Skip to main content
Top
Published in: Clinical Orthopaedics and Related Research® 2/2010

01-02-2010 | Symposium: Papers Presented at the Hip Society Meetings 2009

Do Tantalum and Titanium Cups Show Similar Results in Revision Hip Arthroplasty?

Authors: S. Mehdi Jafari, MD, Benjamin Bender, MD, Catelyn Coyle, BA, Javad Parvizi, MD, FRCS, Peter F. Sharkey, MD, William J. Hozack, MD

Published in: Clinical Orthopaedics and Related Research® | Issue 2/2010

Login to get access

Abstract

Porous surfaces are intended to enhance osteointegration of cementless implants. Tantalum has been introduced in an effort to enhance osseointegration potential of uncemented components. We therefore compared the clinical outcome of acetabular components with two different porous surfaces. We retrospectively reviewed 283 patients (295 hips) who underwent cementless revision hip arthroplasty with either an HA-coated titanium cup (207 patients, 214 hips) or porous tantalum cup (79 patients, 81 hips). The minimum followup was 24 months in both groups (titanium: average 51.8 months, range, 24–98 months; tantalum: average, 35.4 months, range, 24–63 months). The titanium and tantalum groups had a mechanical failure rate (clinical plus radiographic) of 8% and 6%, respectively. In hips with minor bone deficiency (type 1, 2A, 2B using the classification of Paprosky et al.), 6% of titanium cups and 4% of tantalum cups failed. In hips with major bone deficiency (type 2C, 3), 24% of titanium cups and 12% of tantalum cups developed failure. In the major bone deficiency group, the tantalum cups had fewer numbers of lucent zones around the cup. Eighty-two percent of titanium cups that failed did so at 6 months postoperatively or later, whereas 80% of tantalum cups that failed did so in less than 6 months. Radiographically in the major group, tantalum cups yielded better fixation.
Level of Evidence: Level III, retrospective comparative study. See the Guidelines for Authors for a complete description of levels of evidence.
Literature
1.
go back to reference Bobyn JD, Stackpool GJ, Hacking SA, Tanzer M, Krygier JJ. Characteristics of bone ingrowth and interface mechanics of a new porous tantalum biomaterial. J Bone Joint Surg Br. 1999;81:907–914.CrossRefPubMed Bobyn JD, Stackpool GJ, Hacking SA, Tanzer M, Krygier JJ. Characteristics of bone ingrowth and interface mechanics of a new porous tantalum biomaterial. J Bone Joint Surg Br. 1999;81:907–914.CrossRefPubMed
2.
go back to reference Bobyn JD, Toh KK, Hacking SA, Tanzer M, Krygier JJ. Tissue response to porous tantalum acetabular cups: a canine model. J Arthroplasty. 1999;14:347–354.CrossRefPubMed Bobyn JD, Toh KK, Hacking SA, Tanzer M, Krygier JJ. Tissue response to porous tantalum acetabular cups: a canine model. J Arthroplasty. 1999;14:347–354.CrossRefPubMed
3.
go back to reference Boscainos PJ, Kellett CF, Maury AC, Backstein D, Gross AE. Management of periacetabular bone loss in revision hip arthroplasty. Clin Orthop Relat Res. 2007;465:159–165.PubMed Boscainos PJ, Kellett CF, Maury AC, Backstein D, Gross AE. Management of periacetabular bone loss in revision hip arthroplasty. Clin Orthop Relat Res. 2007;465:159–165.PubMed
4.
go back to reference Cohen R. A porous tantalum trabecular metal: basic science. Am J Orthop. 2002;31:216–217.PubMed Cohen R. A porous tantalum trabecular metal: basic science. Am J Orthop. 2002;31:216–217.PubMed
5.
go back to reference DeLee JG, Charnley J. Radiological demarcation of cemented sockets in total hip replacement. Clin Orthop Relat Res. 1976;121:20–32.PubMed DeLee JG, Charnley J. Radiological demarcation of cemented sockets in total hip replacement. Clin Orthop Relat Res. 1976;121:20–32.PubMed
6.
go back to reference Dorairajan A, Reddy RM, Krikler S. Outcome of acetabular revision using an uncemented hydroxyapatite-coated component: two- to five-year results and review. J Arthroplasty. 2005;20:209–218.CrossRefPubMed Dorairajan A, Reddy RM, Krikler S. Outcome of acetabular revision using an uncemented hydroxyapatite-coated component: two- to five-year results and review. J Arthroplasty. 2005;20:209–218.CrossRefPubMed
7.
