Published in: International Orthopaedics 12/2013

01-12-2013 | Original Paper

Dual mobility cup: dislocation rate and survivorship at ten years of follow-up

Authors: Jean-Louis Prudhon, André Ferreira, Régis Verdier

Published in: International Orthopaedics | Issue 12/2013

Login to get access

Abstract

Purpose

The dual mobility cup introduced in France by Gilles Bousquet has been used in total hip replacement in high-risk patients. This device acts as a large ball implant and significantly reduces the risk of dislocation following hip arthroplasty. Published French literature has focused on low rates of dislocation and long-term follow-up similar to the low-friction arthroplasty.

Methods

We retrospectively reviewed a continuous series of 105 cases of dual mobility cup Quattro (Groupe Lépine, Genay, France) implanted from 2000 to 2002. Selection of the patients requiring a primary hip replacement depended on risk criteria such as age, hip disease and activity score. The dual mobility cup was associated with a modular cemented femoral component and a 22.2-mm stainless steel head.

Results

One dislocation occurred one month after the index surgery requiring no revision surgery. According to the Kaplan-Meier method, survival probability was 95.0 % (95 % confidence interval 81.5–98.8) at ten years of follow-up.

Conclusions

Based on clinical outcome and patient assessment we conclude that the dual mobility cup is a reliable option to decrease dislocation risk without increasing polyethylene wear.
Literature
1.
go back to reference Bozic KJ, Kurtz SM, Lau E, Ong K, Vail TP, Berry DJ (2009) The epidemiology of revision total hip arthroplasty in the United States. J Bone Joint Surg Am 91:128–133PubMedCrossRef Bozic KJ, Kurtz SM, Lau E, Ong K, Vail TP, Berry DJ (2009) The epidemiology of revision total hip arthroplasty in the United States. J Bone Joint Surg Am 91:128–133PubMedCrossRef
5.
go back to reference Grazioli A, Ek ET, Rüdiger HA (2012) Biomechanical concept and clinical outcome of dual mobility cups. Int Orthop 36:2411–2418PubMedCrossRef Grazioli A, Ek ET, Rüdiger HA (2012) Biomechanical concept and clinical outcome of dual mobility cups. Int Orthop 36:2411–2418PubMedCrossRef
6.
go back to reference Guyen O, Pibarot V, Vaz G, Chevillotte C, Carret JP, Bejui-Hugues J (2007) Unconstrained tripolar implants for primary total hip arthroplasty in patients at risk for dislocation. J Arthroplasty 22:849–858PubMedCrossRef Guyen O, Pibarot V, Vaz G, Chevillotte C, Carret JP, Bejui-Hugues J (2007) Unconstrained tripolar implants for primary total hip arthroplasty in patients at risk for dislocation. J Arthroplasty 22:849–858PubMedCrossRef
7.
go back to reference Jolles BM, Zangger P, Leyvraz PF (2002) Factors predisposing to dislocation after primary total hip arthroplasty: a multivariate analysis. J Arthroplasty 17:282–288PubMedCrossRef Jolles BM, Zangger P, Leyvraz PF (2002) Factors predisposing to dislocation after primary total hip arthroplasty: a multivariate analysis. J Arthroplasty 17:282–288PubMedCrossRef
8.
go back to reference Conroy JL, Whitehouse SL, Graves SE, Pratt NL, Ryan P, Crawford RW (2008) Risk factors for revision for early dislocation in total hip arthroplasty. J Arthroplasty 23:867–872PubMedCrossRef Conroy JL, Whitehouse SL, Graves SE, Pratt NL, Ryan P, Crawford RW (2008) Risk factors for revision for early dislocation in total hip arthroplasty. J Arthroplasty 23:867–872PubMedCrossRef
9.
go back to reference Woo RY, Morrey BF (1982) Dislocations after total hip arthroplasty. J Bone Joint Surg Am 64:1295–1306PubMed Woo RY, Morrey BF (1982) Dislocations after total hip arthroplasty. J Bone Joint Surg Am 64:1295–1306PubMed
10.
go back to reference Woolson ST, Rahimtoola ZO (1999) Risk factors for dislocation during the first 3 months after primary total hip replacement. J Arthroplasty 14:662–668PubMedCrossRef Woolson ST, Rahimtoola ZO (1999) Risk factors for dislocation during the first 3 months after primary total hip replacement. J Arthroplasty 14:662–668PubMedCrossRef
11.
go back to reference Hedlundh U, Hybbinette CH, Fredin H (1995) Influence of surgical approach on dislocations after Charnley hip arthroplasty. J Arthroplasty 10:609–614PubMedCrossRef Hedlundh U, Hybbinette CH, Fredin H (1995) Influence of surgical approach on dislocations after Charnley hip arthroplasty. J Arthroplasty 10:609–614PubMedCrossRef
12.
go back to reference Coventry MB (1985) Late dislocations in patients with Charnley total hip arthroplasty. J Bone Joint Surg Am 67:832–841PubMed Coventry MB (1985) Late dislocations in patients with Charnley total hip arthroplasty. J Bone Joint Surg Am 67:832–841PubMed
13.
