Skip to main content
Top
Published in: Hernia 4/2013

01-08-2013 | Original Article

Lessons and challenges during a 5-year follow-up of 21 Composix Kugel implantations

Authors: A. Wiegering, N. Schlegel, C. Isbert, C. Jurowich, S. Doht, C. T. Germer, U. A. Dietz

Published in: Hernia | Issue 4/2013

Login to get access

Abstract

Introduction

From its introduction in 2000 until its US recall in December 2005, the Composix Kugel mesh was implanted in an estimated 350,000 patients worldwide. In our patients, minor postoperative complications were followed after a few years by more serious problems (persistent abdominal pain, infections, intestinal perforations). In this study, we take stock after a 5-year follow-up and issue a plea for improved product development strategies and the creation of hernia registries.

Patients and methods

Between 2003 and 2006, we implanted the Bard® Composix® Kugel® mesh in 21 patients (11 men, 10 women, mean age 63.2 ± 13.7 years) with incisional hernias using the open intraperitoneal onlay mesh technique. The mesh is made on one side of ePTFE and on the other of polypropylene and is expanded by a polyethylene (PET) memory recoil ring. The average follow-up was 45.5 months. All patients had at least one risk factor for hernia recurrence. Explanted prostheses were analyzed by scanning electron microscopy (SEM) and subjected to mechanical strength tests.

Results

During the postoperative course, six patients suffered a wound healing disorder. Ten patients complained of persistent abdominal wall pain and four experienced recurrence of the hernia. In one patient, the mesh had to be explanted due to chronic infection. In one patient, the PET memory recoil ring broke after 5 years of follow-up with consequent small bowel perforation. The PET memory recoil ring exhibited clear signs of degradation on SEM and unmistakable signs of material fatigue in a materials testing machine.

