Skip to main content
Top
Published in: Archives of Orthopaedic and Trauma Surgery 8/2010

Open Access 01-08-2010 | Arthroscopy and Sports Medicine

Intraosseous foreign body granuloma in rotator cuff repair with bioabsorbable suture anchor

Authors: T. Nusselt, S. Freche, H.-M. Klinger, M. H. Baums

Published in: Archives of Orthopaedic and Trauma Surgery | Issue 8/2010

Login to get access

Abstract

Biodegradable implants lead to problems such as cyst formation, soft-tissue inflammation, loose implant fragments or local osteolysis. This report represents the first published case of an intraosseous foreign body granuloma in the humeral head after arthroscopic rotator cuff tear fixation with a poly-l-lactide (PLLA) suture anchor. A 48-year-old female patient presented with pain in her right shoulder. A refixation of her right supraspinatus tendon with a biodegradable suture anchor was performed 11 months ago at an external hospital. Laboratory tests showed normal values for C-reactive protein, leukocytes and the erythrocyte sedimentation rate. No signs of infection or instability were noted. The visual analogue scale (VAS) was 8, the simple shoulder test (SST) was 4 and the American shoulder and elbow surgeons score (ASES) was 44. Plain radiographs showed high lucency in the area of the tuberculum majus. MRI showed an intra- and extraosseous mass surrounded by fluid in this area. Surgical care involved arthroscopic debridement and removal of the suture anchor. Histological examination revealed a foreign body granuloma. At the 18-month follow-up the patient was nearly pain-free. The VAS was 2, SST was 10 and ASES was 88. Foreign body granulomas are a well known but rarely described complication that arises after the use of biodegradable suture anchors in shoulder surgery. Every patient presenting with shoulder pain after usage of a biodegradable fixation material should be evaluated closely. Orthopaedic surgeons should be aware of the possibility of delayed foreign body reactions, especially after using PLLA anchors.
Literature
1.
go back to reference Scheibel MT, Habermeyer P (2003) A modified Mason-Allen technique for rotator cuff repair using suture anchors. Arthroscopy 19:330–333CrossRefPubMed Scheibel MT, Habermeyer P (2003) A modified Mason-Allen technique for rotator cuff repair using suture anchors. Arthroscopy 19:330–333CrossRefPubMed
2.
go back to reference Spoliti M (2007) Glenoid osteolysis after arthroscopic labrum repair with a bioabsorbable suture anchor. Acta Orthop Belg 73:107–1010PubMed Spoliti M (2007) Glenoid osteolysis after arthroscopic labrum repair with a bioabsorbable suture anchor. Acta Orthop Belg 73:107–1010PubMed
3.
go back to reference Klinger HM, Buchhorn GH, Heidrich G, Kahl E, Baums MH (2008) Biomechanical evaluation of rotator cuff repairs in a sheep model: suture anchors using arthroscopic Mason-Allen stitches compared with transosseous sutures using traditional modified Mason-Allen stitches. Clin Biomech 23:291–298CrossRef Klinger HM, Buchhorn GH, Heidrich G, Kahl E, Baums MH (2008) Biomechanical evaluation of rotator cuff repairs in a sheep model: suture anchors using arthroscopic Mason-Allen stitches compared with transosseous sutures using traditional modified Mason-Allen stitches. Clin Biomech 23:291–298CrossRef
4.
