Skip to main content
Top
Published in: Archives of Orthopaedic and Trauma Surgery 11/2017

01-11-2017 | Arthroscopy and Sports Medicine

Radiolucent rings around bioabsorbable anchors after rotator cuff repair are not associated with clinical outcomes

Authors: Jin-Young Park, Suk-Hwan Jang, Kyung-Soo Oh, Yi Jin Li

Published in: Archives of Orthopaedic and Trauma Surgery | Issue 11/2017

Login to get access

Abstract

Purpose

Various researchers have observed small areas of osteolysis after using bioabsorbable anchors in shoulder surgeries. The purpose of this study is to determine whether radiographic perianchor radiolucent rings after rotator cuff repair are associated with the failure of repair and also assess their clinical implications. Further, the most frequent location of the radiolucent rings in the double-row suture bridge configuration was also assessed.

Methods

One hundred and twenty-nine consecutive patients who underwent arthroscopic rotator cuff repair by suture bridge technique were retrospectively evaluated radiographically and clinically. The number and size of the rings that appeared at each follow-up were recorded. Also, the locations of each ring were recorded as anterior, middle or posterior, and medial or lateral according to the construct of the anchors used for suture bridge technique. The size of the tear, the number of anchors used and age of the patients were compared. Re-tear rates according to ultrasound examinations were also analyzed.

Results

After rotator cuff repair, the mean American Shoulder and Elbow Surgeons (ASES) score increased from 46.7 to 88.0 and the overall re-tear rate was 8.5% (11 cases). Seventy-three patients (56.6%) showed RR (total number of 99 rings) at least once during the course of their follow-up and the rings appeared at a mean period of 18.2 months after surgery. Mean size of the rings initially was 5.6 mm and the rings increased or decreased in mean size of 0.4 mm during mean follow-up of 37 months. No correlation was seen with the number of RRs and the rate of re-tears, number of anchors, size of tears, and clinical outcome as determined by the ASES score. Radiolucent ring measurement reproducibility was confirmed by independent, repeated measurements. The rings appeared mostly at anteromedial anchors (75 rings, 75.8%) and the authors suggest that mechanical factors may play a role for the cause of radiolucent rings.

Conclusions

The number and the size of RRs around bioabsorbable anchors after rotator cuff repair do not appear to adversely affect the healing and clinical outcome of ARCR. Most radiolucent rings appeared at anteromedial anchors, indicating that mechanical factors may play a role for the radiolucencies.

