Skip to main content
Top
Published in: Surgical Endoscopy 11/2008

01-11-2008

Does the additional application of a polylactide film (SurgiWrap) to a lightweight mesh (TiMesh) reduce adhesions after laparoscopic intraperitoneal implantation procedures? Experimental results obtained with the laparoscopic porcine model

Authors: Christine Schug-Paß, Florian Sommerer, Andrea Tannapfel, Hans Lippert, Ferdinand Köckerling

Published in: Surgical Endoscopy | Issue 11/2008

Login to get access

Abstract

Background

Intraperitoneal repair of incisional hernias using a mesh makes particular demands on the material used. In addition to good integration of the mesh on the parietal side, adhesions to the visceral peritoneum must be avoided. Large-pore, light-weight meshes induce fewer adhesions than heavy-weight polypropylene meshes. Although numerous adhesion-barrier substances for use in combination with a polypropylene mesh have been tested already, mostly in open small animal models, unequivocal benefits have been identified to date in only a few of the experiments.

Methods

Using the laparoscopic intraperitoneal onlay mesh technique, six pigs were implanted with either a lightweight polypropylene mesh (TiMesh light) or TiMesh plus an adhesion-barrier film made of polylactide (SurgiWrap). After 3 months, the animals underwent a postmortem laparoscopy, and specimens were obtained for planimetric and histologic investigations.

Results

No adhesions to intestinal structures were found in any of the animals. Adhesions between the greater omentum and the mesh did not differ significantly between the TiMesh (32%) and SurgiWrap (33.5%) groups. The shrinkage of the mesh’s surface area was comparable between the two groups (18% vs. 21%). Histology showed pronounced inflammatory reaction and bridging of scar tissue between the filaments with the use of SurgiWrap versus TiMesh light without film. However, immunohistochemical investigations examining the partial volume of the inflammatory cells, the proliferation marker Ki67, and the apoptotic index at the interface of the filaments all failed to show any significant differences.

