Skip to main content
Top
Published in: Langenbeck's Archives of Surgery 1/2004

01-02-2004 | Current Concepts in Clinical Surgery

Incisional abdominal hernia: the open mesh repair

Authors: V. Schumpelick, U. Klinge, K. Junge, M. Stumpf

Published in: Langenbeck's Archives of Surgery | Issue 1/2004

Login to get access

Abstract

Background

Mesh techniques are the methods of choice for the repair of incisional hernias since these are due to the formation of unstable scar tissue.

Methods

We review the materials and techniques used in the repair of incisional hernias. We describe in detail the operative technique performed in our clinic, the pitfalls of the repair, and the overlap behind the xiphoid and the pubic bone.

Results

Polypropylene is the material widely used for open mesh repair. New developments have led to low-weight, large-pore polypropylene prostheses, which are adjusted to the physiological requirements of the abdominal wall and permit a proper tissue integration. These meshes provide the possibility of forming a scar net instead of a stiff scar plate and therefore help to avoid former known mesh complications.

Conclusions

The ideal position for the mesh is the retromuscular sublay position where the force of the abdominal pressure holds the prosthesis against the deep surface of the muscles. The lowest incidence rates of recurrence have been reported for the retromuscular sublay repair; even after long-term follow-up recurrence rates of 10% are possible. Attaining such good results requires an adequate size of the mesh with sufficient overlap of at least 5–6 cm in all directions. Open mesh repair using modern low-weight polypropylene meshes in the retromuscular sublay technique offers excellent results for the treatment of incisional hernias.
Literature
1.
go back to reference Chevrel J, Rath A (1999) Polyester mesh for incision hernia repair. In: Schumpelick V, Kingsnorth A (eds) Incision hernia. Springer, Berlin Heidelberg New York, pp 327–333 Chevrel J, Rath A (1999) Polyester mesh for incision hernia repair. In: Schumpelick V, Kingsnorth A (eds) Incision hernia. Springer, Berlin Heidelberg New York, pp 327–333
2.
go back to reference Klinge U, Si ZY, Zheng H, Schumpelick V, Bhardwaj R, Klosterhalfen B (2001) Collagen I/III and matrix metalloproteinases (MMP) 1 and 13 in the fascia of patients with incisional hernias. J Invest Surg 14:47–54CrossRefPubMed Klinge U, Si ZY, Zheng H, Schumpelick V, Bhardwaj R, Klosterhalfen B (2001) Collagen I/III and matrix metalloproteinases (MMP) 1 and 13 in the fascia of patients with incisional hernias. J Invest Surg 14:47–54CrossRefPubMed
3.
go back to reference Klinge U, Klosterhalfen B, Birkenauer V, Junge K, Conze J, Schumpelick V (2002) Impact of polymer pore size on the interface scar formation in a rat model. J Surg Res 103:208–214CrossRefPubMed Klinge U, Klosterhalfen B, Birkenauer V, Junge K, Conze J, Schumpelick V (2002) Impact of polymer pore size on the interface scar formation in a rat model. J Surg Res 103:208–214CrossRefPubMed
4.
go back to reference Klinge U, Junge K, Stumpf M, Oettinger AP, Klosterhalfen B (2002) Functional and morphologic evaluation of a low-weight, monofilament polypropylene mesh for hernia repair. J Biomed Mater Res 63:129–136CrossRefPubMed Klinge U, Junge K, Stumpf M, Oettinger AP, Klosterhalfen B (2002) Functional and morphologic evaluation of a low-weight, monofilament polypropylene mesh for hernia repair. J Biomed Mater Res 63:129–136CrossRefPubMed
5.
go back to reference Klosterhalfen B, Klinge U, Schumpelick V (1998) Functional and morphologic evaluation of different polypropylene mesh modifications for abdominal wall repair. Biomaterials 19:2235–2246CrossRefPubMed Klosterhalfen B, Klinge U, Schumpelick V (1998) Functional and morphologic evaluation of different polypropylene mesh modifications for abdominal wall repair. Biomaterials 19:2235–2246CrossRefPubMed
6.
go back to reference Ladurner R, Trupka A, Schmidbauer S, Hallfeldt K (2001) The use of a underlay polypropylene mesh in complicated incisional hernias: successful French surgical technique. Minerva Chir 56:111–117PubMed Ladurner R, Trupka A, Schmidbauer S, Hallfeldt K (2001) The use of a underlay polypropylene mesh in complicated incisional hernias: successful French surgical technique. Minerva Chir 56:111–117PubMed
7.
go back to reference Langer I, Herzog U, Schuppisser JP, Ackermann C, Tondelli P (1996) Preperitoneal prosthesis implantation in surgical management of recurrent inguinal hernia. Retrospective evaluation of our results 1989–1994. Chirurg 67:394–402PubMed Langer I, Herzog U, Schuppisser JP, Ackermann C, Tondelli P (1996) Preperitoneal prosthesis implantation in surgical management of recurrent inguinal hernia. Retrospective evaluation of our results 1989–1994. Chirurg 67:394–402PubMed
8.
go back to reference Liakakos T, Karanikas I, Panagiotidis H, Dendrinos S (1994) Use of Marlex mesh in the repair of recurrent incision hernia. Br J Surg 81:248–249PubMed Liakakos T, Karanikas I, Panagiotidis H, Dendrinos S (1994) Use of Marlex mesh in the repair of recurrent incision hernia. Br J Surg 81:248–249PubMed