go back to reference Gruen TA, Poggie RA, Lewallen DG, Hanssen AD, Lewis RJ, O’Keefe TJ, Stulberg SD, Sutherland CJ. Radiographic evaluation of a monoblock acetabular component: a multicenter study with 2- to 5-year results. J Arthroplasty. 2005;20:369–378.CrossRefPubMed Gruen TA, Poggie RA, Lewallen DG, Hanssen AD, Lewis RJ, O’Keefe TJ, Stulberg SD, Sutherland CJ. Radiographic evaluation of a monoblock acetabular component: a multicenter study with 2- to 5-year results. J Arthroplasty. 2005;20:369–378.CrossRefPubMed
8.
go back to reference Hanssen AD, Lewallen DG. Modular acetabular augments: composite void fillers. Orthopedics. 2005;28:971–972.PubMed Hanssen AD, Lewallen DG. Modular acetabular augments: composite void fillers. Orthopedics. 2005;28:971–972.PubMed
9.
go back to reference Kim WY, Greidanus NV, Duncan CP, Masri BA, Garbuz DS. Porous tantalum uncemented acetabular shells in revision total hip replacement: two to four year clinical and radiographic results. Hip Int. 2008;18:17–22.PubMed Kim WY, Greidanus NV, Duncan CP, Masri BA, Garbuz DS. Porous tantalum uncemented acetabular shells in revision total hip replacement: two to four year clinical and radiographic results. Hip Int. 2008;18:17–22.PubMed
10.
go back to reference Klika AK, Murray TG, Darwiche H, Barsoum W.K. Options for acetabular fixation surfaces. J Long Term Eff Med Implants. 2007;17:187–192.PubMed Klika AK, Murray TG, Darwiche H, Barsoum W.K. Options for acetabular fixation surfaces. J Long Term Eff Med Implants. 2007;17:187–192.PubMed
11.
go back to reference Kokubo T, Kim HM, Kawashita M. Novel bioactive materials with different mechanical properties. Biomaterials. 2003;24:2161–2175.CrossRefPubMed Kokubo T, Kim HM, Kawashita M. Novel bioactive materials with different mechanical properties. Biomaterials. 2003;24:2161–2175.CrossRefPubMed
12.
go back to reference Kurtz S, Ong K, Lau E, Mowat F, Halpern M. Projections of primary and revision hip and knee arthroplasty in the United States from 2005 to 2030. J Bone Joint Surg Am. 2007;89:780–785.CrossRefPubMed Kurtz S, Ong K, Lau E, Mowat F, Halpern M. Projections of primary and revision hip and knee arthroplasty in the United States from 2005 to 2030. J Bone Joint Surg Am. 2007;89:780–785.CrossRefPubMed
13.
go back to reference Levine BR, Sporer S, Poggie RA, Della Valle CJ, Jacobs JJ. Experimental and clinical performance of porous tantalum in orthopedic surgery. Biomaterials. 2006;27:4671–4681.CrossRefPubMed Levine BR, Sporer S, Poggie RA, Della Valle CJ, Jacobs JJ. Experimental and clinical performance of porous tantalum in orthopedic surgery. Biomaterials. 2006;27:4671–4681.CrossRefPubMed
14.
go back to reference Malkani AL, Price MR, Crawford CH 3rd, Baker DL. Acetabular component revision using a porous tantalum biomaterial a case series. J Arthroplasty. 2008 Sep 26 [Epub ahead of print]. Malkani AL, Price MR, Crawford CH 3rd, Baker DL. Acetabular component revision using a porous tantalum biomaterial a case series. J Arthroplasty. 2008 Sep 26 [Epub ahead of print].
15.
go back to reference Matsuno H, Yokoyama A, Watari F, Uo M, Kawasaki T. Biocompatibility and osteogenesis of refractory metal implants, titanium, hafnium, niobium, tantalum and rhenium. Biomaterials. 2001;22:1253–1262.CrossRefPubMed Matsuno H, Yokoyama A, Watari F, Uo M, Kawasaki T. Biocompatibility and osteogenesis of refractory metal implants, titanium, hafnium, niobium, tantalum and rhenium. Biomaterials. 2001;22:1253–1262.CrossRefPubMed
16.
go back to reference Miyaza T, Kim HM, Kokubo T, Ohtsuki C, Kato H, Nakamura T. Mechanism of bonelike apatite formation on bioactive tantalum metal in a simulated body fluid. Biomaterials. 2002;23:827–832.CrossRefPubMed Miyaza T, Kim HM, Kokubo T, Ohtsuki C, Kato H, Nakamura T. Mechanism of bonelike apatite formation on bioactive tantalum metal in a simulated body fluid. Biomaterials. 2002;23:827–832.CrossRefPubMed
17.
go back to reference Moore MS, McAuley JP, Young AM, Engh CA, Sr. Radiographic signs of osseointegration in porous-coated acetabular components. Clin Orthop Relat Res. 2006;444:176–183.CrossRefPubMed Moore MS, McAuley JP, Young AM, Engh CA, Sr. Radiographic signs of osseointegration in porous-coated acetabular components. Clin Orthop Relat Res. 2006;444:176–183.CrossRefPubMed
19.
