Skip to main content
Top
Published in: Archives of Orthopaedic and Trauma Surgery 8/2019

01-08-2019 | Hip Arthroplasty

Acetabular revision arthroplasty using press-fitted jumbo cups: an average 10-year follow-up study

Authors: Jun-Ki Moon, Jaejoon Ryu, Yeesuk Kim, Jae-Hyuk Yang, Kyu-Tae Hwang, Young-Ho Kim

Published in: Archives of Orthopaedic and Trauma Surgery | Issue 8/2019

Login to get access

Abstract

Introduction

Acetabular revision arthroplasty using jumbo cups for moderate-to-severe acetabular defects has varied outcomes. We evaluated the clinical and radiological outcomes of acetabular revision arthroplasty using a press-fitted jumbo cup and sought to identify factors that influence outcomes during intermediate follow-up.

Materials and methods

Eighty patients (47 men, 33 women; 80 hips) who underwent acetabular revision arthroplasty using press-fitted jumbo cups were included. The mean follow-up period was 10.4 years. Harris hip score (HHS), presence of groin pain, radiographic results, and Kaplan–Meier survival curves were evaluated. Implant design and surgery-related and patient-related factors were assessed to identify influential factors for cup loosening. Migration and wear analyses were performed using Einzel-Bild-Röntgen-Analyse software.

Results

The mean preoperative HHS of 53 had improved to 77 at the final follow-up (p = 0.005). Nine patients experienced groin pain. Acetabular cup loosening was observed in seven cups (8.7%), and one jumbo cup was replaced with a reinforcement cage. The survival rate of the acetabular cup was 91% at 16 years according to the Kaplan–Meier analysis. Osteolysis was identified around the cup in six cases (7.5%). Acetabular cup loosening occurred more frequently in patients with conventional polyethylene liners than in those with highly cross-linked polyethylene liners (p = 0.045). The mean total migration was 1.52 mm, and the mean total wear was 0.98 mm. There was a positive correlation between total migration and total wear (p = 0.023; Spearman’s rho = 0.388). The mean wear rate of the patients with the cup inclination angle < 50° was significantly lower than those with the cup inclination angle > 50° (p = 0.001). There were four cases of complications (three dislocations and one infection) that did not require revision surgery.

