Excerpt
A 76-year-old man was admitted to our hospital for induction of hemodialysis due to advanced diabetic nephropathy. Since he had no permanent blood access, insertion of a temporary hemodialysis catheter was attempted at the right internal jugular vein. As the targeted vessel was easily confirmed by ultrasound, the initial puncture was not difficult. However, when the guiding wire was introduced, it did not advance beyond 10 cm from the puncture site. Venography was immediately performed, which showed narrowing and meandering of the central part of the internal jugular vein, which was hardly confirmed by ultrasound (Fig.
1). Finally, another temporary hemodialysis catheter was inserted at the right femoral vein. Today, ultrasound-guided method is the mainstay for internal jugular vein cannulation at bedside [