Skip to main content
Top
Published in: European Spine Journal 11/2011

01-11-2011 | Original Article

Effect of the cord pretension of the Dynesys dynamic stabilisation system on the biomechanics of the lumbar spine: a finite element analysis

Authors: Chien-Lin Liu, Zheng-Cheng Zhong, Hung-Wei Hsu, Shih-Liang Shih, Shih-Tien Wang, Chinghua Hung, Chen-Sheng Chen

Published in: European Spine Journal | Issue 11/2011

Login to get access

Abstract

The Dynesys dynamics stabilisation system was developed to maintain the mobility of motion segment of the lumbar spine in order to reduce the incidence of negative effects at the adjacent segments. However, the magnitude of cord pretension may change the stiffness of the Dynesys system and result in a diverse clinical outcome, and the effects of Dynesys cord pretension remain unclear. Displacement-controlled finite element analysis was used to evaluate the biomechanical behaviour of the lumbar spine after insertion of Dynesys with three different cord pretensions. For the implanted level, increasing the cord pretension from 100 to 300 N resulted in an increase in flexion stiffness from 19.0 to 64.5 Nm/deg, a marked increase in facet contact force (FCF) of 35% in extension and 32% in torsion, a 40% increase of the annulus stress in torsion, and an increase in the high-stress region of the pedicle screw in flexion and lateral bending. For the adjacent levels, varying the cord pretension from 100 to 300 N only had a minor influence on range of motion (ROM), FCF, and annulus stress, with changes of 6, 12, and 9%, respectively. This study found that alteration of cord pretension affects the ROM and FCF, and annulus stress within the construct but not the adjacent segment. In addition, use of a 300 N cord pretension causes a much higher stiffness at the implanted level when compared with the intact lumbar spine.
Literature
1.
go back to reference Mulholland RC, Sengupta DK (2002) Rationale, principles and experimental evaluation of the concept of soft stabilization. Eur Spine J 11:S198–S205PubMed Mulholland RC, Sengupta DK (2002) Rationale, principles and experimental evaluation of the concept of soft stabilization. Eur Spine J 11:S198–S205PubMed
2.
go back to reference Mayer HM, Korge A (2002) Non-fusion technology in degenerative lumbar spinal disorders: facts, questions, challenges. Eur Spine J 11:85–91 Mayer HM, Korge A (2002) Non-fusion technology in degenerative lumbar spinal disorders: facts, questions, challenges. Eur Spine J 11:85–91
3.
go back to reference Grob D, Benini A, Junge A, Mannion AF (2005) Clinical experience with the Dynesys semirigid fixation system for the lumbar spine. Spine 30:324–331PubMedCrossRef Grob D, Benini A, Junge A, Mannion AF (2005) Clinical experience with the Dynesys semirigid fixation system for the lumbar spine. Spine 30:324–331PubMedCrossRef
4.
go back to reference Stoll TM, Dubois G, Schwarzenbach O (2002) The dynamic neutralization system for the spine: a multi-center study of a novel non-fusion system. Eur Spine J 11:S170–S178PubMed Stoll TM, Dubois G, Schwarzenbach O (2002) The dynamic neutralization system for the spine: a multi-center study of a novel non-fusion system. Eur Spine J 11:S170–S178PubMed
5.
go back to reference Vaga S, Brayda-Bruno M, Perona F, Fornari M, Raimondi MT, Petruzzi M, Grava G, Costa F, Caiani EG, Lamartina C (2009) Molecular MR imaging for the evaluation of the effect of dynamic stabilization on lumbar intervertebral discs. Eur Spine J 18:S40–S48CrossRef Vaga S, Brayda-Bruno M, Perona F, Fornari M, Raimondi MT, Petruzzi M, Grava G, Costa F, Caiani EG, Lamartina C (2009) Molecular MR imaging for the evaluation of the effect of dynamic stabilization on lumbar intervertebral discs. Eur Spine J 18:S40–S48CrossRef