Conclusion

Press-fitted jumbo cups for acetabular revision arthroplasty exhibited encouraging results during follow-up for an average of 10 years. Use of highly cross-linked polyethylene liners and proper placement of the acetabular component with an inclination angle < 50° may contribute to better clinical outcomes after acetabular revision arthroplasty with jumbo cups.
Literature
1.
go back to reference Della Valle CJ, Berger RA, Rosenberg AG, Galante JO (2004) Cementless acetabular reconstruction in revision total hip arthroplasty. Clin Orthop Relat Res 420:96–100CrossRef Della Valle CJ, Berger RA, Rosenberg AG, Galante JO (2004) Cementless acetabular reconstruction in revision total hip arthroplasty. Clin Orthop Relat Res 420:96–100CrossRef
2.
go back to reference Harris WH (2001) Porous hemispherical sockets: when round is right. Orthopedics 24:877–878PubMed Harris WH (2001) Porous hemispherical sockets: when round is right. Orthopedics 24:877–878PubMed
3.
go back to reference Konan S, Duncan CP, Masri BA, Garbuz DS (2016) Porous tantalum uncemented acetabular components in revision total hip arthroplasty: a minimum ten-year clinical, radiological and quality of life outcome study. Bone Jt J 98:767–771CrossRef Konan S, Duncan CP, Masri BA, Garbuz DS (2016) Porous tantalum uncemented acetabular components in revision total hip arthroplasty: a minimum ten-year clinical, radiological and quality of life outcome study. Bone Jt J 98:767–771CrossRef
4.
go back to reference Garbuz D, Morsi E, Gross AE (1996) Revision of the acetabular component of a total hip arthroplasty with a massive structural allograft. Study with a minimum five-year follow-up. J Bone Jt Surg Am 78:693–697CrossRef Garbuz D, Morsi E, Gross AE (1996) Revision of the acetabular component of a total hip arthroplasty with a massive structural allograft. Study with a minimum five-year follow-up. J Bone Jt Surg Am 78:693–697CrossRef
5.
go back to reference Chen HT, Wu CT, Huang TW, Shih HN, Wang JW, Lee MS (2018) Structural and morselized allografting combined with a cementless cup for acetabular defects in revision total hip arthroplasty: a 4- to 14-year follow-up. Biomed Res Int 2018:2364269PubMedPubMedCentral Chen HT, Wu CT, Huang TW, Shih HN, Wang JW, Lee MS (2018) Structural and morselized allografting combined with a cementless cup for acetabular defects in revision total hip arthroplasty: a 4- to 14-year follow-up. Biomed Res Int 2018:2364269PubMedPubMedCentral
6.
go back to reference Herrera A, Martínez AA, Cuenca J, Canales V (2006) Management of types III and IV acetabular deficiencies with the longitudinal oblong revision cup. J Arthroplasty 21:857–864CrossRefPubMed Herrera A, Martínez AA, Cuenca J, Canales V (2006) Management of types III and IV acetabular deficiencies with the longitudinal oblong revision cup. J Arthroplasty 21:857–864CrossRefPubMed
7.
go back to reference Surace MF, Zatti G, Pietri M, Cherubino P (2006) Acetabular revision surgery with the LOR cup: three to 8 years’ follow-up. J Arthroplasty 21:114–121CrossRefPubMed Surace MF, Zatti G, Pietri M, Cherubino P (2006) Acetabular revision surgery with the LOR cup: three to 8 years’ follow-up. J Arthroplasty 21:114–121CrossRefPubMed
8.
go back to reference Garcia-Rey E, Fernandez-Fernandez R, Duran D, Madero R (2013) Reconstruction of the rotation center of the hip after oblong cups in revision total hip arthroplasty. J Orthop Traumatol 14:39–49CrossRefPubMed Garcia-Rey E, Fernandez-Fernandez R, Duran D, Madero R (2013) Reconstruction of the rotation center of the hip after oblong cups in revision total hip arthroplasty. J Orthop Traumatol 14:39–49CrossRefPubMed
9.