9.
go back to reference Luijendijk RW, Hop WC, van den Tol MP, de Lange DC, Braaksma MM, Ijzermans JN, et al (2000) A comparison of suture repair with mesh repair for incision hernia. N Engl J Med 343:392–398PubMed Luijendijk RW, Hop WC, van den Tol MP, de Lange DC, Braaksma MM, Ijzermans JN, et al (2000) A comparison of suture repair with mesh repair for incision hernia. N Engl J Med 343:392–398PubMed
10.
go back to reference Martin-Duce A, Noguerales F, Villeta R, Hernandez P, Lozano O, Keller J, et al (2001) Modifications to Rives technique for midline incision hernia repair. Hernia 5:70–72PubMed Martin-Duce A, Noguerales F, Villeta R, Hernandez P, Lozano O, Keller J, et al (2001) Modifications to Rives technique for midline incision hernia repair. Hernia 5:70–72PubMed
11.
go back to reference McLanahan D, King LT, Weems C, Novotney M, Gibson K (1997) Retrorectus prosthetic mesh repair of midline abdominal hernia. Am J Surg 173:445–449PubMed McLanahan D, King LT, Weems C, Novotney M, Gibson K (1997) Retrorectus prosthetic mesh repair of midline abdominal hernia. Am J Surg 173:445–449PubMed
12.
go back to reference Park A, Birch DW, Lovrics P (1998) Laparoscopic and open incisional hernia repair: a comparison study. Surgery 124:816–821PubMed Park A, Birch DW, Lovrics P (1998) Laparoscopic and open incisional hernia repair: a comparison study. Surgery 124:816–821PubMed
13.
go back to reference Schumpelick V, Conze J, Klinge U (1996) Preperitoneal mesh-plasty in incisional hernia repair. A comparative retrospective study of 272 operated incision hernias. Chirurg 67:1028–1035 Schumpelick V, Conze J, Klinge U (1996) Preperitoneal mesh-plasty in incisional hernia repair. A comparative retrospective study of 272 operated incision hernias. Chirurg 67:1028–1035
14.
go back to reference Schumpelick V, Klosterhalfen B, Müller M, Klinge U (1999) Minimized polypropylene mesh for preperitoneal net plasty of incisional hernia. Chirurg 70:422–430PubMed Schumpelick V, Klosterhalfen B, Müller M, Klinge U (1999) Minimized polypropylene mesh for preperitoneal net plasty of incisional hernia. Chirurg 70:422–430PubMed
15.
go back to reference Si Z, Bhardwaj R, Rosch R, Klosterhalfen B, Klinge U, Rhanjit B, Mertens PR (2002) Impaired balance of type I and type III procollagen mRNA in cultured fibroblasts of patients with incision hernia. Surgery 131:324–331CrossRefPubMed Si Z, Bhardwaj R, Rosch R, Klosterhalfen B, Klinge U, Rhanjit B, Mertens PR (2002) Impaired balance of type I and type III procollagen mRNA in cultured fibroblasts of patients with incision hernia. Surgery 131:324–331CrossRefPubMed
16.
go back to reference Sugerman HJ, Kellum JM, Reines HD, DeMaria EJ, Newsome HH, Lowry JW (1996) Greater risk of incision hernia with morbidly obese than steroid-dependent patients and low recurrence with prefascial polypropylene mesh. Am J Surg 171:80–84PubMed Sugerman HJ, Kellum JM, Reines HD, DeMaria EJ, Newsome HH, Lowry JW (1996) Greater risk of incision hernia with morbidly obese than steroid-dependent patients and low recurrence with prefascial polypropylene mesh. Am J Surg 171:80–84PubMed
17.
go back to reference Temudom T, Siadati M, Sarr MG (1996) Repair of complex giant or recurrent ventral hernias by using tension-free intraparietal prostetic mesh. Lessons learned from our initial experience. Surgery 120:738–743PubMed Temudom T, Siadati M, Sarr MG (1996) Repair of complex giant or recurrent ventral hernias by using tension-free intraparietal prostetic mesh. Lessons learned from our initial experience. Surgery 120:738–743PubMed
18.
go back to reference Toniato A, Pagetta C, Bernante P, Piotto A, Pelizzo MR (2002) Incisional hernia treatment with progressive pneumoperitoneum and retromuscular prosthetic hernioplasty. Langenbecks Arch Surg 387:246–148 Toniato A, Pagetta C, Bernante P, Piotto A, Pelizzo MR (2002) Incisional hernia treatment with progressive pneumoperitoneum and retromuscular prosthetic hernioplasty. Langenbecks Arch Surg 387:246–148
19.
go back to reference Usher F (1962) Hernia repair with Marlex mesh. Arch Surg 84:73–76 Usher F (1962) Hernia repair with Marlex mesh. Arch Surg 84:73–76
20.
go back to reference Welty G, Klinge U, Klosterhalfen B, Kasperk R, Schumpelick V (2001) Functional impairment and complaints following incisional hernia repair with different polypropylene meshes. Hernia 5:142–147PubMed Welty G, Klinge U, Klosterhalfen B, Kasperk R, Schumpelick V (2001) Functional impairment and complaints following incisional hernia repair with different polypropylene meshes. Hernia 5:142–147PubMed
Metadata
Title
Incisional abdominal hernia: the open mesh repair
Authors
V. Schumpelick
U. Klinge
K. Junge
M. Stumpf
Publication date
01-02-2004
Publisher
Springer-Verlag
Published in
Langenbeck's Archives of Surgery / Issue 1/2004
Print ISSN: 1435-2443
Electronic ISSN: 1435-2451
DOI
https://doi.org/10.1007/s00423-003-0352-z

Other articles of this Issue 1/2004

Langenbeck's Archives of Surgery 1/2004 Go to the issue