Skip to main content
Top
Published in: Acta Neurochirurgica 3/2019

01-03-2019 | Computed Tomography | Original Article - Brain Tumors

Stereotactic brain biopsy: evaluation of robot-assisted procedure in 60 patients

Authors: Laura Terrier, Vianney Gilard, Florent Marguet, Maxime Fontanilles, Stéphane Derrey

Published in: Acta Neurochirurgica | Issue 3/2019

Login to get access

Abstract

Background

Frameless stereotactic biopsies, particularly robot-assisted procedures are increasing in neurosurgery centers. Results of these procedures should be at least equal to or greater than frame-based reference procedure. Evaluate robot-assisted technology is necessary in particular, when a team has chosen to switch from one to another method.

Objective

The objective of our prospective work was (i) to evaluate the success rate of contributive robotic-assisted biopsy in 60 patients, to report the morbidity and mortality associated with the procedure and (ii) to compare it with literature data.

Methods

We performed a prospective and descriptive study including 60 consecutive patients having had robotic-assisted stereotactic biopsy at the Rouen University Hospital, France. All patients had presurgical imaging before the procedure included Magnetic Resonance Imaging merged with Computed Tomography scan acquisition. Registration was mostly performed with a touch-free laser (57/60). A control Computed Tomography scan was always realized at day 0 or day 1 after surgery. Data collected were success rate, bleeding, clinical worsening, infection, and mortality.

Results

All the biopsies were considered as contributive and lead to the final diagnosis. In 41/60 patients (68%), the lesion was glial. Six in 60 patients (10%) had visible bleeding without clinical worsening related, 5/60 patients (8.5%) showed clinical impairment following surgery, which was permanent in 2 patients, and 1/60 patient presented generalized seizures. We did not report any infection and mortality.