go back to reference Regis D, Sandri A, Bonetti I, Bortolami O, Bartolozzi P (2012) A minimum of 10-year follow-up of the Burch-Schneider cage and bulk allografts for the revision of pelvic discontinuity. J Arthroplasty 27(1057–1063):e1 Regis D, Sandri A, Bonetti I, Bortolami O, Bartolozzi P (2012) A minimum of 10-year follow-up of the Burch-Schneider cage and bulk allografts for the revision of pelvic discontinuity. J Arthroplasty 27(1057–1063):e1
10.
go back to reference Abolghasemian M, Sadeghi Naini M, Tangsataporn S, Lee P, Backstein D, Safir O, Kuzyk P, Gross AE (2014) Reconstruction of massive uncontained acetabular defects using allograft with cage or ring reinforcement: an assessment of the graft's ability to restore bone stock and its impact on the outcome of re-revision. J Arthroplasty 96:319–324 Abolghasemian M, Sadeghi Naini M, Tangsataporn S, Lee P, Backstein D, Safir O, Kuzyk P, Gross AE (2014) Reconstruction of massive uncontained acetabular defects using allograft with cage or ring reinforcement: an assessment of the graft's ability to restore bone stock and its impact on the outcome of re-revision. J Arthroplasty 96:319–324
11.
go back to reference Ibrahim MS, Raja S, Haddad FS (2013) Acetabular impaction bone grafting in total hip replacement. Bone Jt J 95:98–102CrossRef Ibrahim MS, Raja S, Haddad FS (2013) Acetabular impaction bone grafting in total hip replacement. Bone Jt J 95:98–102CrossRef
12.
go back to reference Kostensalo I, Seppanen M, Virolainen P, Mokka J, Koivisto M, Makela KT (2015) Acetabular reconstruction with impaction bone grafting and cemented polyethylene socket in total hip revision arthroplasty. Scand J Surg 104:267–272CrossRefPubMed Kostensalo I, Seppanen M, Virolainen P, Mokka J, Koivisto M, Makela KT (2015) Acetabular reconstruction with impaction bone grafting and cemented polyethylene socket in total hip revision arthroplasty. Scand J Surg 104:267–272CrossRefPubMed
13.
go back to reference Borland WS, Bhattacharya R, Holland JP, Brewster NT (2012) Use of porous trabecular metal augments with impaction bone grafting in management of acetabular bone loss. Acta Orthop 83:347–352CrossRefPubMedPubMedCentral Borland WS, Bhattacharya R, Holland JP, Brewster NT (2012) Use of porous trabecular metal augments with impaction bone grafting in management of acetabular bone loss. Acta Orthop 83:347–352CrossRefPubMedPubMedCentral
14.
go back to reference Jenkins DR, Odland AN, Sierra RJ, Hanssen AD, Lewallen DG (2017) Minimum five-year outcomes with porous tantalum acetabular cup and augment construct in complex revision total hip arthroplasty. J Bone Jt Surg Am 99:e49CrossRef Jenkins DR, Odland AN, Sierra RJ, Hanssen AD, Lewallen DG (2017) Minimum five-year outcomes with porous tantalum acetabular cup and augment construct in complex revision total hip arthroplasty. J Bone Jt Surg Am 99:e49CrossRef
15.
go back to reference Abolghasemian M, Tangsataporn S, Sternheim A, Backstein DJ, Safir OA, Gross AE (2013) Porous metal augments: big hopes for big holes. Bone Jt J 95:103–108CrossRef Abolghasemian M, Tangsataporn S, Sternheim A, Backstein DJ, Safir OA, Gross AE (2013) Porous metal augments: big hopes for big holes. Bone Jt J 95:103–108CrossRef
16.
go back to reference Patel JV, Masonis JL, Bourne RB, Rorabeck CH (2003) The fate of cementless jumbo cups in revision hip arthroplasty. J Arthroplasty 18:129–133CrossRefPubMed Patel JV, Masonis JL, Bourne RB, Rorabeck CH (2003) The fate of cementless jumbo cups in revision hip arthroplasty. J Arthroplasty 18:129–133CrossRefPubMed
17.
go back to reference Wedemeyer C, Neuerburg C, Heep H, von Knoch F, von Knoch M, Löer F, Saxler G (2008) Jumbo cups for revision of acetabular defects after total hip arthroplasty: a retrospective review of a case series. Arch Orthop Trauma Surg 128:545–550CrossRefPubMed Wedemeyer C, Neuerburg C, Heep H, von Knoch F, von Knoch M, Löer F, Saxler G (2008) Jumbo cups for revision of acetabular defects after total hip arthroplasty: a retrospective review of a case series. Arch Orthop Trauma Surg 128:545–550CrossRefPubMed
