Abstract

Purpose

This retrospective study was performed to determine the effectiveness of preventing recurrent dislocation following primary cemented Endo-MarkIII/SP2 total hip replacement using a posterior lip augmentation device (PLAD).

Methods

Between January 2003 and Dezember 2006, 27 PLADs were used in the treatment of recurrent hip dislocation in 27 patients who had received a cemented primary total hip arthroplasty using Endo-MarkIII/SP2 (Waldemar LINK, Hamburg, Germany) components. The mean number of dislocations prior to stabilization with this specific device was 2.6 (range 2–4, SD ± 0.4) with a mean time to revision surgery of 10 months (IQR 13). The mean age of the patients at time of revision surgery was 81.5 years (range 70–94, SD ± 6.9). The control group evaluating the clinical outcome using the Harris Hip Score (HHS) also received a cemented primary total hip arthroplasty using the same implants. A retrospective clinical and radiological review was carried out at a mean follow-up of 68.5 months (range 30–103, SD ± 17.7).

Results

Of the 27 patients, 6 had died at the time of the latest review, with the posterior lip augmentation device still in situ and without reported further dislocation after PLAD application. In 2 of the remaining 21 patients recurrent dislocation occurred, thus a subsequent revision of respective implants had to be performed to achieve persistent joint stability. At latest follow-up no deep infection or implant loosening occurred.

