Published in: Surgical Endoscopy 10/2003

01-10-2003 | Original article

Real-time thermography during energized vessel sealing and dissection

Authors: P. A. Campbell, A. B. Cresswell, T. G. Frank, A. Cuschieri

Published in: Surgical Endoscopy | Issue 10/2003

Login to get access

Abstract

Background: Energized dissection systems facilitate laparoscopic dissection and hemostasis and reduce instrument traffic. However, they can introduce undesirable thermal collateral/proximity damage to adjacent structures mainly by heat conduction, although other mechanisms may be involved. The latest generation devices have the potential to reduce the incidence of such problems through use of active feedback control over the power output. This effectively regulates the delivery of energy to the target tissue with minimal thermal collateral damage. In addition, innovative heat-sink engineering of the device head ensures that the surface of the instrument tip remains cool (<45°C). In this study, we evaluated the performance of this technology (LigaSure) by using dynamic infrared thermography. The thermal imaging measurements were then correlated with histopathologic studies. The overall value of in situ thermography as an adjunct to energized surgical dissection systems was also assessed. Methods: Eight anesthetized pigs underwent open surgery to mobilize eight target vessels/organs in a randomized fashion. The LigaSure vessel sealing system with Instant Response Technology was used with three different interchangeable heads. In situ dynamic thermography was undertaken with a thermal imaging camera operating in the mid-infrared (3–5 µm) waveband and with each fully digitized 12-bit thermographic frame acquired at a rate of 60 Hz. Following sacrifice at the end of the dissection, tissue from the dissected regions was harvested for histology by an independent pathologist who was blinded to the thermographic data. Results: Seals made with both the LS1000 5-mm laparoscopic head (predominantly to the small bowel and colon) and the LS1100 10-mm (Atlas) device (on the liver and short gastric tissues) were outwardly satisfactory. The average thermal spread ( https://static-content.springer.com/image/art%3A10.1007%2Fs00464-002-8781-2/MediaObjects/ueq1.gif ) with the LS1000 was https://static-content.springer.com/image/art%3A10.1007%2Fs00464-002-8781-2/MediaObjects/ueq1.gif = 4.4 mm, and the exposed surface of the instrument tip developed a temperature of approximately 100°C. This instrument thus has the potential, albeit small, for heat-related proximity iatrogenic injury. The more technologically advanced LS1100 10-mm laparoscopic instrument exhibited a superior performance, with https://static-content.springer.com/image/art%3A10.1007%2Fs00464-002-8781-2/MediaObjects/ueq1.gif = 1.8 mm, and with a maximal temperature on the exposed surface of the jaws well within tolerable limits (approximately 35°C) for use during surgery (laparoscopic or open). This was confirmed by histological studies that demonstrated negligible evidence of thermal damage. Conclusions: In situ thermal imaging represents a powerful modality for the monitoring of energized dissection/coagulation during surgery. The LigaSure system used with the LS1100 head constitutes a very safe option for energized dissection and hemostasis of vessels with a diameter of up to approximately 7 mm.
Literature
1.
go back to reference Heniford, BT, Matthews, BD, Sing, RF, Backus, C, Pratt, P, Greene, FL 2001Initial results with an electrothermal bipolar vessel sealer.Surg Endosc15799801 Heniford, BT, Matthews, BD, Sing, RF, Backus, C, Pratt, P, Greene, FL 2001Initial results with an electrothermal bipolar vessel sealer.Surg Endosc15799801
2.
go back to reference Kennedy, JS, Stranahan, PL, Taylor, KD, Chandler, JG 1998High burst strength, feed-back controlled bipolar vessel sealing.Surg Endosc12876878 Kennedy, JS, Stranahan, PL, Taylor, KD, Chandler, JG 1998High burst strength, feed-back controlled bipolar vessel sealing.Surg Endosc12876878