18.
go back to reference Gustke KA, Levering MF, Miranda MA (2014) Use of jumbo cups for revision of acetabulae with large bony defects. J Arthroplasty 29:199–203CrossRefPubMed Gustke KA, Levering MF, Miranda MA (2014) Use of jumbo cups for revision of acetabulae with large bony defects. J Arthroplasty 29:199–203CrossRefPubMed
19.
go back to reference von Roth P, Abdel MP, Harmsen WS, Berry DJ (2015) Uncemented jumbo cups for revision total hip arthroplasty: a concise follow-up, at a mean of twenty years, of a previous report. J Bone Jt Surg Am 97:284–287CrossRef von Roth P, Abdel MP, Harmsen WS, Berry DJ (2015) Uncemented jumbo cups for revision total hip arthroplasty: a concise follow-up, at a mean of twenty years, of a previous report. J Bone Jt Surg Am 97:284–287CrossRef
20.
go back to reference Lachiewicz PF, Soileau ES (2013) Fixation, survival, and dislocation of jumbo acetabular components in revision hip arthroplasty. J Bone Jt Surg Am 95:543–548CrossRef Lachiewicz PF, Soileau ES (2013) Fixation, survival, and dislocation of jumbo acetabular components in revision hip arthroplasty. J Bone Jt Surg Am 95:543–548CrossRef
21.
go back to reference Whaley AL, Berry DJ, Harmsen WS (2001) Extra-large uncemented hemispherical acetabular components for revision total hip arthroplasty. J Bone Jt Surg Am 83:1352–1357CrossRef Whaley AL, Berry DJ, Harmsen WS (2001) Extra-large uncemented hemispherical acetabular components for revision total hip arthroplasty. J Bone Jt Surg Am 83:1352–1357CrossRef
22.
go back to reference Krismer M, Bauer R, Tschupik J, Mayrhofer P (1995) EBRA: a method to measure migration of acetabular components. J Biomech 28:1225–1236CrossRefPubMed Krismer M, Bauer R, Tschupik J, Mayrhofer P (1995) EBRA: a method to measure migration of acetabular components. J Biomech 28:1225–1236CrossRefPubMed
23.
go back to reference Krismer M, Stöckl B, Fischer M, Bauer R, Mayrhofer P, Ogon M (1996) Early migration predicts late aseptic failure of hip sockets. J Bone Jt Surg Br 78:422–426CrossRef Krismer M, Stöckl B, Fischer M, Bauer R, Mayrhofer P, Ogon M (1996) Early migration predicts late aseptic failure of hip sockets. J Bone Jt Surg Br 78:422–426CrossRef
24.
go back to reference Ilchmann T, Mjoberg B, Wingstrand H (1995) Measurement accuracy in acetabular cup wear. Three retrospective methods compared with Roentgen stereophotogrammetry. J Arthroplasty 10:636–642CrossRefPubMed Ilchmann T, Mjoberg B, Wingstrand H (1995) Measurement accuracy in acetabular cup wear. Three retrospective methods compared with Roentgen stereophotogrammetry. J Arthroplasty 10:636–642CrossRefPubMed
25.
go back to reference Abrahams JM, Kim YS, Callary SA, Ieso C, Costi K, Howie DW, Solomon LB (2017) The diagnostic performance of radiographic criteria to detect aseptic acetabular component loosening after revision total hip arthroplasty. Bone Jt J 99:458–464CrossRef Abrahams JM, Kim YS, Callary SA, Ieso C, Costi K, Howie DW, Solomon LB (2017) The diagnostic performance of radiographic criteria to detect aseptic acetabular component loosening after revision total hip arthroplasty. Bone Jt J 99:458–464CrossRef
26.
go back to reference Kim YS, Abrahams JM, Callary SA, Ieso C, Costi K, Howie DW, Solomon LB (2017) Proximal translation of %3e 1 mm within the first two years of revision total hip arthroplasty correctly predicts whether or not an acetabular component is loose in 80% of cases: a case-control study with confirmed intra-operative outcomes. Bone Jt J 99:465–474CrossRef Kim YS, Abrahams JM, Callary SA, Ieso C, Costi K, Howie DW, Solomon LB (2017) Proximal translation of %3e 1 mm within the first two years of revision total hip arthroplasty correctly predicts whether or not an acetabular component is loose in 80% of cases: a case-control study with confirmed intra-operative outcomes. Bone Jt J 99:465–474CrossRef