go back to reference McFarland EG, Park HB, Keyurapan E, Gill HS, Selhi S (2005) Suture anchors and tacks for shoulder surgery, part 1. Am J Sports Med 33:1918–1923CrossRefPubMed McFarland EG, Park HB, Keyurapan E, Gill HS, Selhi S (2005) Suture anchors and tacks for shoulder surgery, part 1. Am J Sports Med 33:1918–1923CrossRefPubMed
5.
go back to reference Goradia VK, Mullen DJ, Boucher HR, Parks BG, O’Donnell JB (2001) Cyclic loading of rotator cuff repairs: a comparison of bioabsorbable tacks with metal suture anchors and transosseous sutures. Arthroscopy 17:360–364CrossRefPubMed Goradia VK, Mullen DJ, Boucher HR, Parks BG, O’Donnell JB (2001) Cyclic loading of rotator cuff repairs: a comparison of bioabsorbable tacks with metal suture anchors and transosseous sutures. Arthroscopy 17:360–364CrossRefPubMed
7.
go back to reference McGuire DA, Barber FA, Elrod BF, Paulos LE (1999) Bioabsorbable interference screws for graft fixation in anterior cruciate ligament reconstruction. Arthroscopy 15:463–473CrossRefPubMed McGuire DA, Barber FA, Elrod BF, Paulos LE (1999) Bioabsorbable interference screws for graft fixation in anterior cruciate ligament reconstruction. Arthroscopy 15:463–473CrossRefPubMed
8.
go back to reference Weiler A, Windhagen HJ, Raschke MJ, Laumeyer A, Hoffmann RF (1998) Biodegradable interference screw fixation exhibits pull-out force and stiffness similar to titanium screws. Am J Sports Med 26:119–127CrossRefPubMed Weiler A, Windhagen HJ, Raschke MJ, Laumeyer A, Hoffmann RF (1998) Biodegradable interference screw fixation exhibits pull-out force and stiffness similar to titanium screws. Am J Sports Med 26:119–127CrossRefPubMed
9.
go back to reference Böstman OM (1991) Current concepts review: absorbable implants for the fixation of fractures. J Bone Joint Surg 73-A:148–153 Böstman OM (1991) Current concepts review: absorbable implants for the fixation of fractures. J Bone Joint Surg 73-A:148–153
10.
go back to reference Böstman O, Päivärinta U, Partio E, Vasenius J, Manninen M, Rokkanen P (1992) Degradation and tissue replacement of an absorbable polyglycolide screw in the fixation of rabbit femoral osteotomies. J Bone Joint Surg 74-A:1021–1031 Böstman O, Päivärinta U, Partio E, Vasenius J, Manninen M, Rokkanen P (1992) Degradation and tissue replacement of an absorbable polyglycolide screw in the fixation of rabbit femoral osteotomies. J Bone Joint Surg 74-A:1021–1031
11.
go back to reference Bergsma EJ, de Bruijn WC, Rozema FR, Bos RRM, Boering G (1995) Late degradation tissue response to poly(l-lactide) bone plates and screws. Biomaterials 16:25–31CrossRefPubMed Bergsma EJ, de Bruijn WC, Rozema FR, Bos RRM, Boering G (1995) Late degradation tissue response to poly(l-lactide) bone plates and screws. Biomaterials 16:25–31CrossRefPubMed
12.
go back to reference Suuronen R, Pohjonen T, Hietanen J, Lindqvist C (1998) A 5-year in vitro and in vivo study of the biodegradation of polylactide plates. J Oral Maxillofac Surg 56:604–614CrossRefPubMed Suuronen R, Pohjonen T, Hietanen J, Lindqvist C (1998) A 5-year in vitro and in vivo study of the biodegradation of polylactide plates. J Oral Maxillofac Surg 56:604–614CrossRefPubMed
13.
go back to reference Böstman OM, Pihlajamaki HK (2000) Adverse tissue reactions to bioabsorbable fixation devices. Clin Orthop Rel Res 371:216–227CrossRef Böstman OM, Pihlajamaki HK (2000) Adverse tissue reactions to bioabsorbable fixation devices. Clin Orthop Rel Res 371:216–227CrossRef
