Skip to main content
Top
Published in: Langenbeck's Archives of Surgery 4/2007

01-07-2007 | Original Article

Incisional hernia: challenge of re-operations after mesh repair

Authors: Joachim Conze, Carsten J. Krones, Volker Schumpelick, Uwe Klinge

Published in: Langenbeck's Archives of Surgery | Issue 4/2007

Login to get access

Abstract

Background and aims

The widespread use of meshes for the repair of incisional hernia is currently followed by an increasing number of re-operations. The incidence of incisional hernia recurrence after mesh repair varies between 3 and 32%. The problem of mesh failure and options for another surgical intervention seem rather unattended.

Methods

We present our experience of 77 re-operations after previous mesh repair that were performed between 1995 and 2004 out of a total of 1,070 operations for incisional hernia. The retrospective analysis focused on recurrence in relation to location, material of the previous mesh repair and the surgical procedure to resolve the problem.

Results

The locations of the preceding meshes were epifascial as onlays (n=23), retromuscular as sublays (n=46), within the defect as inlays (n=6) or intraperitoneally (n=2). The direction of the incision was vertical medial (n=41) or horizontal crossing the linea semilunaris (n=36). Recurrences after median incisional hernia mesh repair mainly occurred at the cranial border of the mesh subxiphoidal. Except for two patients, all recurrences manifested at the margin of the enclosed mesh.

