Skip to main content
Top
Published in: European Radiology 5/2014

01-05-2014 | Cardiac

Impact of sirolimus-eluting stent fractures without early cardiac events on long-term clinical outcomes: A multislice computed tomography study

Authors: Tsuyoshi Ito, Masashi Kimura, Mariko Ehara, Mitsuyasu Terashima, Kenya Nasu, Yoshihisa Kinoshita, Maoto Habara, Etsuo Tsuchikane, Takahiko Suzuki

Published in: European Radiology | Issue 5/2014

Login to get access

Abstract

Objectives

This study sought to evaluate the impact of sirolimus-eluting stent (SES) fractures on long-term clinical outcomes using multislice computed tomography (MSCT).

Methods

In this study, 528 patients undergoing 6- to 18-month follow-up 64-slice MSCT after SES implantation without early clinical events were followed clinically (the median follow-up interval was 4.6 years). A CT-detected stent fracture was defined as a complete gap with Hounsfield units (HU) <300 at the site of separation. The major adverse cardiac events (MACEs), including cardiac death, stent thrombosis, and target lesion revascularisation, were compared according to the presence of stent fracture.

Results

Stent fractures were observed in 39 patients (7.4 %). MACEs were more common in patients with CT-detected stent fractures than in those without (46 % vs. 7 %, p < 0.01). Univariate Cox regression analysis indicated a significant relationship between MACE and stent fracture [hazard ratio (HR) 7.65; p < 0.01], age (HR 1.03; p = 0.04), stent length (HR 1.03; p < 0.01), diabetes mellitus (HR 1.77; p = 0.04), and chronic total occlusion (HR 2.54; p = 0.01). In the multivariate model, stent fracture (HR 5.36; p < 0.01) and age (HR 1.03; p = 0.04) remained significant predictors of MACE.

Conclusions

An SES fracture detected by MSCT without early clinical events was associated with long-term clinical adverse events.

