Skip to main content
Top
Published in: Graefe's Archive for Clinical and Experimental Ophthalmology 12/2017

01-12-2017 | Retinal Disorders

Large semicircular inverted internal limiting membrane flap in the treatment of macular hole in high myopia

Author: San-Ni Chen

Published in: Graefe's Archive for Clinical and Experimental Ophthalmology | Issue 12/2017

Login to get access

Abstract

Purpose

To describe the technique and surgical outcomes of a modified large semicircular inverted internal limiting membrane (ILM) flap in the management of macular holes (MHs) in patients with high myopia.

Methods

We performed this retrospective study on consecutive patients with MH and high myopia (axial length ≥ 28 mm),who received vitrectomy, a large semicircular ILM flap 4 discs in diameter to cover the MH, incomplete air–fluid exchange, and SF6 gas tamponade. All of the patients maintained an upright position for 2 h postoperatively, followed by either a face-down or upright position for 1 week. Post-operative visual acuity was measured, and MH status was assessed using spectral-domain optical coherence tomography.

Results

Seventeen highly myopic eyes in 16 patients with a mean axial length of 30.49 ± 0.98 mm and mean age of 62.25 ± 9.40 years were included in this study, including five eyes with foveoschisis and four eyes with chronic MH, two with myopic choroidal neovascularization, and four with MH-associated retinal detachment. The MHs of all patients were successfully closed after a single operation. All of the patients were followed for at least 6 months. The average visual acuity in logarithm of minimal angle of resolution improved from 1.26 ± 0.52 preoperatively to 0.69 ± 0.45 6 months postoperatively (p = 0.01, paired t-test).