go back to reference Paprosky WG, Perona PG, Lawrence JM. Acetabular defect classification and surgical reconstruction in revision arthroplasty. A 6-year follow-up evaluation. J Arthroplasty. 1994;9:33–44.CrossRefPubMed Paprosky WG, Perona PG, Lawrence JM. Acetabular defect classification and surgical reconstruction in revision arthroplasty. A 6-year follow-up evaluation. J Arthroplasty. 1994;9:33–44.CrossRefPubMed
20.
go back to reference Reikerås O, Gunderson RB. Failure of HA coating on a gritblasted acetabular cup: 155 patients followed for 7–10 years. Acta Orthop Scand. 2002;73:104–108.PubMedCrossRef Reikerås O, Gunderson RB. Failure of HA coating on a gritblasted acetabular cup: 155 patients followed for 7–10 years. Acta Orthop Scand. 2002;73:104–108.PubMedCrossRef
21.
go back to reference Rodriguez JA. Acetabular fixation options: notes from the other side. J Arthroplasty. 2006;21:93–96.CrossRefPubMed Rodriguez JA. Acetabular fixation options: notes from the other side. J Arthroplasty. 2006;21:93–96.CrossRefPubMed
22.
go back to reference Siegmeth A, Duncan CP, Masri BA, Kim WY, Garbuz DS. Modular tantalum augments for acetabular defects in revision hip arthroplasty. Clin Orthop Relat Res. 2009;467:199–205.CrossRefPubMed Siegmeth A, Duncan CP, Masri BA, Kim WY, Garbuz DS. Modular tantalum augments for acetabular defects in revision hip arthroplasty. Clin Orthop Relat Res. 2009;467:199–205.CrossRefPubMed
23.
go back to reference Sporer SM, Paprosky WG, O’Rourke MR. Managing bone loss in acetabular revision. Instr Course Lect. 2006;55:287–297.PubMed Sporer SM, Paprosky WG, O’Rourke MR. Managing bone loss in acetabular revision. Instr Course Lect. 2006;55:287–297.PubMed
24.
go back to reference Stiehl JB. Trabecular metal in hip reconstructive surgery. Orthopedics. 2005;28:662–670.PubMed Stiehl JB. Trabecular metal in hip reconstructive surgery. Orthopedics. 2005;28:662–670.PubMed
25.
go back to reference Templeton JE, Callaghan JJ, Goetz DD, Sullivan PM, Johnston RC. Revision of a cemented acetabular component to a cementless acetabular component. A ten to fourteen-year follow-up study. J Bone Joint Surg Am. 2001;83:1706–1711.PubMed Templeton JE, Callaghan JJ, Goetz DD, Sullivan PM, Johnston RC. Revision of a cemented acetabular component to a cementless acetabular component. A ten to fourteen-year follow-up study. J Bone Joint Surg Am. 2001;83:1706–1711.PubMed
26.
go back to reference Unger AS, Lewis RJ, Gruen T. Evaluation of a porous tantalum uncemented acetabular cup in revision total hip arthroplasty: clinical and radiological results of 60 hips. J Arthroplasty. 2005;20:1002–1009.CrossRefPubMed Unger AS, Lewis RJ, Gruen T. Evaluation of a porous tantalum uncemented acetabular cup in revision total hip arthroplasty: clinical and radiological results of 60 hips. J Arthroplasty. 2005;20:1002–1009.CrossRefPubMed
27.
go back to reference Van Kleunen JP, Lee GC, Lementowski PW, Nelson CL, Garino JP. Acetabular revisions using trabecular metal cups and augments. J Arthroplasty. 2009 Mar 31 [Epub ahead of print]. Van Kleunen JP, Lee GC, Lementowski PW, Nelson CL, Garino JP. Acetabular revisions using trabecular metal cups and augments. J Arthroplasty. 2009 Mar 31 [Epub ahead of print].
Metadata
Title
Do Tantalum and Titanium Cups Show Similar Results in Revision Hip Arthroplasty?
Authors
S. Mehdi Jafari, MD
Benjamin Bender, MD
Catelyn Coyle, BA
Javad Parvizi, MD, FRCS
Peter F. Sharkey, MD
William J. Hozack, MD
Publication date
01-02-2010
Publisher
Springer-Verlag
Published in
Clinical Orthopaedics and Related Research® / Issue 2/2010
Print ISSN: 0009-921X
Electronic ISSN: 1528-1132
DOI
https://doi.org/10.1007/s11999-009-1090-5

Other articles of this Issue 2/2010

Clinical Orthopaedics and Related Research® 2/2010 Go to the issue

Letter to the Editor

Reply to Letter to the Editor

Symposium: Papers Presented at the Hip Society Meetings 2009

Iliopsoas Bursa Injections Can be Beneficial for Pain after Total Hip Arthroplasty

Symposium: Papers Presented at the Hip Society Meetings 2009

The Classic: Chapter XVIII. Operative Treatment in Chronic Articular Ostitis

Symposium: Papers Presented at the Hip Society Meetings 2009

Failure of the Durom Metasul® Acetabular Component