Abstract

Background

The purpose of this study was to investigate the incidence of dislocation and specific complications of the dual-mobility cup.

Methods

The arthroplasties involved 167 hips in 165 patients; 51 hips (30.5%) were in men and 116 (69.4%) were in women. The active articulation E1® dual-mobility cup (Biomet, Warsaw, IN, USA) was used, and the surgical approach was posterolateral in 120 hips and anterolateral in 47 hips.

Results

Four (2.3%) dislocations were observed. Mean time of dislocation was 30.5 days post-operatively. Three incomplete reductions occurred during closed reduction. When comparing parameters between dislocation and no-dislocation groups, there were no differences in patient and surgical parameters. However, all dislocations occurred in patients with femoral neck fractures and in the posterolateral approach group.

Conclusion

The incidence of dislocation in total hip arthroplasty (THA) using a dual-mobility cup was acceptable, and cup diameter of the dislocation group was substantially larger than that of no-dislocation group. Based on clinical outcomes of our study, we conclude that the dual-mobility cup is a reliable option in THA, and further studies are necessary.
Literature
6.
go back to reference Lachiewicz PF, Kelley SS (2002) The use of constrained components in total hip arthroplasty. J Am Acad Orthop Surg 10:233–238CrossRefPubMed Lachiewicz PF, Kelley SS (2002) The use of constrained components in total hip arthroplasty. J Am Acad Orthop Surg 10:233–238CrossRefPubMed
18.
go back to reference Berry DJ, von Knoch M, Schleck CD, Harmsen WS (2004) The cumulative long-term risk of dislocation after primary Charnley total hip arthroplasty. J Bone Joint Surg Am 86-A:9–14CrossRefPubMed Berry DJ, von Knoch M, Schleck CD, Harmsen WS (2004) The cumulative long-term risk of dislocation after primary Charnley total hip arthroplasty. J Bone Joint Surg Am 86-A:9–14CrossRefPubMed
20.
go back to reference Clohisy JC, Harris WH (1999) Primary hybrid total hip replacement, performed with insertion of the acetabular component without cement and a precoat femoral component with cement. An average ten-year follow-up study. J Bone Joint Surg Am 81-A:247–255CrossRef Clohisy JC, Harris WH (1999) Primary hybrid total hip replacement, performed with insertion of the acetabular component without cement and a precoat femoral component with cement. An average ten-year follow-up study. J Bone Joint Surg Am 81-A:247–255CrossRef
21.
go back to reference Harris WH (1969) Traumatic arthritis of the hip after dislocation and acetabular fractures: treatment by mold arthroplasty. An end-result study using a new method of result evaluation. J Bone Joint Surg Am 51-A:737–755CrossRef Harris WH (1969) Traumatic arthritis of the hip after dislocation and acetabular fractures: treatment by mold arthroplasty. An end-result study using a new method of result evaluation. J Bone Joint Surg Am 51-A:737–755CrossRef
22.
go back to reference Woo RYG, Morrey BF (1982) Dislocations after total hip arthroplasty. J Bone Joint Surg Am 64-A:1295–1306CrossRef Woo RYG, Morrey BF (1982) Dislocations after total hip arthroplasty. J Bone Joint Surg Am 64-A:1295–1306CrossRef
27.
go back to reference Bousquet G, Gazielly DF, Debiesse JL (1985) The ceramic coated cementless total hip arthroplasty: Basic concepts and surgical technique. J Orthopaedic Surg Tech 1:15–28 Bousquet G, Gazielly DF, Debiesse JL (1985) The ceramic coated cementless total hip arthroplasty: Basic concepts and surgical technique. J Orthopaedic Surg Tech 1:15–28
36.
go back to reference Masonis JL, Bourne RB (2002) Surgical approach, abductor function, and total hip arthroplasty dislocation. Clin Orthop Relat Res 405:46–53CrossRef Masonis JL, Bourne RB (2002) Surgical approach, abductor function, and total hip arthroplasty dislocation. Clin Orthop Relat Res 405:46–53CrossRef
37.
go back to reference Soong M, Rubash HE, Macaulay W (2004) Dislocation after total hip arthroplasty. J Am Acad Orthop Surg 12:314–321CrossRefPubMed Soong M, Rubash HE, Macaulay W (2004) Dislocation after total hip arthroplasty. J Am Acad Orthop Surg 12:314–321CrossRefPubMed
38.
go back to reference Roberts JM, Fu FH, McClain EJ, Ferguson AB Jr (1984) A comparison of the posterolateral and anterolateral approaches to total hip arthroplasty. Clin Orthop Relat Res 187:205–210 Roberts JM, Fu FH, McClain EJ, Ferguson AB Jr (1984) A comparison of the posterolateral and anterolateral approaches to total hip arthroplasty. Clin Orthop Relat Res 187:205–210
Metadata
Title
Dislocations after use of dual-mobility cups in cementless primary total hip arthroplasty: prospective multicentre series
Authors
Ji-hyo Hwang
Sang-Min Kim
Kwang-Jun Oh
Yeesuk Kim
Publication date
01-04-2018
Publisher
Springer Berlin Heidelberg
Published in
International Orthopaedics / Issue 4/2018
Print ISSN: 0341-2695
Electronic ISSN: 1432-5195
DOI
https://doi.org/10.1007/s00264-017-3660-6

Other articles of this Issue 4/2018

International Orthopaedics 4/2018 Go to the issue