Conclusion

Robot-assisted frameless surgery is efficient and provides a reasonable alternative to frame-based procedure. The operating time can be reduced, without increasing morbidity and mortality rates.
Literature
1.
go back to reference Abernathey CD, Camacho A, Kelly PJ (1989) Stereotaxic suboccipital transcerebellar biopsy of pontine mass lesions. J Neurosurg 70(2):195–200CrossRefPubMed Abernathey CD, Camacho A, Kelly PJ (1989) Stereotaxic suboccipital transcerebellar biopsy of pontine mass lesions. J Neurosurg 70(2):195–200CrossRefPubMed
2.
go back to reference Air EL, Leach JL, Warnick RE, McPherson CM (2009) Comparing the risks of frameless stereotactic biopsy in eloquent and noneloquent regions of the brain: a retrospective review of 284 cases. J Neurosurg 111:820–824CrossRefPubMed Air EL, Leach JL, Warnick RE, McPherson CM (2009) Comparing the risks of frameless stereotactic biopsy in eloquent and noneloquent regions of the brain: a retrospective review of 284 cases. J Neurosurg 111:820–824CrossRefPubMed
3.
go back to reference Balossier A, Blond S, Reyns N (2016) Endoscopic versus stereotactic procedure for pineal tumor biopsies: focus on overall efficacy rate. World Neurosurg 92:223–228CrossRefPubMed Balossier A, Blond S, Reyns N (2016) Endoscopic versus stereotactic procedure for pineal tumor biopsies: focus on overall efficacy rate. World Neurosurg 92:223–228CrossRefPubMed
4.
go back to reference Barnett GH, Miller DW, Weisenberger J (1999) Frameless stereotaxy with scalp-applied fiducial markers for brain biopsy procedures: experience in 218 cases. J Neurosurg 91:569–576CrossRefPubMed Barnett GH, Miller DW, Weisenberger J (1999) Frameless stereotaxy with scalp-applied fiducial markers for brain biopsy procedures: experience in 218 cases. J Neurosurg 91:569–576CrossRefPubMed
5.
go back to reference Bekelis K, Radwan TA, Desai A, Roberts DW (2012) Frameless robotically targeted stereotactic brain biopsy: feasibility, diagnostic yield, and safety. J Neurosurg 116:1002–1006CrossRefPubMed Bekelis K, Radwan TA, Desai A, Roberts DW (2012) Frameless robotically targeted stereotactic brain biopsy: feasibility, diagnostic yield, and safety. J Neurosurg 116:1002–1006CrossRefPubMed
6.
go back to reference Benabid AL, Cinquin P, Lavalle S, Le Bas JF, Demongeot J, De Rougemont J (1987) Computer-driven robot for stereotactic surgery connected to CT scan and magnetic resonance imaging: technological design and preliminary results. Appl Neurophysiol 50:153–154PubMed Benabid AL, Cinquin P, Lavalle S, Le Bas JF, Demongeot J, De Rougemont J (1987) Computer-driven robot for stereotactic surgery connected to CT scan and magnetic resonance imaging: technological design and preliminary results. Appl Neurophysiol 50:153–154PubMed
7.
go back to reference Benabid AL, Hoffmann D, Lavallee S, Cinquin P, Demongeot J, Le Bas JF (1991) Is there any future for robots in neurosurgery? Adv Tech Stand Neurosurg 18:3–45CrossRefPubMed Benabid AL, Hoffmann D, Lavallee S, Cinquin P, Demongeot J, Le Bas JF (1991) Is there any future for robots in neurosurgery? Adv Tech Stand Neurosurg 18:3–45CrossRefPubMed
8.
go back to reference Benabid AL, Lavallee S, Hoffmann D, Cinquin P, Demongeot J, Danel F (1992) Potential use of robots in endoscopic neurosurgery. Acta Neurochir Suppl (Wien) 54:93–97CrossRef Benabid AL, Lavallee S, Hoffmann D, Cinquin P, Demongeot J, Danel F (1992) Potential use of robots in endoscopic neurosurgery. Acta Neurochir Suppl (Wien) 54:93–97CrossRef
9.