27.
go back to reference Paprosky WG, Perona PG, Lawrence JM (1994) Acetabular defect classification and surgical reconstruction in revision arthroplasty. A 6-year follow-up evaluation. J Arthroplasty 9:33–44CrossRefPubMed Paprosky WG, Perona PG, Lawrence JM (1994) Acetabular defect classification and surgical reconstruction in revision arthroplasty. A 6-year follow-up evaluation. J Arthroplasty 9:33–44CrossRefPubMed
28.
go back to reference Harris WH (1969) Traumatic arthritis of the hip after dislocation and acetabular fractures: treatment by mold arthroplasty. An end-result study using a new method of result evaluation. J Bone Jt Surg Am 51:737–755CrossRef Harris WH (1969) Traumatic arthritis of the hip after dislocation and acetabular fractures: treatment by mold arthroplasty. An end-result study using a new method of result evaluation. J Bone Jt Surg Am 51:737–755CrossRef
29.
go back to reference DeLee JG, Charnley J (1976) Radiological demarcation of cemented sockets in total hip replacement. Clin Orthop Relat Res 121:20–32 DeLee JG, Charnley J (1976) Radiological demarcation of cemented sockets in total hip replacement. Clin Orthop Relat Res 121:20–32
30.
go back to reference Zicat B, Engh CA, Gokcen E (1995) Patterns of osteolysis around total hip components inserted with and without cement. J Bone Jt Surg Am 77:432–439CrossRef Zicat B, Engh CA, Gokcen E (1995) Patterns of osteolysis around total hip components inserted with and without cement. J Bone Jt Surg Am 77:432–439CrossRef
31.
go back to reference Stihsen C, Rath C, Radl R, Saalabian AA, Materna W, Rehak P, Windhager R (2013) Early migration characteristics of a 180 degrees porous-coated cup with 1-mm press fit. Arch Orthop Trauma Surg 133:707–712CrossRefPubMed Stihsen C, Rath C, Radl R, Saalabian AA, Materna W, Rehak P, Windhager R (2013) Early migration characteristics of a 180 degrees porous-coated cup with 1-mm press fit. Arch Orthop Trauma Surg 133:707–712CrossRefPubMed
32.
go back to reference Murray DW, Carr AJ, Bulstrode C (1993) Survival analysis of joint replacements. J Bone Jt Surg Br 75:697–704CrossRef Murray DW, Carr AJ, Bulstrode C (1993) Survival analysis of joint replacements. J Bone Jt Surg Br 75:697–704CrossRef
33.
go back to reference Stihsen C, Pabinger C, Radl R, Rehak P, Windhager R (2008) Migration of the Duraloc cup after 5 years. Int Orthop 32:791–794CrossRefPubMed Stihsen C, Pabinger C, Radl R, Rehak P, Windhager R (2008) Migration of the Duraloc cup after 5 years. Int Orthop 32:791–794CrossRefPubMed
34.
go back to reference Fehring KA, Owen JR, Kurdin AA, Wayne JS, Jiranek WA (2014) Initial stability of press-fit acetabular components under rotational forces. J Arthroplasty 29:1038–1042CrossRefPubMed Fehring KA, Owen JR, Kurdin AA, Wayne JS, Jiranek WA (2014) Initial stability of press-fit acetabular components under rotational forces. J Arthroplasty 29:1038–1042CrossRefPubMed
35.
go back to reference Schmalzried TP, Wessinger SJ, Hill GE, Harris WH (1994) The Harris-Galante porous acetabular component press-fit without screw fixation. Five-year radiographic analysis of primary cases. J Arthroplasty 9:235–242CrossRefPubMed Schmalzried TP, Wessinger SJ, Hill GE, Harris WH (1994) The Harris-Galante porous acetabular component press-fit without screw fixation. Five-year radiographic analysis of primary cases. J Arthroplasty 9:235–242CrossRefPubMed
36.
