Skip to main content
Top
Published in: International Journal of Legal Medicine 6/2019

Open Access 01-11-2019 | Computed Tomography | Original Article

Is CT bulletproof? On the use of CT for characterization of bullets in forensic radiology

Authors: L. E. Paulis, J. Kroll, L. Heijnens, M. Huijnen, R. Gerretsen, W. H. Backes, P. A. M. Hofman

Published in: International Journal of Legal Medicine | Issue 6/2019

Login to get access

Abstract

Purpose

Forensic investigations could benefit from non-invasive in situ characterization of bullets. Therefore, the use of CT imaging was explored for the analysis of bullet geometry and composition. Bullet visualization with CT is challenging as the metal constituents suffer from excessive X-ray attenuation due to their high atomic number, density, and geometry.

Methods

A metal reference phantom was developed containing small discs of various common metals (aluminum, iron, stainless steel, copper, brass, tungsten, and lead). CT images were acquired with 70–150 kVp and 200–400 mAs and were reconstructed using an extended Hounsfield unit (HU) scale (− 10,240 to + 30,710). For each material, the mean CT number (HU) was measured to construct a metal database. Different bullets (n = 11) were scanned in a soft tissue-mimicking phantom. Bullet size and shape were measured, and composition was evaluated by comparison with the metal database. Also, the effect of bullet orientation within the CT scanner was evaluated.

Results

In the reference phantom, metals were classified into three groups according to their atomic number (Z): low (Z ≤ 13; HU < 3000), medium (Z = 25–30; HU = 13,000–20,000), and high (Z ≥ 74; HU > 30,000). External bullet contours could be accurately delineated. Internal interfaces between jacket and core could not be identified. Cross-sectional spatial profile plots of the CT number along bullets’ short axis revealed beam hardening and photon starvation effects that depended on bullet size, shape, and orientation within the CT scanner. Therefore, the CT numbers of bullets were unreliable and could not be used for material characterization by comparison with the reference phantom.