go back to reference Bernays RL, Kollias SS, Khan N, Brandner S, Meier S, Yo-nekawa Y (2002) Histological yield, complications, and technological considerations in 114 consecutive frameless stereotactic biopsy procedures aided by open intraoperative magnetic resonance imaging. J Neurosurg 97:354–362CrossRefPubMed Bernays RL, Kollias SS, Khan N, Brandner S, Meier S, Yo-nekawa Y (2002) Histological yield, complications, and technological considerations in 114 consecutive frameless stereotactic biopsy procedures aided by open intraoperative magnetic resonance imaging. J Neurosurg 97:354–362CrossRefPubMed
10.
go back to reference Bernstein M, Parrent AG (1994) Complications of CT-guided stereotactic biopsy of intra-axial brain lesions. J Neurosurg 81:165–168CrossRefPubMed Bernstein M, Parrent AG (1994) Complications of CT-guided stereotactic biopsy of intra-axial brain lesions. J Neurosurg 81:165–168CrossRefPubMed
11.
go back to reference Boviatsis EL, Kouyialis AT, Stranjalis G, Korfias S, Sakas DE (2003) CT-guided stereotactic biopsies of brain stem lesions: personal experience and literature review. Neurol Sci 24:97–107CrossRefPubMed Boviatsis EL, Kouyialis AT, Stranjalis G, Korfias S, Sakas DE (2003) CT-guided stereotactic biopsies of brain stem lesions: personal experience and literature review. Neurol Sci 24:97–107CrossRefPubMed
12.
go back to reference Coca HA, Cebula H, Benmekhbi M, Chenard MP, Entz-Werle N, Proust F (2016) Diffuse intrinsic pontine gliomas in children: interest of robotic frameless assisted biopsy. A technical note. Neurochirurgie 62(6):327–331CrossRefPubMed Coca HA, Cebula H, Benmekhbi M, Chenard MP, Entz-Werle N, Proust F (2016) Diffuse intrinsic pontine gliomas in children: interest of robotic frameless assisted biopsy. A technical note. Neurochirurgie 62(6):327–331CrossRefPubMed
13.
go back to reference Dammers R, Haitsma IK, Schouten JW, Kros JM, Avezaat CJJ, Vincent AJP (2008) Safety and efficacy of frameless and frame-based intracranial biopsy techniques. Acta Neurochir 150:23–29CrossRefPubMed Dammers R, Haitsma IK, Schouten JW, Kros JM, Avezaat CJJ, Vincent AJP (2008) Safety and efficacy of frameless and frame-based intracranial biopsy techniques. Acta Neurochir 150:23–29CrossRefPubMed
14.
go back to reference De Benedictis A, Trezza A, Carai A, Genovese E, Procaccini E, Messina R (2017) Robot-assisted procedures in pediatric neurosurgery. Neurosurg Focus E7:10.3171 De Benedictis A, Trezza A, Carai A, Genovese E, Procaccini E, Messina R (2017) Robot-assisted procedures in pediatric neurosurgery. Neurosurg Focus E7:10.3171
15.
go back to reference Dellaretti M, Reyns N, Touzet G, Dubois F, Gusmão S, Pereira JLB (2012) Stereotactic biopsy for brainstem tumors: comparison of transcerebellar with transfrontal approach. Stereotact Funct Neurosurg 90:79–83CrossRefPubMed Dellaretti M, Reyns N, Touzet G, Dubois F, Gusmão S, Pereira JLB (2012) Stereotactic biopsy for brainstem tumors: comparison of transcerebellar with transfrontal approach. Stereotact Funct Neurosurg 90:79–83CrossRefPubMed
16.
go back to reference Dorward NL, Alberti O, Palmer JD, Kitchen ND, Thomas DG (1999) Accuracy of true frameless stereotaxy: in vivo measurement and laboratory phantom studies. Technical note. J Neurosurg 90:160–168CrossRefPubMed Dorward NL, Alberti O, Palmer JD, Kitchen ND, Thomas DG (1999) Accuracy of true frameless stereotaxy: in vivo measurement and laboratory phantom studies. Technical note. J Neurosurg 90:160–168CrossRefPubMed
17.
