Skip to main content
Top
Published in: Heart and Vessels 11/2020

01-11-2020 | Valvuloplasty | Letter

Role of palliative balloon pulmonary valvuloplasty in babies with tetralogy of Fallot

Author: P. Syamasundar Rao

Published in: Heart and Vessels | Issue 11/2020

Login to get access

Excerpt

Muneuch and colleagues [1] sought to determine whether balloon pulmonary valvuloplasty (BPV) in babies with tetralogy of Fallot (TOF) prevented early surgical correction. The results of BPV in 31 babies at a mean age of 19 days (range 14–33 days) revealed that early palliative BPV avoided early corrective surgery in only half of the babies but, did not prevent the placement of transannular patch. The severity of infundibular obstruction appears to be responsible, at least in part, for lack benefit of BPV. This is a thoughtfully conducted and well-written study. However, there are some issues that are worthy of further discussion. …
Literature
1.
go back to reference Muneuchi J, Watanabe M, Sugitani Y, Kawaguchi N, Matsuoka R, Ando Y, Ochiai Y (2020) Early palliative balloon pulmonary valvuloplasty in neonates and young infants with tetralogy of Fallot. Heart Vessels 35:252–258CrossRef Muneuchi J, Watanabe M, Sugitani Y, Kawaguchi N, Matsuoka R, Ando Y, Ochiai Y (2020) Early palliative balloon pulmonary valvuloplasty in neonates and young infants with tetralogy of Fallot. Heart Vessels 35:252–258CrossRef
2.
go back to reference Rao PS (1987) Balloon pulmonary valvuloplasty for complex cyanotic heart defects. Presented at the pediatric cardiology international congress, Vienna, Austria, February 21–25 Rao PS (1987) Balloon pulmonary valvuloplasty for complex cyanotic heart defects. Presented at the pediatric cardiology international congress, Vienna, Austria, February 21–25
3.
go back to reference Rao PS, Brais M (1988) Balloon pulmonary valvuloplasty for congenital cyanotic heart defects. Am Heart J 115:1105–1110CrossRef Rao PS, Brais M (1988) Balloon pulmonary valvuloplasty for congenital cyanotic heart defects. Am Heart J 115:1105–1110CrossRef
4.
go back to reference Rao PS, Wilson AD, Thapar MK, Brais M (1992) Balloon pulmonary valvuloplasty in the management of cyanotic congenital heart defects. Cath Cardiovasc Diagn 25:16–24CrossRef Rao PS, Wilson AD, Thapar MK, Brais M (1992) Balloon pulmonary valvuloplasty in the management of cyanotic congenital heart defects. Cath Cardiovasc Diagn 25:16–24CrossRef
5.
go back to reference Rao P (1989) Balloon dilatation in infants and children with cardiac defects. Cath Cardiovasc Diagn 18:136–149CrossRef Rao P (1989) Balloon dilatation in infants and children with cardiac defects. Cath Cardiovasc Diagn 18:136–149CrossRef
6.
go back to reference Rao PS (1989) Balloon angioplasty and valvuloplasty in infants, children and adolescents. Curr Probl Cardiol 14(8):417–497CrossRef Rao PS (1989) Balloon angioplasty and valvuloplasty in infants, children and adolescents. Curr Probl Cardiol 14(8):417–497CrossRef
7.
go back to reference Rao PS (1992) Transcatheter management of cyanotic congenital heart defects: a review. Clin Cardiol 15:483–496CrossRef Rao PS (1992) Transcatheter management of cyanotic congenital heart defects: a review. Clin Cardiol 15:483–496CrossRef
8.
go back to reference Rao PS (1993) Role of balloon dilatation and other transcatheter methods in the treatment of cyanotic congenital heart defects. In: Rao PS (ed) Transcatheter therapy in pediatric cardiology. Wiley-Liss, New York, pp 229–253 Rao PS (1993) Role of balloon dilatation and other transcatheter methods in the treatment of cyanotic congenital heart defects. In: Rao PS (ed) Transcatheter therapy in pediatric cardiology. Wiley-Liss, New York, pp 229–253
9.
go back to reference Rao PS (2007) Pulmonary valve in cyanotic heart defects with pulmonary oligemia. In: Sievert H, Qureshi SA, Wilson N, Hijazi Z (eds) Percutaneous interventions in congenital heart disease. Informa Health Care, Oxford, pp 197–200 Rao PS (2007) Pulmonary valve in cyanotic heart defects with pulmonary oligemia. In: Sievert H, Qureshi SA, Wilson N, Hijazi Z (eds) Percutaneous interventions in congenital heart disease. Informa Health Care, Oxford, pp 197–200
10.
go back to reference Rao PS (2014) Pulmonary valve disease: Pulmonary valve in cyanotic heart defects with pulmonary oligemia. In: Sievert H, Qureshi SA, Wilson N, Hijazi Z (eds) Interventions in structural, valvular and congenital heart disease. CRC Press, USA, pp 297–308 Rao PS (2014) Pulmonary valve disease: Pulmonary valve in cyanotic heart defects with pulmonary oligemia. In: Sievert H, Qureshi SA, Wilson N, Hijazi Z (eds) Interventions in structural, valvular and congenital heart disease. CRC Press, USA, pp 297–308
11.
go back to reference Battistessa SA, Robles A, Jackson M, Miyamoto S, Arnold R, McKay R (1990) Operative findings after percutaneous pulmonary balloon dilatation of right ventricular outflow tract in tetralogy of Fallot. Br Heart J 64:321–324CrossRef Battistessa SA, Robles A, Jackson M, Miyamoto S, Arnold R, McKay R (1990) Operative findings after percutaneous pulmonary balloon dilatation of right ventricular outflow tract in tetralogy of Fallot. Br Heart J 64:321–324CrossRef
12.
go back to reference Sreeram N, Saleem M, Jackson M, Peart I, McKay R, Arnold R, Walsh K (1991) Results of balloon pulmonary valvuloplasty as a palliative procedure in tetralogy of Fallot. J Am Coll Cardiol 8:159–165CrossRef Sreeram N, Saleem M, Jackson M, Peart I, McKay R, Arnold R, Walsh K (1991) Results of balloon pulmonary valvuloplasty as a palliative procedure in tetralogy of Fallot. J Am Coll Cardiol 8:159–165CrossRef
Metadata
Title
Role of palliative balloon pulmonary valvuloplasty in babies with tetralogy of Fallot
Author
P. Syamasundar Rao
Publication date
01-11-2020
Publisher
Springer Japan
Published in
Heart and Vessels / Issue 11/2020
Print ISSN: 0910-8327
Electronic ISSN: 1615-2573
DOI
https://doi.org/10.1007/s00380-020-01628-7

Other articles of this Issue 11/2020

Heart and Vessels 11/2020 Go to the issue