Conclusion

Surgical treatment of recurrent dislocation following primary cemented Endo-MarkIII/SP2 total hip replacement using a posterior lip augmentation device is a safe and effective procedure which can lead to a secondary stabilization of the total hip arthroplasty in about 90 % of the patients.
Literature
1.
go back to reference Masonis JL, Bourne RB (2002) Surgical approach, abductor function, and total hip arthroplasty dislocation. Clin Orthop 405:46–53CrossRefPubMed Masonis JL, Bourne RB (2002) Surgical approach, abductor function, and total hip arthroplasty dislocation. Clin Orthop 405:46–53CrossRefPubMed
2.
go back to reference Woo YG, Morrey BF (1982) Dislocations after total hip arthroplasty. J Bone Joint Surg (Am) 64(9):1295–1306 Woo YG, Morrey BF (1982) Dislocations after total hip arthroplasty. J Bone Joint Surg (Am) 64(9):1295–1306
3.
go back to reference Turner RS (1994) Postoperative total hip prosthetic femoral head dislocations. Clin Orthop 301:196–204PubMed Turner RS (1994) Postoperative total hip prosthetic femoral head dislocations. Clin Orthop 301:196–204PubMed
4.
go back to reference Joshi A, Lee CM, Markovic L, Vlatis G, Murphy JCM (1998) Prognosis of dislocation after total hip arthroplasty. J Arthroplasty 13:17–21CrossRefPubMed Joshi A, Lee CM, Markovic L, Vlatis G, Murphy JCM (1998) Prognosis of dislocation after total hip arthroplasty. J Arthroplasty 13:17–21CrossRefPubMed
5.
go back to reference Bozic KJ, Kurtz SM, Lau E, Ong K, Vail TP, Berry DJ (2009) The epidemiology of revision total hip arthroplasty in the United States. J Bone Joint Surg Am 91(1):128–133CrossRefPubMed Bozic KJ, Kurtz SM, Lau E, Ong K, Vail TP, Berry DJ (2009) The epidemiology of revision total hip arthroplasty in the United States. J Bone Joint Surg Am 91(1):128–133CrossRefPubMed
6.
go back to reference Barrack RL (2003) Dislocation after total hip arthroplasty: implant design and orientation. J Am Acad Orthop Surg 11(2):89–99CrossRefPubMed Barrack RL (2003) Dislocation after total hip arthroplasty: implant design and orientation. J Am Acad Orthop Surg 11(2):89–99CrossRefPubMed
7.
go back to reference Katz JN, Losina E, Barrett J, Phillips CB, Mahomed NN, Lew RA, Guadagnoli E, Harris WH, Poss R, Baron JA (2001) Association between hospital and surgeon procedure volume and outcomes of total hip replacement in the United States medicare population. J Bone Joint Surg Am 83-A(11):1622–1629PubMed Katz JN, Losina E, Barrett J, Phillips CB, Mahomed NN, Lew RA, Guadagnoli E, Harris WH, Poss R, Baron JA (2001) Association between hospital and surgeon procedure volume and outcomes of total hip replacement in the United States medicare population. J Bone Joint Surg Am 83-A(11):1622–1629PubMed
8.
go back to reference Wera GD, Ting NT, Moric M, Paprosky WG, Sporer SM, Della Valle CJ (2012) Classification and management of the unstable total hip arthroplasty. J Arthroplasty 27(5):710–715CrossRefPubMed Wera GD, Ting NT, Moric M, Paprosky WG, Sporer SM, Della Valle CJ (2012) Classification and management of the unstable total hip arthroplasty. J Arthroplasty 27(5):710–715CrossRefPubMed
9.
go back to reference Gholve PA, Lovell ME, Naqui SZ (2006) Minimal surgical approach for recurrent hip dislocation using the posterior lip augmentation device for the Charnley hip arthroplasty. J Arthroplasty 21(6):865–868CrossRefPubMed Gholve PA, Lovell ME, Naqui SZ (2006) Minimal surgical approach for recurrent hip dislocation using the posterior lip augmentation device for the Charnley hip arthroplasty. J Arthroplasty 21(6):865–868CrossRefPubMed
10.
go back to reference Paterno SA, Lachiewicz PF, Kelley SS (1997) The influence of patient-related factors and the position of the acetabular component on the rate of dislocation after total hip replacement. J Bone Joint Surg Am 79(8):1202–1210PubMed Paterno SA, Lachiewicz PF, Kelley SS (1997) The influence of patient-related factors and the position of the acetabular component on the rate of dislocation after total hip replacement. J Bone Joint Surg Am 79(8):1202–1210PubMed
11.
go back to reference Charissoux JL, Asloum Y, Marcheix PS (2014) Surgical management of recurrent dislocation after total hip arthroplasty. Orthop Traumatol Surg Res. 100(1 Suppl):25–34CrossRef Charissoux JL, Asloum Y, Marcheix PS (2014) Surgical management of recurrent dislocation after total hip arthroplasty. Orthop Traumatol Surg Res. 100(1 Suppl):25–34CrossRef
12.
go back to reference Prokopetz JJ, Losina E, Bliss RL, Wright J, Baron JA, Katz JN (2012) Risk factors for revision of primary total hip arthroplasty: a systematic review. BMC 15(13):251 Prokopetz JJ, Losina E, Bliss RL, Wright J, Baron JA, Katz JN (2012) Risk factors for revision of primary total hip arthroplasty: a systematic review. BMC 15(13):251
13.
go back to reference Lewinnek GE, Lewis JL, Tarr R, Compere CL, Zimmerman JR (1978) Dislocations after total hip-replacement arthroplasties. J Bone Joint Surg Am 60(2):217–220PubMed Lewinnek GE, Lewis JL, Tarr R, Compere CL, Zimmerman JR (1978) Dislocations after total hip-replacement arthroplasties. J Bone Joint Surg Am 60(2):217–220PubMed
14.
go back to reference Lachiewicz PF, Soileau E, Ellis J (2004) Modular revision for recurrent dislocation of primary or revision total hip arthroplasty. J Arthroplasty 19:424–429CrossRefPubMed Lachiewicz PF, Soileau E, Ellis J (2004) Modular revision for recurrent dislocation of primary or revision total hip arthroplasty. J Arthroplasty 19:424–429CrossRefPubMed
15.
go back to reference Toomey SD, Hopper RH Jr, McAuley JP, Engh CA (2001) Modular component exchange for treatment of recurrent dislocation of a total hip replacement in selected patients. J Bone Joint Surg Am 83-A:1529–1533PubMed Toomey SD, Hopper RH Jr, McAuley JP, Engh CA (2001) Modular component exchange for treatment of recurrent dislocation of a total hip replacement in selected patients. J Bone Joint Surg Am 83-A:1529–1533PubMed
17.
go back to reference Wines AP, McNicol D (2006) Computed tomography measurement of the accuracy of component version in total hip arthroplasty. J Arthroplasty 21:696–701CrossRefPubMed Wines AP, McNicol D (2006) Computed tomography measurement of the accuracy of component version in total hip arthroplasty. J Arthroplasty 21:696–701CrossRefPubMed
18.
go back to reference McConway J, O’Brien S, Doran E, Archbold P, Beverland D (2007) The use of a posterior lip augmentation device for a revision of recurrent dislocation after primary cemented Charnley/Charnley Elite total hip replacement: results at a mean follow-up of six years and nine months. J Bone Joint Surg Br 89(12):1581–1585CrossRefPubMed McConway J, O’Brien S, Doran E, Archbold P, Beverland D (2007) The use of a posterior lip augmentation device for a revision of recurrent dislocation after primary cemented Charnley/Charnley Elite total hip replacement: results at a mean follow-up of six years and nine months. J Bone Joint Surg Br 89(12):1581–1585CrossRefPubMed
19.
go back to reference Cobb TK, Morrey BF, Ilstrup DM (1996) The elevated-rim acetabular liner in total hip arthroplasty: relationship to postoperative dislocation. J Bone Joint Surg (Am) 78(1):80–86 Cobb TK, Morrey BF, Ilstrup DM (1996) The elevated-rim acetabular liner in total hip arthroplasty: relationship to postoperative dislocation. J Bone Joint Surg (Am) 78(1):80–86
20.
go back to reference Cobb TK, Morrey BF, Ilstrup DM (1997) Effect of the elevated-rim acetabular liner on loosening after total hip arthroplasty. J Bone Joint Surg Am 79(9):1361–1364PubMed Cobb TK, Morrey BF, Ilstrup DM (1997) Effect of the elevated-rim acetabular liner on loosening after total hip arthroplasty. J Bone Joint Surg Am 79(9):1361–1364PubMed
21.
go back to reference Enocson AG, Minde J, Svensson O (2006) Socket wall addition device in the treatment of recurrent hip prosthesis dislocation: good outcome in 12 patients followed for 4.5 (1–9) years. Acta Orthop 77(1):87–91CrossRefPubMed Enocson AG, Minde J, Svensson O (2006) Socket wall addition device in the treatment of recurrent hip prosthesis dislocation: good outcome in 12 patients followed for 4.5 (1–9) years. Acta Orthop 77(1):87–91CrossRefPubMed
Metadata
Title
Effective prevention of recurrent dislocation following primary cemented Endo-MarkIII/SP2 total hip arthroplasty using a posterior lip augmentation device
Authors
S. Schmidl
O. Jakobs
D. Guenther
C. Lausmann
B. Schoof
J. Beckmann
T. Gehrke
M. Gebauer
Publication date
01-04-2016
Publisher
Springer Berlin Heidelberg
Published in
Archives of Orthopaedic and Trauma Surgery / Issue 4/2016
Print ISSN: 0936-8051
Electronic ISSN: 1434-3916
DOI
https://doi.org/10.1007/s00402-016-2415-y

Other articles of this Issue 4/2016

Archives of Orthopaedic and Trauma Surgery 4/2016 Go to the issue