Skip to main content
Top
Published in: Clinical Oral Investigations 3/2008

01-09-2008 | Original Article

Cone-beam computed tomography in assessment of periodontal ligament space: in vitro study on artificial tooth model

Authors: Nurdan Özmeric, Irina Kostioutchenko, Georg Hägler, Matthias Frentzen, Pia-Merete Jervøe-Storm

Published in: Clinical Oral Investigations | Issue 3/2008

Login to get access

Abstract

The aim of this in vitro study was to compare cone-beam computed tomography (CBCT) to conventional radiography (RG) in the assessment of the periodontal ligament space. A phantom with a variable “artificial” periodontal ligament space (0, 100, 200, 300, and 400 μm) was used as a model. The examinations were performed simultaneously with RG and NewTom® 9000 digital volume tomograph. Assorted after increasing widths, 15 RGs and 15 CBCT images were presented for judgment to 20 dentists (DD), 20 dental assistants, and 20 dental students. Several weeks later, the same images were randomly mixed and presented to the same 20 DD again. The trial shows that RG gaps wider than 200 μm could be correctly identified by all participants with an accuracy of nearly 100%. A significant difference was observed between the modalities (p < 0.05 and p < 0.001) where conventional RGs performed better than CBCT for assessment of periodontal ligament space. Interobserver variation in relation to each technique was evaluated and no significant difference was found (p > 0.05). In subjective evaluations of image quality with CBCT, the results were basically inferior for images of artificial periodontal ligament space, regardless of the experience of the observers.
Literature
1.
go back to reference Akesson L, Hakansson J, Rohlin M, Zoger B (1993) An evaluation of image quality for the assessment of the marginal bone level in panoramic radiography. A comparison of radiographs from different dental clinics. Swed Dent J 17:9–21PubMed Akesson L, Hakansson J, Rohlin M, Zoger B (1993) An evaluation of image quality for the assessment of the marginal bone level in panoramic radiography. A comparison of radiographs from different dental clinics. Swed Dent J 17:9–21PubMed
2.
go back to reference Carranza FA (1996) Radiographic and other aids in the diagnosis of periodontal disease. In: Carranza FA, Newman MG (eds) Clinical periodontology. 8th edn. Saunders, Philadelphia, pp 364–365 Carranza FA (1996) Radiographic and other aids in the diagnosis of periodontal disease. In: Carranza FA, Newman MG (eds) Clinical periodontology. 8th edn. Saunders, Philadelphia, pp 364–365
3.
go back to reference Gonzales TS, Coleman GC (1999) Periodontal manifestations of collagen vascular disorders. Periodontol 2000 21:94–105PubMedCrossRef Gonzales TS, Coleman GC (1999) Periodontal manifestations of collagen vascular disorders. Periodontol 2000 21:94–105PubMedCrossRef
4.
go back to reference Guerrero ME, Jacobs R, Loubele M, Schutyser F, Suetens P, van Steenberghe D (2006) State-of-the-art on cone beam CT imaging for preoperative planning of implant placement. Clin Oral Invest 10:1–7CrossRef Guerrero ME, Jacobs R, Loubele M, Schutyser F, Suetens P, van Steenberghe D (2006) State-of-the-art on cone beam CT imaging for preoperative planning of implant placement. Clin Oral Invest 10:1–7CrossRef
5.
go back to reference Hashimoto K, Arai Y, Iwai K, Araki M, Kawashima S, Terakado M (2003) A comparison of a new limited cone beam computed tomography machine for dental use with a multidetector row helical CT machine. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 95:371–377PubMedCrossRef Hashimoto K, Arai Y, Iwai K, Araki M, Kawashima S, Terakado M (2003) A comparison of a new limited cone beam computed tomography machine for dental use with a multidetector row helical CT machine. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 95:371–377PubMedCrossRef
6.
go back to reference Hashimoto K, Kawashima S, Araki M, Iwai K, Sawada K, Akiyama Y (2006) Comparison of image performance between cone-beam computed tomography for dental use and four-row multidetector helical CT. J Oral Sci 48:27–34PubMedCrossRef Hashimoto K, Kawashima S, Araki M, Iwai K, Sawada K, Akiyama Y (2006) Comparison of image performance between cone-beam computed tomography for dental use and four-row multidetector helical CT. J Oral Sci 48:27–34PubMedCrossRef
7.
go back to reference Hirschmann PN (1987) Radiographic interpretation of chronic periodontitis. Int Dent J 37:3–9PubMed Hirschmann PN (1987) Radiographic interpretation of chronic periodontitis. Int Dent J 37:3–9PubMed
8.
