Skip to main content
Top
Published in: Archives of Orthopaedic and Trauma Surgery 12/2011

01-12-2011 | Hip Arthroplasty

Is there an increased stem migration or compromised osteointegration of the Mayo™ short-stemmed prosthesis following cerclage wiring of an intrasurgical periprosthetic fracture?

Authors: Alexander Zeh, Florian Radetzki, Verena Diers, Dirk Bach, Marc Röllinghoff, Karl Stefan Delank

Published in: Archives of Orthopaedic and Trauma Surgery | Issue 12/2011

Login to get access

Abstract

Aim

Short-stemmed prostheses are increasingly regarded as implants of first choice in primary THA. As a result of the press-fit fixation in the femoral metaphysis, the occurrence of intraoperative fractures were reported. The aim of this study was to analyze the postoperative results of the Mayo™ short-stem prosthesis following treatment of an intrasurgical femur fracture with cerclage wiring.

Patients and methods

From 1999 to 2005, in 38 patients (18 females, 20 males; mean age 56 years; mean BMI = 27) with the diagnosis of coxarthrosis in whom a Mayo™ short-stemmed prosthesis has been implanted, an intraoperative fracture was observed. The fractures were treated with cerclage wiring (1 cerclage, n = 32; 2 cerclages, n = 5; 3 cerclages, n = 1). Postoperatively, all patients were prescribed mobilization without weight-bearing (floor contact) on the treated leg for 6 weeks. Using the Wristing© software, longitudinal stem migration and varus–valgus femoral stem alignment were examined digitally in anteroposterior X-rays taken immediately after surgery, after 6 weeks and on average after 5.7 years (Zeh et al., Z Orthop Unfall 149:200–205, 2011). Additionally, the incidence of periprosthetic radiolucent lines was captured in the anteroposterior X-rays and assigned to the Gruen zones. Additionally, a DEXA scan was performed. The X-rays of a matched control group after the implantation of a Mayo™ prosthesis without femur fracture were analyzed by the same method.

Results

There was no significant migration of the Mayo™ prosthesis in the study or control groups during postoperative follow-up (t test, P > 0.05). The cerclage group compared with the control group showed a statistically significant valgus tilt of 1.5° on average during the follow-up, which is regarded to be clinically not relevant. The frequency of occurrence of radiolucent lines was not statistically different (chi-square test, χ = 0.42, P = 0.51). DEXA scans showed no differences of the bone mineral density in the Gruen zones compared with a historical control group.

