Skip to main content
Top
Published in: European Spine Journal 11/2011

01-11-2011 | Original Article

Anterior single screw fixation of odontoid fracture with intraoperative iso-C 3-dimensional imaging

Authors: Yong Liang Yang, Bai Sheng Fu, Rachel W. Li, Paul N. Smith, Wei Dong Mu, Lian Xin Li, Dong Sheng Zhou

Published in: European Spine Journal | Issue 11/2011

Login to get access

Abstract

Purpose

The purpose of this study was to assess the value of isocentric C-arm three-dimensional (Iso-C 3D) fluoroscopy for the insertion of an anterior odontoid screw. The results of the Iso-C 3D group were compared with that of an historic control group using conventional fluoroscopy.

Methods

Twenty-nine patients diagnosed with type II or rostral-type III odontoid fractures were treated with a single anterior screw fixation in this study. The Iso-C 3D group included 13 patients and the other 16 patients were in the historic control group. All operations were performed by a single surgeon using standard procedure and manner. The clinical and radiographic results were recorded and compared between the two groups.

Results

The fluoroscopy time in the Iso-C 3D group was 42.9 s as compared to 68.1 s in the control group (P < 0.01). The mean operative time was 91.5 min in the Iso-C 3D group when compared with 81.6 min in the control group (P = 0.20). The rate of bony fusion was 96.6% (28/29), the failure rate of reduction or fixation was 13.8% (7.7% in Iso-C 3D group; 18.8% in control group). The Smiley–Webster scale showed that 90% of patients achieved good or better outcomes