14.
go back to reference Freehill MQ, Harms DJ, Huber SM, Atlihan D, Buss DD (2003) Poly-l-lactic acid tack synovitis after arthroscopic stabilization of the shoulder. Am J Sports Med 31:643–647PubMed Freehill MQ, Harms DJ, Huber SM, Atlihan D, Buss DD (2003) Poly-l-lactic acid tack synovitis after arthroscopic stabilization of the shoulder. Am J Sports Med 31:643–647PubMed
15.
go back to reference Peltoniemi H, Ashammakhi N, Kontio R, Waris T, Salo A, Lindqvist C, Grätz K, Suuronen R (2002) The use of bioabsorbable osteofixation devices in craniomaxillofacial surgery. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 94:5–14CrossRefPubMed Peltoniemi H, Ashammakhi N, Kontio R, Waris T, Salo A, Lindqvist C, Grätz K, Suuronen R (2002) The use of bioabsorbable osteofixation devices in craniomaxillofacial surgery. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 94:5–14CrossRefPubMed
16.
go back to reference Glueck D, Wilson TC, Johnson DL (2005) Extensive osteolysis after rotator cuff repair with a bioabsorbable suture anchor. Am J Sports Med 33:742–744CrossRefPubMed Glueck D, Wilson TC, Johnson DL (2005) Extensive osteolysis after rotator cuff repair with a bioabsorbable suture anchor. Am J Sports Med 33:742–744CrossRefPubMed
17.
go back to reference Müller M, Kääb MJ, Villiger C, Holzach P (2002) Osteolysis after open shoulder stabilization using a new bio-resorbable bone anchor: a prospective, non-randomized clinical trial. Injury 33:30–36CrossRef Müller M, Kääb MJ, Villiger C, Holzach P (2002) Osteolysis after open shoulder stabilization using a new bio-resorbable bone anchor: a prospective, non-randomized clinical trial. Injury 33:30–36CrossRef
18.
go back to reference Athwal GS, Shridharani SM, O’Driscoll SW (2006) Osteolysis and arthropathy of the shoulder after use of bioabsorbable knotless suture anchors. J Bone Joint Surg Am 88:1840–1845CrossRefPubMed Athwal GS, Shridharani SM, O’Driscoll SW (2006) Osteolysis and arthropathy of the shoulder after use of bioabsorbable knotless suture anchors. J Bone Joint Surg Am 88:1840–1845CrossRefPubMed
19.
go back to reference Benedetto KP, Fellinger M, Lim TE, Passler JM, Schoen JL, Willems WJ (2000) A new bioabsorbable interference screw: preliminary results of a prospective, multicenter, randomized clinical trial. Arthroscopy 16:41–48CrossRefPubMed Benedetto KP, Fellinger M, Lim TE, Passler JM, Schoen JL, Willems WJ (2000) A new bioabsorbable interference screw: preliminary results of a prospective, multicenter, randomized clinical trial. Arthroscopy 16:41–48CrossRefPubMed
20.
go back to reference Barber FA, Snyder SJ, Abrams JS, Fanelli GC, Savoie FH 3rd (2003) Arthroscopic Bankart reconstruction with a bioabsorbable anchor. J Shoulder Elbow Surg 12:535–538CrossRefPubMed Barber FA, Snyder SJ, Abrams JS, Fanelli GC, Savoie FH 3rd (2003) Arthroscopic Bankart reconstruction with a bioabsorbable anchor. J Shoulder Elbow Surg 12:535–538CrossRefPubMed
21.
go back to reference Warme WJ, Arciero RA, Savoie FH 3rd, Uhorchak JM, Walton M (1999) Nonabsorbable versus absorbable suture anchors for open Bankart repair. A prospective, randomized comparison. Am J Sports Med 27:742–746PubMed Warme WJ, Arciero RA, Savoie FH 3rd, Uhorchak JM, Walton M (1999) Nonabsorbable versus absorbable suture anchors for open Bankart repair. A prospective, randomized comparison. Am J Sports Med 27:742–746PubMed
