Skip to main content
Top
Published in: Hernia 1/2017

01-02-2017 | Original Article

Adhesion prevention in ventral hernia repair: an experimental study comparing three lightweight porous meshes recommended for intraperitoneal use

Authors: L. D’Amore, F. Ceci, S. Mattia, M. Fabbi, P. Negro, F. Gossetti

Published in: Hernia | Issue 1/2017

Login to get access

Abstract

Background

In ventral hernia repair, when prosthetic material is placed intraperitoneally, it may lead to an inflammatory reaction resulting in adhesions between the mesh and abdominal viscera. Several meshes have been developed to minimize this process. In this experimental study, the ability of different combined meshes to attenuate the adhesion formation was examined.

Methods

Three commercially available lightweight porous combined meshes were placed intraperitoneally to repair an abdominal wall defect in rats: DynaMesh-IPOM (PVDF + PP), TiMesh (titanium-coated filament PP) and C-QUR/FX (omega-3 fatty acid-coated filament PP). The DynaMesh-CICAT (PVDF) was implanted in the control group. Adhesion formation was macroscopically evaluated and scored after 7 and 21 days.

Results

All animals except two presented intra-abdominal adhesions. None of the meshes examined in the study demonstrated to prevent adhesions. C-QUR/FX reduced adhesion formation at 7 days’ follow-up compared with all other meshes but by 21 days this effect was diminished. Between 7 and 21 days adhesion extension significantly decreased for TiMesh. TAS did not show significant modifications between 7 and 21 days’ follow-up for each mesh.

