Skip to main content
Top
Literature
1.
go back to reference Mathew P, Lewis C, Neglia J et al (1997) Interaction between electronic article surveillance systems and implantable defibrillators: insights from a fourth generation ICD. Pacing Clin Electrophysiol 20:2857e9CrossRef Mathew P, Lewis C, Neglia J et al (1997) Interaction between electronic article surveillance systems and implantable defibrillators: insights from a fourth generation ICD. Pacing Clin Electrophysiol 20:2857e9CrossRef
2.
go back to reference Madrid A, Sanchez A, Bosch E et al (1997) Dysfunction of implantable defibrillators caused by slot machines. Pacing Clin Electrophysiol 20:212e4CrossRef Madrid A, Sanchez A, Bosch E et al (1997) Dysfunction of implantable defibrillators caused by slot machines. Pacing Clin Electrophysiol 20:212e4CrossRef
3.
go back to reference Seifert T, Block M, Borggrefe M et al (1995) Erroneous discharge of an implantable cardioverter defibrillator caused by an electric razor. Pacing Clin Electrophysiol 18:1592e4CrossRef Seifert T, Block M, Borggrefe M et al (1995) Erroneous discharge of an implantable cardioverter defibrillator caused by an electric razor. Pacing Clin Electrophysiol 18:1592e4CrossRef
4.
go back to reference Man KC, Davidson T, Langberg JJ et al (1993) Interference from a hand held radiofrequency remote control causing discharge of an implantable defibrillator. Pacing Clin Electrophysiol 16:1756e8CrossRef Man KC, Davidson T, Langberg JJ et al (1993) Interference from a hand held radiofrequency remote control causing discharge of an implantable defibrillator. Pacing Clin Electrophysiol 16:1756e8CrossRef
5.
go back to reference Wayar L, Mont L, Silva RMFL et al (2003) Electrical interference from an abdominal muscle stimulator unit on an implantable cardioverter defibrillator: report of two consecutive cases. Pacing Clin Electrophysiol 26:1292e3CrossRef Wayar L, Mont L, Silva RMFL et al (2003) Electrical interference from an abdominal muscle stimulator unit on an implantable cardioverter defibrillator: report of two consecutive cases. Pacing Clin Electrophysiol 26:1292e3CrossRef
6.
go back to reference Sabate X, Moure C, Nicolas J et al (2001) Washing machine associated 50 Hz detected as ventricular fibrillation by an implanted cardioverter defibrillator. Pacing Clin Electrophysiol 24:1281e3CrossRef Sabate X, Moure C, Nicolas J et al (2001) Washing machine associated 50 Hz detected as ventricular fibrillation by an implanted cardioverter defibrillator. Pacing Clin Electrophysiol 24:1281e3CrossRef
7.
go back to reference Diez C, Hofmann HS, Börgermann J (2009) Atrial and ventricular lead insulation defects with resulting inappropriate shocks and end-of-life of the ICD impulse generator in a young bodybuilder with congenital long-QT syndrome. J Clin Res Cardiol 98(1):16–18 [Epub 2008 Sep 5] Diez C, Hofmann HS, Börgermann J (2009) Atrial and ventricular lead insulation defects with resulting inappropriate shocks and end-of-life of the ICD impulse generator in a young bodybuilder with congenital long-QT syndrome. J Clin Res Cardiol 98(1):16–18 [Epub 2008 Sep 5]
8.
go back to reference Vlay SC (2002) Fish pond electromagnetic interference resulting in an inappropriate implantable cardioverter defibrillator shock. Pacing Clin Electrophysiol 25:1532CrossRefPubMed Vlay SC (2002) Fish pond electromagnetic interference resulting in an inappropriate implantable cardioverter defibrillator shock. Pacing Clin Electrophysiol 25:1532CrossRefPubMed
9.
go back to reference Hauck M, Bauer A, Voss F, Weretka S et al (2009) “Home monitoring” for early detection of implantable cardioverter-defibrillator failure: a single-center prospective observational study. Clin Res Cardiol 98(1):19–24 [Epub 2008 Sep 5] Hauck M, Bauer A, Voss F, Weretka S et al (2009) “Home monitoring” for early detection of implantable cardioverter-defibrillator failure: a single-center prospective observational study. Clin Res Cardiol 98(1):19–24 [Epub 2008 Sep 5]
Metadata
Title
Inappropriate shock delivery by implantable cardioverter defibrillator due to electrical leak from bathroom tap
Authors
Ahmet Çamsarı
Dilek Çiçek Yılmaz
Türkay Özcan
Publication date
01-11-2010
Publisher
Springer-Verlag
Published in
Clinical Research in Cardiology / Issue 11/2010
Print ISSN: 1861-0684
Electronic ISSN: 1861-0692
DOI
https://doi.org/10.1007/s00392-010-0202-2