Conclusions

In conclusion, this technique can be safely extended to the treatment of technically difficult to treat spinal injuries and at the same time reduce total radiation exposure time both for the patient and the surgeon.
Literature
1.
go back to reference Bohler J (1981) Screw-osteosynthesis of fractures of the dens axis (author’s transl). Unfallheilkunde 84:221–223PubMed Bohler J (1981) Screw-osteosynthesis of fractures of the dens axis (author’s transl). Unfallheilkunde 84:221–223PubMed
2.
go back to reference Anderson LD, D’Alonzo RT (2004) Fractures of the odontoid process of the axis. J Bone Joint Surg Am 86-A:2081 Anderson LD, D’Alonzo RT (2004) Fractures of the odontoid process of the axis. J Bone Joint Surg Am 86-A:2081
3.
go back to reference Subach BR, Morone MA, Haid RW Jr, McLaughlin MR, Rodts GR, Comey CH (1999) Management of acute odontoid fractures with single-screw anterior fixation. Neurosurgery 45:812–819 (discussion 9–20) Subach BR, Morone MA, Haid RW Jr, McLaughlin MR, Rodts GR, Comey CH (1999) Management of acute odontoid fractures with single-screw anterior fixation. Neurosurgery 45:812–819 (discussion 9–20)
4.
go back to reference Nourbakhsh A, Shi R, Vannemreddy P, Nanda A (2009) Operative versus nonoperative management of acute odontoid type II fractures: a meta-analysis. J Neurosurg Spine 11:651–658PubMedCrossRef Nourbakhsh A, Shi R, Vannemreddy P, Nanda A (2009) Operative versus nonoperative management of acute odontoid type II fractures: a meta-analysis. J Neurosurg Spine 11:651–658PubMedCrossRef
5.
go back to reference Fountas KN, Kapsalaki EZ, Karampelas I, Feltes CH, Dimopoulos VG, Machinis TG, Nikolakakos LG, Boev AN, 3rd, Choudhri H, Smisson HF, Robinson JS (2005) Results of long-term follow-up in patients undergoing anterior screw fixation for type II and rostral type III odontoid fractures. Spine (Phila Pa 1976) 30:661–669 Fountas KN, Kapsalaki EZ, Karampelas I, Feltes CH, Dimopoulos VG, Machinis TG, Nikolakakos LG, Boev AN, 3rd, Choudhri H, Smisson HF, Robinson JS (2005) Results of long-term follow-up in patients undergoing anterior screw fixation for type II and rostral type III odontoid fractures. Spine (Phila Pa 1976) 30:661–669
6.
go back to reference Borm W, Konig RW, Albrecht A, Richter HP, Kast E (2004) Percutaneous transarticular atlantoaxial screw fixation using a cannulated screw system and image guidance. Minim Invasive Neurosurg 47:111–114PubMedCrossRef Borm W, Konig RW, Albrecht A, Richter HP, Kast E (2004) Percutaneous transarticular atlantoaxial screw fixation using a cannulated screw system and image guidance. Minim Invasive Neurosurg 47:111–114PubMedCrossRef
7.
go back to reference Sanders R, Koval KJ, DiPasquale T, Schmelling G, Stenzler S, Ross E (1993) Exposure of the orthopaedic surgeon to radiation. J Bone Joint Surg Am 75:326–330PubMed Sanders R, Koval KJ, DiPasquale T, Schmelling G, Stenzler S, Ross E (1993) Exposure of the orthopaedic surgeon to radiation. J Bone Joint Surg Am 75:326–330PubMed
8.
go back to reference Rampersaud YR, Foley KT, Shen AC, Williams S, Solomito M (2000) Radiation exposure to the spine surgeon during fluoroscopically assisted pedicle screw insertion. Spine (Phila Pa 1976) 25:2637–2645 Rampersaud YR, Foley KT, Shen AC, Williams S, Solomito M (2000) Radiation exposure to the spine surgeon during fluoroscopically assisted pedicle screw insertion. Spine (Phila Pa 1976) 25:2637–2645
9.
go back to reference Rajasekaran S, Vidyadhara S, Ramesh P, Shetty AP (2007) Randomized clinical study to compare the accuracy of navigated and non-navigated thoracic pedicle screws in deformity correction surgeries. Spine (Phila Pa 1976) 32: E56–E64 Rajasekaran S, Vidyadhara S, Ramesh P, Shetty AP (2007) Randomized clinical study to compare the accuracy of navigated and non-navigated thoracic pedicle screws in deformity correction surgeries. Spine (Phila Pa 1976) 32: E56–E64