go back to reference Dorward NL, Paleologos TS, Alberti O, Thomas DG (2002) The advantages of frameless stereotactic biopsy over frame-based biopsy. Br J Neurosurg 16:110–118CrossRefPubMed Dorward NL, Paleologos TS, Alberti O, Thomas DG (2002) The advantages of frameless stereotactic biopsy over frame-based biopsy. Br J Neurosurg 16:110–118CrossRefPubMed
18.
go back to reference Drake JM, Joy M, Goldenberg A, Kreindler D (1991) Computer and robot-assisted resection of thalamic astrocytomas in children. Neurosurgery 29:27–33CrossRefPubMed Drake JM, Joy M, Goldenberg A, Kreindler D (1991) Computer and robot-assisted resection of thalamic astrocytomas in children. Neurosurgery 29:27–33CrossRefPubMed
19.
go back to reference Eljamel M (2008) Robotic applications in neurosurgery. Med Robots 1:1–24 Eljamel M (2008) Robotic applications in neurosurgery. Med Robots 1:1–24
20.
go back to reference Faria C, Erlhagen W, Rito M, De Momi E, Ferrigno G, Bicho E (2015) Review of robotic technology for stereotactic neurosurgery. IEEE Rev Biomed Eng 8:125–137CrossRefPubMed Faria C, Erlhagen W, Rito M, De Momi E, Ferrigno G, Bicho E (2015) Review of robotic technology for stereotactic neurosurgery. IEEE Rev Biomed Eng 8:125–137CrossRefPubMed
21.
go back to reference Field M, Witham TF, Flickinger JC, Kondziolka D, Lunsford LD (2004) Comprehensive assessment of haemorrhage risks and outcomes after stereotactic brain biopsy. J Neurosurg 94:545–551CrossRef Field M, Witham TF, Flickinger JC, Kondziolka D, Lunsford LD (2004) Comprehensive assessment of haemorrhage risks and outcomes after stereotactic brain biopsy. J Neurosurg 94:545–551CrossRef
22.
go back to reference Frank F, Fabrizi AP, Frank-Ricci R, Gaist G, Sedan R, Peragut GC (1988) Stereotactic biopsy and treatment of brain stem lesions: combined study of 33 cases (Bologna-Marseille). Acta Neurochir 42:177–181 Frank F, Fabrizi AP, Frank-Ricci R, Gaist G, Sedan R, Peragut GC (1988) Stereotactic biopsy and treatment of brain stem lesions: combined study of 33 cases (Bologna-Marseille). Acta Neurochir 42:177–181
23.
go back to reference Frank F, Fabrizi AP, Frank-Ricci R, Gaist G, Sédan R, Peragut JC (1988) Stereotactic biopsy and treatment of brainstem lesions: combined study of 33 cases (Bologna-Marseille). Acta Neurochir Suppl (Wien) 42:177–181 Frank F, Fabrizi AP, Frank-Ricci R, Gaist G, Sédan R, Peragut JC (1988) Stereotactic biopsy and treatment of brainstem lesions: combined study of 33 cases (Bologna-Marseille). Acta Neurochir Suppl (Wien) 42:177–181
24.
go back to reference Frazier JL, Lee J, Thomale UW, Noggle JC, Cohen KJ, Jallo G (2009) Treatment of diffuse intrinsic brainstem gliomas: failed approaches and futures strategies. J Neurosurg Pediatr 3:259–269CrossRef Frazier JL, Lee J, Thomale UW, Noggle JC, Cohen KJ, Jallo G (2009) Treatment of diffuse intrinsic brainstem gliomas: failed approaches and futures strategies. J Neurosurg Pediatr 3:259–269CrossRef
25.
go back to reference Giese H, Hoffmann KT, Winkelmann A, Stockhammer F, Jallo GI, Thomale UW (2010) Precision of navigated stereotactic probe implantation into the brainstem. J Neurosurg Pediatr 5(4):350–359CrossRefPubMed Giese H, Hoffmann KT, Winkelmann A, Stockhammer F, Jallo GI, Thomale UW (2010) Precision of navigated stereotactic probe implantation into the brainstem. J Neurosurg Pediatr 5(4):350–359CrossRefPubMed
26.
go back to reference Golfinos JG, Fitzpatrick BC, Smith LR, Spetzler RF (1995) Clinical use of a frameless stereotactic arm: results of 325 cases. J Neurosurg 1983:197–205CrossRef Golfinos JG, Fitzpatrick BC, Smith LR, Spetzler RF (1995) Clinical use of a frameless stereotactic arm: results of 325 cases. J Neurosurg 1983:197–205CrossRef