Conclusion

To avoid adhesions, it is essential that the acute and chronic inflammatory reaction to the implanted material be as small as possible. This requirement is met specifically by the lightweight polypropylene mesh TiMesh light. The additional application of a slowly absorbable adhesion-barrier film made of polylactide (SurgiWrap) does not appear to confer any further benefit.
Literature
1.
go back to reference Alponat A, Lakshminarasappa SR, The M, Rajnakova A, Moochhala S, Goh PM, Chan ST (1997) Effects of physical barriers in prevention of adhesions: an incisional hernia model in rats. J Surg Res 68:126–132PubMedCrossRef Alponat A, Lakshminarasappa SR, The M, Rajnakova A, Moochhala S, Goh PM, Chan ST (1997) Effects of physical barriers in prevention of adhesions: an incisional hernia model in rats. J Surg Res 68:126–132PubMedCrossRef
2.
go back to reference Avital S, Bollinger TJ, Wilkinson JD, Marchetti F, Hellinger MD, Sands LR (2005) Preventing intraabdominal adhesions with polylactic acid film: an animal study. Dis Colon Rectum 48:153–157PubMedCrossRef Avital S, Bollinger TJ, Wilkinson JD, Marchetti F, Hellinger MD, Sands LR (2005) Preventing intraabdominal adhesions with polylactic acid film: an animal study. Dis Colon Rectum 48:153–157PubMedCrossRef
3.
go back to reference Baptista ML, Bonsack ME, Belaney JP (2000) Seprafilm reduces adhesions to polypropylene mesh. Surgery 128:86–92PubMedCrossRef Baptista ML, Bonsack ME, Belaney JP (2000) Seprafilm reduces adhesions to polypropylene mesh. Surgery 128:86–92PubMedCrossRef
4.
go back to reference Cobb WS, Burns JM, Peindl RD, Carbonell AM, Matthews BD, Kercher KW, Heniford BT (2006) Textile analysis of heavy weight, midweight, and lightweight polypropylene mesh in a porcine ventral hernia model. J Surg Res 136:1–7PubMedCrossRef Cobb WS, Burns JM, Peindl RD, Carbonell AM, Matthews BD, Kercher KW, Heniford BT (2006) Textile analysis of heavy weight, midweight, and lightweight polypropylene mesh in a porcine ventral hernia model. J Surg Res 136:1–7PubMedCrossRef
5.
go back to reference Conze J, Rosch R, Klinge U, Weiss C, Anurov M, Titkowa S, Oettinger A, Schumpelick V (2004) Polypropylene in the intraabdominal position: influence of pore size and surface area. Hernia 8:365–372PubMedCrossRef Conze J, Rosch R, Klinge U, Weiss C, Anurov M, Titkowa S, Oettinger A, Schumpelick V (2004) Polypropylene in the intraabdominal position: influence of pore size and surface area. Hernia 8:365–372PubMedCrossRef
6.
go back to reference Dinsmore RC, Calton WC, Harvey SB, Blaney MW (2000) Prevention of adhesions to polypropylene mesh in a traumatized bowel model. J Am Coll Surg 191:131–136PubMedCrossRef Dinsmore RC, Calton WC, Harvey SB, Blaney MW (2000) Prevention of adhesions to polypropylene mesh in a traumatized bowel model. J Am Coll Surg 191:131–136PubMedCrossRef
7.
go back to reference Felemovicius I, Bonsack ME, Hagerman G, Delaney JP (2004) Prevention of adhesions to polypropylene mesh. J Am Coll Surg 198:543–548PubMedCrossRef Felemovicius I, Bonsack ME, Hagerman G, Delaney JP (2004) Prevention of adhesions to polypropylene mesh. J Am Coll Surg 198:543–548PubMedCrossRef
8.
go back to reference Fitzgibbons RJ Jr, Salerno GM, Filipi CJ, Hunter WJ, Watson P (1994) A laparoscopic intraperitoneal onlay mesh technique for the repair of an indirect inguinal hernia. Ann Surg 219:144–156PubMedCrossRef Fitzgibbons RJ Jr, Salerno GM, Filipi CJ, Hunter WJ, Watson P (1994) A laparoscopic intraperitoneal onlay mesh technique for the repair of an indirect inguinal hernia. Ann Surg 219:144–156PubMedCrossRef
9.
go back to reference Garrard CL, Clemets RH, Nanney L, Davidson JM, Richards WO (1999) Adhesion formation is reduced after laparoscopic surgery. Surg Endosc 13:10–13PubMedCrossRef Garrard CL, Clemets RH, Nanney L, Davidson JM, Richards WO (1999) Adhesion formation is reduced after laparoscopic surgery. Surg Endosc 13:10–13PubMedCrossRef
10.
go back to reference Gonzalez R, Rodeheaver GT, Moody DL, Foresman PA, Ramshaw BJ (2004) Resistance to adhesion formation: a comparative study of treated and untreated mesh products placed in abdominal cavity. Hernia 8:213–219PubMedCrossRef Gonzalez R, Rodeheaver GT, Moody DL, Foresman PA, Ramshaw BJ (2004) Resistance to adhesion formation: a comparative study of treated and untreated mesh products placed in abdominal cavity. Hernia 8:213–219PubMedCrossRef