10.
go back to reference Gebhard FT, Kraus MD, Schneider E, Liener UC, Kinzl L, Arand M (2006) Does computer-assisted spine surgery reduce intraoperative radiation doses? Spine (Phila Pa 1976) 31:2024–2027 (discussion 8) Gebhard FT, Kraus MD, Schneider E, Liener UC, Kinzl L, Arand M (2006) Does computer-assisted spine surgery reduce intraoperative radiation doses? Spine (Phila Pa 1976) 31:2024–2027 (discussion 8)
11.
go back to reference Summers LE, Kouri JG, Yang M, Patrick Jacob R (2008) Odontoid screw placement using isocentric 3-dimensional C-arm fluoroscopy. J Spinal Disord Tech 21:45–48PubMedCrossRef Summers LE, Kouri JG, Yang M, Patrick Jacob R (2008) Odontoid screw placement using isocentric 3-dimensional C-arm fluoroscopy. J Spinal Disord Tech 21:45–48PubMedCrossRef
12.
go back to reference Shetty A, Kini AR, Prabhu J (2009) Odontoid fractures: a retrospective analysis of 53 cases. Indian J Orthop 43:352–360PubMedCrossRef Shetty A, Kini AR, Prabhu J (2009) Odontoid fractures: a retrospective analysis of 53 cases. Indian J Orthop 43:352–360PubMedCrossRef
13.
go back to reference Aebi M, Etter C, Coscia M (1989) Fractures of the odontoid process. Treatment with anterior screw fixation. Spine (Phila Pa 1976) 14:1065–70 Aebi M, Etter C, Coscia M (1989) Fractures of the odontoid process. Treatment with anterior screw fixation. Spine (Phila Pa 1976) 14:1065–70
14.
go back to reference Martin GJ Jr, Haid RW Jr, MacMillan M, Rodts GE Jr, Berkman R (1999) Anterior cervical discectomy with freeze-dried fibula allograft. Overview of 317 cases and literature review. Spine (Phila Pa 1976) 24:852–858 (discussion 8–9) Martin GJ Jr, Haid RW Jr, MacMillan M, Rodts GE Jr, Berkman R (1999) Anterior cervical discectomy with freeze-dried fibula allograft. Overview of 317 cases and literature review. Spine (Phila Pa 1976) 24:852–858 (discussion 8–9)
15.
go back to reference Song KJ, Lee KB, Kim KN (2007) Treatment of odontoid fractures with single anterior screw fixation. J Clin Neurosci 14:824–830PubMedCrossRef Song KJ, Lee KB, Kim KN (2007) Treatment of odontoid fractures with single anterior screw fixation. J Clin Neurosci 14:824–830PubMedCrossRef
16.
go back to reference Tuli SK, Chen P, Eichler ME, Woodard EJ (2004) Reliability of radiologic assessment of fusion: cervical fibular allograft model. Spine (Phila Pa 1976) 29:856–860 Tuli SK, Chen P, Eichler ME, Woodard EJ (2004) Reliability of radiologic assessment of fusion: cervical fibular allograft model. Spine (Phila Pa 1976) 29:856–860
17.
go back to reference Webster FS, Smiley DP (1960) End result study of a series of operations for herniated intervertebral lumbar discs. Am J Surg 99:27–32PubMedCrossRef Webster FS, Smiley DP (1960) End result study of a series of operations for herniated intervertebral lumbar discs. Am J Surg 99:27–32PubMedCrossRef
18.
go back to reference Julien TD, Frankel B, Traynelis VC, Ryken TC (2000) Evidence-based analysis of odontoid fracture management. Neurosurg Focus 8:e1PubMedCrossRef Julien TD, Frankel B, Traynelis VC, Ryken TC (2000) Evidence-based analysis of odontoid fracture management. Neurosurg Focus 8:e1PubMedCrossRef
19.
go back to reference Muller EJ, Wick M, Russe O, Muhr G (1999) Management of odontoid fractures in the elderly. Eur Spine J 8:360–365PubMedCrossRef Muller EJ, Wick M, Russe O, Muhr G (1999) Management of odontoid fractures in the elderly. Eur Spine J 8:360–365PubMedCrossRef
20.
go back to reference Richter M, Geerling J, Zech S, Goesling T, Krettek C (2005) Intraoperative three-dimensional imaging with a motorized mobile C-arm (SIREMOBIL ISO-C-3D) in foot and ankle trauma care: a preliminary report. J Orthop Trauma 19:259–266PubMedCrossRef Richter M, Geerling J, Zech S, Goesling T, Krettek C (2005) Intraoperative three-dimensional imaging with a motorized mobile C-arm (SIREMOBIL ISO-C-3D) in foot and ankle trauma care: a preliminary report. J Orthop Trauma 19:259–266PubMedCrossRef