Conclusion

A large semicircular inverted ILM flap can close a myopic MH efficiently without the need for a long-term face-down position.
Appendix
Available only for authorised users
Literature
1.
go back to reference Ichibe M, Yoshizawa T, Murakami K, Ohta M, Oya Y et al (2003) Surgical management of retinal detachment associated with myopic macular hole: anatomic and functional status of the macula. Am J Ophthalmol 136:277–284CrossRefPubMed Ichibe M, Yoshizawa T, Murakami K, Ohta M, Oya Y et al (2003) Surgical management of retinal detachment associated with myopic macular hole: anatomic and functional status of the macula. Am J Ophthalmol 136:277–284CrossRefPubMed
2.
go back to reference Ikuno Y, Tano Y (2006) Vitrectomy for macular holes associated with myopic foveoschisis. Am J Ophthalmol 141:774–776CrossRefPubMed Ikuno Y, Tano Y (2006) Vitrectomy for macular holes associated with myopic foveoschisis. Am J Ophthalmol 141:774–776CrossRefPubMed
3.
go back to reference Jo Y, Ikuno Y, Nishida K (2012) Retinoschisis: a predictive factor in vitrectomy for macular holes without retinal detachment in highly myopic eyes. Br J Ophthalmol 96:197–200CrossRefPubMed Jo Y, Ikuno Y, Nishida K (2012) Retinoschisis: a predictive factor in vitrectomy for macular holes without retinal detachment in highly myopic eyes. Br J Ophthalmol 96:197–200CrossRefPubMed
4.
go back to reference Wu TT, Kung YH (2012) Comparison of anatomical and visual outcomes of macular hole surgery in patients with high myopia vs non-high myopia: a case–control study using optical coherence tomography. Graefes Arch Clin Exp Ophthalmol 250:327–331CrossRefPubMed Wu TT, Kung YH (2012) Comparison of anatomical and visual outcomes of macular hole surgery in patients with high myopia vs non-high myopia: a case–control study using optical coherence tomography. Graefes Arch Clin Exp Ophthalmol 250:327–331CrossRefPubMed
5.
go back to reference Suda K, Hangai M, Yoshimura N (2011) Axial length and outcomes of macular hole surgery assessed by spectral-domain optical coherence tomography. Am J Ophthalmol 151:118–127CrossRefPubMed Suda K, Hangai M, Yoshimura N (2011) Axial length and outcomes of macular hole surgery assessed by spectral-domain optical coherence tomography. Am J Ophthalmol 151:118–127CrossRefPubMed
6.
go back to reference Sulkes DJ, Smiddy WE, Flynn HW, Feuer W (2000) Outcomes of macular hole surgery in severely myopic eyes: a case–control study. Am J Ophthalmol 130:335–339CrossRefPubMed Sulkes DJ, Smiddy WE, Flynn HW, Feuer W (2000) Outcomes of macular hole surgery in severely myopic eyes: a case–control study. Am J Ophthalmol 130:335–339CrossRefPubMed
7.
go back to reference Patel SC, Loo RH, Thompson JT, Sjaarda RN (2001) Macular hole surgery in high myopia. Ophthalmology 108:377–380CrossRefPubMed Patel SC, Loo RH, Thompson JT, Sjaarda RN (2001) Macular hole surgery in high myopia. Ophthalmology 108:377–380CrossRefPubMed
8.
go back to reference Alkabes M, Padilla L, Salinas C, Nucci P, Vitale L et al (2013) Assessment of OCT measurements as prognostic factors in myopic macular hole surgery without foveoschisis. Graefes Arch Clin Exp Ophthalmol 251:2521–2527CrossRefPubMed Alkabes M, Padilla L, Salinas C, Nucci P, Vitale L et al (2013) Assessment of OCT measurements as prognostic factors in myopic macular hole surgery without foveoschisis. Graefes Arch Clin Exp Ophthalmol 251:2521–2527CrossRefPubMed
9.
go back to reference Michalewska Z, Michalewska J, Adelman RA, Nawrocki J (2010) Inverted internal limiting membrane flap technique for large macular holes. Ophthalmology 117:2018–2025CrossRefPubMed Michalewska Z, Michalewska J, Adelman RA, Nawrocki J (2010) Inverted internal limiting membrane flap technique for large macular holes. Ophthalmology 117:2018–2025CrossRefPubMed
10.
go back to reference Kuriyama S, Hayashi H, Jingami Y, Kuramoto N, Akita J, Matsumoto M (2013) Efficacy of inverted internal limiting membrane flap technique for the treatment of macular hole in high myopia. Am J Ophthalmol 156:125–131CrossRefPubMed Kuriyama S, Hayashi H, Jingami Y, Kuramoto N, Akita J, Matsumoto M (2013) Efficacy of inverted internal limiting membrane flap technique for the treatment of macular hole in high myopia. Am J Ophthalmol 156:125–131CrossRefPubMed
11.
go back to reference Michalewska Z, Michalewski J, Dulczewska-Cichecka K, Nawrocki J (2014) Inverted internal limiting membrane flap technique in macular hole associated with pathological myopia. Retina 34:664–669CrossRefPubMed Michalewska Z, Michalewski J, Dulczewska-Cichecka K, Nawrocki J (2014) Inverted internal limiting membrane flap technique in macular hole associated with pathological myopia. Retina 34:664–669CrossRefPubMed
12.
go back to reference Shin MK, Park KH, Park SW, Byon IS, Lee JE (2014) Perfluoro-n-octane-assisted single-layered inverted internal limiting membrane flap technique for macular hole surgery. Retina 34:1905–1910CrossRefPubMed Shin MK, Park KH, Park SW, Byon IS, Lee JE (2014) Perfluoro-n-octane-assisted single-layered inverted internal limiting membrane flap technique for macular hole surgery. Retina 34:1905–1910CrossRefPubMed
13.
go back to reference Ho JD, Tsai RJ, Chen SN, Chen HC (2003) Cytotoxicity of indocyanine green on retinal pigment epithelium: implications for macular hole surgery. Arch Ophthalmol 121:1423–1429CrossRefPubMed Ho JD, Tsai RJ, Chen SN, Chen HC (2003) Cytotoxicity of indocyanine green on retinal pigment epithelium: implications for macular hole surgery. Arch Ophthalmol 121:1423–1429CrossRefPubMed
14.
go back to reference Chen SN, Yang CM (2016) Inverted internal limiting membrane insertion for macular hole-associated retinal detachment in high myopia. Am J Ophthalmol 162:99–106CrossRefPubMed Chen SN, Yang CM (2016) Inverted internal limiting membrane insertion for macular hole-associated retinal detachment in high myopia. Am J Ophthalmol 162:99–106CrossRefPubMed
15.
go back to reference Theodossiadis GP, Chatziralli IP, Theodossiadis PG (2016) Inverted internal limiting membrane insertion for macular hole-associated retinal detachment in high myopia. Am J Ophthalmol 165:206–207CrossRefPubMed Theodossiadis GP, Chatziralli IP, Theodossiadis PG (2016) Inverted internal limiting membrane insertion for macular hole-associated retinal detachment in high myopia. Am J Ophthalmol 165:206–207CrossRefPubMed
16.
go back to reference Michalewska Z, Michalewski J, Dulczewska-Cichecka K, Adelman RA, Nawrocki J (2015) Temporal inverted internal limiting membrane flap technique versus classic inverted internal limiting membrane flap technique: a comparative study. Retina 35:1844–1850CrossRefPubMed Michalewska Z, Michalewski J, Dulczewska-Cichecka K, Adelman RA, Nawrocki J (2015) Temporal inverted internal limiting membrane flap technique versus classic inverted internal limiting membrane flap technique: a comparative study. Retina 35:1844–1850CrossRefPubMed
17.
go back to reference Lai CC, Chen YP, Wang NK, Chuang LH, Liu L et al (2015) Vitrectomy with internal limiting membrane repositioning and autologous blood for macular hole retinal detachment in highly myopic eyes. Ophthalmology 122:1889–1898CrossRefPubMed Lai CC, Chen YP, Wang NK, Chuang LH, Liu L et al (2015) Vitrectomy with internal limiting membrane repositioning and autologous blood for macular hole retinal detachment in highly myopic eyes. Ophthalmology 122:1889–1898CrossRefPubMed
Metadata
Title
Large semicircular inverted internal limiting membrane flap in the treatment of macular hole in high myopia
Author
San-Ni Chen
Publication date
01-12-2017
Publisher
Springer Berlin Heidelberg
Published in
Graefe's Archive for Clinical and Experimental Ophthalmology / Issue 12/2017
Print ISSN: 0721-832X
Electronic ISSN: 1435-702X
DOI
https://doi.org/10.1007/s00417-017-3808-5

Other articles of this Issue 12/2017

Graefe's Archive for Clinical and Experimental Ophthalmology 12/2017 Go to the issue