3G and i-Cat. Dentomaxillofac Radiol 35:219–226, 2006PubMedCrossRef Ludlow JB, Davies-Ludlow LE, Brooks SL, Howerton WB: Dosimetry of 3 CBCT devices for oral and maxillofacial radiology: Cb Mercuray, Newtom 3G and i-Cat. Dentomaxillofac Radiol 35:219–226, 2006PubMedCrossRef
40.
go back to reference Ballrick JW, Palomo JM, Ruch E, Amberman BD, Hans MG: Image distortion and spatial resolution of a commercially available cone-beam computed tomography machine. Am J Orthod Dentofacial Orthop 134:573–582, 2008PubMedCrossRef Ballrick JW, Palomo JM, Ruch E, Amberman BD, Hans MG: Image distortion and spatial resolution of a commercially available cone-beam computed tomography machine. Am J Orthod Dentofacial Orthop 134:573–582, 2008PubMedCrossRef
41.
go back to reference Leung CC, Palomo L, Griffith R, Hans MG: Accuracy and reliability of cone-beam computed tomography for measuring alveolar bone height and detecting bony dehiscences and fenestrations. Am J Orthod Dentofacial Orthop 137:109–119, 2010CrossRef Leung CC, Palomo L, Griffith R, Hans MG: Accuracy and reliability of cone-beam computed tomography for measuring alveolar bone height and detecting bony dehiscences and fenestrations. Am J Orthod Dentofacial Orthop 137:109–119, 2010CrossRef
42.
go back to reference Thomas RZ, Ruben JL, de Vries J, ten Bosch JJ, Huysmans MC: Transversal wavelength-independent microradiography, a method for monitoring caries lesions over time, validated with transversal microradiography. Caries Res 40:281–291, 2006PubMedCrossRef Thomas RZ, Ruben JL, de Vries J, ten Bosch JJ, Huysmans MC: Transversal wavelength-independent microradiography, a method for monitoring caries lesions over time, validated with transversal microradiography. Caries Res 40:281–291, 2006PubMedCrossRef
43.
go back to reference Hassan B, Metska ME, Ozok AR, van der Stelt P, Wesselink PR: Detection of vertical root fractures in endodontically treated teeth by a cone beam computed tomography scan. J Endod 35:719–722, 2009PubMedCrossRef Hassan B, Metska ME, Ozok AR, van der Stelt P, Wesselink PR: Detection of vertical root fractures in endodontically treated teeth by a cone beam computed tomography scan. J Endod 35:719–722, 2009PubMedCrossRef
44.
go back to reference Farman AG: ALARA still applies. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 100:395–397, 2005PubMedCrossRef Farman AG: ALARA still applies. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 100:395–397, 2005PubMedCrossRef
45.
go back to reference Hirsch E, Wolf U, Heinicke F, Silva MA: Dosimetry of the cone beam computed tomography Veraviewepocs 3D compared with the 3D Accuitomo in different fields of view. Dentomaxillofac Radiol 37:268–273, 2008PubMedCrossRef Hirsch E, Wolf U, Heinicke F, Silva MA: Dosimetry of the cone beam computed tomography Veraviewepocs 3D compared with the 3D Accuitomo in different fields of view. Dentomaxillofac Radiol 37:268–273, 2008PubMedCrossRef
Metadata
Title
Impact of Voxel Size Variation on CBCT-Based Diagnostic Outcome in Dentistry: a Systematic Review
Authors
Rubens Spin-Neto
Erik Gotfredsen
Ann Wenzel
Publication date
01-08-2013
Publisher
Springer US
Published in
Journal of Imaging Informatics in Medicine / Issue 4/2013
Print ISSN: 2948-2925
Electronic ISSN: 2948-2933
DOI
https://doi.org/10.1007/s10278-012-9562-7

Other articles of this Issue 4/2013

Journal of Digital Imaging 4/2013 Go to the issue