Development of a quantitative preclinical screening model for implant osseointegration in rat tail vertebra

Authors: Sándor Farkasdi, Dávid Pammer, Róbert Rácz, Gergely Hriczó-Koperdák, Bence Tamás Szabó, Csaba Dobó-Nagy, Beáta Kerémi, József Blazsek, Frederic Cuisinier, Gang Wu, Gábor Varga

Published in: Clinical Oral Investigations | Issue 7/2019

Login to get access

Abstract

Objectives

Functional tooth replacement and bone regeneration are parts of the daily practice in modern dentistry, but well-reproducible and relatively inexpensive experimental models are still missing. We aimed to develop a new small animal model to monitor osseointegration utilizing the combination of multiple evaluation protocols.

Material and methods

After cutting the tail between the C4 and C5 vertebrae in Wistar rats, costume made, parallel walled, non-threaded implants were placed into the center of the tail parallel with its longitudinal axis using a surgical guide. Osseointegration of the titanium implants was followed between 4 and 16 weeks after surgery applying axial extraction force, and resonance frequency analysis as functional tests, and histomorphometry and micro-CT as structural evaluations.

Results

In functional tests, we observed that both methods are suitable for the detection of the time-dependent increase in osseointegration, but the sensitivity of the pull-out technique (an approximately five times increase with rather low standard error) was much higher than that of the resonance frequency analysis. In structural evaluations, changes in the detected bone implant contact values measured by histomorphometry (yielding 1.5 times increase, with low variations of data) were more reliable than micro-CT based evaluations to screen the developments of contact between bone and implant.

Conclusion

Our results provide evidence that the caudal vertebrae osseointegration model is useful for the preclinical evaluation of implant integration into the bone.