Level of evidence

Case series, level IV.
Literature
1.
go back to reference Athwal GS, Shridharani SM, O’Driscoll SW (2006) Osteolysis and arthropathy of the shoulder after use of bioabsorbable knotless suture anchors. A report of four cases. J Bone Jt Surg Am 88(8):1840–1845CrossRef Athwal GS, Shridharani SM, O’Driscoll SW (2006) Osteolysis and arthropathy of the shoulder after use of bioabsorbable knotless suture anchors. A report of four cases. J Bone Jt Surg Am 88(8):1840–1845CrossRef
2.
go back to reference Bishop J, Klepps S, Lo IK, Bird J, Gladstone JN, Flatow EL (2006) Cuff integrity after arthroscopic versus open rotator cuff repair: a prospective study. J Shoulder Elbow Surg 15(3):290–299CrossRefPubMed Bishop J, Klepps S, Lo IK, Bird J, Gladstone JN, Flatow EL (2006) Cuff integrity after arthroscopic versus open rotator cuff repair: a prospective study. J Shoulder Elbow Surg 15(3):290–299CrossRefPubMed
3.
go back to reference Bostman OM, Pihlajamaki HK (2000) Adverse tissue reactions to bioabsorbable fixation devices. Clin Orthop Relat Res 371:216–227CrossRef Bostman OM, Pihlajamaki HK (2000) Adverse tissue reactions to bioabsorbable fixation devices. Clin Orthop Relat Res 371:216–227CrossRef
4.
go back to reference Burkart A, Imhoff AB, Roscher E (2000) Foreign-body reaction to the bioabsorbable suretac device. Arthroscopy 16(1):91–95CrossRefPubMed Burkart A, Imhoff AB, Roscher E (2000) Foreign-body reaction to the bioabsorbable suretac device. Arthroscopy 16(1):91–95CrossRefPubMed
5.
go back to reference Burkhart SS (2005) Letter to the editor. Am J Sports Med 33:11 Burkhart SS (2005) Letter to the editor. Am J Sports Med 33:11
6.
go back to reference Burkhart SS, Denard PJ, Konicek J, Hanypsiak BT (2014) Biomechanical validation of load-sharing rip-stop fixation for the repair of tissue-deficient rotator cuff tears. Am J Sports Med 42(2):457–462CrossRefPubMed Burkhart SS, Denard PJ, Konicek J, Hanypsiak BT (2014) Biomechanical validation of load-sharing rip-stop fixation for the repair of tissue-deficient rotator cuff tears. Am J Sports Med 42(2):457–462CrossRefPubMed
7.
go back to reference Costello MF, Shrestha SM, Sjoblom P et al (2006) Power doppler ultrasound assessment of the relationship between age and ovarian perifollicular blood flow in women undergoing in vitro fertilization treatment. J Assist Reprod Genet 23(9–10):359–365CrossRefPubMedPubMedCentral Costello MF, Shrestha SM, Sjoblom P et al (2006) Power doppler ultrasound assessment of the relationship between age and ovarian perifollicular blood flow in women undergoing in vitro fertilization treatment. J Assist Reprod Genet 23(9–10):359–365CrossRefPubMedPubMedCentral
8.
go back to reference Dhawan A, Ghodadra N, Karas V, Salata MJ, Cole BJ (2011) Complications of bioabsorbable suture anchors in the shoulder. Am J Sports Med 40(6):1424–1430CrossRefPubMed Dhawan A, Ghodadra N, Karas V, Salata MJ, Cole BJ (2011) Complications of bioabsorbable suture anchors in the shoulder. Am J Sports Med 40(6):1424–1430CrossRefPubMed
9.
go back to reference Ejerhed L, Kartus J, Funck E, Kohler K, Sernert N, Karlsson J (2000) A clinical and radiographic comparison of absorbable and non-absorbable suture anchors in open shoulder stabilisation. Knee Surg Sports Traumatol Arthrosc 8(6):349–355CrossRefPubMed Ejerhed L, Kartus J, Funck E, Kohler K, Sernert N, Karlsson J (2000) A clinical and radiographic comparison of absorbable and non-absorbable suture anchors in open shoulder stabilisation. Knee Surg Sports Traumatol Arthrosc 8(6):349–355CrossRefPubMed
10.
go back to reference Freehill MQ, Harms DJ, Huber SM, Atlihan D, Buss DD (2003) Poly-l-lactic acid tack synovitis after arthroscopic stabilization of the shoulder. Am J Sports Med 31(5):643–647CrossRefPubMed Freehill MQ, Harms DJ, Huber SM, Atlihan D, Buss DD (2003) Poly-l-lactic acid tack synovitis after arthroscopic stabilization of the shoulder. Am J Sports Med 31(5):643–647CrossRefPubMed
11.