11.
go back to reference Greca FH, de Paula JB, Biondo-Simmoes ML, da Costa FD, da Silva AP, Times S, Mansur A (2001) The influence of differing pore sizes on biocompatibility of two polypropylene meshes in the repair of abdominal defects: experimental study in dogs. Hernia 5:59–64PubMedCrossRef Greca FH, de Paula JB, Biondo-Simmoes ML, da Costa FD, da Silva AP, Times S, Mansur A (2001) The influence of differing pore sizes on biocompatibility of two polypropylene meshes in the repair of abdominal defects: experimental study in dogs. Hernia 5:59–64PubMedCrossRef
12.
go back to reference Gutt CN, Oniu T, Mehrabi A, Büchler W (2004) Fewer adhesions induced by laparoscopic surgery? Surg Endosc 18:898–906PubMedCrossRef Gutt CN, Oniu T, Mehrabi A, Büchler W (2004) Fewer adhesions induced by laparoscopic surgery? Surg Endosc 18:898–906PubMedCrossRef
13.
go back to reference Iliopoulos J, Cornwall GB, Evans RO, Manganas C, Thomas KA, Newman DC, Walsh WR (2004) Evaluation of a bioabsorbable polylactide film in a large animal model for the reduction of retrosternal adhesions. J Surg Res 118:144–153PubMedCrossRef Iliopoulos J, Cornwall GB, Evans RO, Manganas C, Thomas KA, Newman DC, Walsh WR (2004) Evaluation of a bioabsorbable polylactide film in a large animal model for the reduction of retrosternal adhesions. J Surg Res 118:144–153PubMedCrossRef
14.
go back to reference Johnson EK, Hoyt CH, Dinsmore RC (2004) Abdominal wall hernia repair: a long-term comparison of Sepramesh and Dualmesh in a rabbit hernia model. Am Surg 70:657–661PubMed Johnson EK, Hoyt CH, Dinsmore RC (2004) Abdominal wall hernia repair: a long-term comparison of Sepramesh and Dualmesh in a rabbit hernia model. Am Surg 70:657–661PubMed
15.
go back to reference Junge K, Rosch R, Bialasinski L, Klinge U, Klosterhalfen B, Schumpelick V (2003) Persistent extracellular matrix remodelling at the interface to polymers used for hernia repair. Eur Surg Res 35:497–504PubMedCrossRef Junge K, Rosch R, Bialasinski L, Klinge U, Klosterhalfen B, Schumpelick V (2003) Persistent extracellular matrix remodelling at the interface to polymers used for hernia repair. Eur Surg Res 35:497–504PubMedCrossRef
16.
go back to reference Klinge U, Klosterhalfen B, Müller M, Öttinger AP, Schumpelick V (1998) Shrinking of polypropylene mesh in vivo: an experimental study in dogs. Eur J Surg 164:965–969PubMedCrossRef Klinge U, Klosterhalfen B, Müller M, Öttinger AP, Schumpelick V (1998) Shrinking of polypropylene mesh in vivo: an experimental study in dogs. Eur J Surg 164:965–969PubMedCrossRef
17.
go back to reference Klinge U, Klosterhalfen B, Birkenhauer V, Junge K, Conze J, Schumpelick V (2002) Impact of polymer pore size on interface scar formation in a rat model. J Surg Res 103:208–214PubMedCrossRef Klinge U, Klosterhalfen B, Birkenhauer V, Junge K, Conze J, Schumpelick V (2002) Impact of polymer pore size on interface scar formation in a rat model. J Surg Res 103:208–214PubMedCrossRef
18.
go back to reference Knook MT, van Rosmalen AC, Yoder BE, Kleinrensink GJ, Snijders CJ, Looman CWN, van Steensel CJ (2001) Optimal mesh size for endoscopic inguinal hernia repair: a study in a porcine model. Surg Endosc 15:1471–1477PubMedCrossRef Knook MT, van Rosmalen AC, Yoder BE, Kleinrensink GJ, Snijders CJ, Looman CWN, van Steensel CJ (2001) Optimal mesh size for endoscopic inguinal hernia repair: a study in a porcine model. Surg Endosc 15:1471–1477PubMedCrossRef
19.
go back to reference Kramer K, Senninger N, Hernst H, Probst W (2002) Effective prevention of adhesions with hyaluronate. Arch Surg 137:278–282PubMedCrossRef Kramer K, Senninger N, Hernst H, Probst W (2002) Effective prevention of adhesions with hyaluronate. Arch Surg 137:278–282PubMedCrossRef
20.