Conclusions

Patients with recalled Composix Kugel meshes face a singular risk for complications that may occur even many years after implantation. The most serious complication is the breakage of its PET memory recoil ring. Since the recall of the Composix Kugel Mesh, we have discontinued its use. It is necessary that future complications are documented in a common post-market surveillance registry. Algorithms need to be developed and promoted to support affected patients and surgeons.
Literature
1.
go back to reference Dietz UA, Hamelmann W, Winkler MS, Debus ES, Malafaia O, Czeczko NG, Thiede A, Kuhfuß I (2007) An alternative classification of incisional hernias enlisting morphology, body type and risk factors in the assessment of prognosis and tailoring of surgical technique. J Plast Reconstr Aesthet Surg 60(4):383–388PubMedCrossRef Dietz UA, Hamelmann W, Winkler MS, Debus ES, Malafaia O, Czeczko NG, Thiede A, Kuhfuß I (2007) An alternative classification of incisional hernias enlisting morphology, body type and risk factors in the assessment of prognosis and tailoring of surgical technique. J Plast Reconstr Aesthet Surg 60(4):383–388PubMedCrossRef
2.
go back to reference Dietz UA, Kuhfuss I, Debus ES et al (2006) Mario Donati and the vertical mattress suture of the skin. World J Surg 30:141–148PubMedCrossRef Dietz UA, Kuhfuss I, Debus ES et al (2006) Mario Donati and the vertical mattress suture of the skin. World J Surg 30:141–148PubMedCrossRef
3.
go back to reference Bringman S, Conze J, Cuccurullo D, Deprest J, Junge K, Klosterhalfen B, Parra-Davila E, Ramshaw B, Schumpelick V (2010) Hernia repair: the search for ideal meshes. Hernia 14(1):81–87PubMedCrossRef Bringman S, Conze J, Cuccurullo D, Deprest J, Junge K, Klosterhalfen B, Parra-Davila E, Ramshaw B, Schumpelick V (2010) Hernia repair: the search for ideal meshes. Hernia 14(1):81–87PubMedCrossRef
4.
go back to reference Hope WW, Iannitti DA (2009) An algorithm for managing patients who have Composix Kugel ventral hernia mesh. Hernia 13(5):475–479PubMedCrossRef Hope WW, Iannitti DA (2009) An algorithm for managing patients who have Composix Kugel ventral hernia mesh. Hernia 13(5):475–479PubMedCrossRef
5.
go back to reference Cobb WS, Harris JB, Lokey JS, McGill ES, Klove KL (2003) Incisional herniorrhaphy with intraperitoneal composite mesh: a report of 95 cases. Am Surg 69(9):784–787PubMed Cobb WS, Harris JB, Lokey JS, McGill ES, Klove KL (2003) Incisional herniorrhaphy with intraperitoneal composite mesh: a report of 95 cases. Am Surg 69(9):784–787PubMed
6.
go back to reference Cobb WS, Carbonell AM, Kalbaugh CL, Jones Y, Lokey JS (2009) Infection risk of open placement of intraperitoneal composite mesh. Am Surg 75(9):762–767PubMed Cobb WS, Carbonell AM, Kalbaugh CL, Jones Y, Lokey JS (2009) Infection risk of open placement of intraperitoneal composite mesh. Am Surg 75(9):762–767PubMed
7.
go back to reference Furukawa K, Taniai N, Suzuki H, Kiyama T, Nomura T, Takahashi T, Yoshiyuki T, Tajiri T (2005) Abdominal incisional hernia repair using the Composix Kugel patch: two case reports. J Nihon Med Sch 72(3):182–186CrossRef Furukawa K, Taniai N, Suzuki H, Kiyama T, Nomura T, Takahashi T, Yoshiyuki T, Tajiri T (2005) Abdominal incisional hernia repair using the Composix Kugel patch: two case reports. J Nihon Med Sch 72(3):182–186CrossRef
8.
go back to reference Iannitti DA, Hope WW, Norton HJ, Lincourt AE, Millikan K, Fenoglio ME, Moskowitz M (2008) Technique and outcomes of abdominal incisional hernia repair using a synthetic composite mesh: a report of 455 cases. J Am Coll Surg 206(1):83–88PubMedCrossRef Iannitti DA, Hope WW, Norton HJ, Lincourt AE, Millikan K, Fenoglio ME, Moskowitz M (2008) Technique and outcomes of abdominal incisional hernia repair using a synthetic composite mesh: a report of 455 cases. J Am Coll Surg 206(1):83–88PubMedCrossRef
9.
go back to reference Dietz UA, Winkler MS, Härtel RW, Fleischhacker A, Wiegering A, Isbert C, Jurowich C, Heuschmann P, Germer CT (2012) Importance of recurrence rating, morphology, hernial gap size, and risk factors in ventral and incisional hernia classification. Hernia (Epub ahead of print) Dietz UA, Winkler MS, Härtel RW, Fleischhacker A, Wiegering A, Isbert C, Jurowich C, Heuschmann P, Germer CT (2012) Importance of recurrence rating, morphology, hernial gap size, and risk factors in ventral and incisional hernia classification. Hernia (Epub ahead of print)
11.
go back to reference Liu FD, Li JY (2011) Surgical repair of the abdominal bulge using Composix Kugel patch with the intraperitoneal onlay mesh technique. Plast Reconstr Surg 128(2):103e–104ePubMedCrossRef Liu FD, Li JY (2011) Surgical repair of the abdominal bulge using Composix Kugel patch with the intraperitoneal onlay mesh technique. Plast Reconstr Surg 128(2):103e–104ePubMedCrossRef
12.
go back to reference Tsereteli Z, Ramshaw B, Ramaswamy A (2008) Chronic posterior seroma with neoperitoneum following laparoscopic ventral hernia repair: treatment algorithm. Hernia 12(4):363–366PubMedCrossRef Tsereteli Z, Ramshaw B, Ramaswamy A (2008) Chronic posterior seroma with neoperitoneum following laparoscopic ventral hernia repair: treatment algorithm. Hernia 12(4):363–366PubMedCrossRef
