Acetabular Polyethylene Wear and Acetabular Inclination and Femoral Offset

Authors: Nick J. Little, MSc, MRCS, Constant A. Busch, MD, FRCS, John A. Gallagher, MD, FRACS, Cecil H. Rorabeck, MD, FRCSC, Robert B. Bourne, MD, FRCSC

Published in: Clinical Orthopaedics and Related Research® | Issue 11/2009

Login to get access

Abstract

Restoration of femoral offset and acetabular inclination may have an effect on polyethylene (PE) wear in THA. We therefore assessed the effect of femoral offset and acetabular inclination (angle) on acetabular conventional (not highly cross-linked) PE wear in uncemented THA. We prospectively followed 43 uncemented THAs for a minimum of 49 months (mean, 64 months; range, 49–88 months). Radiographs were assessed for femoral offset, acetabular inclination, and conventional PE wear. The mean (± standard deviation) linear wear rate in all THAs was 0.14 mm/year (± 0.01 mm/year) and the mean volumetric wear rate was 53.1 mm3/year (± 5.5 mm3/year). In THAs with an acetabular angle less than 45°, the mean wear was 0.12 mm/year (± 0.01 mm/year) compared with 0.18 mm/year (± 0.02 mm/year) in those with a reconstructed acetabular angle greater than 45°. Reproduction of a reconstructed femoral offset to within 5 mm of the native femoral offset was associated with a reduction in conventional PE wear (0.12 mm/year versus 0.16 mm/year). Careful placement of the acetabular component to ensure an acetabular angle less than 45° in the reconstructed hip allows for reduced conventional PE wear.
Level of Evidence: Level II, prospective study. See Guidelines for Authors for a complete description of levels of evidence.
Literature
1.
go back to reference Bankston AB, Cates H, Ritter MA, Keating EM, Faris PM. Polyethylene wear in total hip arthroplasty. Clin Orthop Relat Res. 1995;317:7–13.PubMed Bankston AB, Cates H, Ritter MA, Keating EM, Faris PM. Polyethylene wear in total hip arthroplasty. Clin Orthop Relat Res. 1995;317:7–13.PubMed
2.
go back to reference Bankston AB, Faris PM, Keating EM, Ritter MA. Polyethylene wear in total hip arthroplasty in patient-matched groups: a comparison of stainless steel, cobalt chrome, and titanium-bearing surfaces. J Arthroplasty. 1993;8:315–322.PubMedCrossRef Bankston AB, Faris PM, Keating EM, Ritter MA. Polyethylene wear in total hip arthroplasty in patient-matched groups: a comparison of stainless steel, cobalt chrome, and titanium-bearing surfaces. J Arthroplasty. 1993;8:315–322.PubMedCrossRef
3.
go back to reference Barrack RL. Factors influencing polyethylene wear in total joint arthroplasty. Orthopedics. 1998;21:937–940.PubMed Barrack RL. Factors influencing polyethylene wear in total joint arthroplasty. Orthopedics. 1998;21:937–940.PubMed
4.
go back to reference Charles MN, Bourne RB, Davey JR, Greenwald AS, Morrey BF, Rorabeck CH. Soft-tissue balancing of the hip: the role of femoral offset restoration. Instr Course Lect. 2005;54:131–141.PubMed Charles MN, Bourne RB, Davey JR, Greenwald AS, Morrey BF, Rorabeck CH. Soft-tissue balancing of the hip: the role of femoral offset restoration. Instr Course Lect. 2005;54:131–141.PubMed
5.
go back to reference Del Schutte H Jr, Lipman AJ, Bannar SM, Livermore JT, Ilstrup D, Morrey BF. Effects of acetabular abduction on cup wear rates in total hip arthroplasty. J Arthroplasty. 1998;13:621–626.PubMedCrossRef Del Schutte H Jr, Lipman AJ, Bannar SM, Livermore JT, Ilstrup D, Morrey BF. Effects of acetabular abduction on cup wear rates in total hip arthroplasty. J Arthroplasty. 1998;13:621–626.PubMedCrossRef
6.
go back to reference Devane PA, Horne JG. Assessment of polyethylene wear in total hip replacement. Clin Orthop Relat Res. 1999;369:59–72.PubMedCrossRef Devane PA, Horne JG. Assessment of polyethylene wear in total hip replacement. Clin Orthop Relat Res. 1999;369:59–72.PubMedCrossRef
7.
go back to reference Eggli S, z’Brun S, Gerber C, Ganz R. Comparison of polyethylene wear with femoral heads of 22 mm and 32 mm: a prospective, randomised study. J Bone Joint Surg Br. 2002;84:447–451.PubMedCrossRef Eggli S, z’Brun S, Gerber C, Ganz R. Comparison of polyethylene wear with femoral heads of 22 mm and 32 mm: a prospective, randomised study. J Bone Joint Surg Br. 2002;84:447–451.PubMedCrossRef