Clinical relevance

The combination of the biomechanical and structural tests offers a well-reproducible small animal system that can be suitable for studying the integration of various implant materials and surface treatments.
Literature
1.
go back to reference Branemark PI, Adell R, Breine U, Hansson BO, Lindstrom J, Ohlsson A (1969) Intra-osseous anchorage of dental prostheses. I. Experimental studies. Scand J Plast Reconstr Surg 3(2):81–100CrossRefPubMed Branemark PI, Adell R, Breine U, Hansson BO, Lindstrom J, Ohlsson A (1969) Intra-osseous anchorage of dental prostheses. I. Experimental studies. Scand J Plast Reconstr Surg 3(2):81–100CrossRefPubMed
2.
go back to reference Branemark PI (1983) Osseointegration and its experimental background. J Prosthet Dent 50(3):399–410CrossRefPubMed Branemark PI (1983) Osseointegration and its experimental background. J Prosthet Dent 50(3):399–410CrossRefPubMed
4.
go back to reference Berglundh T, Abrahamsson I, Lang NP, Lindhe J (2003) De novo alveolar bone formation adjacent to endosseous implants. Clin Oral Implants Res 14(3):251–262CrossRefPubMed Berglundh T, Abrahamsson I, Lang NP, Lindhe J (2003) De novo alveolar bone formation adjacent to endosseous implants. Clin Oral Implants Res 14(3):251–262CrossRefPubMed
6.
go back to reference Pearce AI, Richards RG, Milz S, Schneider E, Pearce SG (2007) Animal models for implant biomaterial research in bone: a review. Eur Cell Mater 13:1–10CrossRefPubMed Pearce AI, Richards RG, Milz S, Schneider E, Pearce SG (2007) Animal models for implant biomaterial research in bone: a review. Eur Cell Mater 13:1–10CrossRefPubMed
8.
go back to reference Atsumi M, Park SH, Wang HL (2007) Methods used to assess implant stability: current status. Int J Oral Maxillofac Implants 22(5):743–754PubMed Atsumi M, Park SH, Wang HL (2007) Methods used to assess implant stability: current status. Int J Oral Maxillofac Implants 22(5):743–754PubMed
13.
go back to reference Brunski JB, Puleo DA, Nanci A (2000) Biomaterials and biomechanics of oral and maxillofacial implants: current status and future developments. Int J Oral Maxillofac Implants 15(1):15–46PubMed Brunski JB, Puleo DA, Nanci A (2000) Biomaterials and biomechanics of oral and maxillofacial implants: current status and future developments. Int J Oral Maxillofac Implants 15(1):15–46PubMed
15.
go back to reference Friberg B, Sennerby L, Meredith N, Lekholm U (1999) A comparison between cutting torque and resonance frequency measurements of maxillary implants - a 20-month clinical study. Int J Oral Maxillofac Surg 28(4):297–303CrossRefPubMed Friberg B, Sennerby L, Meredith N, Lekholm U (1999) A comparison between cutting torque and resonance frequency measurements of maxillary implants - a 20-month clinical study. Int J Oral Maxillofac Surg 28(4):297–303CrossRefPubMed
16.
go back to reference O'Sullivan D, Sennerby L, Jagger D, Meredith N (2004) A comparison of two methods of enhancing implant primary stability. Clin Implant Dent Relat Res 6(1):48–57CrossRefPubMed O'Sullivan D, Sennerby L, Jagger D, Meredith N (2004) A comparison of two methods of enhancing implant primary stability. Clin Implant Dent Relat Res 6(1):48–57CrossRefPubMed
19.
go back to reference Bernhardt R, Kuhlisch E, Schulz MC, Eckelt U, Stadlinger B (2012) Comparison of bone-implant contact and bone-implant volume between 2D-histological sections and 3D-SRmicroCT slices. Eur Cell Mater 23:237–247 discussion 247-238CrossRefPubMed Bernhardt R, Kuhlisch E, Schulz MC, Eckelt U, Stadlinger B (2012) Comparison of bone-implant contact and bone-implant volume between 2D-histological sections and 3D-SRmicroCT slices. Eur Cell Mater 23:237–247 discussion 247-238CrossRefPubMed
26.
go back to reference Hartung T (2010) Comparative analysis of the revised directive 2010/63/EU for the protection of laboratory animals with its predecessor 86/609/EEC - a t4 report. Altex 27(4):285–303CrossRefPubMed Hartung T (2010) Comparative analysis of the revised directive 2010/63/EU for the protection of laboratory animals with its predecessor 86/609/EEC - a t4 report. Altex 27(4):285–303CrossRefPubMed
28.
go back to reference Schmitz JP, Hollinger JO (1986) The critical size defect as an experimental model for craniomandibulofacial nonunions. Clin Orthop Relat Res (205):299–308 Schmitz JP, Hollinger JO (1986) The critical size defect as an experimental model for craniomandibulofacial nonunions. Clin Orthop Relat Res (205):299–308