Conclusions

The combined porous meshes tested in the present study demonstrated to reduce but not to prevent the adhesion formation, even if with some differences. Combined porous meshes could be chosen instead of simple meshes for retro-rectus preperitoneal prosthetic ventral hernia repair.
Literature
1.
go back to reference Conze J, Binnebosel M, Junge K, Schumpelick V (2010) Incisional hernia. How do I do it? Standard surgical approach. Chirurg 81:192–200CrossRefPubMed Conze J, Binnebosel M, Junge K, Schumpelick V (2010) Incisional hernia. How do I do it? Standard surgical approach. Chirurg 81:192–200CrossRefPubMed
2.
go back to reference Sauerland S, Walgenbach M, Habermalz B, Seiler CM, Miserez M (2011) Laparoscopic versus open surgical techniques for ventral or incisional hernia repair. Cochrane Database Syst Rev 16(3):CD007781 Sauerland S, Walgenbach M, Habermalz B, Seiler CM, Miserez M (2011) Laparoscopic versus open surgical techniques for ventral or incisional hernia repair. Cochrane Database Syst Rev 16(3):CD007781
3.
go back to reference Halm JA, de Wall LL, Steyerberg EW, Jeekel J, Lange JF (2007) Intraperitoneal polypropylene mesh hernia repair complicates subsequent abdominal surgery. World J Surg 31:423–429 (discussion 430) CrossRefPubMed Halm JA, de Wall LL, Steyerberg EW, Jeekel J, Lange JF (2007) Intraperitoneal polypropylene mesh hernia repair complicates subsequent abdominal surgery. World J Surg 31:423–429 (discussion 430) CrossRefPubMed
4.
go back to reference Coda A, Lamberti R, Martorana S (2012) Classification of prosthetics used in hernia repair based on weight and biomaterial. Hernia 1:15–21 Coda A, Lamberti R, Martorana S (2012) Classification of prosthetics used in hernia repair based on weight and biomaterial. Hernia 1:15–21
5.
go back to reference Robinson TN, Clarke JH, Schoen J, Walsh MD (2005) Major mesh-related complications following hernia repair: events reported to the Food and Drug Administration. Surg Endosc 19:1556–1560CrossRefPubMed Robinson TN, Clarke JH, Schoen J, Walsh MD (2005) Major mesh-related complications following hernia repair: events reported to the Food and Drug Administration. Surg Endosc 19:1556–1560CrossRefPubMed
6.
go back to reference Eriksen JR, Gogenur I, Rosenberg J (2007) Choice of mesh for laparoscopic ventral hernia repair. Hernia 11:481–492CrossRefPubMed Eriksen JR, Gogenur I, Rosenberg J (2007) Choice of mesh for laparoscopic ventral hernia repair. Hernia 11:481–492CrossRefPubMed
7.
go back to reference Gaertner WB, Bonsack ME, Delany JP (2010) Visceral adhesions to hernia prostheses. Hernia 14:375–381CrossRefPubMed Gaertner WB, Bonsack ME, Delany JP (2010) Visceral adhesions to hernia prostheses. Hernia 14:375–381CrossRefPubMed
8.
go back to reference Vogels RRM, van Barneveld KWY, Bosman JWAM, Bets G, Gijbels MJJ, Schreinemacher MHF, Bouvy ND (2015) Long-term evaluation of adhesion formation and foreign body response to three new meshes. Surg Endosc 29:2251–2259CrossRefPubMed Vogels RRM, van Barneveld KWY, Bosman JWAM, Bets G, Gijbels MJJ, Schreinemacher MHF, Bouvy ND (2015) Long-term evaluation of adhesion formation and foreign body response to three new meshes. Surg Endosc 29:2251–2259CrossRefPubMed
9.
go back to reference Dilege E, Coskun H, Gunduz B, Sakiz D, Mihmanli M (2006) Prevention of adhesion to prosthetic mesh in incisional ventral hernias: comparison of different barriers in an experimental model. Eur Surg Res 38:358–364CrossRefPubMed Dilege E, Coskun H, Gunduz B, Sakiz D, Mihmanli M (2006) Prevention of adhesion to prosthetic mesh in incisional ventral hernias: comparison of different barriers in an experimental model. Eur Surg Res 38:358–364CrossRefPubMed
10.
go back to reference Schreinemacher MHF, Emans PJ, Gijbels MJJ, Greve JWM, Beets GL, Bouvy ND (2009) Degradation of mesh coatings and intraperitoneal adhesion formation in an experimental model. Br J Surg 96:305–313CrossRefPubMed Schreinemacher MHF, Emans PJ, Gijbels MJJ, Greve JWM, Beets GL, Bouvy ND (2009) Degradation of mesh coatings and intraperitoneal adhesion formation in an experimental model. Br J Surg 96:305–313CrossRefPubMed
11.
go back to reference Konerding MA, Chanterau P, Delventhal V, Holste JL, Ackermann M (2012) Biomechanical and histologic evaluation of abdominal wall compliance with intraperitoneal onlay mesh implants in rabbits: a comparison of six different state-of-the-art meshes. Med Eng Phys 34:806–816CrossRefPubMed Konerding MA, Chanterau P, Delventhal V, Holste JL, Ackermann M (2012) Biomechanical and histologic evaluation of abdominal wall compliance with intraperitoneal onlay mesh implants in rabbits: a comparison of six different state-of-the-art meshes. Med Eng Phys 34:806–816CrossRefPubMed