13.
go back to reference Robinson TN, Clarke JH, Schoen J, Walsh MD (2005) Major mesh-related complications following hernia repair: events reported to the Food and Drug Administration. Surg Endosc 19(12):1556–1560PubMedCrossRef Robinson TN, Clarke JH, Schoen J, Walsh MD (2005) Major mesh-related complications following hernia repair: events reported to the Food and Drug Administration. Surg Endosc 19(12):1556–1560PubMedCrossRef
15.
16.
go back to reference Hayami S, Hotta T, Takifuji K, Iwahashi M, Mitani Y, Yamaue H (2009) Reconstruction of an infected recurrent ventral hernia after a mesh repair using a pedicled tensor fascia lata flap: report of two cases. Surg Today 39(9):811–817PubMedCrossRef Hayami S, Hotta T, Takifuji K, Iwahashi M, Mitani Y, Yamaue H (2009) Reconstruction of an infected recurrent ventral hernia after a mesh repair using a pedicled tensor fascia lata flap: report of two cases. Surg Today 39(9):811–817PubMedCrossRef
17.
go back to reference Chelala E, Debardemaeker Y, Elias B, Charara F, Dessily M, Allé JL (2010) Eighty-five redo surgeries after 733 laparoscopic treatments for ventral and incisional hernia: adhesion and recurrence analysis. Hernia 14(2):123–129PubMedCrossRef Chelala E, Debardemaeker Y, Elias B, Charara F, Dessily M, Allé JL (2010) Eighty-five redo surgeries after 733 laparoscopic treatments for ventral and incisional hernia: adhesion and recurrence analysis. Hernia 14(2):123–129PubMedCrossRef
18.
go back to reference LeBlanc KA, Whitaker JM (2002) Management of chronic postoperative pain following incisional hernia repair with Composix mesh: a report of two cases. Hernia 6(4):194–197PubMedCrossRef LeBlanc KA, Whitaker JM (2002) Management of chronic postoperative pain following incisional hernia repair with Composix mesh: a report of two cases. Hernia 6(4):194–197PubMedCrossRef
19.
go back to reference Muysoms FE, Bontinck J, Pletinckx P (2011) Complications of mesh devices for intraperitoneal umbilical hernia repair: a word of caution. Hernia 15(4):463–468PubMedCrossRef Muysoms FE, Bontinck J, Pletinckx P (2011) Complications of mesh devices for intraperitoneal umbilical hernia repair: a word of caution. Hernia 15(4):463–468PubMedCrossRef
20.
go back to reference Berrevoet F, Van den Bossche B, de Baerdemaeker L, de Hemptinne B (2010) Laparoscopic evaluation shows deficiencies in memory ring deployment during small ventral hernia repair. World J Surg 34(7):1710–1715PubMedCrossRef Berrevoet F, Van den Bossche B, de Baerdemaeker L, de Hemptinne B (2010) Laparoscopic evaluation shows deficiencies in memory ring deployment during small ventral hernia repair. World J Surg 34(7):1710–1715PubMedCrossRef
21.
go back to reference Cozad MJ, Grant DA, Bachman SL, Grant DN, Ramshaw BJ, Grant SA (2010) Materials characterization of explanted polypropylene, polyethylene terephthalate, and expanded polytetrafluoroethylene composites: spectral and thermal analysis. J Biomed Mater Res B Appl Biomater 94(2):455–462PubMed Cozad MJ, Grant DA, Bachman SL, Grant DN, Ramshaw BJ, Grant SA (2010) Materials characterization of explanted polypropylene, polyethylene terephthalate, and expanded polytetrafluoroethylene composites: spectral and thermal analysis. J Biomed Mater Res B Appl Biomater 94(2):455–462PubMed
22.
go back to reference Costello CR, Bachman SL, Grant SA, Cleveland DS, Loy TS, Ramshaw BJ (2007) Characterization of heavyweight and lightweight polypropylene prosthetic mesh explants from a single patient. Surg Innov 14(3):168–176PubMedCrossRef Costello CR, Bachman SL, Grant SA, Cleveland DS, Loy TS, Ramshaw BJ (2007) Characterization of heavyweight and lightweight polypropylene prosthetic mesh explants from a single patient. Surg Innov 14(3):168–176PubMedCrossRef
23.
go back to reference O’Dowd A (2012) UK launches inquiry into safety of PIP breast implants. BMJ 3(344):e11CrossRef O’Dowd A (2012) UK launches inquiry into safety of PIP breast implants. BMJ 3(344):e11CrossRef
24.
go back to reference Muysoms F, Campanelli G, Champault GG, DeBeaux AC, Dietz UA, Jeekel J, Klinge U, Köckerling F, Mandala V, Montgomery A, Morales Conde S, Puppe F, Simmermacher RK, Śmietański M, Miserez M (2012) EuraHS: the development of an international online platform for registration and outcome measurement of ventral abdominal wall hernia repair. Hernia 16(3):239–250PubMedCrossRef Muysoms F, Campanelli G, Champault GG, DeBeaux AC, Dietz UA, Jeekel J, Klinge U, Köckerling F, Mandala V, Montgomery A, Morales Conde S, Puppe F, Simmermacher RK, Śmietański M, Miserez M (2012) EuraHS: the development of an international online platform for registration and outcome measurement of ventral abdominal wall hernia repair. Hernia 16(3):239–250PubMedCrossRef
Metadata
Title
Lessons and challenges during a 5-year follow-up of 21 Composix Kugel implantations
Authors
A. Wiegering
N. Schlegel
C. Isbert
C. Jurowich
S. Doht
C. T. Germer
U. A. Dietz
Publication date
01-08-2013
Publisher
Springer Paris
Published in
Hernia / Issue 4/2013
Print ISSN: 1265-4906
Electronic ISSN: 1248-9204
DOI
https://doi.org/10.1007/s10029-013-1096-5

Other articles of this Issue 4/2013

Hernia 4/2013 Go to the issue