21.
go back to reference Nakashima H, Sato K, Ando T, Inoh H, Nakamura H (2009) Comparison of the percutaneous screw placement precision of isocentric C-arm 3-dimensional fluoroscopy-navigated pedicle screw implantation and conventional fluoroscopy method with minimally invasive surgery. J Spinal Disord Tech 22:468–472PubMedCrossRef Nakashima H, Sato K, Ando T, Inoh H, Nakamura H (2009) Comparison of the percutaneous screw placement precision of isocentric C-arm 3-dimensional fluoroscopy-navigated pedicle screw implantation and conventional fluoroscopy method with minimally invasive surgery. J Spinal Disord Tech 22:468–472PubMedCrossRef
22.
go back to reference Zwingmann J, Konrad G, Kotter E, Sudkamp NP, Oberst M (2009) Computer-navigated iliosacral screw insertion reduces malposition rate and radiation exposure. Clin Orthop Relat Res 467:1833–1838PubMedCrossRef Zwingmann J, Konrad G, Kotter E, Sudkamp NP, Oberst M (2009) Computer-navigated iliosacral screw insertion reduces malposition rate and radiation exposure. Clin Orthop Relat Res 467:1833–1838PubMedCrossRef
23.
go back to reference Smith HE, Welsch MD, Sasso RC, Vaccaro AR (2008) Comparison of radiation exposure in lumbar pedicle screw placement with fluoroscopy vs computer-assisted image guidance with intraoperative three-dimensional imaging. J Spinal Cord Med 31:532–537PubMed Smith HE, Welsch MD, Sasso RC, Vaccaro AR (2008) Comparison of radiation exposure in lumbar pedicle screw placement with fluoroscopy vs computer-assisted image guidance with intraoperative three-dimensional imaging. J Spinal Cord Med 31:532–537PubMed
24.
go back to reference Citak M, Kendoff D, Kfuri M Jr, Pearle A, Krettek C, Hufner T (2007) Accuracy analysis of Iso-C3D versus fluoroscopy-based navigated retrograde drilling of osteochondral lesions: a pilot study. J Bone Joint Surg Br 89:323–326PubMedCrossRef Citak M, Kendoff D, Kfuri M Jr, Pearle A, Krettek C, Hufner T (2007) Accuracy analysis of Iso-C3D versus fluoroscopy-based navigated retrograde drilling of osteochondral lesions: a pilot study. J Bone Joint Surg Br 89:323–326PubMedCrossRef
25.
go back to reference Luo CF, Zhou KH, Gao H, Hu CF, Chen J, Zeng BF (2007) Minimally invasive surgery of pelvic-acetabular fractures with fluoro-navigation. Zhonghua Yi Xue Za Zhi 87:3030–3034PubMed Luo CF, Zhou KH, Gao H, Hu CF, Chen J, Zeng BF (2007) Minimally invasive surgery of pelvic-acetabular fractures with fluoro-navigation. Zhonghua Yi Xue Za Zhi 87:3030–3034PubMed
26.
go back to reference Melamed H, Harris MB, Awasthi D (2002) Anatomic considerations of superior laryngeal nerve during anterior cervical spine procedures. Spine (Phila Pa 1976) 27:E83–E86 Melamed H, Harris MB, Awasthi D (2002) Anatomic considerations of superior laryngeal nerve during anterior cervical spine procedures. Spine (Phila Pa 1976) 27:E83–E86
27.
go back to reference Atesok K, Finkelstein J, Khoury A, Peyser A, Weil Y, Liebergall M, Mosheiff R (2007) The use of intraoperative three-dimensional imaging (ISO-C-3D) in fixation of intraarticular fractures. Injury 38:1163–1169PubMedCrossRef Atesok K, Finkelstein J, Khoury A, Peyser A, Weil Y, Liebergall M, Mosheiff R (2007) The use of intraoperative three-dimensional imaging (ISO-C-3D) in fixation of intraarticular fractures. Injury 38:1163–1169PubMedCrossRef
Metadata
Title
Anterior single screw fixation of odontoid fracture with intraoperative iso-C 3-dimensional imaging
Authors
Yong Liang Yang
Bai Sheng Fu
Rachel W. Li
Paul N. Smith
Wei Dong Mu
Lian Xin Li
Dong Sheng Zhou
Publication date
01-11-2011
Publisher
Springer-Verlag
Published in
European Spine Journal / Issue 11/2011
Print ISSN: 0940-6719
Electronic ISSN: 1432-0932
DOI
https://doi.org/10.1007/s00586-011-1860-0

Other articles of this Issue 11/2011

European Spine Journal 11/2011 Go to the issue