Conclusion

After wiring of an intrasurgical fracture, no disadvantage could be proven for Mayo™ prosthesis regarding stem migration and varus–valgus alignment. Furthermore, due to the absence of differences in the occurrence of radiolucent lines and the same results in the DEXA scan, an unimpaired osseointegration is assumed.
Literature
1.
go back to reference Chen HH, Morrey BF, An KN, Luo ZP (2009) Bone remodeling characteristics of a short-stemmed total hip replacement. J Arthroplasty 24:945–950PubMedCrossRef Chen HH, Morrey BF, An KN, Luo ZP (2009) Bone remodeling characteristics of a short-stemmed total hip replacement. J Arthroplasty 24:945–950PubMedCrossRef
2.
go back to reference Falez F, Casella F, Panegrossi G, Favetti F, Barresi C (2008) Perspectives on metaphyseal conservative stems. J Orthop Traumatol 9:49–54PubMedCrossRef Falez F, Casella F, Panegrossi G, Favetti F, Barresi C (2008) Perspectives on metaphyseal conservative stems. J Orthop Traumatol 9:49–54PubMedCrossRef
3.
go back to reference Fottner A, Schmid M, Birkenmaier C, Mazoochian F, Plitz W, Volkmar J (2009) Biomechanical evaluation of two types of short-stemmed hip prostheses compared to the trust plate prosthesis by three-dimensional measurement of micromotions. Clin Biomech (Bristol Avon) 24:429–434CrossRef Fottner A, Schmid M, Birkenmaier C, Mazoochian F, Plitz W, Volkmar J (2009) Biomechanical evaluation of two types of short-stemmed hip prostheses compared to the trust plate prosthesis by three-dimensional measurement of micromotions. Clin Biomech (Bristol Avon) 24:429–434CrossRef
4.
go back to reference Ghera S, Pavan L (2009) The DePuy Proxima hip: a short stem for total hip arthroplasty. Early experience and technical considerations. Hip Int 19:215–220PubMed Ghera S, Pavan L (2009) The DePuy Proxima hip: a short stem for total hip arthroplasty. Early experience and technical considerations. Hip Int 19:215–220PubMed
5.
go back to reference Gilbert RE, Salehi-Bird S, Gallacher PD, Shaylor P (2009) The Mayo Conservative Hip: experience from a district general hospital. Hip Int 19:211–214PubMed Gilbert RE, Salehi-Bird S, Gallacher PD, Shaylor P (2009) The Mayo Conservative Hip: experience from a district general hospital. Hip Int 19:211–214PubMed
6.
go back to reference Gill IR, Gill K, Jayasekera N, Miller J (2008) Medium term results of the collum femoris preserving hydroxyapatite coated total hip replacement. Hip Int 18:75–80PubMed Gill IR, Gill K, Jayasekera N, Miller J (2008) Medium term results of the collum femoris preserving hydroxyapatite coated total hip replacement. Hip Int 18:75–80PubMed
7.
go back to reference Gruen TA, Poggie RA, Lewallen DG, Hanssen AD, Lewis RJ, O’Keefe TJ, Stulberg SD, Sutherland CJ (2005) Radiographic evaluation of a monoblock acetabular component: a multicenter study with 2- to 5-year results. J Arthroplasty 20:369–378PubMedCrossRef Gruen TA, Poggie RA, Lewallen DG, Hanssen AD, Lewis RJ, O’Keefe TJ, Stulberg SD, Sutherland CJ (2005) Radiographic evaluation of a monoblock acetabular component: a multicenter study with 2- to 5-year results. J Arthroplasty 20:369–378PubMedCrossRef
8.
go back to reference Gulow J, Scholz R, Freiherr vS-S (2007) Short-stemmed endoprostheses in total hip arthroplasty. Orthopade 36:353–359PubMedCrossRef Gulow J, Scholz R, Freiherr vS-S (2007) Short-stemmed endoprostheses in total hip arthroplasty. Orthopade 36:353–359PubMedCrossRef
9.
go back to reference Hube R, Zaage M, Hein W, Reichel H (2004) Early functional results with the Mayo-hip, a short stem system with metaphyseal-intertrochanteric fixation. Orthopade 33:1249–1258PubMedCrossRef Hube R, Zaage M, Hein W, Reichel H (2004) Early functional results with the Mayo-hip, a short stem system with metaphyseal-intertrochanteric fixation. Orthopade 33:1249–1258PubMedCrossRef
10.
go back to reference Karrholm J, Herberts P, Hultmark P, Malchau H, Nivbrant B, Thanner J (1997) Radiostereometry of hip prostheses. Review of methodology and clinical results. Clin Orthop Relat Res 344:94–110 Karrholm J, Herberts P, Hultmark P, Malchau H, Nivbrant B, Thanner J (1997) Radiostereometry of hip prostheses. Review of methodology and clinical results. Clin Orthop Relat Res 344:94–110
11.
go back to reference Milecki M, Kowalczewski J, Wielopolski A, Obrebski M, Okon T, Marczak D (2008) Modular short-stem prosthesis in total hip arthroplasty—preliminary report. Chir Narzadow Ruchu Ortop Pol 73:244–247PubMed Milecki M, Kowalczewski J, Wielopolski A, Obrebski M, Okon T, Marczak D (2008) Modular short-stem prosthesis in total hip arthroplasty—preliminary report. Chir Narzadow Ruchu Ortop Pol 73:244–247PubMed
12.
go back to reference Morrey BF (1989) Short-stemmed uncemented femoral component for primary hip arthroplasty. Clin Orthop Relat Res 249:169–75 Morrey BF (1989) Short-stemmed uncemented femoral component for primary hip arthroplasty. Clin Orthop Relat Res 249:169–75
13.
go back to reference Neef R (2008) Klinische, radiologische und osteodensitometrischen Ergebnisse der Behandlung mit Hüft- Kurzschaftprothesen vom Typ CFP und Mayo. Dissertation. Martin-Luther-University Halle-Wittenberg, 2008, Halle, Univ., Diss Neef R (2008) Klinische, radiologische und osteodensitometrischen Ergebnisse der Behandlung mit Hüft- Kurzschaftprothesen vom Typ CFP und Mayo. Dissertation. Martin-Luther-University Halle-Wittenberg, 2008, Halle, Univ., Diss