go back to reference Fuchs B, Gilbart MK, Hodler J, Gerber C (2006) Clinical and structural results of open repair of an isolated one-tendon tear of the rotator cuff. J Bone Jt Surg Am 88(2):309–316 Fuchs B, Gilbart MK, Hodler J, Gerber C (2006) Clinical and structural results of open repair of an isolated one-tendon tear of the rotator cuff. J Bone Jt Surg Am 88(2):309–316
12.
go back to reference Galatz LM, Ball CM, Teefey SA, Middleton WD, Yamaguchi K (2004) The outcome and repair integrity of completely arthroscopically repaired large and massive rotator cuff tears. J Bone Jt Surg Am 86-A(2):219–224CrossRef Galatz LM, Ball CM, Teefey SA, Middleton WD, Yamaguchi K (2004) The outcome and repair integrity of completely arthroscopically repaired large and massive rotator cuff tears. J Bone Jt Surg Am 86-A(2):219–224CrossRef
13.
go back to reference Glueck D, Wilson TC, Johnson DL (2005) Extensive osteolysis after rotator cuff repair with a bioabsorbable suture anchor: a case report. Am J Sports Med 33(5):742–744CrossRefPubMed Glueck D, Wilson TC, Johnson DL (2005) Extensive osteolysis after rotator cuff repair with a bioabsorbable suture anchor: a case report. Am J Sports Med 33(5):742–744CrossRefPubMed
14.
go back to reference Goradia VK, Mullen DJ, Boucher HR, Parks BG, O’Donnell JB (2001) Cyclic loading of rotator cuff repairs: a comparison of bioabsorbable tacks with metal suture anchors and transosseous sutures. Arthroscopy 17(4):360–364CrossRefPubMed Goradia VK, Mullen DJ, Boucher HR, Parks BG, O’Donnell JB (2001) Cyclic loading of rotator cuff repairs: a comparison of bioabsorbable tacks with metal suture anchors and transosseous sutures. Arthroscopy 17(4):360–364CrossRefPubMed
15.
go back to reference Gunja NJ, Athanasiou KA (2006) Biodegradable materials in arthroscopy. Sports Med Arthrosc 14(3):112–119CrossRefPubMed Gunja NJ, Athanasiou KA (2006) Biodegradable materials in arthroscopy. Sports Med Arthrosc 14(3):112–119CrossRefPubMed
16.
go back to reference Howe C, Huber P, Wolf FM, Matsen F 3rd (2009) Differential suture loading in an experimental rotator cuff repair. Am J Sports Med 37(2):324–329CrossRefPubMed Howe C, Huber P, Wolf FM, Matsen F 3rd (2009) Differential suture loading in an experimental rotator cuff repair. Am J Sports Med 37(2):324–329CrossRefPubMed
17.
go back to reference Jost B, Zumstein M, Pfirrmann CW, Gerber C (2006) Long-term outcome after structural failure of rotator cuff repairs. J Bone Jt Surg Am 88(3):472–479 Jost B, Zumstein M, Pfirrmann CW, Gerber C (2006) Long-term outcome after structural failure of rotator cuff repairs. J Bone Jt Surg Am 88(3):472–479
18.
go back to reference Kaplan K, Elattrache NS, Vazquez O, Chen YJ, Lee T (2011) Knotless rotator cuff repair in an external rotation model: the importance of medial-row horizontal mattress sutures. Arthroscopy 27(4):471–478CrossRefPubMed Kaplan K, Elattrache NS, Vazquez O, Chen YJ, Lee T (2011) Knotless rotator cuff repair in an external rotation model: the importance of medial-row horizontal mattress sutures. Arthroscopy 27(4):471–478CrossRefPubMed
19.
go back to reference Kartus J, Ejerhed L, Funck E, Kohler K, Sernert N, Karlsson J (1998) Arthroscopic and open shoulder stabilization using absorbable implants. A clinical and radiographic comparison of two methods. Knee Surg Sports Traumatol Arthrosc 6(3):181–188CrossRefPubMed Kartus J, Ejerhed L, Funck E, Kohler K, Sernert N, Karlsson J (1998) Arthroscopic and open shoulder stabilization using absorbable implants. A clinical and radiographic comparison of two methods. Knee Surg Sports Traumatol Arthrosc 6(3):181–188CrossRefPubMed
20.
go back to reference McFarland EG, Park HB, Keyurapan E, Gill HS, Selhi HS (2005) Suture anchors and tacks for shoulder surgery, part 1: biology and biomechanics. Am J Sports Med 33(12):1918–1923CrossRefPubMed McFarland EG, Park HB, Keyurapan E, Gill HS, Selhi HS (2005) Suture anchors and tacks for shoulder surgery, part 1: biology and biomechanics. Am J Sports Med 33(12):1918–1923CrossRefPubMed
21.
go back to reference McNally EG (2011) The development and clinical applications of musculoskeletal ultrasound. Skelet Radiol 40(9):1223–1231CrossRef McNally EG (2011) The development and clinical applications of musculoskeletal ultrasound. Skelet Radiol 40(9):1223–1231CrossRef