Conclusion

CT-based characterization of bullets was feasible in terms of size and shape but not composition.
Literature
1.
go back to reference O’Donnell C, Woodford N (2008) Post-mortem radiology—a new sub-speciality? Clin Radiol 63:1189–1194CrossRef O’Donnell C, Woodford N (2008) Post-mortem radiology—a new sub-speciality? Clin Radiol 63:1189–1194CrossRef
2.
go back to reference Thali MJ, Yen K, Vock P, Ozdoba C, Kneubuehl BP, Sonnenschein M, Dirnhofer R (2003) Image-guided virtual autopsy findings of gunshot victims performed with multi-slice computed tomography and magnetic resonance imaging and subsequent correlation between radiology and autopsy findings. Forensic Sci Int 138:8–16CrossRef Thali MJ, Yen K, Vock P, Ozdoba C, Kneubuehl BP, Sonnenschein M, Dirnhofer R (2003) Image-guided virtual autopsy findings of gunshot victims performed with multi-slice computed tomography and magnetic resonance imaging and subsequent correlation between radiology and autopsy findings. Forensic Sci Int 138:8–16CrossRef
3.
go back to reference Van Kan RA, Haest II, Lahaye MJ et al (2017) The diagnostic value of forensic imaging in fatal gunshot incidents: a review of literature. JOFRI 10:9–14 Van Kan RA, Haest II, Lahaye MJ et al (2017) The diagnostic value of forensic imaging in fatal gunshot incidents: a review of literature. JOFRI 10:9–14
4.
go back to reference Oehmichen M, Gehl HB, Meissner C, Petersen D, Höche W, Gerling I, König HG (2003) Forensic pathological aspects of postmortem imaging of gunshot injury to the head: documentation and biometric data. Acta Neuropathol 105:570–580CrossRef Oehmichen M, Gehl HB, Meissner C, Petersen D, Höche W, Gerling I, König HG (2003) Forensic pathological aspects of postmortem imaging of gunshot injury to the head: documentation and biometric data. Acta Neuropathol 105:570–580CrossRef
5.
go back to reference Barret JF, Keat N (2004) Artifacts in CT: recognition and avoidance. Radiographics 24:1679–1691CrossRef Barret JF, Keat N (2004) Artifacts in CT: recognition and avoidance. Radiographics 24:1679–1691CrossRef
6.
go back to reference Bushberg JT, Seibert JA, Leidholdt EM et al (2012) The essential physics of medical imaging. Lippincott Williams & Wilkins, Philadelphia Bushberg JT, Seibert JA, Leidholdt EM et al (2012) The essential physics of medical imaging. Lippincott Williams & Wilkins, Philadelphia
7.
go back to reference Ruder TD, Thali Y, Bolliger SA, Somaini-Mathier S, Thali MJ, Hatch GM, Schindera ST (2013) Material differentiation in forensic radiology with single-source dual-energy computed tomography. Forensic Sci Med Pathol 9:163–169CrossRef Ruder TD, Thali Y, Bolliger SA, Somaini-Mathier S, Thali MJ, Hatch GM, Schindera ST (2013) Material differentiation in forensic radiology with single-source dual-energy computed tomography. Forensic Sci Med Pathol 9:163–169CrossRef
8.
go back to reference Ruder TD, Thali Y, Schindera ST, Torre SAD, Zech WD, Thali MJ, Ross S, Hatch GM (2012) How reliable are Hounsfield-unit measurements in forensic radiology? Forensic Sci Int 220:219–223CrossRef Ruder TD, Thali Y, Schindera ST, Torre SAD, Zech WD, Thali MJ, Ross S, Hatch GM (2012) How reliable are Hounsfield-unit measurements in forensic radiology? Forensic Sci Int 220:219–223CrossRef
9.
go back to reference Boas FE, Fleischmann D (2012) CT-artefacts: causes and reduction techniques. Imaging Med 4:229–240CrossRef Boas FE, Fleischmann D (2012) CT-artefacts: causes and reduction techniques. Imaging Med 4:229–240CrossRef
10.
go back to reference Kneubuehl BP, Coupland RM, Rothschild MA et al (2008) Wundballistik: Grundlagen und anwendungen. Springer Medizin Verlag, HeidelbergCrossRef Kneubuehl BP, Coupland RM, Rothschild MA et al (2008) Wundballistik: Grundlagen und anwendungen. Springer Medizin Verlag, HeidelbergCrossRef
11.
go back to reference Kumar J, Landheer D, Barnes-Warden J, Fenne P, Attridge A, Williams MA (2012) Inconsistency in 9 mm bullets measured with non-destructive X-ray computed tomography. Forensic Sci Int 214:48–58CrossRef Kumar J, Landheer D, Barnes-Warden J, Fenne P, Attridge A, Williams MA (2012) Inconsistency in 9 mm bullets measured with non-destructive X-ray computed tomography. Forensic Sci Int 214:48–58CrossRef
12.
go back to reference McGuire MF (2008) Stainless steels for design engineers. ASM International, NoveltyCrossRef McGuire MF (2008) Stainless steels for design engineers. ASM International, NoveltyCrossRef
13.
go back to reference Rosset Am Spadola L, Ratib O (2004) An open-source software for navigating in multidimensional DICOM images. J Digit Imaging 17:205–216CrossRef Rosset Am Spadola L, Ratib O (2004) An open-source software for navigating in multidimensional DICOM images. J Digit Imaging 17:205–216CrossRef
14.
go back to reference Schneider CA, Rasband WS, Eliceiri KW et al (2012) NIH image to ImageJ: 25 years of image analysis. Nat Methods 9:671–675CrossRef Schneider CA, Rasband WS, Eliceiri KW et al (2012) NIH image to ImageJ: 25 years of image analysis. Nat Methods 9:671–675CrossRef
16.
go back to reference Winklhofer S, Stolzmann P, Meier A, Schweitzer W, Morsbach F, Flach P, Kneubuehl BP, Alkadhi H, Thali M, Ruder T (2014) Added value of dual-energy computed tomography versus single energy computed tomography in assessing ferromagnetic properties of ballistic projectiles. Investig Radiol 49:431–437CrossRef Winklhofer S, Stolzmann P, Meier A, Schweitzer W, Morsbach F, Flach P, Kneubuehl BP, Alkadhi H, Thali M, Ruder T (2014) Added value of dual-energy computed tomography versus single energy computed tomography in assessing ferromagnetic properties of ballistic projectiles. Investig Radiol 49:431–437CrossRef
17.
go back to reference Thornby J, Landheer D, Williams T et al (2014) Inconsistency in 9mm bullets: correlation of jacket thickness to post-impact geometry measured with non-destructive X-ray computed tomography. For Sci Int 234:111–119 Thornby J, Landheer D, Williams T et al (2014) Inconsistency in 9mm bullets: correlation of jacket thickness to post-impact geometry measured with non-destructive X-ray computed tomography. For Sci Int 234:111–119
18.
go back to reference Luijten M, Haest II, van Kan RA et al (2016) Can post-mortem MRI be used to assess trajectories in gunshot victims? Int J Legal Med 130:457–462CrossRef Luijten M, Haest II, van Kan RA et al (2016) Can post-mortem MRI be used to assess trajectories in gunshot victims? Int J Legal Med 130:457–462CrossRef
Metadata
Title
Is CT bulletproof? On the use of CT for characterization of bullets in forensic radiology
Authors
L. E. Paulis
J. Kroll
L. Heijnens
M. Huijnen
R. Gerretsen
W. H. Backes
P. A. M. Hofman
Publication date
01-11-2019
Publisher
Springer Berlin Heidelberg
Published in
International Journal of Legal Medicine / Issue 6/2019
Print ISSN: 0937-9827
Electronic ISSN: 1437-1596
DOI
https://doi.org/10.1007/s00414-019-02033-0

Other articles of this Issue 6/2019

International Journal of Legal Medicine 6/2019 Go to the issue