go back to reference Lam KH, Schakenraad JM, Esselbrugge H, Feijen J, Nieuwenhuis P (1993) The effect of phagocytosis of poly(L-lactid acid) fragments on cellular morphology and viability. J Biomed Mater Res 27:1569–1577PubMedCrossRef Lam KH, Schakenraad JM, Esselbrugge H, Feijen J, Nieuwenhuis P (1993) The effect of phagocytosis of poly(L-lactid acid) fragments on cellular morphology and viability. J Biomed Mater Res 27:1569–1577PubMedCrossRef
21.
go back to reference Matthews BD, Mostafa G, Carbonell AM, Joels CS, Kercher KW, Austin C, Norton HJ, Heniford BT (2005) Evaluation of adhesion formation and host tissue response to intraabdominal polytetrafluoroethylene mesh and composite prosthetic mesh. J Surg Res 123:227–234PubMedCrossRef Matthews BD, Mostafa G, Carbonell AM, Joels CS, Kercher KW, Austin C, Norton HJ, Heniford BT (2005) Evaluation of adhesion formation and host tissue response to intraabdominal polytetrafluoroethylene mesh and composite prosthetic mesh. J Surg Res 123:227–234PubMedCrossRef
22.
go back to reference Scheidbach H, Tamme C, Tannapfel A, Lippert H, Köckerling F (2004) In vivo studies comparing the biocompatibility of various polypropylene meshes and their handling properties during endoscopic total extraperitoneal (TEP) patchplasty. Surg Endosc 18:211–220PubMedCrossRef Scheidbach H, Tamme C, Tannapfel A, Lippert H, Köckerling F (2004) In vivo studies comparing the biocompatibility of various polypropylene meshes and their handling properties during endoscopic total extraperitoneal (TEP) patchplasty. Surg Endosc 18:211–220PubMedCrossRef
23.
go back to reference Scheidbach H, Tannapfel A, Schmidt U, Lippert H, Köckerling F (2004) Influence of titanium coating on the biocompatibility of a heavyweight polypropylene mesh. Eur Surg Res 36:313–317PubMedCrossRef Scheidbach H, Tannapfel A, Schmidt U, Lippert H, Köckerling F (2004) Influence of titanium coating on the biocompatibility of a heavyweight polypropylene mesh. Eur Surg Res 36:313–317PubMedCrossRef
24.
go back to reference Schug-Paß C, Tamme C, Tannapfel A, Köckerling F (2006) A lightweight polypropylene mesh (TiMesh) for laparoscopic intraperitoneal repair of abdominal wall hernias: comparison of biocompatibility with the DualMesh in an experimental study using the porcine model. Surg Endosc 20:402–409PubMedCrossRef Schug-Paß C, Tamme C, Tannapfel A, Köckerling F (2006) A lightweight polypropylene mesh (TiMesh) for laparoscopic intraperitoneal repair of abdominal wall hernias: comparison of biocompatibility with the DualMesh in an experimental study using the porcine model. Surg Endosc 20:402–409PubMedCrossRef
25.
go back to reference Tabata Y, Ikada Y (1988) Macrophage phagocytosis of biodegradable microspheres composed of L-lactic acid/glycolic acid homo- and copolymers. J Biomed Mater Res 22:837–858PubMedCrossRef Tabata Y, Ikada Y (1988) Macrophage phagocytosis of biodegradable microspheres composed of L-lactic acid/glycolic acid homo- and copolymers. J Biomed Mater Res 22:837–858PubMedCrossRef
26.
27.
go back to reference van´t Riet M, de Vos van Steenwijk PJ, Bonthuis F, Marquet RL, Steyerberg EW, Jeekel J, Bonjer HJ (2003) Prevention of adhesion to prosthetic mesh. Ann Surg 237:123–128CrossRef van´t Riet M, de Vos van Steenwijk PJ, Bonthuis F, Marquet RL, Steyerberg EW, Jeekel J, Bonjer HJ (2003) Prevention of adhesion to prosthetic mesh. Ann Surg 237:123–128CrossRef
28.
go back to reference van´t Riet M, Burger WA, Bonthuis F, Jeekel J, Bonjer HJ (2004) Prevention of adhesion formation to polypropylene mesh by collagen coating. Surg Endosc 18:681–685CrossRef van´t Riet M, Burger WA, Bonthuis F, Jeekel J, Bonjer HJ (2004) Prevention of adhesion formation to polypropylene mesh by collagen coating. Surg Endosc 18:681–685CrossRef
Metadata
Title
Does the additional application of a polylactide film (SurgiWrap) to a lightweight mesh (TiMesh) reduce adhesions after laparoscopic intraperitoneal implantation procedures? Experimental results obtained with the laparoscopic porcine model
Authors
Christine Schug-Paß
Florian Sommerer
Andrea Tannapfel
Hans Lippert
Ferdinand Köckerling
Publication date
01-11-2008
Publisher
Springer-Verlag
Published in
Surgical Endoscopy / Issue 11/2008
Print ISSN: 0930-2794
Electronic ISSN: 1432-2218
DOI
https://doi.org/10.1007/s00464-008-9876-1

Other articles of this Issue 11/2008

Surgical Endoscopy 11/2008 Go to the issue