12.
go back to reference Schreinemacher MHF, van Barneveld KWY, Dikmans REG, Gijbels MJJ, Greve JWM, Bouvy ND (2013) Coated meshes for hernia repair provide comparable intraperitoneal adhesion prevention. Surg Endosc 27:4202–4209CrossRefPubMed Schreinemacher MHF, van Barneveld KWY, Dikmans REG, Gijbels MJJ, Greve JWM, Bouvy ND (2013) Coated meshes for hernia repair provide comparable intraperitoneal adhesion prevention. Surg Endosc 27:4202–4209CrossRefPubMed
13.
go back to reference Klinge U, Klosterhalfen B (2012) Modified classification of surgical meshes for hernia repair based on the analyses of 1,000 explanted meshes. Hernia 16:251–258CrossRefPubMedPubMedCentral Klinge U, Klosterhalfen B (2012) Modified classification of surgical meshes for hernia repair based on the analyses of 1,000 explanted meshes. Hernia 16:251–258CrossRefPubMedPubMedCentral
14.
go back to reference Gaertner WB, Bonsack ME, Delaney JP (2007) Experimental evaluation of four biologic prostheses for ventral hernia repair. J Gastrointest Surg 11:1275–1285CrossRefPubMed Gaertner WB, Bonsack ME, Delaney JP (2007) Experimental evaluation of four biologic prostheses for ventral hernia repair. J Gastrointest Surg 11:1275–1285CrossRefPubMed
15.
go back to reference Garrard CL, Clement RH, Nannej L, Davidson JM, Richards WO (1999) Adhesion formation is reduced after laparoscopic surgery. Surg Endosc 13:10–13CrossRefPubMed Garrard CL, Clement RH, Nannej L, Davidson JM, Richards WO (1999) Adhesion formation is reduced after laparoscopic surgery. Surg Endosc 13:10–13CrossRefPubMed
16.
go back to reference Baptista ML, Bonsack ME, Felemovicious I, Delaney JP (2000) Abdominal adhesions to prosthetic mesh evaluated by laparoscopy and electron microscopy. J Am Coll Surg 190:271–280CrossRefPubMed Baptista ML, Bonsack ME, Felemovicious I, Delaney JP (2000) Abdominal adhesions to prosthetic mesh evaluated by laparoscopy and electron microscopy. J Am Coll Surg 190:271–280CrossRefPubMed
17.
go back to reference Matthews BD, Pratt BL, Backus CL, Kerche KW, Heniford BT (2002) Comparison of adhesion formation to the intra-abdominal mesh after laparoscopic adhesiolysis in the New Zealand white rabbit. Am Surg 68:936–940PubMed Matthews BD, Pratt BL, Backus CL, Kerche KW, Heniford BT (2002) Comparison of adhesion formation to the intra-abdominal mesh after laparoscopic adhesiolysis in the New Zealand white rabbit. Am Surg 68:936–940PubMed
18.
go back to reference Conze J, Junge K, Weiss C, Oettinger A, Schumpelick V (2008) New polymer for intra-abdominal meshes—PVDF copolymer. J Biomed Mater Res B Appl Biomater 87:321–328CrossRefPubMed Conze J, Junge K, Weiss C, Oettinger A, Schumpelick V (2008) New polymer for intra-abdominal meshes—PVDF copolymer. J Biomed Mater Res B Appl Biomater 87:321–328CrossRefPubMed
19.
go back to reference Scheidbach H, Tannapfel A, Schmidt U, Lippert H, Kockerling F (2004) Influence of titanium coating on the biocompatibility of a heavyweight polypropylene mesh. Eur Surg Res 36:313–317CrossRefPubMed Scheidbach H, Tannapfel A, Schmidt U, Lippert H, Kockerling F (2004) Influence of titanium coating on the biocompatibility of a heavyweight polypropylene mesh. Eur Surg Res 36:313–317CrossRefPubMed
20.
go back to reference Boutros C, Somasundar P, Razzak A, Helton S, Espat NJ (2010) Omega-3 fatty acids: investigations from cytokines regulation to pancreatic cancer gene suppression. Arch Surg 145:515–520CrossRefPubMed Boutros C, Somasundar P, Razzak A, Helton S, Espat NJ (2010) Omega-3 fatty acids: investigations from cytokines regulation to pancreatic cancer gene suppression. Arch Surg 145:515–520CrossRefPubMed
21.
go back to reference Junge K, Binnebosel M, Rosch R, Jansen M, Kammer D, Otto J, Schumpelick V, Klinge U (2009) Adhesion formation on polyvinylidenfluoride/polypropylene mesh for intra-abdominal placement in a rodent animal model. Surg Endosc 23:327–333CrossRefPubMed Junge K, Binnebosel M, Rosch R, Jansen M, Kammer D, Otto J, Schumpelick V, Klinge U (2009) Adhesion formation on polyvinylidenfluoride/polypropylene mesh for intra-abdominal placement in a rodent animal model. Surg Endosc 23:327–333CrossRefPubMed
22.