6.
go back to reference Schaeren S, Broger I, Jeanneret B (2008) Minimum four-year follow-up of spinal stenosis with degenerative spondylolisthesis treated with decompression and dynamic stabilization. Spine 33:E636–E642PubMedCrossRef Schaeren S, Broger I, Jeanneret B (2008) Minimum four-year follow-up of spinal stenosis with degenerative spondylolisthesis treated with decompression and dynamic stabilization. Spine 33:E636–E642PubMedCrossRef
7.
go back to reference Würgler-Hauri CC, Kalbarczyk A, Wiesli M, Landolt H, Fandino J (2008) Dynamic neutralization of the lumbar spine after microsurgical decompression in acquired lumbar spinal stenosis and segmental instability. Spine 33:E66–E72PubMedCrossRef Würgler-Hauri CC, Kalbarczyk A, Wiesli M, Landolt H, Fandino J (2008) Dynamic neutralization of the lumbar spine after microsurgical decompression in acquired lumbar spinal stenosis and segmental instability. Spine 33:E66–E72PubMedCrossRef
8.
go back to reference Freudiger S, Dubios G, Lorrain M (1999) Dynamic neutralization of the lumbar spine confirmed on a new lumbar spine simulator in vitro. Arch Orthop Trauma Surg 199:127–132CrossRef Freudiger S, Dubios G, Lorrain M (1999) Dynamic neutralization of the lumbar spine confirmed on a new lumbar spine simulator in vitro. Arch Orthop Trauma Surg 199:127–132CrossRef
9.
go back to reference Schmoelz W, Huber JF, Nydegger T, Dipl-Ing, Claes L, Wilke HJ (2003) Dynamic stabilization of the lumbar spine and its effects on adjacent segments: an in vitro experiment. J Spinal Disord Tech 16:418–423PubMedCrossRef Schmoelz W, Huber JF, Nydegger T, Dipl-Ing, Claes L, Wilke HJ (2003) Dynamic stabilization of the lumbar spine and its effects on adjacent segments: an in vitro experiment. J Spinal Disord Tech 16:418–423PubMedCrossRef
10.
go back to reference Schmoelz W, Huber JF, Nydegger T, Claes L, Wilke HJ (2006) Influence of a dynamic stabilisation system on load bearing of a bridged disc: an in vitro study of intradiscal pressure. Eur Spine J 15:1276–1285PubMedCrossRef Schmoelz W, Huber JF, Nydegger T, Claes L, Wilke HJ (2006) Influence of a dynamic stabilisation system on load bearing of a bridged disc: an in vitro study of intradiscal pressure. Eur Spine J 15:1276–1285PubMedCrossRef
11.
go back to reference Rohlmann A, Burra NK, Zander T, Bergmann G (2007) Comparison of the effects of bilateral posterior dynamic and rigid fixation devices on the loads in the lumbar spine: a finite element analysis. Eur Spine J 16:1223–1231PubMedCrossRef Rohlmann A, Burra NK, Zander T, Bergmann G (2007) Comparison of the effects of bilateral posterior dynamic and rigid fixation devices on the loads in the lumbar spine: a finite element analysis. Eur Spine J 16:1223–1231PubMedCrossRef
12.
go back to reference Zander T, Rohlmann A, Burra NK, Bergmann G (2006) Effect of a posterior dynamic implant adjacent to a rigid spinal fixator. Clin Biomech 21:767–774CrossRef Zander T, Rohlmann A, Burra NK, Bergmann G (2006) Effect of a posterior dynamic implant adjacent to a rigid spinal fixator. Clin Biomech 21:767–774CrossRef
13.
go back to reference Niosi CA, Zhu QA, Wilson DC, Keynan O, Wilson DR, Oxland TR (2006) Biomechanical characterization of the three-dimensional kinematic behaviour of the Dynesys dynamic stabilization system: an in vitro study. Eur Spine J 15:913–922PubMedCrossRef Niosi CA, Zhu QA, Wilson DC, Keynan O, Wilson DR, Oxland TR (2006) Biomechanical characterization of the three-dimensional kinematic behaviour of the Dynesys dynamic stabilization system: an in vitro study. Eur Spine J 15:913–922PubMedCrossRef
14.