Key points

Long-term outcomes of sirolimus-eluting stent fracture have not been fully clarified.
MSCT could detect stent fracture with high accuracy.
Sirolimus-eluting stent fracture detected by MSCT was associated with long-term adverse events.
Literature
1.
go back to reference Morice MC, Serruys PW, Sousa JE et al (2002) A randomized comparison of a sirolimus-eluting stent with a standard stent for coronary revascularization. N Engl J Med 346:1773–80PubMedCrossRef Morice MC, Serruys PW, Sousa JE et al (2002) A randomized comparison of a sirolimus-eluting stent with a standard stent for coronary revascularization. N Engl J Med 346:1773–80PubMedCrossRef
2.
go back to reference Stone GW, Moses JW, Ellis SG et al (2007) Safety and efficacy of sirolimus- and paclitaxel-eluting coronary stents. N Engl J Med 356:998–1008PubMedCrossRef Stone GW, Moses JW, Ellis SG et al (2007) Safety and efficacy of sirolimus- and paclitaxel-eluting coronary stents. N Engl J Med 356:998–1008PubMedCrossRef
3.
go back to reference Zellweger MJ, Kaiser C, Jeger R et al (2012) Coronary artery disease progression late after successful stent implantation. J Am Coll Cardiol 59:793–9PubMedCrossRef Zellweger MJ, Kaiser C, Jeger R et al (2012) Coronary artery disease progression late after successful stent implantation. J Am Coll Cardiol 59:793–9PubMedCrossRef
4.
go back to reference Kimura T, Morimoto T, Nakagawa Y et al (2012) Very late stent thrombosis and late target lesion revascularization after sirolimus-eluting stent implantation: five-year outcome of the j-Cypher Registry. Circulation 125:584–91PubMedCrossRef Kimura T, Morimoto T, Nakagawa Y et al (2012) Very late stent thrombosis and late target lesion revascularization after sirolimus-eluting stent implantation: five-year outcome of the j-Cypher Registry. Circulation 125:584–91PubMedCrossRef
5.
go back to reference Aoki J, Nakazawa G, Tanabe K et al (2007) Incidence and clinical impact of coronary stent fracture after sirolimus-eluting stent implantation. Catheter Cardiovasc Interv 69:380–6PubMedCrossRef Aoki J, Nakazawa G, Tanabe K et al (2007) Incidence and clinical impact of coronary stent fracture after sirolimus-eluting stent implantation. Catheter Cardiovasc Interv 69:380–6PubMedCrossRef
6.
go back to reference Popma JJ, Tiroch K, Almonacid A, Cohen S, Kandzari DE, Leon MB (2009) A qualitative and quantitative angiographic analysis of stent fracture late following sirolimus-eluting stent implantation. Am J Cardiol 103:923–9PubMedCrossRef Popma JJ, Tiroch K, Almonacid A, Cohen S, Kandzari DE, Leon MB (2009) A qualitative and quantitative angiographic analysis of stent fracture late following sirolimus-eluting stent implantation. Am J Cardiol 103:923–9PubMedCrossRef
7.
go back to reference Chung WS, Park CS, Seung KB et al (2008) The incidence and clinical impact of stent strut fractures developed after drug-eluting stent implantation. Int J Cardiol 125:325–31PubMedCrossRef Chung WS, Park CS, Seung KB et al (2008) The incidence and clinical impact of stent strut fractures developed after drug-eluting stent implantation. Int J Cardiol 125:325–31PubMedCrossRef
8.
go back to reference Umeda H, Gochi T, Iwase M et al (2009) Frequency, predictors and outcome of stent fracture after sirolimus-eluting stent implantation. Int J Cardiol 133:321–6PubMedCrossRef Umeda H, Gochi T, Iwase M et al (2009) Frequency, predictors and outcome of stent fracture after sirolimus-eluting stent implantation. Int J Cardiol 133:321–6PubMedCrossRef
9.
go back to reference Raff GL, Gallagher MJ, O’Neill WW, Goldstein JA (2005) Diagnostic accuracy of noninvasive coronary angiography using 64-slice spiral computed tomography. J Am Coll Cardiol 46:552–7PubMedCrossRef Raff GL, Gallagher MJ, O’Neill WW, Goldstein JA (2005) Diagnostic accuracy of noninvasive coronary angiography using 64-slice spiral computed tomography. J Am Coll Cardiol 46:552–7PubMedCrossRef
10.
go back to reference Leber AW, Knez A, Becker A et al (2004) Accuracy of multidetector spiral computed tomography in identifying and differentiating the composition of coronary atherosclerotic plaques: a comparative study with intracoronary ultrasound. J Am Coll Cardiol 43:1241–7PubMedCrossRef Leber AW, Knez A, Becker A et al (2004) Accuracy of multidetector spiral computed tomography in identifying and differentiating the composition of coronary atherosclerotic plaques: a comparative study with intracoronary ultrasound. J Am Coll Cardiol 43:1241–7PubMedCrossRef
11.
go back to reference Ito T, Terashima M, Kaneda H et al (2011) Comparison of in vivo assessment of vulnerable plaque by 64-slice multislice computed tomography versus optical coherence tomography. Am J Cardiol 107:1270–7PubMedCrossRef Ito T, Terashima M, Kaneda H et al (2011) Comparison of in vivo assessment of vulnerable plaque by 64-slice multislice computed tomography versus optical coherence tomography. Am J Cardiol 107:1270–7PubMedCrossRef