22.
go back to reference Muller M, Kaab MJ, Villiger C, Holzach P (2002) Osteolysis after open shoulder stabilization using a new bio-resorbable bone anchor: a prospective, non-randomized clinical trial. Injury 33(Suppl 2):B30–B36CrossRefPubMed Muller M, Kaab MJ, Villiger C, Holzach P (2002) Osteolysis after open shoulder stabilization using a new bio-resorbable bone anchor: a prospective, non-randomized clinical trial. Injury 33(Suppl 2):B30–B36CrossRefPubMed
23.
go back to reference Nho SJ, Provencher MT, Seroyer ST, Romeo AA (2009) Bioabsorbable anchors in glenohumeral shoulder surgery. Arthroscopy 25(7):788–793CrossRefPubMed Nho SJ, Provencher MT, Seroyer ST, Romeo AA (2009) Bioabsorbable anchors in glenohumeral shoulder surgery. Arthroscopy 25(7):788–793CrossRefPubMed
24.
go back to reference Nusselt T, Freche S, Klinger HM, Baums MH (2010) Intraosseous foreign body granuloma in rotator cuff repair with bioabsorbable suture anchor. Arch Orthop Trauma Surg 130(8):1037–1040CrossRefPubMedPubMedCentral Nusselt T, Freche S, Klinger HM, Baums MH (2010) Intraosseous foreign body granuloma in rotator cuff repair with bioabsorbable suture anchor. Arch Orthop Trauma Surg 130(8):1037–1040CrossRefPubMedPubMedCentral
25.
go back to reference Pilge H, Spang J, Rose T, Wolter H, Woertler K, Imhoff AB (2011) Osteolysis after rotator cuff repair with bioabsorbable anchors. Arch Orthop Trauma Surg 132(3):305–310CrossRefPubMed Pilge H, Spang J, Rose T, Wolter H, Woertler K, Imhoff AB (2011) Osteolysis after rotator cuff repair with bioabsorbable anchors. Arch Orthop Trauma Surg 132(3):305–310CrossRefPubMed
26.
go back to reference Spoliti M (2007) Glenoid osteolysis after arthroscopic labrum repair with a bioabsorbable suture anchor. Acta Orthop Belg 73(1):107–110PubMed Spoliti M (2007) Glenoid osteolysis after arthroscopic labrum repair with a bioabsorbable suture anchor. Acta Orthop Belg 73(1):107–110PubMed
27.
go back to reference Tanaka M, Hayashida K, Kobayashi A, Kakiuchi M (2015) Arthroscopic rotator cuff repair with absorbable sutures in the medial-row anchors. Arthroscopy 31(11):2099–2105CrossRefPubMed Tanaka M, Hayashida K, Kobayashi A, Kakiuchi M (2015) Arthroscopic rotator cuff repair with absorbable sutures in the medial-row anchors. Arthroscopy 31(11):2099–2105CrossRefPubMed
28.
go back to reference Thorsness R, Romeo A (2016) Massive rotator cuff tears: trends in surgical management. Orthopedics 39(3):145–151CrossRefPubMed Thorsness R, Romeo A (2016) Massive rotator cuff tears: trends in surgical management. Orthopedics 39(3):145–151CrossRefPubMed
29.
go back to reference Warme WJ, Arciero RA, Savoie FH 3rd, Uhorchak JM, Walton M (1999) Nonabsorbable versus absorbable suture anchors for open Bankart repair. A prospective, randomized comparison. Am J Sports Med 27(6):742–746CrossRefPubMed Warme WJ, Arciero RA, Savoie FH 3rd, Uhorchak JM, Walton M (1999) Nonabsorbable versus absorbable suture anchors for open Bankart repair. A prospective, randomized comparison. Am J Sports Med 27(6):742–746CrossRefPubMed
30.
go back to reference Yen CH, Chiou HJ, Chou YH et al (2004) Six surgery-correlated sonographic signs for rotator cuff tears: emphasis on partial-thickness tear. Clin Imaging 28(1):69–76CrossRefPubMed Yen CH, Chiou HJ, Chou YH et al (2004) Six surgery-correlated sonographic signs for rotator cuff tears: emphasis on partial-thickness tear. Clin Imaging 28(1):69–76CrossRefPubMed
Metadata
Title
Radiolucent rings around bioabsorbable anchors after rotator cuff repair are not associated with clinical outcomes
Authors
Jin-Young Park
Suk-Hwan Jang
Kyung-Soo Oh
Yi Jin Li
Publication date
01-11-2017
Publisher
Springer Berlin Heidelberg
Published in
Archives of Orthopaedic and Trauma Surgery / Issue 11/2017
Print ISSN: 0936-8051
Electronic ISSN: 1434-3916
DOI
https://doi.org/10.1007/s00402-017-2772-1

Other articles of this Issue 11/2017

Archives of Orthopaedic and Trauma Surgery 11/2017 Go to the issue

Abstracts

Abstracts