go back to reference Ito K, Yoshinuma N, Goke E, Arai Y, Shinoda K (2001) Clinical application of a new compact computed tomography system for evaluating the outcome of regenerative therapy: a case report. J Periodontol 72:696–702PubMedCrossRef Ito K, Yoshinuma N, Goke E, Arai Y, Shinoda K (2001) Clinical application of a new compact computed tomography system for evaluating the outcome of regenerative therapy: a case report. J Periodontol 72:696–702PubMedCrossRef
9.
go back to reference Lofthag-Hansen S, Huumonen S, Grondahl K, Grondahl HG (2007) Limited cone-beam CT and intraoral radiography for the diagnosis of periapical pathology. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 103:114–119PubMedCrossRef Lofthag-Hansen S, Huumonen S, Grondahl K, Grondahl HG (2007) Limited cone-beam CT and intraoral radiography for the diagnosis of periapical pathology. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 103:114–119PubMedCrossRef
10.
go back to reference Loubele M, Maes F, Schutyser F, Marchal G, Jacobs R, Suetens P (2006) Assessment of bone segmentation quality of cone-beam CT versus multislice spiral CT: a pilot study. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 102:225–234PubMedCrossRef Loubele M, Maes F, Schutyser F, Marchal G, Jacobs R, Suetens P (2006) Assessment of bone segmentation quality of cone-beam CT versus multislice spiral CT: a pilot study. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 102:225–234PubMedCrossRef
11.
go back to reference Ludlow JB, Davies-Ludlow LE, Brooks SL (2003) Dosimetry of two extraoral direct digital imaging devices: NewTom cone beam CT and Orthophos Plus DS panoramic unit. Dentomaxillofac Radiol 32:229–234PubMedCrossRef Ludlow JB, Davies-Ludlow LE, Brooks SL (2003) Dosimetry of two extraoral direct digital imaging devices: NewTom cone beam CT and Orthophos Plus DS panoramic unit. Dentomaxillofac Radiol 32:229–234PubMedCrossRef
12.
go back to reference Ludlow JB, Davies-Ludlow LE, Brooks SL, Howerton WB (2006) Dosimetry of 3 CBCT devices for oral and maxillofacial radiology: CB Mercuray, NewTom 3G and i-CAT. Dentomaxillofac Radiol 35:219–226PubMedCrossRef Ludlow JB, Davies-Ludlow LE, Brooks SL, Howerton WB (2006) Dosimetry of 3 CBCT devices for oral and maxillofacial radiology: CB Mercuray, NewTom 3G and i-CAT. Dentomaxillofac Radiol 35:219–226PubMedCrossRef
13.
go back to reference Mah JK, Danforth RA, Bumann A, Hatcher D (2003) Radiation absorbed in maxillofacial imaging with a new dental computed tomography device. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 96:508–513PubMedCrossRef Mah JK, Danforth RA, Bumann A, Hatcher D (2003) Radiation absorbed in maxillofacial imaging with a new dental computed tomography device. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 96:508–513PubMedCrossRef
14.
go back to reference Marmulla R, Wörtche R, Mühling J, Hassfeld S (2005) Geometric accuracy of the NewTom 9000 Cone Beam CT. Dentomaxillofac Radiol 34:28–31PubMedCrossRef Marmulla R, Wörtche R, Mühling J, Hassfeld S (2005) Geometric accuracy of the NewTom 9000 Cone Beam CT. Dentomaxillofac Radiol 34:28–31PubMedCrossRef
15.
go back to reference Mengel R, Candir M, Shiratori K, Flores-de-Jacoby L (2005) Digital volume tomography in the diagnosis of periodontal defects: an in vitro study on native pig and human mandibles. J Periodontol 76:665–673PubMedCrossRef Mengel R, Candir M, Shiratori K, Flores-de-Jacoby L (2005) Digital volume tomography in the diagnosis of periodontal defects: an in vitro study on native pig and human mandibles. J Periodontol 76:665–673PubMedCrossRef
16.
go back to reference Misch KA, Yi ES, Sarment DP (2006) Accuracy of cone beam computed tomography for periodontal defect measurements. J Periodontol 77:1261–1266PubMedCrossRef Misch KA, Yi ES, Sarment DP (2006) Accuracy of cone beam computed tomography for periodontal defect measurements. J Periodontol 77:1261–1266PubMedCrossRef
18.
go back to reference Mozzo P, Procacci C, Tacconi A, Tinazzi Martini P, Bergamo Andreis IA (1998) A new volumetric CT machine for dental imaging based on the cone-beam technique: preliminary results. Eur Radiol 8:1558–1564PubMedCrossRef Mozzo P, Procacci C, Tacconi A, Tinazzi Martini P, Bergamo Andreis IA (1998) A new volumetric CT machine for dental imaging based on the cone-beam technique: preliminary results. Eur Radiol 8:1558–1564PubMedCrossRef
19.
go back to reference Naito T, Hosokawa R, Yokota M (1998) Three-dimensional alveolar bone morphology analysis using computed tomography. J Periodontol 69:584–589PubMed Naito T, Hosokawa R, Yokota M (1998) Three-dimensional alveolar bone morphology analysis using computed tomography. J Periodontol 69:584–589PubMed
20.