27.
go back to reference Gralla J, Nimsky C, Buchfelder M, Fahlbusch R, Ganslandt O (2003) Frameless stereotactic brain biopsy procedures using the Stealth Station: indications, accuracy and results. Zentralbl Neurochir 64:166–170CrossRefPubMed Gralla J, Nimsky C, Buchfelder M, Fahlbusch R, Ganslandt O (2003) Frameless stereotactic brain biopsy procedures using the Stealth Station: indications, accuracy and results. Zentralbl Neurochir 64:166–170CrossRefPubMed
28.
go back to reference Grimm F, Naros G, Gutenberg A, Keric N, Giese A, Gharabaghi A (2015) Blurring the boundaries between frame-based and frameless stereotaxy: feasibility study for brain biopsies performed with the use of a head-mounted robot. J Neurosurg 123:737–742CrossRefPubMed Grimm F, Naros G, Gutenberg A, Keric N, Giese A, Gharabaghi A (2015) Blurring the boundaries between frame-based and frameless stereotaxy: feasibility study for brain biopsies performed with the use of a head-mounted robot. J Neurosurg 123:737–742CrossRefPubMed
29.
go back to reference Grossman R, Sadetzki S, Spiegelmann R, Ram Z (2005) Haemorrhagic complications and the incidence of asymptomatic bleeding associated with stereotactic brain biopsies. Acta Neurochir 147:627–631CrossRefPubMed Grossman R, Sadetzki S, Spiegelmann R, Ram Z (2005) Haemorrhagic complications and the incidence of asymptomatic bleeding associated with stereotactic brain biopsies. Acta Neurochir 147:627–631CrossRefPubMed
30.
go back to reference Guthrie BL, Steinberg GK, Adler JR (1989) Posterior fossa stereotaxic biopsy using the Brown-Roberts-Wells stereotaxic system. Neurosurgery 70:649–652CrossRef Guthrie BL, Steinberg GK, Adler JR (1989) Posterior fossa stereotaxic biopsy using the Brown-Roberts-Wells stereotaxic system. Neurosurgery 70:649–652CrossRef
31.
go back to reference Guy G, Jan M, Guégan Y, Aubin ML, Fischer C, Ben-Hassel M (1989) Surgical lesions of the brain stem. Neurochirurgie 1(35):1–133 Guy G, Jan M, Guégan Y, Aubin ML, Fischer C, Ben-Hassel M (1989) Surgical lesions of the brain stem. Neurochirurgie 1(35):1–133
32.
go back to reference Haegelen C, Touzet G, Reyns N, Maurage CA, Ayachi M, Blond S (2010) Stereotactic robot-guided biopsies of brain stem lesions: experience with 15 cases. Neurochirurgie 56:363–367CrossRefPubMed Haegelen C, Touzet G, Reyns N, Maurage CA, Ayachi M, Blond S (2010) Stereotactic robot-guided biopsies of brain stem lesions: experience with 15 cases. Neurochirurgie 56:363–367CrossRefPubMed
33.
go back to reference Hood TW, Gebarski SS, McKeever PE, Venes JL (1986) Stereotaxic biopsy of intrinsic lesions of the brain stem. J Neurosurg 65:172–176CrossRefPubMed Hood TW, Gebarski SS, McKeever PE, Venes JL (1986) Stereotaxic biopsy of intrinsic lesions of the brain stem. J Neurosurg 65:172–176CrossRefPubMed
34.
go back to reference Lefranc M, Touzet G, Caron S, Maurage CA, Assaker R, Blond S (2011) Are stereotactic sample biopsies still of value in the modern management of pineal region tumours? Lessons from a single-department, retrospective series. Acta Neurochir 153:1111–1122CrossRefPubMed Lefranc M, Touzet G, Caron S, Maurage CA, Assaker R, Blond S (2011) Are stereotactic sample biopsies still of value in the modern management of pineal region tumours? Lessons from a single-department, retrospective series. Acta Neurochir 153:1111–1122CrossRefPubMed
35.