31.
go back to reference Kuchler U, Chappuis V, Bornstein MM, Siewczyk M, Gruber R, Maestre L, Buser D (2017) Development of implant stability quotient values of implants placed with simultaneous sinus floor elevation - results of a prospective study with 109 implants. Clin Oral Implants Res 28(1):109–115. https://doi.org/10.1111/clr.12768 CrossRefPubMed Kuchler U, Chappuis V, Bornstein MM, Siewczyk M, Gruber R, Maestre L, Buser D (2017) Development of implant stability quotient values of implants placed with simultaneous sinus floor elevation - results of a prospective study with 109 implants. Clin Oral Implants Res 28(1):109–115. https://​doi.​org/​10.​1111/​clr.​12768 CrossRefPubMed
32.
go back to reference Sadeghi R, Rokn AR, Miremadi A (2015) Comparison of implant stability using resonance frequency analysis: osteotome versus conventional drilling. J Dent 12(9):647–654 Sadeghi R, Rokn AR, Miremadi A (2015) Comparison of implant stability using resonance frequency analysis: osteotome versus conventional drilling. J Dent 12(9):647–654
33.
go back to reference Cha JY, Lim JK, Song JW, Sato D, Kenmotsu M, Inoue T, Park YC (2009) Influence of the length of the loading period after placement of orthodontic mini-implants on changes in bone histomorphology: microcomputed tomographic and histologic analysis. Int J Oral Maxillofac Implants 24(5):842–849PubMed Cha JY, Lim JK, Song JW, Sato D, Kenmotsu M, Inoue T, Park YC (2009) Influence of the length of the loading period after placement of orthodontic mini-implants on changes in bone histomorphology: microcomputed tomographic and histologic analysis. Int J Oral Maxillofac Implants 24(5):842–849PubMed
36.
go back to reference Liu Y, Huse RO, de Groot K, Buser D, Hunziker EB (2007) Delivery mode and efficacy of BMP-2 in association with implants. J Dent Res 86:84–89CrossRefPubMed Liu Y, Huse RO, de Groot K, Buser D, Hunziker EB (2007) Delivery mode and efficacy of BMP-2 in association with implants. J Dent Res 86:84–89CrossRefPubMed
37.
go back to reference Schenk RKOA, Herrmann W (1984) Preparation of calcified tissues for light microscopy. In: GR D, editor. Methods of calcified tissue preparation. Elsevier Science Publishers BV, Amsterdam, pp 1–56 Schenk RKOA, Herrmann W (1984) Preparation of calcified tissues for light microscopy. In: GR D, editor. Methods of calcified tissue preparation. Elsevier Science Publishers BV, Amsterdam, pp 1–56
48.
go back to reference Ronold HJ, Ellingsen JE, Lyngstadaas SP (2003) Tensile force testing of optimized coin-shaped titanium implant attachment kinetics in the rabbit tibiae. J Mater Sci Mater Med 14(10):843–849CrossRefPubMed Ronold HJ, Ellingsen JE, Lyngstadaas SP (2003) Tensile force testing of optimized coin-shaped titanium implant attachment kinetics in the rabbit tibiae. J Mater Sci Mater Med 14(10):843–849CrossRefPubMed
50.
go back to reference Soncini M, Rodriguez y Baena R, Pietrabissa R, Quaglini V, Rizzo S, Zaffe D (2002) Experimental procedure for the evaluation of the mechanical properties of the bone surrounding dental implants. Biomaterials 23(1):9–17CrossRefPubMed Soncini M, Rodriguez y Baena R, Pietrabissa R, Quaglini V, Rizzo S, Zaffe D (2002) Experimental procedure for the evaluation of the mechanical properties of the bone surrounding dental implants. Biomaterials 23(1):9–17CrossRefPubMed
53.
59.
go back to reference Abrahamsson I, Linder E, Lang NP (2009) Implant stability in relation to osseointegration: an experimental study in the Labrador dog. Clin Oral Implants Res 20(3):313–318CrossRefPubMed Abrahamsson I, Linder E, Lang NP (2009) Implant stability in relation to osseointegration: an experimental study in the Labrador dog. Clin Oral Implants Res 20(3):313–318CrossRefPubMed
Metadata
Title
Development of a quantitative preclinical screening model for implant osseointegration in rat tail vertebra
Authors
Sándor Farkasdi
Dávid Pammer
Róbert Rácz
Gergely Hriczó-Koperdák
Bence Tamás Szabó
Csaba Dobó-Nagy
Beáta Kerémi
József Blazsek
Frederic Cuisinier
Gang Wu
Gábor Varga
Publication date
01-07-2019
Publisher
Springer Berlin Heidelberg
Published in
Clinical Oral Investigations / Issue 7/2019
Print ISSN: 1432-6981
Electronic ISSN: 1436-3771
DOI
https://doi.org/10.1007/s00784-018-2661-1

Other articles of this Issue 7/2019

Clinical Oral Investigations 7/2019 Go to the issue