go back to reference Nauert K, Berg R (1999) Evaluation of labio-lingual bony support of lower incisors in orthodontically untreated adults with the help of computed tomography. J Orofac Orthop 60:321–334PubMedCrossRef Nauert K, Berg R (1999) Evaluation of labio-lingual bony support of lower incisors in orthodontically untreated adults with the help of computed tomography. J Orofac Orthop 60:321–334PubMedCrossRef
21.
go back to reference Oliveira Costa F, Cota LO, Costa JE, Pordeus IA (2007) Periodontal disease progression among young subjects with no preventive dental care: a 52-month follow-up study. J Periodontol 78:198–203PubMedCrossRef Oliveira Costa F, Cota LO, Costa JE, Pordeus IA (2007) Periodontal disease progression among young subjects with no preventive dental care: a 52-month follow-up study. J Periodontol 78:198–203PubMedCrossRef
22.
go back to reference Pawelzik J, Cohnen M, Willers R, Becker J (2002) A comparison of conventional panoramic radiographs with volumetric computed tomography images in the preoperative assessment of impacted mandibular third molars. J Oral Maxillofac Surg 60:979–984PubMedCrossRef Pawelzik J, Cohnen M, Willers R, Becker J (2002) A comparison of conventional panoramic radiographs with volumetric computed tomography images in the preoperative assessment of impacted mandibular third molars. J Oral Maxillofac Surg 60:979–984PubMedCrossRef
23.
go back to reference Rushton VE, Horner K, Worthington HV (1999) Factors influencing the selection of panoramic radiography in general dental practice. J Dent 27:565–571PubMedCrossRef Rushton VE, Horner K, Worthington HV (1999) Factors influencing the selection of panoramic radiography in general dental practice. J Dent 27:565–571PubMedCrossRef
24.
go back to reference Slots J (2003) Update on general health risk of periodontal disease. Int Dent J 53:200–207PubMed Slots J (2003) Update on general health risk of periodontal disease. Int Dent J 53:200–207PubMed
25.
go back to reference Stavropoulos A, Wenzel A (2007) Accuracy of cone beam dental CT, intraoral digital and conventional film radiography for the detection of periapical lesions. An ex vivo study in pig jaws. Clin Oral Investig 11:101–106PubMedCrossRef Stavropoulos A, Wenzel A (2007) Accuracy of cone beam dental CT, intraoral digital and conventional film radiography for the detection of periapical lesions. An ex vivo study in pig jaws. Clin Oral Investig 11:101–106PubMedCrossRef
26.
go back to reference Tammisalo T, Luostarinen T, Vähätalo K, Neva M (1996) Detailed tomography of periapical and peridontal lesions. Diagnostic accuracy compared with periapical radiography. Dentomaxillofac Radiol 25:89–96PubMed Tammisalo T, Luostarinen T, Vähätalo K, Neva M (1996) Detailed tomography of periapical and peridontal lesions. Diagnostic accuracy compared with periapical radiography. Dentomaxillofac Radiol 25:89–96PubMed
27.
go back to reference Van Assche N, van Steenberghe D, Guerrero ME, Hirsch E, Schutyser F, Quirynen M, Jacobs R (2007) Accuracy of implant placement based on pre-surgical planning of three-dimensional cone-beam images: a pilot study. J Clin Periodontol 34:816–821PubMedCrossRef Van Assche N, van Steenberghe D, Guerrero ME, Hirsch E, Schutyser F, Quirynen M, Jacobs R (2007) Accuracy of implant placement based on pre-surgical planning of three-dimensional cone-beam images: a pilot study. J Clin Periodontol 34:816–821PubMedCrossRef
28.
go back to reference Vandenberghe B, Jacobs R, Yang J (2007) Diagnostic validity (or acuity) of 2D CCD versus 3D CBCT-images for assessing periodontal breakdown. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 104:395–401PubMedCrossRef Vandenberghe B, Jacobs R, Yang J (2007) Diagnostic validity (or acuity) of 2D CCD versus 3D CBCT-images for assessing periodontal breakdown. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 104:395–401PubMedCrossRef
29.
go back to reference Ziegler CM, Woertche R, Brief J, Hassfeld S (2002) Clinical indications for digital volume tomography in oral and maxillofacial surgery. Dentomaxillofac Radiol 31:126–130PubMedCrossRef Ziegler CM, Woertche R, Brief J, Hassfeld S (2002) Clinical indications for digital volume tomography in oral and maxillofacial surgery. Dentomaxillofac Radiol 31:126–130PubMedCrossRef
Metadata
Title
Cone-beam computed tomography in assessment of periodontal ligament space: in vitro study on artificial tooth model
Authors
Nurdan Özmeric
Irina Kostioutchenko
Georg Hägler
Matthias Frentzen
Pia-Merete Jervøe-Storm
Publication date
01-09-2008
Publisher
Springer-Verlag
Published in
Clinical Oral Investigations / Issue 3/2008
Print ISSN: 1432-6981
Electronic ISSN: 1436-3771
DOI
https://doi.org/10.1007/s00784-008-0186-8

Other articles of this Issue 3/2008

Clinical Oral Investigations 3/2008 Go to the issue