go back to reference Stiehl JB, MacMillan E, Skrade DA (1991) Mechanical stability of porous-coated acetabular components in total hip arthroplasty. J Arthroplasty 6:295–300CrossRefPubMed Stiehl JB, MacMillan E, Skrade DA (1991) Mechanical stability of porous-coated acetabular components in total hip arthroplasty. J Arthroplasty 6:295–300CrossRefPubMed
37.
go back to reference Streit MR, Weiss S, Andreas F, Bruckner T, Walker T, Kretzer JP, Ewerbeck V, Merle C (2014) 10-year results of the uncemented Allofit press-fit cup in young patients. Acta Orthop 85:368–374CrossRefPubMedPubMedCentral Streit MR, Weiss S, Andreas F, Bruckner T, Walker T, Kretzer JP, Ewerbeck V, Merle C (2014) 10-year results of the uncemented Allofit press-fit cup in young patients. Acta Orthop 85:368–374CrossRefPubMedPubMedCentral
38.
go back to reference Kwong LM, O'Connor DO, Sedlacek RC, Krushell RJ, Maloney WJ, Harris WH (1994) A quantitative in vitro assessment of fit and screw fixation on the stability of a cementless hemispherical acetabular component. J Arthroplasty 9:163–170CrossRefPubMed Kwong LM, O'Connor DO, Sedlacek RC, Krushell RJ, Maloney WJ, Harris WH (1994) A quantitative in vitro assessment of fit and screw fixation on the stability of a cementless hemispherical acetabular component. J Arthroplasty 9:163–170CrossRefPubMed
39.
go back to reference Dora C, Houweling M, Koch P, Sierra RJ (2007) Iliopsoas impingement after total hip replacement: the results of non-operative management, tenotomy or acetabular revision. J Bone Jt Surg Br 89:1031–1035CrossRef Dora C, Houweling M, Koch P, Sierra RJ (2007) Iliopsoas impingement after total hip replacement: the results of non-operative management, tenotomy or acetabular revision. J Bone Jt Surg Br 89:1031–1035CrossRef
40.
go back to reference O’Sullivan M, Tai CC, Richards S, Skyrme AD, Walter WL, Wlater WK (2007) Iliopsoas tendonitis a complication after total hip arthroplasty. J Arthroplasty 22:166–170CrossRefPubMed O’Sullivan M, Tai CC, Richards S, Skyrme AD, Walter WL, Wlater WK (2007) Iliopsoas tendonitis a complication after total hip arthroplasty. J Arthroplasty 22:166–170CrossRefPubMed
41.
go back to reference Nwankwo C, Dong NN, Heffernan CD, Ries MD (2014) Do jumbo cups cause hip center elevation in revision THA? A computer simulation. Clin Orthop Relat Res 472:572–576CrossRefPubMed Nwankwo C, Dong NN, Heffernan CD, Ries MD (2014) Do jumbo cups cause hip center elevation in revision THA? A computer simulation. Clin Orthop Relat Res 472:572–576CrossRefPubMed
42.
go back to reference Cyteval C, Sarrabere MP, Cottin A, Assi C, Morcos L, Maury P, Taourel P (2003) Iliopsoas impingement on the acetabular component: radiologic and computed tomography findings of a rare hip prostehsis complication in eight cases. J Comput Assist Tomogr 27:183–188CrossRefPubMed Cyteval C, Sarrabere MP, Cottin A, Assi C, Morcos L, Maury P, Taourel P (2003) Iliopsoas impingement on the acetabular component: radiologic and computed tomography findings of a rare hip prostehsis complication in eight cases. J Comput Assist Tomogr 27:183–188CrossRefPubMed
43.
go back to reference Overgaard S, Lind M, Glerup H, Bünger C, Søballe K (1998) Porous-coated versus grit-blasted surface texture of hydroxyapatite-coated implants during controlled micromotion: mechanical and histomorphometric results. J Arthroplasty 13:449–458CrossRefPubMed Overgaard S, Lind M, Glerup H, Bünger C, Søballe K (1998) Porous-coated versus grit-blasted surface texture of hydroxyapatite-coated implants during controlled micromotion: mechanical and histomorphometric results. J Arthroplasty 13:449–458CrossRefPubMed
44.
go back to reference Mukherjee K, Gupta S (2016) Bone ingrowth around porous-coated acetabular implant: a three-dimensional finite element study using mechanoregulatory algorithm. Biomech Model Mechanobiol 15:389–403CrossRefPubMed Mukherjee K, Gupta S (2016) Bone ingrowth around porous-coated acetabular implant: a three-dimensional finite element study using mechanoregulatory algorithm. Biomech Model Mechanobiol 15:389–403CrossRefPubMed