8.
go back to reference Gaffey JL, Callaghan JJ, Pedersen DR, Goetz DD, Sullivan PM, Johnston RC. Cementless acetabular fixation at fifteen years: a comparison with the same surgeon’s results following acetabular fixation with cement. J Bone Joint Surg Am. 2004;86:257–261.PubMed Gaffey JL, Callaghan JJ, Pedersen DR, Goetz DD, Sullivan PM, Johnston RC. Cementless acetabular fixation at fifteen years: a comparison with the same surgeon’s results following acetabular fixation with cement. J Bone Joint Surg Am. 2004;86:257–261.PubMed
9.
go back to reference Glyn-Jones S, Lardy-Smith P, Gill HS, Murray DW. The creep and wear of highly cross-linked polyethylene: a three-year randomised, controlled trial using radiostereometric analysis. J Bone Joint Surg Br. 2008;90:556–561.PubMedCrossRef Glyn-Jones S, Lardy-Smith P, Gill HS, Murray DW. The creep and wear of highly cross-linked polyethylene: a three-year randomised, controlled trial using radiostereometric analysis. J Bone Joint Surg Br. 2008;90:556–561.PubMedCrossRef
10.
go back to reference Goosen JH, Verheyen CC, Tulp NJ. Mid-term wear characteristics of an uncemented acetabular component. J Bone Joint Surg Br. 2005;87:1475–1479.PubMedCrossRef Goosen JH, Verheyen CC, Tulp NJ. Mid-term wear characteristics of an uncemented acetabular component. J Bone Joint Surg Br. 2005;87:1475–1479.PubMedCrossRef
11.
go back to reference Hansen T, Otto M, Buchhorn GH, Scharnweber D, Gaumann A, Delank KS, Eckardt A, Willert HG, Kriegsmann J, Kirkpatrick CJ. New aspects in the histological examination of polyethylene wear particles in failed total joint replacements. Acta Histochem. 2002;104:263–269.PubMedCrossRef Hansen T, Otto M, Buchhorn GH, Scharnweber D, Gaumann A, Delank KS, Eckardt A, Willert HG, Kriegsmann J, Kirkpatrick CJ. New aspects in the histological examination of polyethylene wear particles in failed total joint replacements. Acta Histochem. 2002;104:263–269.PubMedCrossRef
12.
go back to reference Hirakawa K, Mitsugi N, Koshino T, Saito T, Hirasawa Y, Kubo T. Effect of acetabular cup position and orientation in cemented total hip arthroplasty. Clin Orthop Relat Res. 2001;388:135–142.PubMedCrossRef Hirakawa K, Mitsugi N, Koshino T, Saito T, Hirasawa Y, Kubo T. Effect of acetabular cup position and orientation in cemented total hip arthroplasty. Clin Orthop Relat Res. 2001;388:135–142.PubMedCrossRef
13.
go back to reference Howie DW, Vernon-Roberts B, Oakeshott R, Manthey B. A rat model of resorption of bone at the cement-bone interface in the presence of polyethylene wear particles. J Bone Joint Surg Am. 1988;70:257–263.PubMed Howie DW, Vernon-Roberts B, Oakeshott R, Manthey B. A rat model of resorption of bone at the cement-bone interface in the presence of polyethylene wear particles. J Bone Joint Surg Am. 1988;70:257–263.PubMed
14.
go back to reference Johnsen SP, Sorensen HT, Lucht U, Soballe K, Overgaard S, Pedersen AB. Patient-related predictors of implant failure after primary total hip replacement in the initial, short- and long-terms: a nationwide Danish follow-up study including 36,984 patients. J Bone Joint Surg Br. 2006;88:1303–1308.PubMedCrossRef Johnsen SP, Sorensen HT, Lucht U, Soballe K, Overgaard S, Pedersen AB. Patient-related predictors of implant failure after primary total hip replacement in the initial, short- and long-terms: a nationwide Danish follow-up study including 36,984 patients. J Bone Joint Surg Br. 2006;88:1303–1308.PubMedCrossRef
15.
go back to reference Kligman M, Michael H, Roffman M. The effect of abduction differences between cup and contralateral acetabular angle on polyethylene component wear. Orthopedics. 2002;25:65–67.PubMed Kligman M, Michael H, Roffman M. The effect of abduction differences between cup and contralateral acetabular angle on polyethylene component wear. Orthopedics. 2002;25:65–67.PubMed
16.
go back to reference Lewinnek GE, Lewis JL, Tarr R, Compere CL, Zimmerman JR. Dislocations after total hip-replacement arthroplasties. J Bone Joint Surg Am. 1978;60:217–220.PubMed Lewinnek GE, Lewis JL, Tarr R, Compere CL, Zimmerman JR. Dislocations after total hip-replacement arthroplasties. J Bone Joint Surg Am. 1978;60:217–220.PubMed