3.
go back to reference Kinoshita, T, Kanehira, E, Omura, K, Kawakami, K, Watanabe, Y 1999Experimental study on heat production by a 23.5 kHz ultrasonically activated device for endoscopic surgery.Surg Endosc13621625 Kinoshita, T, Kanehira, E, Omura, K, Kawakami, K, Watanabe, Y 1999Experimental study on heat production by a 23.5 kHz ultrasonically activated device for endoscopic surgery.Surg Endosc13621625
4.
go back to reference Klioze, SD, Poppaas, DP, Rooke, CT, Choma, TJ, Schlossberg, SM 1994Development and initial application of a real time thermal control system for laser tissue welding.J Urol152744748PubMed Klioze, SD, Poppaas, DP, Rooke, CT, Choma, TJ, Schlossberg, SM 1994Development and initial application of a real time thermal control system for laser tissue welding.J Urol152744748PubMed
5.
go back to reference .1999Ligasure vessel sealing system service manual.ValleyLab, Boulder, CoUSA410 .1999Ligasure vessel sealing system service manual.ValleyLab, Boulder, CoUSA410
6.
go back to reference Palazzo, FF, Francis, DL, Clifton, MA 2002Randomised clinical trial of Ligasure versus open haemorrhoidectomy.Br J Surg89154157PubMed Palazzo, FF, Francis, DL, Clifton, MA 2002Randomised clinical trial of Ligasure versus open haemorrhoidectomy.Br J Surg89154157PubMed
7.
go back to reference Reidenbach, HD, Buess, G 1992Anciliary technology: electrocautery, thermoregulation and laser.Cuschieri, ABuess, GPerrisat, L eds. Operative manual of endoscopic surgery.SpringerBerlin4460 Reidenbach, HD, Buess, G 1992Anciliary technology: electrocautery, thermoregulation and laser.Cuschieri, ABuess, GPerrisat, L eds. Operative manual of endoscopic surgery.SpringerBerlin4460
8.
go back to reference Schulze, S, Krisitiansen, VB, Fischer-Hansen, B, Rosenberg, J 2002Sealing of the cystic duct with bipolar electrocoagulation.Surg Endosc16342344PubMed Schulze, S, Krisitiansen, VB, Fischer-Hansen, B, Rosenberg, J 2002Sealing of the cystic duct with bipolar electrocoagulation.Surg Endosc16342344PubMed
9.
go back to reference Sengupta, S, Webb, DR 2001Use of a computer controlled bipolar diathermy system in radical prostatectomies and other open urological surgery.A N Z J Surg71538540CrossRef Sengupta, S, Webb, DR 2001Use of a computer controlled bipolar diathermy system in radical prostatectomies and other open urological surgery.A N Z J Surg71538540CrossRef
10.
go back to reference Sigel, B, Dunn, MR 1965The mechanism of blood vessel closure by high frequency electocoagulation.Surg Gynecol Obstet121823831PubMed Sigel, B, Dunn, MR 1965The mechanism of blood vessel closure by high frequency electocoagulation.Surg Gynecol Obstet121823831PubMed
11.
go back to reference Spivak, H, Richardson, WS, Hunter, JG 1998The use of bipolar cautery, laparoscopic coagulating shears, and vascular clips for hemostasis of small and medium sized vessels.Surg Endosc12183185CrossRefPubMed Spivak, H, Richardson, WS, Hunter, JG 1998The use of bipolar cautery, laparoscopic coagulating shears, and vascular clips for hemostasis of small and medium sized vessels.Surg Endosc12183185CrossRefPubMed
12.
go back to reference Thomsen, S, Pearce, JA, Cheong, WF 1989Changes in birefringence as markers of thermal damage in tissues.IEEE Trans Biomed Eng3611741179CrossRefPubMed Thomsen, S, Pearce, JA, Cheong, WF 1989Changes in birefringence as markers of thermal damage in tissues.IEEE Trans Biomed Eng3611741179CrossRefPubMed
Metadata
Title
Real-time thermography during energized vessel sealing and dissection
Authors
P. A. Campbell
A. B. Cresswell
T. G. Frank
A. Cuschieri
Publication date
01-10-2003
Publisher
Springer-Verlag
Published in
Surgical Endoscopy / Issue 10/2003
Print ISSN: 0930-2794
Electronic ISSN: 1432-2218
DOI
https://doi.org/10.1007/s00464-002-8781-2

Other articles of this Issue 10/2003

Surgical Endoscopy 10/2003 Go to the issue