Conclusions

Re-operation after previous mesh repair is a surgical challenge. The type of revision procedure has to consider the position and material of the previous mesh. In our clinic recurrences, heavyweight polypropylene meshes were mostly treated with mesh exchange and lightweight polypropylene meshes could be treated by extension with a second mesh. In contrast to suture techniques, deficient mesh repairs are more evidently related to technical problems.
Literature
1.
go back to reference Hoer J, Lawong G, Klinge U, Schumpelick V (2002) Factors influencing the development of incisional hernia. A retrospective study of 2,983 laparotomy patients over a period of 10 years. Chirurg 73(5):474–480PubMedCrossRef Hoer J, Lawong G, Klinge U, Schumpelick V (2002) Factors influencing the development of incisional hernia. A retrospective study of 2,983 laparotomy patients over a period of 10 years. Chirurg 73(5):474–480PubMedCrossRef
2.
go back to reference Schumpelick V, Conze J, Klinge U (1996) Preperitoneal mesh-plasty in incisional hernia repair. A comparative retrospective study of 272 operated incisional hernias. Chirurg 67(10):1028–1035PubMedCrossRef Schumpelick V, Conze J, Klinge U (1996) Preperitoneal mesh-plasty in incisional hernia repair. A comparative retrospective study of 272 operated incisional hernias. Chirurg 67(10):1028–1035PubMedCrossRef
3.
go back to reference Schumpelick V, Klinge U, Junge K, Stumpf M (2004) Incisional abdominal hernia: the open mesh repair. Langenbecks Arch Surg 389(1):1–5PubMedCrossRef Schumpelick V, Klinge U, Junge K, Stumpf M (2004) Incisional abdominal hernia: the open mesh repair. Langenbecks Arch Surg 389(1):1–5PubMedCrossRef
4.
go back to reference Flum DR, Horvath K, Koepsell T (2003) Have outcomes of incisional hernia repair improved with time? A population-based analysis. Ann Surg 237(1):129–135PubMedCrossRef Flum DR, Horvath K, Koepsell T (2003) Have outcomes of incisional hernia repair improved with time? A population-based analysis. Ann Surg 237(1):129–135PubMedCrossRef
5.
go back to reference Jansen PL, Mertens PR, Klinge U, Schumpelick V (2004) The biology of hernia formation. Surgery 136(1):1–4PubMedCrossRef Jansen PL, Mertens PR, Klinge U, Schumpelick V (2004) The biology of hernia formation. Surgery 136(1):1–4PubMedCrossRef
6.
go back to reference Burger JW, Luijendijk RW, Hop WC, Halm JA, Verdaasdonk EG, Jeekel J (2004) Long-term follow-up of a randomized controlled trial of suture versus mesh repair of incisional hernia. Ann Surg 240(4):578–583 (discussion 583–585)PubMed Burger JW, Luijendijk RW, Hop WC, Halm JA, Verdaasdonk EG, Jeekel J (2004) Long-term follow-up of a randomized controlled trial of suture versus mesh repair of incisional hernia. Ann Surg 240(4):578–583 (discussion 583–585)PubMed
7.
go back to reference Langer C, Neufang T, Kley C, Liersch T, Becker H (2001) Central mesh recurrence after incisional hernia repair with Marlex—are the meshes strong enough? Hernia 5(3):164–167PubMedCrossRef Langer C, Neufang T, Kley C, Liersch T, Becker H (2001) Central mesh recurrence after incisional hernia repair with Marlex—are the meshes strong enough? Hernia 5(3):164–167PubMedCrossRef
8.
go back to reference Schumpelick V, Nyhus L (2003) Meshes: benefits and risks. Springer, Berlin Heidelberg New York Schumpelick V, Nyhus L (2003) Meshes: benefits and risks. Springer, Berlin Heidelberg New York
9.
go back to reference Junge K, Klinge U, Rosch R, Mertens PR, Kirch J, Klosterhalfen B et al (2004) Decreased collagen type I/III ratio in patients with recurring hernia after implantation of alloplastic prostheses. Langenbecks Arch Surg 389(1):17–22PubMedCrossRef Junge K, Klinge U, Rosch R, Mertens PR, Kirch J, Klosterhalfen B et al (2004) Decreased collagen type I/III ratio in patients with recurring hernia after implantation of alloplastic prostheses. Langenbecks Arch Surg 389(1):17–22PubMedCrossRef
10.
go back to reference Conze J, Prescher A, Klinge U, Saklak M, Schumpelick V (2004) Pitfalls in retromuscular mesh repair for incisional hernia: the importance of the “fatty triangle”. Hernia 8(3):255–259PubMedCrossRef Conze J, Prescher A, Klinge U, Saklak M, Schumpelick V (2004) Pitfalls in retromuscular mesh repair for incisional hernia: the importance of the “fatty triangle”. Hernia 8(3):255–259PubMedCrossRef
11.
go back to reference Conze J, Prescher A, Kisielinski K, Klinge U, Schumpelick V (2005) Technical consideration for subxiphoidal incisional hernia repair. Hernia 9(1):84–87PubMedCrossRef Conze J, Prescher A, Kisielinski K, Klinge U, Schumpelick V (2005) Technical consideration for subxiphoidal incisional hernia repair. Hernia 9(1):84–87PubMedCrossRef
12.
go back to reference Klosterhalfen B, Junge K, Hermanns B, Klinge U (2002) Influence of implantation interval on the long-term biocompatibility of surgical mesh. Br J Surg 89(8):1043–1048PubMedCrossRef Klosterhalfen B, Junge K, Hermanns B, Klinge U (2002) Influence of implantation interval on the long-term biocompatibility of surgical mesh. Br J Surg 89(8):1043–1048PubMedCrossRef
13.
go back to reference Klosterhalfen B, Klinge U, Hermanns B, Schumpelick V (2000) Pathology of traditional surgical nets for hernia repair after long-term implantation in humans. Chirurg 71(1):43–51PubMed Klosterhalfen B, Klinge U, Hermanns B, Schumpelick V (2000) Pathology of traditional surgical nets for hernia repair after long-term implantation in humans. Chirurg 71(1):43–51PubMed
14.
go back to reference Klosterhalfen B, Klinge U, Schumpelick V (1998) Functional and morphological evaluation of different polypropylene-mesh modifications for abdominal wall repair. Biomaterials 19:2235–2246PubMedCrossRef Klosterhalfen B, Klinge U, Schumpelick V (1998) Functional and morphological evaluation of different polypropylene-mesh modifications for abdominal wall repair. Biomaterials 19:2235–2246PubMedCrossRef
15.
go back to reference LeBlanc KA, Whitaker JM (2002) Management of chronic postoperative pain following incisional hernia repair with Composix mesh: a report of two cases. Hernia 6(4):194–197PubMedCrossRef LeBlanc KA, Whitaker JM (2002) Management of chronic postoperative pain following incisional hernia repair with Composix mesh: a report of two cases. Hernia 6(4):194–197PubMedCrossRef
Metadata
Title
Incisional hernia: challenge of re-operations after mesh repair
Authors
Joachim Conze
Carsten J. Krones
Volker Schumpelick
Uwe Klinge
Publication date
01-07-2007
Publisher
Springer-Verlag
Published in
Langenbeck's Archives of Surgery / Issue 4/2007
Print ISSN: 1435-2443
Electronic ISSN: 1435-2451
DOI
https://doi.org/10.1007/s00423-006-0065-1

Other articles of this Issue 4/2007

Langenbeck's Archives of Surgery 4/2007 Go to the issue

Current Concepts in Endocrine Surgery

The eligibility of MIVA approach in thyroid surgery