go back to reference Prudhon JL (2011) Dual-mobility cup and cemented femoral component: 6 year follow-up results. Hip Int 21:713–717PubMedCrossRef Prudhon JL (2011) Dual-mobility cup and cemented femoral component: 6 year follow-up results. Hip Int 21:713–717PubMedCrossRef
14.
go back to reference Vielpeau C, Lebel B, Ardouin L, Burdin G, Lautridou C (2011) The dual mobility socket concept: experience with 668 cases. Int Orthop 35:225–230PubMedCrossRef Vielpeau C, Lebel B, Ardouin L, Burdin G, Lautridou C (2011) The dual mobility socket concept: experience with 668 cases. Int Orthop 35:225–230PubMedCrossRef
15.
go back to reference D’Aubigné RM, Postel M (1954) Functional results of hip arthroplasty with acrylic prosthesis. J Bone Joint Surg Am 35:451–475 D’Aubigné RM, Postel M (1954) Functional results of hip arthroplasty with acrylic prosthesis. J Bone Joint Surg Am 35:451–475
16.
go back to reference Devane PA, Horne JG, Martin K, Coldham G, Krause B (1997) Three-dimensional polyethylene wear of a press-fit titanium prosthesis. Factors influencing generation of polyethylene debris. J Arthroplasty 12:256–266PubMedCrossRef Devane PA, Horne JG, Martin K, Coldham G, Krause B (1997) Three-dimensional polyethylene wear of a press-fit titanium prosthesis. Factors influencing generation of polyethylene debris. J Arthroplasty 12:256–266PubMedCrossRef
17.
go back to reference Wroblewski BM, Siney PD, Fleming PA (2007) Charnley low-friction arthroplasty: survival patterns to 38 years. J Bone Joint Surg Br 89-B:1015–1018CrossRef Wroblewski BM, Siney PD, Fleming PA (2007) Charnley low-friction arthroplasty: survival patterns to 38 years. J Bone Joint Surg Br 89-B:1015–1018CrossRef
18.
go back to reference Hamadouche M, Baqué F, Lefevre N, Kerboull M (2008) Minimum 10-year survival of Kerboull cemented stems according to surface finish. Clin Orthop Relat Res 466:332–339PubMedCrossRef Hamadouche M, Baqué F, Lefevre N, Kerboull M (2008) Minimum 10-year survival of Kerboull cemented stems according to surface finish. Clin Orthop Relat Res 466:332–339PubMedCrossRef
19.
go back to reference Lee BP, Berry DJ, Harmsen WS, Sim FH (1998) Total hip arthroplasty for the treatment of an acute fracture of the femoral neck: long-term results. J Bone Joint Surg Am 80:70–75PubMedCrossRef Lee BP, Berry DJ, Harmsen WS, Sim FH (1998) Total hip arthroplasty for the treatment of an acute fracture of the femoral neck: long-term results. J Bone Joint Surg Am 80:70–75PubMedCrossRef
20.
21.
go back to reference Ali Khan MA, Brakenbury PH, Reynolds IS (1981) Dislocation following total hip replacement. J Bone Joint Surg Br 63-B:214–218PubMed Ali Khan MA, Brakenbury PH, Reynolds IS (1981) Dislocation following total hip replacement. J Bone Joint Surg Br 63-B:214–218PubMed
22.
go back to reference García-Cimbrelo E, Munuera L (1992) Dislocation in low-friction arthroplasty. J Arthroplasty 7:149–155PubMedCrossRef García-Cimbrelo E, Munuera L (1992) Dislocation in low-friction arthroplasty. J Arthroplasty 7:149–155PubMedCrossRef
23.
go back to reference Adam P, Philippe R, Ehlinger M, Roche O, Bonnomet F, Molé D, Fessy MH et al (2012) Dual mobility cups hip arthroplasty as a treatment for displaced fracture of the femoral neck in the elderly. A prospective, systematic, multicenter study with specific focus on postoperative dislocation. Orthop Traumatol Surg Res 98:296–300PubMedCrossRef Adam P, Philippe R, Ehlinger M, Roche O, Bonnomet F, Molé D, Fessy MH et al (2012) Dual mobility cups hip arthroplasty as a treatment for displaced fracture of the femoral neck in the elderly. A prospective, systematic, multicenter study with specific focus on postoperative dislocation. Orthop Traumatol Surg Res 98:296–300PubMedCrossRef
24.
go back to reference Caton J, Prudhon JL (2011) Over 25 years survival after Charnley’s total hip arthroplasty. Int Orthop 35:185–188PubMedCrossRef Caton J, Prudhon JL (2011) Over 25 years survival after Charnley’s total hip arthroplasty. Int Orthop 35:185–188PubMedCrossRef
25.
go back to reference Lecuire F, Benareau I, Rubini J, Basso M (2004) Intra-prosthetic dislocation of the Bousquet dual mobility socket. Rev Chir Orthop Reparatrice Appar Mot 90:249–255PubMedCrossRef Lecuire F, Benareau I, Rubini J, Basso M (2004) Intra-prosthetic dislocation of the Bousquet dual mobility socket. Rev Chir Orthop Reparatrice Appar Mot 90:249–255PubMedCrossRef
Metadata
Title
Dual mobility cup: dislocation rate and survivorship at ten years of follow-up
Authors
Jean-Louis Prudhon
André Ferreira
Régis Verdier
Publication date
01-12-2013
Publisher
Springer Berlin Heidelberg
Published in
International Orthopaedics / Issue 12/2013
Print ISSN: 0341-2695
Electronic ISSN: 1432-5195
DOI
https://doi.org/10.1007/s00264-013-2067-2

Other articles of this Issue 12/2013

International Orthopaedics 12/2013 Go to the issue