14.
go back to reference Rohrl SM, Li MG, Pedersen E, Ullmark G, Nivbrant B (2006) Migration pattern of a short femoral neck preserving stem. Clin Orthop Relat Res 448:73–78PubMedCrossRef Rohrl SM, Li MG, Pedersen E, Ullmark G, Nivbrant B (2006) Migration pattern of a short femoral neck preserving stem. Clin Orthop Relat Res 448:73–78PubMedCrossRef
15.
go back to reference Roth A, Richartz G, Sander K, Sachse A, Fuhrmann R, Wagner A, Venbrocks RA (2005) Periprosthetic bone loss after total hip endoprosthesis. Dependence on the type of prosthesis and preoperative bone configuration. Orthopade 34:334–344PubMedCrossRef Roth A, Richartz G, Sander K, Sachse A, Fuhrmann R, Wagner A, Venbrocks RA (2005) Periprosthetic bone loss after total hip endoprosthesis. Dependence on the type of prosthesis and preoperative bone configuration. Orthopade 34:334–344PubMedCrossRef
16.
go back to reference Schutz U, Decking J, Decking R, Puhl W (2005) Assessment of femoral component migration in total hip arthroplasty: digital measurements compared to RSA. Acta Orthop Belg 71:65–75PubMed Schutz U, Decking J, Decking R, Puhl W (2005) Assessment of femoral component migration in total hip arthroplasty: digital measurements compared to RSA. Acta Orthop Belg 71:65–75PubMed
17.
go back to reference Strom H, Nilsson O, Milbrink J, Mallmin H, Larsson S (2007) The effect of early weight bearing on migration pattern of the uncemented CLS stem in total hip arthroplasty. J Arthroplasty 22:1122–1129PubMedCrossRef Strom H, Nilsson O, Milbrink J, Mallmin H, Larsson S (2007) The effect of early weight bearing on migration pattern of the uncemented CLS stem in total hip arthroplasty. J Arthroplasty 22:1122–1129PubMedCrossRef
18.
go back to reference Synder M, Drobniewski M, Pruszczynski B, Sibinski M (2009) Initial experience with short Metha stem implantation. Ortop Traumatol Rehabil 11:317–323PubMed Synder M, Drobniewski M, Pruszczynski B, Sibinski M (2009) Initial experience with short Metha stem implantation. Ortop Traumatol Rehabil 11:317–323PubMed
19.
go back to reference Thien TM, Ahnfelt L, Eriksson M, Stromberg C, Karrholm J (2007) Immediate weight bearing after uncemented total hip arthroplasty with an anteverted stem: a prospective randomized comparison using radiostereometry. Acta Orthop 78:730–738PubMedCrossRef Thien TM, Ahnfelt L, Eriksson M, Stromberg C, Karrholm J (2007) Immediate weight bearing after uncemented total hip arthroplasty with an anteverted stem: a prospective randomized comparison using radiostereometry. Acta Orthop 78:730–738PubMedCrossRef
20.
go back to reference Von Salis-Soglio G, Gulow J (2007) Große Gelenke: Hüfte: Kurzstiel. In: Gradinger H, Gollwitzer H (Hrsg.) Össäre Integration. Springer, Berlin, pp 116–119 Von Salis-Soglio G, Gulow J (2007) Große Gelenke: Hüfte: Kurzstiel. In: Gradinger H, Gollwitzer H (Hrsg.) Össäre Integration. Springer, Berlin, pp 116–119
21.
go back to reference Westphal FM, Bishop N, Honl M, Hille E, Puschel K, Morlock MM (2006) Migration and cyclic motion of a new short-stemmed hip prosthesis—a biomechanical in vitro study. Clin Biomech (Bristol Avon) 21:834–840CrossRef Westphal FM, Bishop N, Honl M, Hille E, Puschel K, Morlock MM (2006) Migration and cyclic motion of a new short-stemmed hip prosthesis—a biomechanical in vitro study. Clin Biomech (Bristol Avon) 21:834–840CrossRef
22.
go back to reference Wick M, Lester DK (2004) Radiological changes in second- and third-generation Zweymuller stems. J Bone Joint Surg Br 86:1108–1114PubMedCrossRef Wick M, Lester DK (2004) Radiological changes in second- and third-generation Zweymuller stems. J Bone Joint Surg Br 86:1108–1114PubMedCrossRef
23.
go back to reference Zeh A, Weise A, Vasarhelyi A, Bach AG, Wohlrab D (2011) Medium-term results of the mayo short-stem hip prosthesis after avascular necrosis of the femoral head. Z Orthop Unfall 149:200–205PubMedCrossRef Zeh A, Weise A, Vasarhelyi A, Bach AG, Wohlrab D (2011) Medium-term results of the mayo short-stem hip prosthesis after avascular necrosis of the femoral head. Z Orthop Unfall 149:200–205PubMedCrossRef
24.
go back to reference Zweymuller KA, Schwarzinger UM, Steindl MS (2006) Radiolucent lines and osteolysis along tapered straight cementless titanium hip stems: a comparison of 6-year and 10-year follow-up results in 95 patients. Acta Orthop 77:871–876PubMedCrossRef Zweymuller KA, Schwarzinger UM, Steindl MS (2006) Radiolucent lines and osteolysis along tapered straight cementless titanium hip stems: a comparison of 6-year and 10-year follow-up results in 95 patients. Acta Orthop 77:871–876PubMedCrossRef
Metadata
Title
Is there an increased stem migration or compromised osteointegration of the Mayo™ short-stemmed prosthesis following cerclage wiring of an intrasurgical periprosthetic fracture?
Authors
Alexander Zeh
Florian Radetzki
Verena Diers
Dirk Bach
Marc Röllinghoff
Karl Stefan Delank
Publication date
01-12-2011
Publisher
Springer-Verlag
Published in
Archives of Orthopaedic and Trauma Surgery / Issue 12/2011
Print ISSN: 0936-8051
Electronic ISSN: 1434-3916
DOI
https://doi.org/10.1007/s00402-011-1342-1

Other articles of this Issue 12/2011

Archives of Orthopaedic and Trauma Surgery 12/2011 Go to the issue