go back to reference Lefranc M, Capel C, Pruvot AS, Fichten A, Desenclos C, Toussaint P (2014) The impact of the reference imaging modality, registration method and intraoperative flat-panel computed tomography on the accuracy of the ROSA® stereotactic robot. Stereotact Funct Neurosurg 92:242–250CrossRefPubMed Lefranc M, Capel C, Pruvot AS, Fichten A, Desenclos C, Toussaint P (2014) The impact of the reference imaging modality, registration method and intraoperative flat-panel computed tomography on the accuracy of the ROSA® stereotactic robot. Stereotact Funct Neurosurg 92:242–250CrossRefPubMed
36.
go back to reference Lefranc M, Capel C, Pruvot-Occean AS, Fichten A, Desenclos C, Toussaint P (2015) Frameless robotic stereotactic biopsies: a consecutive series of 100 cases. J Neurosurg 122(2):342–352CrossRefPubMed Lefranc M, Capel C, Pruvot-Occean AS, Fichten A, Desenclos C, Toussaint P (2015) Frameless robotic stereotactic biopsies: a consecutive series of 100 cases. J Neurosurg 122(2):342–352CrossRefPubMed
37.
go back to reference Louis DN, Ohgaki H, Wiestler OD, Cavenee WK (2016) World Health Organization histological classification of tumours of the central nervous system 2016. International Agency for Research on Cancer, France Louis DN, Ohgaki H, Wiestler OD, Cavenee WK (2016) World Health Organization histological classification of tumours of the central nervous system 2016. International Agency for Research on Cancer, France
38.
go back to reference Nathoo N, Cavuşoğlu MC, Vogelbaum MA, Barnett GH (2005) In touch with robotics: neurosurgery for the future. Neurosurgery 56:421–433CrossRefPubMed Nathoo N, Cavuşoğlu MC, Vogelbaum MA, Barnett GH (2005) In touch with robotics: neurosurgery for the future. Neurosurgery 56:421–433CrossRefPubMed
39.
go back to reference Rachinger W, Grau S, Holtmannspötter M (2009) Serial stereotactic biopsy of brainstem lesions in adults improves diagnostic accuracy compared with MRI only. J Neurol Neurosurg Psychiatry 80:1134–1139CrossRef Rachinger W, Grau S, Holtmannspötter M (2009) Serial stereotactic biopsy of brainstem lesions in adults improves diagnostic accuracy compared with MRI only. J Neurol Neurosurg Psychiatry 80:1134–1139CrossRef
40.
go back to reference Rajshekhar V, Chandy MJ (1995) Computerized tomography-guided stereotactic surgery for brain stem masses: a risk-benefit analysis of 71 patients. J Neurosurg 8:976–981CrossRef Rajshekhar V, Chandy MJ (1995) Computerized tomography-guided stereotactic surgery for brain stem masses: a risk-benefit analysis of 71 patients. J Neurosurg 8:976–981CrossRef
41.
go back to reference Regis J, Bouillot P, Rouby-Volot F, Figarella-Branger D, Dufour H, Peragut J (1996) Pineal region tumours and the role of stereotactic biopsy: review of the mortality, morbidity, and diagnostic rates in 370 cases. Neurosurgery 39(5):907–914PubMed Regis J, Bouillot P, Rouby-Volot F, Figarella-Branger D, Dufour H, Peragut J (1996) Pineal region tumours and the role of stereotactic biopsy: review of the mortality, morbidity, and diagnostic rates in 370 cases. Neurosurgery 39(5):907–914PubMed
42.
go back to reference Roessler K, Ungersboeck K, Aichholzer M, Dietrich W, Goerzer H, Matula C (1998) Frameless stereotactic lesion contour-guided surgery using a computer-navigated microscope. Surg Neurol 49:282–289CrossRefPubMed Roessler K, Ungersboeck K, Aichholzer M, Dietrich W, Goerzer H, Matula C (1998) Frameless stereotactic lesion contour-guided surgery using a computer-navigated microscope. Surg Neurol 49:282–289CrossRefPubMed
43.