17.
go back to reference Livermore J, Ilstrup D, Morrey B. Effect of femoral head size on wear of the polyethylene acetabular component. J Bone Joint Surg Am. 1990;72:518–528.PubMed Livermore J, Ilstrup D, Morrey B. Effect of femoral head size on wear of the polyethylene acetabular component. J Bone Joint Surg Am. 1990;72:518–528.PubMed
18.
go back to reference Martell JM, Berdia S. Determination of polyethylene wear in total hip replacements with use of digital radiographs. J Bone Joint Surg Am. 1997;79:1635–1641.PubMed Martell JM, Berdia S. Determination of polyethylene wear in total hip replacements with use of digital radiographs. J Bone Joint Surg Am. 1997;79:1635–1641.PubMed
19.
go back to reference McCalden RW, Naudie DD, Yuan X, Bourne RB. Radiographic methods for the assessment of polyethylene wear after total hip arthroplasty. J Bone Joint Surg Am. 2005;87:2323–2334.PubMedCrossRef McCalden RW, Naudie DD, Yuan X, Bourne RB. Radiographic methods for the assessment of polyethylene wear after total hip arthroplasty. J Bone Joint Surg Am. 2005;87:2323–2334.PubMedCrossRef
20.
go back to reference Nogler M, Kessler O, Prassl A, Donnelly B, Streicher R, Sledge JB, Krismer M. Reduced variability of acetabular cup positioning with use of an imageless navigation system. Clin Orthop Relat Res. 2004;426:159–163.PubMedCrossRef Nogler M, Kessler O, Prassl A, Donnelly B, Streicher R, Sledge JB, Krismer M. Reduced variability of acetabular cup positioning with use of an imageless navigation system. Clin Orthop Relat Res. 2004;426:159–163.PubMedCrossRef
21.
go back to reference Patil S, Bergula A, Chen PC, Colwell CW Jr, D’Lima DD. Polyethylene wear and acetabular component orientation. J Bone Joint Surg Am. 2003;85(suppl 4):56–63.PubMed Patil S, Bergula A, Chen PC, Colwell CW Jr, D’Lima DD. Polyethylene wear and acetabular component orientation. J Bone Joint Surg Am. 2003;85(suppl 4):56–63.PubMed
22.
go back to reference Robinson RP, Simonian PT, Gradisar IM, Ching RP. Joint motion and surface contact area related to component position in total hip arthroplasty. J Bone Joint Surg Br. 1997;79:140–146.PubMedCrossRef Robinson RP, Simonian PT, Gradisar IM, Ching RP. Joint motion and surface contact area related to component position in total hip arthroplasty. J Bone Joint Surg Br. 1997;79:140–146.PubMedCrossRef
23.
go back to reference Sakalkale DP, Sharkey PF, Eng K, Hozack WJ, Rothman RH. Effect of femoral component offset on polyethylene wear in total hip arthroplasty. Clin Orthop Relat Res. 2001;388:125–134.PubMedCrossRef Sakalkale DP, Sharkey PF, Eng K, Hozack WJ, Rothman RH. Effect of femoral component offset on polyethylene wear in total hip arthroplasty. Clin Orthop Relat Res. 2001;388:125–134.PubMedCrossRef
24.
go back to reference Schmalzried TP, Huk OL. Patient factors and wear in total hip arthroplasty. Clin Orthop Relat Res. 2004;418:94–97.PubMedCrossRef Schmalzried TP, Huk OL. Patient factors and wear in total hip arthroplasty. Clin Orthop Relat Res. 2004;418:94–97.PubMedCrossRef
Metadata
Title
Acetabular Polyethylene Wear and Acetabular Inclination and Femoral Offset
Authors
Nick J. Little, MSc, MRCS
Constant A. Busch, MD, FRCS
John A. Gallagher, MD, FRACS
Cecil H. Rorabeck, MD, FRCSC
Robert B. Bourne, MD, FRCSC
Publication date
01-11-2009
Publisher
Springer-Verlag
Published in
Clinical Orthopaedics and Related Research® / Issue 11/2009
Print ISSN: 0009-921X
Electronic ISSN: 1528-1132
DOI
https://doi.org/10.1007/s11999-009-0845-3

Other articles of this Issue 11/2009

Clinical Orthopaedics and Related Research® 11/2009 Go to the issue

Symposium: Selected Papers Presented at the 2008 Meeting of the Musculoskeletal Tumor Society

Soft-tissue Sarcoma Metastases Identified on Abdomen and Pelvis CT Imaging

Orthopaedic • Radiology • Pathology Conference

Thigh Pain in a 73-year-old Man

Symposium: Selected Papers Presented at the 2008 Meetings of the Musculoskeletal Tumor Society

Ernest Amory Codman, MD, 1869–1940