Background

Achieving an optimal limb alignment is an important factor affecting the long-term survival of total knee arthroplasty (TKA). This is the first study to look at the limb alignment and orientation of components in TKA using a novel image-free handheld robotic sculpting system.

Methods

This case-controlled study retrospectively compared limb and component alignment of 77 TKAs performed with a robot (Robot-group) with a matched control group of patients who received conventional alignment with intramedular rods (Control group). Alignment and component positioning was measured on full-leg weight-bearing and standard lateral X-rays by two independent observers. The image-free handheld robotic sculpting system calculated the planned and achieved mechanical axis (MA). Outliers were defined as > 3° deviation from planned alignment.

Results

Mean MA was 180.1° (SD = 1.9) in the Robot-group, compared to the Control group with a mean MA of 179.1° (SD = 3.1, p = 0.028). We observed 5 outliers (6%) in the Robot-group and 14 outliers (18%, p = 0.051) in the Control group. Fraction of outliers of the frontal tibial component was 0% in the Robot-group versus 8% in the Control group (p = 0.038). There were no other statistical differences regarding the implant positioning between both groups.

Conclusion

The Robot-group showed significantly less outliers compared to the conventional technique. Whether these differences are clinically relevant is questionable and should be investigated on the long term. Randomized controlled trials with larger patient series will be needed in the future to confirm our preliminary results.
Literature
4.
go back to reference Lotke PA, Ecker ML (1977) Influence of positioning of prosthesis in total knee replacement. J Bone Joint Surg Am 59(1):77–79CrossRefPubMed Lotke PA, Ecker ML (1977) Influence of positioning of prosthesis in total knee replacement. J Bone Joint Surg Am 59(1):77–79CrossRefPubMed
7.
go back to reference Ritter MA, Faris PM, Keating EM, Meding JB (1994) Postoperative alignment of total knee replacement. Its effect on survival. Clin Orthop Relat Res 299:153–156 Ritter MA, Faris PM, Keating EM, Meding JB (1994) Postoperative alignment of total knee replacement. Its effect on survival. Clin Orthop Relat Res 299:153–156
8.
go back to reference Jeffery RS, Morris RW, Denham RA (1991) Coronal alignment after total knee replacement. J Bone Joint Surg Br 73(5):709–714CrossRefPubMed Jeffery RS, Morris RW, Denham RA (1991) Coronal alignment after total knee replacement. J Bone Joint Surg Br 73(5):709–714CrossRefPubMed
9.
go back to reference Bargren JH, Blaha JD, Freeman MA (1983) Alignment in total knee arthroplasty. Correlated biomechanical and clinical observations. Clin Orthop Relat Res 173:178–183 Bargren JH, Blaha JD, Freeman MA (1983) Alignment in total knee arthroplasty. Correlated biomechanical and clinical observations. Clin Orthop Relat Res 173:178–183
17.
go back to reference (2013) World Medical Association Declaration of Helsinki. JAMA 310 (20):2191 (2013) World Medical Association Declaration of Helsinki. JAMA 310 (20):2191
18.
go back to reference Kazis LE, Anderson JJ, Meenan RF (1989) Effect sizes for interpreting changes in health status. Med Care 27(3 Suppl):S178–189CrossRefPubMed Kazis LE, Anderson JJ, Meenan RF (1989) Effect sizes for interpreting changes in health status. Med Care 27(3 Suppl):S178–189CrossRefPubMed
19.
go back to reference Insall JN, Binazzi R, Soudry M, Mestriner LA (1985) Total knee arthroplasty. Clin Orthop Relat Res 192:13–22 Insall JN, Binazzi R, Soudry M, Mestriner LA (1985) Total knee arthroplasty. Clin Orthop Relat Res 192:13–22
21.
32.
go back to reference Schmidt GL, Altman GT, Dougherty JT, DeMeo PJ (2004) Reproducibility and reliability of the anatomic axis of the lower extremity. J Knee Surg 17(3):141–143PubMed Schmidt GL, Altman GT, Dougherty JT, DeMeo PJ (2004) Reproducibility and reliability of the anatomic axis of the lower extremity. J Knee Surg 17(3):141–143PubMed
34.
go back to reference Boonen B, Schotanus MGM, Kerens B, Hulsmans FJ, Tuinebreijer WE, Kort NP (2017) Patient-specific positioning guides for total knee arthroplasty: no significant difference between final component alignment and pre-operative digital plan except for tibial rotation. Knee Surg Sports Traumatol Arthrosc 25(9):2809–2817. https://doi.org/10.1007/s00167-015-3661-1 CrossRefPubMed Boonen B, Schotanus MGM, Kerens B, Hulsmans FJ, Tuinebreijer WE, Kort NP (2017) Patient-specific positioning guides for total knee arthroplasty: no significant difference between final component alignment and pre-operative digital plan except for tibial rotation. Knee Surg Sports Traumatol Arthrosc 25(9):2809–2817. https://​doi.​org/​10.​1007/​s00167-015-3661-1 CrossRefPubMed
Metadata
Title
Preliminary experience with an image-free handheld robot for total knee arthroplasty: 77 cases compared with a matched control group
Authors
P. Bollars
A. Boeckxstaens
J. Mievis
S. Kalaai
M. G. M. Schotanus
D. Janssen
Publication date
01-05-2020
Publisher
Springer Paris
Published in
European Journal of Orthopaedic Surgery & Traumatology / Issue 4/2020
Print ISSN: 1633-8065
Electronic ISSN: 1432-1068
DOI
https://doi.org/10.1007/s00590-020-02624-3

Other articles of this Issue 4/2020

European Journal of Orthopaedic Surgery & Traumatology 4/2020 Go to the issue