go back to reference Bellon JM, Jurado F, Garcia-Honduvilla N, Lopez R, Carrera-Sanmartin A, Bujan J (2002) The structure of a biomaterial rather than its chemical composition modulates the repair process at the peritoneal level. Am J Surg 184:154–159CrossRefPubMed Bellon JM, Jurado F, Garcia-Honduvilla N, Lopez R, Carrera-Sanmartin A, Bujan J (2002) The structure of a biomaterial rather than its chemical composition modulates the repair process at the peritoneal level. Am J Surg 184:154–159CrossRefPubMed
23.
go back to reference Pierce RA, Perrone JM, Nimeri A, Sexon JA, Walcutt J, Frisella M, Matthews BD (2009) 120-Day comparative analysis of adhesion grade and quality, mesh contraction and tissue response to a novel omega-3 fatty acid bioabsorbable barrier macroporous mesh after intraperitoneal placement. Surg Inn 16:45–54 Pierce RA, Perrone JM, Nimeri A, Sexon JA, Walcutt J, Frisella M, Matthews BD (2009) 120-Day comparative analysis of adhesion grade and quality, mesh contraction and tissue response to a novel omega-3 fatty acid bioabsorbable barrier macroporous mesh after intraperitoneal placement. Surg Inn 16:45–54
24.
go back to reference Schug-Pass C, Sommerer F, Tannapfel A, Lippert H, Kockerling R (2008) Does the additional application of a polylactide film (SurgiWrap) to a lightweight mesh (TiMesh) reduce adhesion after laparoscopic intraperitoneal implantation procedures? Experimental results obtained with the laparoscopic porcine model. Surg Endosc 22:2433–2439CrossRefPubMed Schug-Pass C, Sommerer F, Tannapfel A, Lippert H, Kockerling R (2008) Does the additional application of a polylactide film (SurgiWrap) to a lightweight mesh (TiMesh) reduce adhesion after laparoscopic intraperitoneal implantation procedures? Experimental results obtained with the laparoscopic porcine model. Surg Endosc 22:2433–2439CrossRefPubMed
25.
go back to reference Berger D, Bientzle M (2007) Laparoscopic repair of parastomal hernias: a single surgeon’s experience in 66 patients. Dis Colon Rectum 50:1668–1673CrossRefPubMed Berger D, Bientzle M (2007) Laparoscopic repair of parastomal hernias: a single surgeon’s experience in 66 patients. Dis Colon Rectum 50:1668–1673CrossRefPubMed
26.
go back to reference Berger D, Bientzle M (2009) Polyvinylidene fluoride: a suitable mesh material for laparoscopic incisional and parastomal hernia repair! A prospective, observational study with 344 patients. Hernia 13:167–172CrossRefPubMed Berger D, Bientzle M (2009) Polyvinylidene fluoride: a suitable mesh material for laparoscopic incisional and parastomal hernia repair! A prospective, observational study with 344 patients. Hernia 13:167–172CrossRefPubMed
27.
go back to reference Fortenly RH, Petter-Puchner AH, Glaser KS, Offner F, Benesch T, Rohr M (2010) Adverse effects of polyvinylidene fluoride-coated polypropylene mesh used for laparoscopic intraperitoneal onlay repair of incisional hernia. Br J Surg 97:1140–1145CrossRef Fortenly RH, Petter-Puchner AH, Glaser KS, Offner F, Benesch T, Rohr M (2010) Adverse effects of polyvinylidene fluoride-coated polypropylene mesh used for laparoscopic intraperitoneal onlay repair of incisional hernia. Br J Surg 97:1140–1145CrossRef
28.
go back to reference Klosterhalfen B (2011) Letter2: adverse effects of polyvinylidene fluoride-coated polypropylene mesh used for laparoscopic intraperitoneal onlay repair of incisional hernia. Br J Surg 98:159–160CrossRefPubMed Klosterhalfen B (2011) Letter2: adverse effects of polyvinylidene fluoride-coated polypropylene mesh used for laparoscopic intraperitoneal onlay repair of incisional hernia. Br J Surg 98:159–160CrossRefPubMed
29.
go back to reference Jamry A, Jalynski M, Piskorz L, Brocki M (2013) Assessment of adhesion formation after laparoscopic intraperitoneal implantation of Dynamesh IPOM mesh. Arch Med Sci 20:487–492CrossRef Jamry A, Jalynski M, Piskorz L, Brocki M (2013) Assessment of adhesion formation after laparoscopic intraperitoneal implantation of Dynamesh IPOM mesh. Arch Med Sci 20:487–492CrossRef
30.
go back to reference Sommer T, Friis-Andersen H (2013) DynaMesh in the repair of laparoscopic ventral hernia. A prospective study. Hernia 17:613–618CrossRefPubMed Sommer T, Friis-Andersen H (2013) DynaMesh in the repair of laparoscopic ventral hernia. A prospective study. Hernia 17:613–618CrossRefPubMed
Metadata
Title
Adhesion prevention in ventral hernia repair: an experimental study comparing three lightweight porous meshes recommended for intraperitoneal use
Authors
L. D’Amore
F. Ceci
S. Mattia
M. Fabbi
P. Negro
F. Gossetti
Publication date
01-02-2017
Publisher
Springer Paris
Published in
Hernia / Issue 1/2017
Print ISSN: 1265-4906
Electronic ISSN: 1248-9204
DOI
https://doi.org/10.1007/s10029-016-1541-3

Other articles of this Issue 1/2017

Hernia 1/2017 Go to the issue