12.
go back to reference Motoyama S, Sarai M, Harigaya H et al (2009) Computed tomographic angiography characteristics of atherosclerotic plaques subsequently resulting in acute coronary syndrome. J Am Coll Cardiol 54:49–57PubMedCrossRef Motoyama S, Sarai M, Harigaya H et al (2009) Computed tomographic angiography characteristics of atherosclerotic plaques subsequently resulting in acute coronary syndrome. J Am Coll Cardiol 54:49–57PubMedCrossRef
13.
go back to reference Hulten EA, Carbonaro S, Petrillo SP, Mitchell JD, Villines TC (2011) Prognostic value of cardiac computed tomography angiography: a systematic review and meta-analysis. J Am Coll Cardiol 57:1237–47PubMedCrossRef Hulten EA, Carbonaro S, Petrillo SP, Mitchell JD, Villines TC (2011) Prognostic value of cardiac computed tomography angiography: a systematic review and meta-analysis. J Am Coll Cardiol 57:1237–47PubMedCrossRef
14.
go back to reference Lim HB, Hur G, Kim SY et al (2008) Coronary stent fracture: detection with 64-section multidetector CT angiography in patients and in vitro. Radiology 249:810–9PubMedCrossRef Lim HB, Hur G, Kim SY et al (2008) Coronary stent fracture: detection with 64-section multidetector CT angiography in patients and in vitro. Radiology 249:810–9PubMedCrossRef
15.
go back to reference Hecht HS, Polena S, Jelnin V et al (2009) Stent gap by 64-detector computed tomographic angiography relationship to in-stent restenosis, fracture, and overlap failure. J Am Coll Cardiol 54:1949–59PubMedCrossRef Hecht HS, Polena S, Jelnin V et al (2009) Stent gap by 64-detector computed tomographic angiography relationship to in-stent restenosis, fracture, and overlap failure. J Am Coll Cardiol 54:1949–59PubMedCrossRef
16.
go back to reference Ito T, Ehara M, Suzuki T (2012) Multiple stent fractures detected by multislice computed tomography after full metal jacket stents. Eur Heart J Cardiovasc Imaging 13:631PubMedCrossRef Ito T, Ehara M, Suzuki T (2012) Multiple stent fractures detected by multislice computed tomography after full metal jacket stents. Eur Heart J Cardiovasc Imaging 13:631PubMedCrossRef
17.
go back to reference Ito T, Terashima M, Kaneda H et al (2011) Very late sirolimus-eluting stent thrombosis due to stent fracture and late-acquired incomplete stent apposition detected on multislice computed tomography. Circ J 75:2716–7PubMedCrossRef Ito T, Terashima M, Kaneda H et al (2011) Very late sirolimus-eluting stent thrombosis due to stent fracture and late-acquired incomplete stent apposition detected on multislice computed tomography. Circ J 75:2716–7PubMedCrossRef
18.
go back to reference Mauri L, Hsieh WH, Massaro JM, Ho KK, D’Agostino R, Cutlip DE (2007) Stent thrombosis in randomized clinical trials of drug-eluting stents. N Engl J Med 356:1020–9PubMedCrossRef Mauri L, Hsieh WH, Massaro JM, Ho KK, D’Agostino R, Cutlip DE (2007) Stent thrombosis in randomized clinical trials of drug-eluting stents. N Engl J Med 356:1020–9PubMedCrossRef
19.
go back to reference Nakazawa G, Finn AV, Vorpahl M et al (2009) Incidence and predictors of drug-eluting stent fracture in human coronary artery a pathologic analysis. J Am Coll Cardiol 54:1924–31PubMedCrossRef Nakazawa G, Finn AV, Vorpahl M et al (2009) Incidence and predictors of drug-eluting stent fracture in human coronary artery a pathologic analysis. J Am Coll Cardiol 54:1924–31PubMedCrossRef
20.
go back to reference Yamada KP, Koizumi T, Yamaguchi H et al (2008) Serial angiographic and intravascular ultrasound analysis of late stent strut fracture of sirolimus-eluting stents in native coronary arteries. Int J Cardiol 130:255–9PubMedCrossRef Yamada KP, Koizumi T, Yamaguchi H et al (2008) Serial angiographic and intravascular ultrasound analysis of late stent strut fracture of sirolimus-eluting stents in native coronary arteries. Int J Cardiol 130:255–9PubMedCrossRef
21.
go back to reference Pang JH, Kim D, Beohar N, Meyers SN, Lloyd-Jones D, Yaghmai V (2009) Detection of stent fractures: a comparison of 64-slice CT, conventional cine-angiography, and intravascular ultrasonography. Acad Radiol 16:412–7PubMedCrossRef Pang JH, Kim D, Beohar N, Meyers SN, Lloyd-Jones D, Yaghmai V (2009) Detection of stent fractures: a comparison of 64-slice CT, conventional cine-angiography, and intravascular ultrasonography. Acad Radiol 16:412–7PubMedCrossRef
22.
go back to reference Umeda H, Kawai T, Misumida N et al (2011) Impact of sirolimus-eluting stent fracture on 4-year clinical outcomes. Circ Cardiovasc Interv 4:349–54PubMedCrossRef Umeda H, Kawai T, Misumida N et al (2011) Impact of sirolimus-eluting stent fracture on 4-year clinical outcomes. Circ Cardiovasc Interv 4:349–54PubMedCrossRef