22.
go back to reference Böstman OM, Pihlajamäki HK (1998) Late foreign-body reaction to an intraosseous bioabsorbable polylactic acid screw. A case report. J Bone Joint Surg 80:1791–1794CrossRefPubMed Böstman OM, Pihlajamäki HK (1998) Late foreign-body reaction to an intraosseous bioabsorbable polylactic acid screw. A case report. J Bone Joint Surg 80:1791–1794CrossRefPubMed
23.
go back to reference Meyer DC, Gerber C (2004) Failure of anterior shoulder instability repair caused by eyelet cutout of absorbable suture anchors. Arthroscopy 20:521–523CrossRefPubMed Meyer DC, Gerber C (2004) Failure of anterior shoulder instability repair caused by eyelet cutout of absorbable suture anchors. Arthroscopy 20:521–523CrossRefPubMed
24.
go back to reference Pihlajamäki H, Böstman O, Hirvensalo E, Tömälä P, Rokkanen P (1992) Absorbable pins of self-reinforced poly-l-lactic acid for fixation of fractures and osteotomies. J Bone Joint Surg 74:853–857 Pihlajamäki H, Böstman O, Hirvensalo E, Tömälä P, Rokkanen P (1992) Absorbable pins of self-reinforced poly-l-lactic acid for fixation of fractures and osteotomies. J Bone Joint Surg 74:853–857
25.
go back to reference Matsusue Y, Hanafusa S, Yamamuro T, Shikinami Y, Ikada Y (1995) Tissue reaction of bioabsorbable ultra high strength poly (l-lactide) rod. A long-term study in rabbits. Clin Orthop 317:246–253PubMed Matsusue Y, Hanafusa S, Yamamuro T, Shikinami Y, Ikada Y (1995) Tissue reaction of bioabsorbable ultra high strength poly (l-lactide) rod. A long-term study in rabbits. Clin Orthop 317:246–253PubMed
26.
go back to reference Rokkanen PU, Böstman O, Hirvensalo E, Mäkelä EA, Partio EK, Pätiälä H, Vainionpää SI, Vihtonen K, Törmälä P (2000) Bioabsorbable fixation in orthopaedic surgery and traumatology. Biomaterials 21:2607–2613CrossRefPubMed Rokkanen PU, Böstman O, Hirvensalo E, Mäkelä EA, Partio EK, Pätiälä H, Vainionpää SI, Vihtonen K, Törmälä P (2000) Bioabsorbable fixation in orthopaedic surgery and traumatology. Biomaterials 21:2607–2613CrossRefPubMed
27.
go back to reference Kääb MJ, Rahn BA, Weiler A, Curtis R, Perren SM, Schneider E (2002) Osseous integration of poly-(l-co-d/l-lactide) 70/30 and titanium suture anchors: an experimental study in sheep cancellous bone. Injury 33:B37–B42CrossRefPubMed Kääb MJ, Rahn BA, Weiler A, Curtis R, Perren SM, Schneider E (2002) Osseous integration of poly-(l-co-d/l-lactide) 70/30 and titanium suture anchors: an experimental study in sheep cancellous bone. Injury 33:B37–B42CrossRefPubMed
28.
go back to reference Lohrbach O, Wilmes P, Brogard P, Seil R (2008) Complications related to implants in arthroscopic shoulder surgery [German]. Orthopäde 37:1073–1079CrossRef Lohrbach O, Wilmes P, Brogard P, Seil R (2008) Complications related to implants in arthroscopic shoulder surgery [German]. Orthopäde 37:1073–1079CrossRef
Metadata
Title
Intraosseous foreign body granuloma in rotator cuff repair with bioabsorbable suture anchor
Authors
T. Nusselt
S. Freche
H.-M. Klinger
M. H. Baums
Publication date
01-08-2010
Publisher
Springer-Verlag
Published in
Archives of Orthopaedic and Trauma Surgery / Issue 8/2010
Print ISSN: 0936-8051
Electronic ISSN: 1434-3916
DOI
https://doi.org/10.1007/s00402-010-1125-0

Other articles of this Issue 8/2010

Archives of Orthopaedic and Trauma Surgery 8/2010 Go to the issue