go back to reference Niosi CA, Wilson DC, Zhu Q, Keynan O, Wilson DR, Oxland TR (2008) The effect of Dynamic posterior stabilization on facet joint contact forces. Spine 33:19–26PubMedCrossRef Niosi CA, Wilson DC, Zhu Q, Keynan O, Wilson DR, Oxland TR (2008) The effect of Dynamic posterior stabilization on facet joint contact forces. Spine 33:19–26PubMedCrossRef
15.
go back to reference Liu CL, Zhong ZC, Shih SL, Hung C, Lee YE, Chen CS (2010) Influence of Dynesys system screw profile on adjacent segment and screw. J Spinal Disord Tech 23:410–417PubMedCrossRef Liu CL, Zhong ZC, Shih SL, Hung C, Lee YE, Chen CS (2010) Influence of Dynesys system screw profile on adjacent segment and screw. J Spinal Disord Tech 23:410–417PubMedCrossRef
16.
go back to reference Shirazi-Adl A, Ahmed AM, Shrivastava SC (1986) Mechanical response of a lumbar motion segment in axial torque alone and combined with compression. Spine 11:914–927PubMedCrossRef Shirazi-Adl A, Ahmed AM, Shrivastava SC (1986) Mechanical response of a lumbar motion segment in axial torque alone and combined with compression. Spine 11:914–927PubMedCrossRef
17.
go back to reference Panagiotacopulos ND, Pope MH, Krag MH, Block R (1987) Water content in human intervertebral discs. Part I. Measurement by magnetic resonance imaging. Spine 12:912–917PubMedCrossRef Panagiotacopulos ND, Pope MH, Krag MH, Block R (1987) Water content in human intervertebral discs. Part I. Measurement by magnetic resonance imaging. Spine 12:912–917PubMedCrossRef
18.
go back to reference Zhong ZC, Chen SH, Hung C (2009) Load- and displacement-controlled finite element analyses on fusion and non-fusion spinal implants. Proc Inst Mech Eng H 223:143–157PubMedCrossRef Zhong ZC, Chen SH, Hung C (2009) Load- and displacement-controlled finite element analyses on fusion and non-fusion spinal implants. Proc Inst Mech Eng H 223:143–157PubMedCrossRef
19.
go back to reference Chen SH, Zhong ZC, Chen CS, Chen WJ, Hung C (2009) Biomechanical comparison between lumbar disc arthroplasty and fusion. Med Eng Phys 31:244–253PubMedCrossRef Chen SH, Zhong ZC, Chen CS, Chen WJ, Hung C (2009) Biomechanical comparison between lumbar disc arthroplasty and fusion. Med Eng Phys 31:244–253PubMedCrossRef
20.
go back to reference Goel VK, Grauer JN, Patel TCh et al (2005) Effects of charité artificial disc on the implanted and adjacent spinal segments mechanics using a hybrid testing protocol. Spine 30:2755–2764PubMedCrossRef Goel VK, Grauer JN, Patel TCh et al (2005) Effects of charité artificial disc on the implanted and adjacent spinal segments mechanics using a hybrid testing protocol. Spine 30:2755–2764PubMedCrossRef
21.
go back to reference Cheng BC, Gordon J, Cheng J, Welch WC (2007) Immediate biomechanical effects of lumbar posterior dynamic stabilization above a circumferential fusion. Spine 32:2551–2557PubMedCrossRef Cheng BC, Gordon J, Cheng J, Welch WC (2007) Immediate biomechanical effects of lumbar posterior dynamic stabilization above a circumferential fusion. Spine 32:2551–2557PubMedCrossRef
22.
go back to reference Rohlmann A, Zander T, Rao M, Bergmann G (2009) Applying a follower load delivers realistic results for simulating standing. J Biomech 42:1520–1526PubMedCrossRef Rohlmann A, Zander T, Rao M, Bergmann G (2009) Applying a follower load delivers realistic results for simulating standing. J Biomech 42:1520–1526PubMedCrossRef
Metadata
Title
Effect of the cord pretension of the Dynesys dynamic stabilisation system on the biomechanics of the lumbar spine: a finite element analysis
Authors
Chien-Lin Liu
Zheng-Cheng Zhong
Hung-Wei Hsu
Shih-Liang Shih
Shih-Tien Wang
Chinghua Hung
Chen-Sheng Chen
Publication date
01-11-2011
Publisher
Springer-Verlag
Published in
European Spine Journal / Issue 11/2011
Print ISSN: 0940-6719
Electronic ISSN: 1432-0932
DOI
https://doi.org/10.1007/s00586-011-1817-3

Other articles of this Issue 11/2011

European Spine Journal 11/2011 Go to the issue