45.
go back to reference D’Lima DD, Lemperle SM, Chen PC, Holmes RE, Colwell CW Jr (1998) Bone response to implant surface morphology. J Arthroplasty 13:928–934CrossRefPubMed D’Lima DD, Lemperle SM, Chen PC, Holmes RE, Colwell CW Jr (1998) Bone response to implant surface morphology. J Arthroplasty 13:928–934CrossRefPubMed
46.
go back to reference Little NJ, Busch CA, Gallagher JA, Rorabeck CH, Bourne RB (2009) Acetabular polyethylene wear and acetabular inclination and femoral offset. Clin Orthop Relat Res 467:2895–2900CrossRefPubMedPubMedCentral Little NJ, Busch CA, Gallagher JA, Rorabeck CH, Bourne RB (2009) Acetabular polyethylene wear and acetabular inclination and femoral offset. Clin Orthop Relat Res 467:2895–2900CrossRefPubMedPubMedCentral
47.
go back to reference Patil S, Bergula A, Chen PC, Colwell CW Jr, D’Lima DD (2003) Polyethylene wear and acetabular component orientation. J Bone Jt Surg Am 85(Suppl 4):56–63CrossRef Patil S, Bergula A, Chen PC, Colwell CW Jr, D’Lima DD (2003) Polyethylene wear and acetabular component orientation. J Bone Jt Surg Am 85(Suppl 4):56–63CrossRef
48.
go back to reference Lachiewicz PF, Watters TS (2016) The jumbo acetabular component for acetabular revision: curtain calls and caveats. Bone Jt J 98(1 Suppl A):64–67CrossRef Lachiewicz PF, Watters TS (2016) The jumbo acetabular component for acetabular revision: curtain calls and caveats. Bone Jt J 98(1 Suppl A):64–67CrossRef
49.
go back to reference Jafari SM, Bender B, Coyle C, Parvizi J, Sharkey PF, Hozack WJ (2010) Do tantalum and titanium cups show similar results in revision hip arthroplasty? Clin Orthop Relat Res 468:459–465CrossRefPubMed Jafari SM, Bender B, Coyle C, Parvizi J, Sharkey PF, Hozack WJ (2010) Do tantalum and titanium cups show similar results in revision hip arthroplasty? Clin Orthop Relat Res 468:459–465CrossRefPubMed
50.
go back to reference Ilchmann T (1997) Radiographic assessment of cup migration and wear after hip replacement. Acta Orthop Scand Suppl 276:1–26PubMed Ilchmann T (1997) Radiographic assessment of cup migration and wear after hip replacement. Acta Orthop Scand Suppl 276:1–26PubMed
51.
go back to reference Hirakawa K, Bauer TW, Stulberg BN, Wilde AH, Secic M (1996) Characterization and comparison of wear debris from failed total hip implants of different types. J Bone Jt Surg Am 78:1235–1243CrossRef Hirakawa K, Bauer TW, Stulberg BN, Wilde AH, Secic M (1996) Characterization and comparison of wear debris from failed total hip implants of different types. J Bone Jt Surg Am 78:1235–1243CrossRef
52.
go back to reference Devane PA, Horne JG, Ashmore A, Mutimer J, Kim W, Stanley J (2017) Highly cross-linked polyethylene reduces wear and revision rates in total hip arthroplasty: a 10-year double-blinded randomized controlled trial. J Bone Jt Surg Am 99:1703–1714CrossRef Devane PA, Horne JG, Ashmore A, Mutimer J, Kim W, Stanley J (2017) Highly cross-linked polyethylene reduces wear and revision rates in total hip arthroplasty: a 10-year double-blinded randomized controlled trial. J Bone Jt Surg Am 99:1703–1714CrossRef
Metadata
Title
Acetabular revision arthroplasty using press-fitted jumbo cups: an average 10-year follow-up study
Authors
Jun-Ki Moon
Jaejoon Ryu
Yeesuk Kim
Jae-Hyuk Yang
Kyu-Tae Hwang
Young-Ho Kim
Publication date
01-08-2019
Publisher
Springer Berlin Heidelberg
Published in
Archives of Orthopaedic and Trauma Surgery / Issue 8/2019
Print ISSN: 0936-8051
Electronic ISSN: 1434-3916
DOI
https://doi.org/10.1007/s00402-019-03214-7

Other articles of this Issue 8/2019

Archives of Orthopaedic and Trauma Surgery 8/2019 Go to the issue