go back to reference Roujeau T, Machado G, Garnett MR, Miquel C, Puget S (2007) Stereotactic biopsy of diffuse pontine lesions in children. J Neurosurg 107(1):1–4CrossRef Roujeau T, Machado G, Garnett MR, Miquel C, Puget S (2007) Stereotactic biopsy of diffuse pontine lesions in children. J Neurosurg 107(1):1–4CrossRef
44.
go back to reference Samadani U, Stein S, Moonis G, Sonnad SS, Bonura P, Judy K (2006) Stereotactic biopsy of brain stem masses: decision analysis and literature review. Surg Neurol 66:484–491CrossRefPubMed Samadani U, Stein S, Moonis G, Sonnad SS, Bonura P, Judy K (2006) Stereotactic biopsy of brain stem masses: decision analysis and literature review. Surg Neurol 66:484–491CrossRefPubMed
45.
go back to reference Smith JS, Quiñones-Hinojosa A, Barbaro NM, McDermott MW (2005) Frame-based stereotactic biopsy remains an important diagnostic tool with distinct advantages over frameless stereotactic biopsy. J Neuro-Oncol 73:173–179CrossRef Smith JS, Quiñones-Hinojosa A, Barbaro NM, McDermott MW (2005) Frame-based stereotactic biopsy remains an important diagnostic tool with distinct advantages over frameless stereotactic biopsy. J Neuro-Oncol 73:173–179CrossRef
46.
go back to reference St George EJ, Walsh AR, Sgouros S (2004) Stereotactic biopsy of brain tumours in the paediatric population. Childs Nerv Syst 20:163–167CrossRefPubMed St George EJ, Walsh AR, Sgouros S (2004) Stereotactic biopsy of brain tumours in the paediatric population. Childs Nerv Syst 20:163–167CrossRefPubMed
47.
go back to reference Sutherland GR, Lama S, Gan LS, Wolfsberger S, Zereinia K (2013) Merging machines with microsurgery: clinical experience with neuroArm. J Neurosurg 118:521–529CrossRefPubMed Sutherland GR, Lama S, Gan LS, Wolfsberger S, Zereinia K (2013) Merging machines with microsurgery: clinical experience with neuroArm. J Neurosurg 118:521–529CrossRefPubMed
48.
go back to reference Ulm AJ, Bova FJ, Friedman WA (2001) Stereotactic biopsy aided by a computer graphics workstation: experience with 200 consecutive cases. Surg Neurol 56:366–372CrossRefPubMed Ulm AJ, Bova FJ, Friedman WA (2001) Stereotactic biopsy aided by a computer graphics workstation: experience with 200 consecutive cases. Surg Neurol 56:366–372CrossRefPubMed
49.
go back to reference Woodworth GF, McGirt MJ, Samdani A, Garonzik I, Olivi A, Weingart JD (2006) Frameless image-guided stereotactic brain biopsy procedure: diagnostic yield, surgical morbidity, and comparison with the frame-based technique. J Neurosurg 104:233–237CrossRefPubMed Woodworth GF, McGirt MJ, Samdani A, Garonzik I, Olivi A, Weingart JD (2006) Frameless image-guided stereotactic brain biopsy procedure: diagnostic yield, surgical morbidity, and comparison with the frame-based technique. J Neurosurg 104:233–237CrossRefPubMed
50.
go back to reference Zamorano L, Li Q, Jain S, Kaur G (2004) Robotics in neurosurgery: state of the art and future technological challenges. Int J Med Robot Comput Assist Surg 1(1):7–22CrossRef Zamorano L, Li Q, Jain S, Kaur G (2004) Robotics in neurosurgery: state of the art and future technological challenges. Int J Med Robot Comput Assist Surg 1(1):7–22CrossRef
Metadata
Title
Stereotactic brain biopsy: evaluation of robot-assisted procedure in 60 patients
Authors
Laura Terrier
Vianney Gilard
Florent Marguet
Maxime Fontanilles
Stéphane Derrey
Publication date
01-03-2019
Publisher
Springer Vienna
Published in
Acta Neurochirurgica / Issue 3/2019
Print ISSN: 0001-6268
Electronic ISSN: 0942-0940
DOI
https://doi.org/10.1007/s00701-019-03808-5

Other articles of this Issue 3/2019

Acta Neurochirurgica 3/2019 Go to the issue

Original Article - Brain Tumors

Influence of pregnancy on glioma patients