23.
go back to reference Ino Y, Toyoda Y, Tanaka A et al (2010) Serial angiographic findings and prognosis of stent fracture site without early restenosis after sirolimus-eluting stent implantation. Am Heart J 160:775.e1–9CrossRef Ino Y, Toyoda Y, Tanaka A et al (2010) Serial angiographic findings and prognosis of stent fracture site without early restenosis after sirolimus-eluting stent implantation. Am Heart J 160:775.e1–9CrossRef
24.
go back to reference Kim U, Kim DI, Kim DK et al (2012) Long-term clinical and angiographic outcomes of patients with sirolimus-eluting stent fracture. Int J Cardiol 158:83–7PubMedCrossRef Kim U, Kim DI, Kim DK et al (2012) Long-term clinical and angiographic outcomes of patients with sirolimus-eluting stent fracture. Int J Cardiol 158:83–7PubMedCrossRef
25.
go back to reference Hara H, Aoki J, Tanabe K et al (2013) Incidence and predictors for late target lesion revascularization after sirolimus-eluting stent implantation. Circ J 77:988–94PubMedCrossRef Hara H, Aoki J, Tanabe K et al (2013) Incidence and predictors for late target lesion revascularization after sirolimus-eluting stent implantation. Circ J 77:988–94PubMedCrossRef
26.
go back to reference Kashiwagi M, Tanaka A, Kitabata H et al (2012) OCT-verified neointimal hyperplasia is increased at fracture site in drug-eluting stents. JACC Cardiovasc Imaging 5:232–3PubMedCrossRef Kashiwagi M, Tanaka A, Kitabata H et al (2012) OCT-verified neointimal hyperplasia is increased at fracture site in drug-eluting stents. JACC Cardiovasc Imaging 5:232–3PubMedCrossRef
27.
go back to reference Doi H, Maehara A, Mintz GS et al (2009) Classification and potential mechanisms of intravascular ultrasound patterns of stent fracture. Am J Cardiol 103:818–23PubMedCrossRef Doi H, Maehara A, Mintz GS et al (2009) Classification and potential mechanisms of intravascular ultrasound patterns of stent fracture. Am J Cardiol 103:818–23PubMedCrossRef
28.
go back to reference Taylor AJ, Cerqueira M, Hodgson JM et al (2010) ACCF/SCCT/ACR/AHA/ASE/ASNC/NASCI/SCAI/SCMR 2010 appropriate use criteria for cardiac computed tomography. A report of the American College of Cardiology Foundation Appropriate Use Criteria Task Force, the Society of Cardiovascular Computed Tomography, the American College of Radiology, the American Heart Association, the American Society of Echocardiography, the American Society of Nuclear Cardiology, the North American Society for Cardiovascular Imaging, the Society for Cardiovascular Angiography and Interventions, and the Society for Cardiovascular Magnetic Resonance. J Am Coll Cardiol 56:1864–94PubMedCrossRef Taylor AJ, Cerqueira M, Hodgson JM et al (2010) ACCF/SCCT/ACR/AHA/ASE/ASNC/NASCI/SCAI/SCMR 2010 appropriate use criteria for cardiac computed tomography. A report of the American College of Cardiology Foundation Appropriate Use Criteria Task Force, the Society of Cardiovascular Computed Tomography, the American College of Radiology, the American Heart Association, the American Society of Echocardiography, the American Society of Nuclear Cardiology, the North American Society for Cardiovascular Imaging, the Society for Cardiovascular Angiography and Interventions, and the Society for Cardiovascular Magnetic Resonance. J Am Coll Cardiol 56:1864–94PubMedCrossRef
29.
go back to reference Pugliese F, Weustink AC, Van Mieghem C et al (2008) Dual source coronary computed tomography angiography for detecting in-stent restenosis. Heart 94:848–54PubMedCrossRef Pugliese F, Weustink AC, Van Mieghem C et al (2008) Dual source coronary computed tomography angiography for detecting in-stent restenosis. Heart 94:848–54PubMedCrossRef
30.
go back to reference de Graaf FR, Schuijf JD, van Velzen JE et al (2010) Diagnostic accuracy of 320-row multidetector computed tomography coronary angiography to noninvasively assess in-stent restenosis. Invest Radiol 45:331–40PubMed de Graaf FR, Schuijf JD, van Velzen JE et al (2010) Diagnostic accuracy of 320-row multidetector computed tomography coronary angiography to noninvasively assess in-stent restenosis. Invest Radiol 45:331–40PubMed
Metadata
Title
Impact of sirolimus-eluting stent fractures without early cardiac events on long-term clinical outcomes: A multislice computed tomography study
Authors
Tsuyoshi Ito
Masashi Kimura
Mariko Ehara
Mitsuyasu Terashima
Kenya Nasu
Yoshihisa Kinoshita
Maoto Habara
Etsuo Tsuchikane
Takahiko Suzuki
Publication date
01-05-2014
Publisher
Springer Berlin Heidelberg
Published in
European Radiology / Issue 5/2014
Print ISSN: 0938-7994
Electronic ISSN: 1432-1084
DOI
https://doi.org/10.1007/s00330-014-3118-9

Other articles of this Issue 5/2014

European Radiology 5/2014 Go to the issue